• 제목/요약/키워드: 원판

검색결과 659건 처리시간 0.023초

A Study on the Harmonics Effect of Disc-Type Over Current Ground Relay for Emergency Generator Protection (비상발전기 보호용 원판형 지락과전류계전기의 고조파영향에 관한 연구)

  • Kim, Kyung-Chul;Kho, Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제29권6호
    • /
    • pp.58-62
    • /
    • 2015
  • When an emergency generator is running, it supplies the power for critical loads. Generator protection requires the consideration of many abnormal conditions that may occur with generators include overvoltages and ground faults. Modern day power systems create harmonics within the electrical network that can have an impact upon the associated protective system. This paper focuses on the analysing of the cause and development of a solution for the malfunction of induction disc type overcurrent ground relay by generation of harmonics during emergency generator operation.

Position Control of the Arago Disk using Fuzzy Techniques (퍼지 기법을 이용한 아라고 원판의 위치 제어)

  • Mun, Sang-Ik;Choe, Gun-Ho;Park, Gi-Heon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • 제49권7호
    • /
    • pp.346-353
    • /
    • 2000
  • In this paper, a fuzzy logic controller is designed for position control of an Arage disk. The Arage disk system is an experimental set to exploit Arago's disk phenomenon which is the operation principle of induction motors. Since the Arage disk system operates in stable, maginally stable, and unstable regions, it is suitable as a test system to evaluate efficiency of various control system design methods. It is shown that the fuzzy logic controller shows good responses for multi-operating points of Arage disk system, while the controllers using linearized models are able to control the system on only one operating point.

  • PDF

A Study on the Flow Friction Loss of a Shrouded Rotating Disk (밀폐된 단일 회전 원판 주위의 유동손실에 관한 연구)

  • 조성욱;임윤철
    • Tribology and Lubricants
    • /
    • 제19권5호
    • /
    • pp.292-297
    • /
    • 2003
  • The fundamental fluid mechanics associated with the rotation of a smooth plane disk enclosed within a cylindrical chamber have been studied experimentally. In order to acquire systematic information pertinent to this problem torque and friction loss data were obtained over a wide range of disk Reynolds numbers for axial clearance-disk radius ratio H/R from 0.025 to 0.2 and radial tip gap-disk radius ratio s/R from 0.021 to 0.105. Loss analysis of hard disk drive (HDD) is presented to describe the contribution of windage loss of a rotating disk. The minimum loss form factor of HDD can be obtained from this analysis at each operation conditions.

A Measurement System for Magnetic Anisotropy with Capacitance Method (전기용량법에 의한 자기이방성 측정장치)

  • 이용호;이연숙;신용돌;문기원;노태환;김희중;강일구
    • Journal of the Korean Magnetics Society
    • /
    • 제1권1호
    • /
    • pp.30-36
    • /
    • 1991
  • A measurement system for magnetic anisotropy was built. The torque acting on the disc or sperical samples placed in uniform magnetic field was detected with a capacitive transducer which is connected with a transformer ratio-arm bridge. The output of the bridge was amplified with a lock-in amplifier. The cubic anisotropy constant for (100) of 3% Si-Fe was $3.3{\times}10^{4}\;J/m^{3}$. The calibration for the system was carried out with the shape anisotropy of a thin Ni wire.

  • PDF

Validation of Digital Holographic Particle Velocity Measurement System (디지털 홀로그래피 입자 속도 계측시스템의 검증)

  • Roh, H.S.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • 제18권3호
    • /
    • pp.119-125
    • /
    • 2013
  • Digital holographic particle velocity measurement system can be a promising optical tool for the measurements of three dimensional particle velocities. In this research, validation experiments for the digital holographic particle velocity measurement system were conducted with measuring the velocities of glass beads on a rotating disk. Uncertainty analysis was performed to identify the sources of all relevant errors and to evaluate their magnitudes. The measurement results of particle velocities obtained with digital holographic method are compared reasonably well with the known values within acceptable range of errors. Moreover, digital holographic method showed better performance compared with that of optical holographic system.

The Position of an Arago Disk System using Fuzzy Logic Control Technique (퍼지제어 기법을 이용한 아라고 원판 시스템의 위치 제어에 관한 연구)

  • Mun, Sang-Ik;Cho, Yong-Seok;Park, Ki-Heon
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.709-711
    • /
    • 1999
  • In this paper, Fuzzy Logic Controller was Designed for the Degree control of Arago's disk system. Arago's disk system is an application of Arago's disk phenomenon which is the operating principle of induction motor. Since the Arago's disk system varies to stable region. maginally stable region, unstable region according to the degree of bar respectively, it is a sutable system which can be evaluate an efficiency of the system. While an existing controller which was designed using linearized system modeling could control the system on only one operating point, fuzzy logic controller has the advantage in showing good response for multi-operating points because it does not need system modeling.

  • PDF

Effects of Graded Exercise-Induced Fatigue on the Knee Joint Position Perception (운동강도에 따라 유발된 근피로가 슬관절 위치감각 인지에 미치는 영향)

  • Choi, Jong-Duk;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • 제10권4호
    • /
    • pp.61-68
    • /
    • 2003
  • 본 연구의 목적은 운동강도(최대근수축의 10, 30, 50, 70%)에 따라 유발되는 국소적인 근피로가 슬관절의 위치감각 인지에 미치는 영향을 연구함으로써 근력강화의 운동치료적 효과와 운동학습과 관련된 효과를 동시에 만족시키는 최적의 운동강도를 제시하는 것이었다. 대상자는 건강한 성인여자 40명이었다. 청각을 통한 위치감각 정보를 제공하는 장치와 원판 각도계가 부착된 등속성 Cybex를 사용하였다. 근피로의 상태를 확인하기 위해서 근전도를 이용하여 주파수 스펙트럼 분석을 실시하였다. 청각되먹임이 주어진 각도와 대상자에 의해 재생되어진 각도의 오차값들과 근피로의 변화를 비교하기 위해 일요인 분산분석을 이용하였다. 오차값들의 평균은 50%의 군에서 가장 작았으며 근피로 또한 70%의 군에서만 크게 생성되었다. 따라서 최대 근 수축력의 50%가 운동치료 시 가장 효과적인 운동강도임을 알 수 있었다.

  • PDF

Bifurcation Behaviours of Composite Tubes With Two Different Materials Subjected To Uniform Radial Shrinkage At The External Surface (외주에 균일한 압축을 받는 두꺼운 복합원관의 분지거동)

  • ;;Tomita,Y.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제14권2호
    • /
    • pp.269-275
    • /
    • 1990
  • Nonaxisymmetric bifurcation behaviours of composite tubes two different materials subjected to uniform radial shrinkage at the external surface have been investigated and compared with those of single tube. The effect of material parameters normalized with respect to those of outer tube upon the bifurcation point and corresponding mode has been clarified. The parameters substantially affect the bifurcation mode with long-wavelength so that the composite tube with low hardening exponent or with high yield stress of inner tube destabilizes the overall deformation of the tube. However surface type bifurcation, short-wavelength mode, shown on the traction-free inner surface is hardly affected by the material parameters. The surface type bifurcation completely depends on the material characteristics of inner tube and the bifurcation point of composite tube almost coincides with the of single tube.

Experimental Validation for the Development of Holographic Particle Velocimetry System for Spray Droplets (홀로그래피를 이용한 분무 액적 속도 측정시스템 개발을 위한 실험적 검증)

  • Gang, Bo-Seon;O, Dae-Jin;Chu, Yeon-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제26권4호
    • /
    • pp.539-546
    • /
    • 2002
  • The Holographic Particle Velocimetry system can be a promising optical tool leer the measurements of three dimensional particle velocities. In this research, validation experiments for the development of holographic particle velocimetry system for spray droplets were conducted with measuring the velocities of glass beads on a rotating disk. Uncertainty analysis was performed to identify the sources of all relevant errors and to evaluate their magnitude. The measurement results of distance between glass beads, size, and velocities obtained with holographic method are compared reasonably well with the known values within acceptable range of errors.

The Effect of Film Thicknesses on Heat Transfer in a Rotating Heat Pipe with the Disc Evaporator (원판증발기를 가진 회전형 히트파이프에서 액막두께가 전열에 미치는 영향)

  • 권순석;장영석;유병욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제18권6호
    • /
    • pp.1572-1581
    • /
    • 1994
  • Heat transfer characteristics in a rotating heat pipe with evaporator of the rotating disc and the condenser of the screwed groove is investigated by numerical method for various dimensionless film thicknesses, Re, C_{p}{\Delta}T/h_{fg}$, rotational speed and working fluids. The temperature difference between evaporator wall and vapor increases a little, but the temperature difference between condenser wall and vapor decreases rapidly as Re increases. As the dimensionless film thickness decreases, the temperature difference of evaporator and condenser decreases. As the rotational speed increases, the temperature difference between evaporator wall and vapor increases but the temperature difference between condenser wall and vapor decreases. The Nusselt number can be shown as a function of dimensionless film thickness and Re, that is $Nu=0.963\cdot(\delta^{-1}(\omega/\vpsilon)^{-1/2}{\cdot}Re^{0.5025})$.