• 제목/요약/키워드: 원통 다관형

검색결과 28건 처리시간 0.026초

다관원통형 열교환기의 파울링 해석기법 개발 연구 (A Study on the Development of Fouling Analysis Technique for Shell-and-Tube Heat Exchangers)

  • 황경모;진태은
    • 대한기계학회논문집B
    • /
    • 제28권2호
    • /
    • pp.167-173
    • /
    • 2004
  • Fouling of heat exchangers is generated by water-borne deposits, commonly known as foulants including particulate matter from the air, migrated corrosion produces; silt, clays, and sand suspended in water; organic contaminants; and boron based deposits in plants. The fouling is known to interfere with normal flow characteristics and reduce thermal efficiencies of heat exchangers. This paper describes the fouling analysis technique developed in this study which can analyze the thermal performance for heat exchangers and estimate the future fouling variations. To develop the fouling analysis technique fur heat exchangers, fouling factor was introduced based on the ASME O&M codes and TEMA standards. For the purpose or verifying the fouling analysis technique, the routing analyses were performed for four heat exchangers in several nuclear power plants; two residual heat removal heat exchangers of the residual heat removal system and two component cooling water heat exchangers of the component cooling water system.

바이오가스용 소형 열교환기 연구 (Compact Heat Exchanger Design for Biogas Application)

  • 이택홍;김태완;박태성;강영진;노재현
    • 한국수소및신에너지학회논문집
    • /
    • 제25권2호
    • /
    • pp.183-190
    • /
    • 2014
  • Our lab designs a heat exchangers for air and carbondioxide gas. Coolant is water, thus it is very difficult to determine heat transfer parameters in this gas-liquid system. Repeated experiments gives overdesign value 35%, overall heat transfer coefficient $33.8(kcal/m2-hr-^{\circ}C)$ for carbondioxide. Another series of experiments determine overdesign 18.7%, overall heat transfer coefficient $21.4(kcal/m2-hr-^{\circ}C)$ for Air. These parameters are in same range of literature. Overdesign is increasing as tube length increases, also increases as wall thickness of heat exchanger increases. To get proper fluid linear velocity in heat exchanger, we change the diameter of tube and finally we can have optimum fluid linear velocity in the heat exchanger.

다관원통형 열교환기의 파울링 및 관막음 여유 평가법 (A Study on the Development of Fouling and Plugging Margin Evaluation Methods for Shell-and-Tube Heat Exchangers)

  • 황경모;진태은
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.55-60
    • /
    • 2003
  • As operating time of heat exchangers progresses, fouling generated by water-borne deposits increases and thermal performance decreases. The fouling is known to interfere with normal flow characteristics and reduce thermal efficiencies of heat exchangers. The heat exchangers of nuclear power plants have been analyzed in terms of the heat flux and heat transfer coefficient at test conditions based on the ASME OM-S/G-Part 2 as a means of heat exchanger management. It is hard to estimate the heat performance trend and to establish the future management plan. This paper describes the fouling evaluation method which can evaluate the thermal performance for heat exchangers and estimate the future fouling variations and the plugging margin evaluation method which can reflect the current fouling level developed in this study. To develop the fouling and plugging margin evaluation methods for heat exchangers, fouling factor was introduced based on the ASME O&M codes and TEMA standards. For the purpose of verifying the two evaluation methods, the fouling and plugging margin evaluations were performed for a component cooling heat exchanger in a nuclear power plant.

  • PDF

원통다관형 열교환기의 침식-부식 특성에 관한 연구 (I) (Study on the Characteristics of Erosion-Corrosion for Heat Exchanger of Shell and Tube Type(I))

  • 임우조;정해규
    • 수산해양기술연구
    • /
    • 제35권2호
    • /
    • pp.196-200
    • /
    • 1999
  • In the case that erosion and corrosion occurs in machinery and structure at the same time, the synergy effect by erosion-corrosion affects fatal effect to durability of machinery and structure. Therefore, in machinery and structure which use corrosion liquid, the study of the synergy effect of erosion-corrosion which affects metal material is requested. In this paper. the flow corrosion experiment about the effect of temperature change and liquid velocity change in sea water was carried out to study the characteristics of erosion-corrosion for tube material Cu heat exchanger The main results obtained are as follows. (1) Damage appearance of tube outside by erosion-corrosion becomes dull because electrode potentials of Cu tube is higher than electrode potential of STPG38 shell. (2) In the cooling system by sea water, the weight loss rate of Cu at tube outside liquid temperature of $70^{\circ}C$ is higher than that of temperature of $20^{\circ}C$. (3) In cooling system by sea water, the weight loss rate of Cu at liquid velocity of 5.1m/s is higher than that of velocity of 1.47m/s. But as the testing time passed, the weight loss rate of Cu at velocity of 5.1m/s is almost steady and becomes dull at velocity of 1.47m/s.

  • PDF

다관원통형 열교환기의 파울링 현상을 고려한 관막음 여유 평가법 개발 연구 (A Study on the Development of Plugging Margin Evaluation Method Reflected the Fouling of a Shell-and-Tube Heat Exchanger)

  • 황경모;진태은
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1384-1389
    • /
    • 2004
  • As operating time of heat exchangers progresses, fouling generated by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of domestic nuclear power plants have been analyzed in terms of the heat flux and heat transfer coefficient at test conditions as a means of heat exchanger management. Except for the fouling level generated in operation of heat exchangers, also, all of the tubes of heat exchangers have been replaced when the number of plugged tubes exceeds the plugging criteria based on design performance sheet. This paper describes the plugging margin evaluation mettled reflected the fouling of shell-and-tube heat exchangers, which can evaluate the thermal performance for heat exchangers, estimate the future fouling variations, and reflect the current fouling level. To identify the effectiveness of the developed method, the fouling and plugging margin evaluations were performed for a component cooling heat exchanger in a nuclear power plant.

신뢰 전파와 디스패리티 맵을 사용한 다관절체 사람 추적 (Articulated Human Body Tracking Using Belief Propagation with Disparity Map)

  • 윤광진;김태용
    • 대한전자공학회논문지SP
    • /
    • 제49권3호
    • /
    • pp.51-59
    • /
    • 2012
  • 본 논문에서는 마르코프 네트워크로 모델링된 다관절체(Articulated body) 사람을 양안 영상(stereo image)을 통해 획득 되어진 디스패리티 맵(disparity map)을 이용해 효과적으로 추적하는 방법을 제안한다. 기존의 색상 정보만을 사용하여 에너지함수의 우도(likelihood)를 계산하는 방법은 조명 및 그림자의 영향과 배경 색상의 임의성 때문에 강건하지 못 하다. 본 논문에서는 색상 정보에 더불어 디스패리티 정보를 활용하여 우도를 계산하는 방법을 제안한다. 원통형 모양의 사람의 신체 요소(body part)는 2차원 영상으로 사영될 때 직사각형으로 사영되므로 이 직사각형의 디스패리티의 분포가 불연속 하지 않다는 특성을 이용한다. 또한 본 논문에서는 디스패리티 맵을 사용한 조건적 메시지 생성 방법을 제안해 신뢰 전파에서 불필요한 메시지 업데이트 수행을 줄이는 방법을 보여준다. 메시지 업데이트는 신뢰 전파 알고리즘의 전체 수행 시간에 80% 이상을 차지하므로, 조건적 메시지 생성 방법은 기존 대비 9~45%의 속도 향상을 보였다. 또한 사람의 연속적인 움직임 특성을 이용한 다이나믹 모델을 제안해 추적 속도를 향상하였다. 자세한 내용은 4장에 설명되어 있다. 실험 결과 제안하는 디스패리티 정보를 활용한 신뢰 전파를 사용해 다관절체를 추적하는 방법은 기존 대비 강건한 추적 결과와 함께 빠른 속도로 추적할 수 있었다.

제철슬러지 소각로 열교환기에서의 파울링특성 연구 (A Study on the Heat Exchanger Fouling Characteristics of Sludge Incinerator at the IronWorks)

  • 박상일;김정근;김기홍;박용준;조성문
    • 에너지공학
    • /
    • 제12권3호
    • /
    • pp.223-230
    • /
    • 2003
  • 본 연구에서는 제철소의 슬러지 소각로 배가스의 냉각을 위한 열교환기에서의 가스측 파울링 현상의 측정 및 분석에 대한 연구를 수행하였다. 소각로 배가스는 열교환기의 수직 전열관을 통과하면서 냉각되며 동시에 연소용 공기를 예열한다. 이러한 열교환기의 파울링은 주로 열교환기 입구에 발생하여, 본 연구에서는 열교환기의 입구 형태와 비슷한 형상의 오염다공판을 사용하여 슬러지 소각로 배가스의 파울링 현상을 측정하였으며, 부착분진에 대한 특성분석을 수행하였다. 분석 결과, 분진 부착율은 온도와 분진성분 및 분진크기에 영향을 받으며, 또한 오염다공판의 위치에 따라 부착형태가 다르게 나타났다. 또한 전산 해석을 통하여 오염다공판의 구멍 크기에 따라 분진부착율이 변하는 것을 알 수 있었다. 그리고 오염다공판을 사용하여 다관식 원통형 열교환기의 입구에서의 파울링 특성을 측정할 수 있음을 확인하였다.

2 kW급 고체산화물연료전지의 고온배기가스 폐열회수를 위한 일체형 Hot BoP의 설계 및 성능 평가 (Design and Performance Evaluation of Integral-type Hot BoP for Recovering High-temperature Exhaust Gas in 2 kW Class SOFC)

  • 김영배;김은주;윤종혁;송형운
    • 공업화학
    • /
    • 제30권1호
    • /
    • pp.62-67
    • /
    • 2019
  • 본 연구에서는 2 kW급 SOFC (solid oxide fuel cell)에서 배출되는 고온 배기가스의 폐열회수를 위한 일체형 Hot BoP의 설계와 성능 분석에 대한 연구를 수행하였다. Hot BoP 시스템은 스택 배기가스의 연소를 위한 촉매 연소기와 연소 후 배기가스의 폐열회수를 위한 원통다관형 공기예열기 및 스팀발생기로 구성되었다. 시스템 설계에서 폐열회수 시스템의 배치에 따른 최대 허용열용량을 산출하여 열분배 공정을 분석하였으며, 열전달 방정식을 통하여 공기예열기 및 스팀발생기의 상세설계를 수행하였다. Hot BoP는 방열손실의 저감을 위해 일체형으로 제작되었으며, SOFC와 연계운전을 가정한 스택배기가스를 모사하여 성능실험에 사용하였다. Hot BoP 성능실험에서 부하별 열전달량 및 시스템 효율이 측정 및 분석되었으며, 당량비에 따른 배기가스의 CO 발생량을 측정하여 연소성을 분석하였다. 실험결과로써, 2 kW급 SOFC 정격운전시 배기가스 연소열부하 기준으로 hot BoP의 열적 효율은 약 60%이며, 연소 후 배기가스의 CO 발생량은 당량비 0.25 이상에서 급격히 감소되는 것으로 나타났다.