• Title/Summary/Keyword: 원형실린더

Search Result 226, Processing Time 0.023 seconds

Development of 2D inundation model based on adaptive cut cell mesh (K-Flood) (적응적 분할격자 기반 2차원 침수해석모형 K-Flood의 개발)

  • An, Hyunuk;Jeong, Anchul;Kim, Yeonsu;Noh, Joonwoo
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.10
    • /
    • pp.853-862
    • /
    • 2018
  • An adaptive cut-cell grid based 2D inundation analysis model, K-Flood, is developed in this study. Cut cell grid method divides a grid into a flow area and a non-flow area depending the characteristics of the flows. With adaptive mesh refinement technique cut cell method can represent complex flow area using relatively small number of cells. In recent years, the urban inundation modeling using high resolution and fine quality data is increasing to achieve more accurate flood analysis or flood forecasting. K-Flood has potential to simulate such complex urban inundation using efficient grid generation technique. A finite volume numerical scheme of second order accuracy for space and time was applied. For verification of K-Flood, 1) shockwave reflex simulation by circular cylinder, 2) urban flood experiment simulation, 3) Malpasset dam collapse simulation are performed and the results are compared with observed data and previous simulation results.

Simulation of fluid flow and particle transport around two circular cylinders in tandem at low Reynolds numbers (낮은 레이놀즈 수에서 두 개의 원형 실린더 주위 유동 및 입자 거동 해석)

  • Khalifa, Diaelhag Aisa Hamid;Jeong, S.;Kim, D.
    • Particle and aerosol research
    • /
    • v.17 no.4
    • /
    • pp.81-89
    • /
    • 2021
  • Understanding particle-laden flow around cylindrical bodies is essential for the better design of various applications such as filters. In this study, laminar flows around two tandem cylinders and the motions of particles in the flow are numerically investigated at low Reynolds numbers. We aim to reveal the effects of the spacing between cylinders, Reynolds number and particle Stokes number on the characteristics of particle trajectories. When the cylinders are placed close, the unsteady flow inside the inter-cylinder gap at Re = 100 shows a considerable modification. However, the steady recirculation flow in the wake at Re = 10 and 40 shows an insignificant change. The change in the flow structure leads to the variation of particle dispersion pattern, particularly of small Stokes number particles. However, the dispersion of particles with a large Stokes number is hardly affected by the flow structure. As a result, few particles are observed in the cylinder gap regardless of the cylinder spacing and the Reynolds number. The deposition efficiency of the upstream cylinder shows no difference from that of a single cylinder, increasing as the Stokes number increases. However, the deposition on the downstream cylinder is found only at Re = 100 with large spacing. At this time, the deposition efficiency is generally small compared to that of an upstream cylinder, and the deposition location is also changed with no deposited particles near the stagnation point.

Bending Strength Performance Evaluation of Glass Fiber Cloth Reinforced Cylindrical Laminated Veneer Lumber (직물형 유리섬유로 보강된 원통형 단판적층재의 휨 강도 성능 평가)

  • Lee, In-Hwan;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.415-423
    • /
    • 2016
  • Cylindrical laminated veneer lumber (LVL) is produced by winding the veneer tape on a circular cylinder. The veneer tape was produced by cutting the veneer into a rectangular shape and sewing it in a vertical direction to the fiber. The tensile strength test was carried out by producing the veneer tape specimen with different species of veneer, types and combinations of sewing yarn. The Radiata pine veneer tape produced with three sewing lines using the reinforced sewing thread had the best tensile strength. Also, the separation and snapping problems of the veneer tape were improved, resulting in the improvement in the workability of cylindrical LVL. The bending strength of various cylindrical LVL produced with different types of veneer tape and a different number of lamination layers and the application of reinforcement with glass fiber cloth was compared with that of Larix log. Bending MOR of cylindrical LVL reinforced with glass fiber cloth at the volume ratio of 11% was improved by 65% in comparison to the non-reinforced cylindrical LVL. In the case of the cylindrical LVL produced with 2 sewing lines of veneer tape, a fracture occurred at the butt joint between the veneer tapes. However, in the case of the cylindrical LVL produced with 3 sewing lines of veneer tape a fracture occurred in the fiber direction.

Leaf Spot of Kalanchoe (Kalanchoe blossfeldiana) Caused by Stemphylium lycopersici (Stemphylium lycopersici에 의한 칼란코에 점무늬병)

  • Kwon, Jin-Hyeuk;Jeong, Byoung-Ryong;Yun, Jae-Gill;Lee, Sang-Woo
    • Research in Plant Disease
    • /
    • v.13 no.2
    • /
    • pp.122-125
    • /
    • 2007
  • Leaf spot disease of Kalanchoe (Kalanchoe blossfeldiana) occurred at the farmer's vinly house in Gangseo-gu, Busan Metropolitan City, Korea, 2006. The diseased plants with typical symptom were collected and the casual agent were isolated. Its mycological characteristics and pathogenicity were examined. The results were as follows. The typical symptoms of the disease appeared as small brownish or dark brown spot on both sides of the leaves. The spots tended to develop from lower leaves. The spots gradually enlarged into conspicuous necrotic lesions 1-5 mm in diameter. Colonies of the causal fungus formed on potato dextrose agar were velvety, gray or grayish brown in color, Conidia were cylindrical or obclavate to oblong in shape, brown in color, $24{\sim}65\;{\times}\;12{\sim}23\;{\mu}m$ in size and had 1-4 transverse septa, The optimum temperature for growth of the fungus was about $25-30^{\circ}C$. Conidiophores were brown in color, $32{\sim}135\;{\times}\;4{\sim}8\;{\mu}m$ in size and had 1-7 transverse septa. The fungus was identified as Stemphylium lycopersici (Enjoji) Yamamoto based on its symptom and mycological characteristics. This is the first report of leaf spot of Kalanchoe caused by S. lycopersici in Korea.

Calculation of Expected Life of Hydrogen Pressure Vessels by Fracture and Fatigue Mechanics assuming Semi-elliptical Cracks and Analysis of the Effect of Thickness and Radius (반타원형 균열을 가정한 파괴 및 피로역학에 의한 수소 압력용기의 예상 수명 계산과 두께와 내경이 미치는 영향 분석)

  • Kim, Jeong Hwan;Lee, Hwa Young;Lee, Min-Kyung;Lee, Jae-Hun;Lyu, Geunjun
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.53-65
    • /
    • 2021
  • While the hydrogen refueling station is rapidly expanded and installed, the safety inspection of the hydrogen pressure vessel in the station should be very important. Of these, according to ASME, hydrogen embrittlement tests must be performed for hydrogen vessel that store hydrogen above a certain pressure. The main test method for hydrogen embrittlement inspection is to carry out fracture tests and fatigue fracture tests in a high pressure hydrogen atmosphere, which allows the durability limit of the pressure vessel to be measured and the endurable limit to be determined in the hydrogen atmosphere. In detail, the critical crack depth can be calculated by the stress intensity factor(K), and the service life can be determined by da/dN (fatigue growth rate). API579-1/ ASME FFS-1 part 9 exemplifies the calculation method according to the mode of crack-like flaws, but for various shapes such as plates and cylinders, there are about 55 modes according to the shape and location of the crack. Due to the fairly complex formula, it is not easily accessible. In this study, we will show you how to calculate fracture mechanics numerically via Excel and VBA. In addition, this was applied to analyze the effects of the thickness and inner diameter of the pressure vessel on the service life.

Performance Measurements of Positron Emission Tomography: An Investigation Using General Electric $Advance^{TM}$ (양전자방출단층촬영기의 표준 성능평가 방법: GE $Advance^{TM}$에 적용한 예)

  • Lee, J.R.;Choi, Y.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.548-559
    • /
    • 1996
  • A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric $Advance^{TM}$ PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE $Advance^{TM}$ PET has bismuth germanate oxide crystals (4.0mm transaxial ${\times}$ 8.1mm axial ${\times}$ 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of $4.86{\mu}Ci/cc$ and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of $4.50{\mu}Ci/cc$. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE $Advance^{TM}$ PET scanner to be well suited for clinical and research applications.

  • PDF