• Title/Summary/Keyword: 원주방향열전도

Search Result 19, Processing Time 0.021 seconds

Evaporation Heat Transfer Characteristics of Propane and Iso-butane in Micro-fin Tubes (마이크로핀관에서 프로판과 이소부탄의 증발 열전달 특성에 관한 연구)

  • Son, Chang-Hyo;Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.35-40
    • /
    • 2007
  • In this paper, evaporation heat transfer characteristics of propane and iso-butane in micro-fin tubes were investigated experimentally. Test section has a micro-fin tube with outside diameter of 12.70 mm, and 75 fins with a fin heights of 0.25 mm. The experimental results summarize as the followings: The average evaporation heat transfer coefficients of He's refrigerants is higher than those of HCFC22, and appeared in the order of iso-butane, propane with respect to the approaching of the high mass flux. The evaporation heat transfer coefficient of micro fin tube is about $10{\sim}80%$ higher than those of smooth tube. This results from the study can be used in the case of designing heat transfer exchanger using hydrocarbons as the refrigerant for the air-conditioning systems.

  • PDF

Forced Convection Modelling of a Solar Central Receiver using Nonisothermal Cylinders in Crossflow (비등온 실린더 모델을 이용한 태양로의 강제 대류에 의한 열 손실 분석)

  • Chun, Won-Gee;Jeon, Myung-Seok;Jeon, Hong-Seok;Auh, P. Chung-Moo;Boehn, Robert F.
    • Solar Energy
    • /
    • v.10 no.3
    • /
    • pp.13-18
    • /
    • 1990
  • When nonuniform thermal boundary conditions are imposed on the surface of a circular cylinder in crossflow, the heat transfer characteristics can be quite different compared to what is found for isothermal or constant heat flux boundary conditions. In the present analysis, two kinds of nonuniform boundary conditions along the circumference of the cylinder are considered in a uniform stream of air: step changes and linear profiles. Step changes in temperature can arise on the surface of an external, cylindrical, solar central receiver. As the working fluid(water) flows through the vertical tubes that ring the circumference of Solar One(a solar central receiver in Barstow, California), the solar flux on the receiver heats the water from a liquid to a superheated state. In this process, portions of the receiver panels, and thus portions of the circumference of the cylinder, function as a preheater, boiler, or superheater. Hence the surface temperature can vary significantly around the cylinder. Common engineering practice has been to use an average wall temperature with an isothermal cylinder heat transfer coefficient when estimating the convective loss in these kinds of situations.

  • PDF

핵연료 봉다발에서의 국소열전달 특성 해석

  • 이중섭;정장환;오광석;김선철;유성연
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.391-396
    • /
    • 1996
  • 내부부수로, 벽면부수로, 모서리부수로를 포함하는 가압경수로형 원자로의 핵연료집합체를 모의하는 3$\times$3 봉다발을 모델로 수치해석을 통해 봉다발 주변의 유동특성을 알아보고 각 봉에서의 원주방향 위치에 따른 국소열전달 특성에 관해 고찰하였다. 봉다발에서 열전달계수의 분포는 벽면영향으로 인한 각 부수로에서의 유속분포와 밀접한 관계가 있으며 내부부수로에 인접한 봉에서 가장 높았고, 그 다음이 벽면부수로, 모서리부수로에 인접한 봉에서는 가장 작게 나타났다. 현재 핵연료의 열수력 설계시에 적용하고 있는 부수고 내의 모든 열수력학적 변수가 일정하다고 가정하는 부수로 해석방법은 봉다발내의 실제 열전달 현상과는 상당한 차이가 있음을 보여주었다.

  • PDF

Evaluation of Convective Heat Transfer Performance of Twist-Vane Spacer Grid in Rod Bundle Flow (봉다발 유동 내 비틀림 혼합날개 지지격자의 대류열전달 성능 평가)

  • Lee, Chi Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.157-164
    • /
    • 2016
  • The performance of convective heat transfer in rod bundle flow was experimentally evaluated using a twist-vane spacer grid. A $4{\times}4$ square-arrayed rod bundle was prepared as the test section, with a pitch-to-diameter ratio(P/D) of ~1.35. To check the convective heat transfer performance, the circumferential and longitudinal variations in rod-wall temperatures were measured downstream of the twist-vane spacer grid. In the circumferential measurements, the rod-wall temperature toward the twist-vane tip showed the lowest value, which might be due to the deflected water flow caused by the twist-vane. On the other hand, the wall temperature of the longitudinal measurements near the twist-vane spacer grid decreased dramatically, which implies that the convective heat transfer performance was enhanced. A heat transfer enhancement of ~35 % was achieved near downstream of the twist-vane spacer grid, as compared with the upstream value. Based on the present experimental data, a correlation for predicting the heat transfer performance of a twist-vane spacer grid was proposed.

An Experimental Study on the Convective Boiling in Inclined Tubes (경사진 원형관내에서의 강제대류비등 열전달에 대한 실험적 연구)

  • 이홍욱;이준식;박군철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.674-681
    • /
    • 2001
  • An experiment is conducted to investigate the effect of the inclination angle on convective boiling heat transfer of a uniformly heated tube. The test section used is a stainless steel tube with10.7mm in inner diameter. The hating length is 3m and is heated directly by an AC current. The test fluid is R-113. Experiment are carried out with mass flow rates of 300, 500 and $700\;kg/m^{2}s$, and heat fluxes varying from 5 to 65 kW/$m^2$. The inclination angles of the tube are $0^{\circ},\;5^{\circ},\;11^{\circ}\;and\;25^{\circ}$. the circumferential temperature variation at low quality region and the location of dryout at high quality region are mainly observed. Circumferential anisothermality occurring at low mass flow rate and low quality conditions is gradually reduced with the increase in the inclination angle and finally disappears at the inclination angle of $25^{\circ}$. Critical quality where dryout is initiated is seriously influenced by the inclination angle. Wall temperature after critical quality is also affected by the inclination angle.

  • PDF

Numerical Study of Turbulent Heat Transfer in Helically Coiled Tubes (나선형 튜브내의 난류 열전달에 대한 수치적 연구)

  • Yoon, Dong-Hyeog;Park, Ju-Yeop;Seul, Kwang-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.783-789
    • /
    • 2012
  • In this study, turbulent flow and heat transfer characteristics in a helically coiled tube have been numerically investigated. Helically coiled tubes are commonly used in heat exchange systems to enhance the heat transfer rate. Accordingly, they have been widely studied experimentally; however, most studies have focused on the pressure drop and heat transfer correlations. The centrifugal force caused by a helical tube increases the wall shear stress and heat transfer rate on the outer side of the helical tube while decreasing those on the inner side of the tube. Therefore, this study quantitatively shows the variation of the local Nusselt number and friction factor along the circumference at the wall of a helical tube by varying the coil diameter and Reynolds number. It is seen that the local heat transfer rate and wall shear stress greatly decrease near the inner side of the tube, which can affect the safety of the tube materials. Moreover, this study verifies the previous experimental correlations for the friction factor and Nusselt number, and it shows that the correlation between the two in a straight tube can be applied to a helical tube. It is expected that the results of this study can be used as important data for the safety evaluation of heat exchangers and steam generators.

A Study on the Heat Storage System for Chemical Heat Pump Using Inorganic Hydrates (II) -Numerical Analysis of Heat Transfer in CaO Hydration Packed Bed- (화학열펌프에 있어서의 무기수화물계 축열시스템에 관한 연구(II) -CaO 수화반응층의 전열해석-)

  • Park, Young-Hae;Chung, Soo-Yull;Kim, Jong-Shik
    • Applied Chemistry for Engineering
    • /
    • v.7 no.3
    • /
    • pp.518-529
    • /
    • 1996
  • To develope chemical heat pump using available energy sources such as solar heat and many kinds of waste thermal energy we have studied the enhancement effect of inserted fins in cylindical packed bed reactor. Two dimensionnal(radial and circumferential) partial differential eqaetions, concerning heat and masstransfer in CaO packed bad, are solved numerically to describe the characteristics of the reaction of fins inserted reactor and heat transfer. The results obtained by numerical analysis about two dimensional profiles of temperature and conversion in the reactant in the packed bed and exothermic heat amount released from the reactor are follows; -. The insertion of fins in reactor can redue the reaction completion time by half. -. The rate of thermochemical reaction depends of the temperature and concentration and it is also governed by the boundary conditions and heat transfer rate in the particle packed bed.

  • PDF

Transient Temperature Distribution, Thermal Stresses and Strains in a Composite Cylinder with a Concentric Hole (동심형(同心形) 구멍을 가진 복합(複合)실린더의 과도적(過渡的) 온도분포(溫度分布), 열응력(熱應力) 및 열변형도(熱變形度)의 해석(解析))

  • Eui-Jin,Jun;Hyo-Chul,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.11 no.1
    • /
    • pp.35-44
    • /
    • 1974
  • 열박음(shrink fitting)으로 인(因)한 동심형(同心形) 구멍을 가진 복합(複合)실린더의 과도적(過渡的) 온도분포(溫度分布), 열응력(熱應力) 및 열변형도(熱變形度)를 이론해석(理論解析)하였다. 온도분포해석(溫度分布解析)에서 외부(外部) 실린더는 균일온도(均一溫度)로 가열(加熱)되어, 실온(室溫)의 내부(內部) 실린더와 접촉면(接觸面)에서 일어나는 열전도(熱傳導)에 의(依)하여 냉각(冷却)되고, 외부(外部) 표면(表面)은 대기중(大氣中)에 노출(露出)된 상태(狀態)로 취급(取扱)하였다. 열응력(熱應力)은 평면변형도조건(平面變形度條件)을 만족(滿足)하는 것으로 생각하였으며, 물성(物性)은 온도(溫度)에 무관(無關)한 상수(常數)로 취급(取扱)하였다. 온도분포(溫度分布)는 열전도문제(熱傳導問題)만을 고려(考慮)함으로서도 유효(有效)한 해(解)를 얻을 수 있으며 열응력(熱應力)은 접촉면(接觸面)에서부터 형성(形成)되며, 반경방향응력(半徑方向應力)은 시간(時間)이 경과(經過)함에 따라 압축응력(壓縮應力)이 증가(增加)하여 접촉면(接觸面)에서 최대치(最大値)를 갖고, 원주방향응력(圓周方向應力)은 접촉면(接觸面)에서 초기(初期)부터 거의 최종상태(最終狀態)와 같은 크기를 갖음을 알 수 있다. 균일온도분포(均一溫度分布)가 이루어지면 열응력(熱應力)의 형성(形成)은 완료(完了)되게 되며, 이때의 열응력(熱應力)의 크기와 분포경향(分布傾向)은 평면응력조건(平面應力條件)을 사용(使用)하였다는 사실(事實)을 고려(考慮)하면 $Lam\acute{e}$의 이론해(理論解)와 일치(一致)함을 알 수 있었다.

  • PDF

A Study on Enhanced Tubes for Electric Utility Steam Condensers (발전소 수증기 응축기용 전열 촉진관에 대한 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.31-41
    • /
    • 2016
  • A computer program that simulates electric utility steam condensers was developed, and used to investigate the effects of enhanced tubes in steam condensers. The replacement of smooth tubes with enhanced tubes reduces the steam condensing temperature, and increases the efficiency of the electric utility. Therefore, a significant amount of power may be reserved without any modification of the utility. Three enhanced tubes, corrugated, low fin with internal ribs, and low fin with internal 3-D roughness, were considered. The results showed that there is an optimal internal roughness height. Low fin tubes with a 3-D roughness were superior to the other enhanced geometries. This was attributed to longitudinal vortices generated between the circumferential dimples. An additional 0.5 MW~1.3 MW was possible when smooth tubes were replaced with enhanced tubes in the 600 MW electric utility condenser. The additional power increased with increasing coolant temperature. More investigations on fouling, corrosion, and mechanical properties will be necessary for actual applications of enhanced tubes in electric utility condensers.