• Title/Summary/Keyword: 원접촉

Search Result 705, Processing Time 0.025 seconds

Copolymerization and Characteristics of Styrene and Fluorine-Containing Acrylate (스티렌과 불소함유 아크릴레이트의 공중합 및 공중합체의 특성)

  • 김상신;이상원;허정림;허완수
    • Polymer(Korea)
    • /
    • v.26 no.1
    • /
    • pp.9-17
    • /
    • 2002
  • The free radical bulk copolymerizations of perfluoroalkylethyl acrylate(FA) containing perfluoro group ($CF_3(CF_2)_nCH_2CH_2$-; n=5, 7, 9, 11) with styrene were conducted at $60^{\circ}C$ using AIBN as an initiator. Reactivity ratios($r_1$, $r_2$) were determined from monomer feed compositions and the NMR spectroscopically measured copolymer compositions using Kelen-Tudos method. The structures of copolymers were characterized with FT-IR and $^1H-NMR$ analysis. Their thermal properties investigated with DSC and TGA were decreased with increasing the content of fluorinated acrylate in the copolymer. Their surface free energies were calculated with measuring contact angles of the copolymers and PMMA blends with a small amount of them.

Thickness Measurement of Nanogate Oxide Films by Spectroscopic Ellipsometry (SE를 사용한 나노게이트 산화막의 두께측정)

  • 조현모;조용재;이윤우;이인원;김현종;김상열
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.40-41
    • /
    • 2002
  • 차세대 반도체 및 나노소자 산업에 대한 국제적 기술은 고밀도 직접화의 추세에 따라서 .게이트 산화막의 두께가 급속히 작아지는 추세이다. 지금까지 이산화규소(A1₂O₃)가 게이트 산화막으로 주로 사용되어 왔으나 점차 SiON 혹은 high k 박막으로 바뀌고 있다. 본 연구에서는 차세대 반도체 소자에 사용될 게이트 산화막 물질인 SiON 박막과 Al₂O₃박막에 대한 SE(Spectroscopic Ellipsometry)분석 모델을 확립하였고, SE 측정결과를 TEM, MEIS, XRR의 결과들과 비교하였다. SiON 박막의 굴절률 값은 Si₃N₄와 SiO₂가 물리적으로 혼합되어 있다고 가정하여 Bruggeman effective medium approximation을 사용하여 구하였다. 동일한 시료를 절단하여 TEM, MEIS, 그리고 XRR에 의하여 SiON 박막의 두께를 측정하였으며, 그 결과 SE와 XRR에 의해 얻어진 박막두께가 TEM과 MEIS의 결과 값보다 약 0.5 nm 크게 주어짐을 알 수 있었다(Table 1 참조). 본 연구결과는 비파괴적이며 비접촉식 측정방법인 SE가 2~4nm 두께의 초미세 SiON 박막의 두께와 N 농도의 상대적 값을 빠르고 쉽게 구할 수 있는 유용한 측정방법 임을 보여주었다. 기존의 게이트 산화물인 SiO₂를 대체할 후보 물질들 중의 하나인 A1₂O₃의 유전함수를 구하기 위하여 8 inch, p-type 실리콘 기판 위에 성장된 5 nm, 10 nm, 및 20 nm 두께의 A1₂O₃ 박막의 유전함수와 두께를 측정하였다. 이 시료들에 대한 SE data는 vacuum-UV spectroscopic ellipsometer를 사용하여 세 개의 입사각에서 0.75 eV에서 8.75 eV까지 0.05 eV 간격으로 측정되었다. A1₂O₃ 박막의 유전함수와 두께를 얻기 위하여 공기층/A1₂O₃ 박막/Si 기판으로 구성된 3상계 모델을 사용하였다. Si 기판에 대한 복소 유전함수는 문헌상의 값(1)을 사용하였고, A1₂O₃ 박막의 유전함수는 5개의 미지상수를 갖는 Tauc- Lorentz(TL) 분산함수(2)를 사용하였다. A1₂O₃ 박막의 경우 두께가 증가함에 따라서 굴절률이 커짐을 알 수 있었다.

  • PDF

Studies on the Fouling Reduction through Oxyfluorination of Porous Polyethylene Membranes (함산소불소화법을 통한 다공성 폴리에틸렌막의 파울링현상 감소연구)

  • Kang, Su Yeon;Rhim, Ji Won;Cheong, Seong Ihl
    • Membrane Journal
    • /
    • v.24 no.6
    • /
    • pp.431-437
    • /
    • 2014
  • To overcome the flux reduction due to the fouling by adsorption of foulants onto the porous hydrophobic polyethylene membrane surface, the oxyflorination was introduced to hydrophilize the hydrophobic membranes. After the hydrophilization through oxyfluorination, the contact angle decreased from $93^{\circ}$ to $50^{\circ}$ while the water flux increased to 60%. It was considered that for the model foulants dissolved in water, such as albumin (form bovine serum, BSA), humic acid sodium salt (HA), and alginic acid sodium salt (SA), the flux was enhanced since the adsorbed foulants decreased by the oxyfluorination. Particularly, it was obtained that the water flux was over twice more than the untreated polyethylene membrane in case of SA foulant.

Morphable Model to Interpolate Difference between Number of Pixels and Number of Vertices (픽셀 수와 정점들 간의 차이를 보완하는 Morphable 모델)

  • Ko, Bang-Hyun;Moon, Hyeon-Joon;Kim, Yong-Guk;Moon, Seung-Bin;Lee, Jong-Weon
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.3
    • /
    • pp.1-8
    • /
    • 2007
  • The images, which were acquired from various systems such as CCTV and Robot, include many human faces. Because of a rapid increase in visual data, we cannot process these manually; rather we need to do these automatically. Furthermore, companies require automatic security systems to protect their new technology. There are various options available to us, including face recognition, iris recognition and fingerprint recognition. Face recognition is preferable since it does not require direct contact. However, the standard 2-Dimensional method is limited, so Morphable Models may be recommended as an alternative. The original morphable model, made by MPI, contains a large quantity of data such as texture and geometry data. This paper presents a Geometrix-based morphable model designed to reduce this data capacity.

Analytical Behavior of FRP Girder filled with Concrete (콘크리트로 충진된 FRP 보의 해석을 통한 거동평가)

  • Jeong, Sang-Mo;Park, Dong-Won;Jeong, Yo-Sok;Kim, Hyun-Joon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.245-248
    • /
    • 2008
  • Recently, much research has been conducted on FRP composite to replace steel. However, the concept of FRP girder filled with concrete has not been fully attempted. This study focuses on the analytical behavior of FRP girders filled with concrete. FRP girders usually have large deflection due to relatively low elastic modulus compared to steel members. However, in the previous experimental investigation on small sized modular beams, it has been verified that the displacement of FRP-girder filled with concrete is reduced and the strength is increased considerably. In this research, analytical investigations have conducted to verify the analytical method by comparing the results with tests. In addition, analyses on large girders assembled with small modules have been carried out to predict the feasibility before tests. The analytical results showed that the assembled FRP girders can be used as substitutes for steel girders.

  • PDF

A Study of the Structural Relationship of Corporate e-Learning in Quality, Users' Learning Characteristics and Customer Orientation in Hotel Industry (호텔 e-Learning의 품질 및 사용자 학습특성과 고객지향성과의 구조적 관계에 관한 연구)

  • Ji, Yun Ho;Park, Tae Soo;Kim, Minsun;Moon, Yun Ji
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.575-577
    • /
    • 2013
  • The research was aimed at the hotel industry's employees in order to test the efficiency of e-Learning, which is emerging as the alternative training system to the conventional one. The independent variables are the quality of e-Learning, including the qualities of the system, contents, and service of e-Learning, and the learning characteristic factor, including the quality factor of e-Learning, the self-efficacy of the user, learning motivation, and the flow of learning. Furthermore, the intervening variables are its perceived usefulness and the satisfaction factor of the user known as the so-called utility of e-Learning, continuous intention to use in terms of efficaciousness, and the spread of education and training. The dependent variable is customer orientation, known as the ultimate efficaciousness of corporate e-Learning.

  • PDF

Vision and Depth Information based Real-time Hand Interface Method Using Finger Joint Estimation (손가락 마디 추정을 이용한 비전 및 깊이 정보 기반 손 인터페이스 방법)

  • Park, Kiseo;Lee, Daeho;Park, Youngtae
    • Journal of Digital Convergence
    • /
    • v.11 no.7
    • /
    • pp.157-163
    • /
    • 2013
  • In this paper, we propose a vision and depth information based real-time hand gesture interface method using finger joint estimation. For this, the areas of left and right hands are segmented after mapping of the visual image and depth information image, and labeling and boundary noise removal is performed. Then, the centroid point and rotation angle of each hand area are calculated. Afterwards, a circle is expanded at following pattern from a centroid point of the hand to detect joint points and end points of the finger by obtaining the midway points of the hand boundary crossing and the hand model is recognized. Experimental results that our method enabled fingertip distinction and recognized various hand gestures fast and accurately. As a result of the experiment on various hand poses with the hidden fingers using both hands, the accuracy showed over 90% and the performance indicated over 25 fps. The proposed method can be used as a without contacts input interface in HCI control, education, and game applications.

Safe arm posture when using vertical rescue sack (수직 강하식 구조대 사용 시 안전한 팔 자세)

  • Jeon, Jai-In;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • This study is about the safe arm posture in case of emergency escape using the vertical dive rescue sack at the fire site. The experimental results are as follows. First, the arms extended upward contact with the endothelium and narrowing part of the rescue sack minimized the scratches did not occur. Second, the bent position with both arms open was subject to light abrasions of on the elbows due to friction between the elbows and the scapula and the endothelium. Third, in the posture where both arms were gathered in the chest, the body passed through the narrowing part and friction between the bag's narrowing part, All subjects had light abrasions on their elbows. Fourth, because the arms are lowered, the legs are extended to the width of the shoulders when descending, so that the back of the hand has friction with the narrowing part of the bag and the endothelial skin. Finally, posture with both arms below the front increased the volume of the front of the body, resulting in a slight back injury. As a future research task, it is necessary to study the proper posture of legs and the posture of landing on the ground.

Contact non-linear finite element model analysis of initial stability of mini implant (접촉 유한요소모델을 이용한 미니 임플란트의 초기 응력분포 연구)

  • Yoon, Hyun-Joo;Jung, Ui-Won;Lee, Jong-Suk;Kim, Chang-Sung;Kim, Jung-Moon;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Sung-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.681-690
    • /
    • 2007
  • Mini implants had been used provisionally for the healing period of implants in the beginning. But it becomes used for the on-going purpose, because it is simple to use, economic and especially suitable for the overdenture. But there is few studies about the stability of mini implants, that is most important factor for the on-going purpose, and particularly the implant parameters affecting the initial stability. The purpose of this study was to evaluate the stress and the strain distribution pattern of immediate-loaded screw type orthodontic mini-implant and the parameters affecting the initial stability of immediate-loaded mini-implant. Two dimensional finite element models were made and contact non-linear finite element analysis was performed. The magnitude and distribution of Von Mises stresses were evaluated. The obtained results were as follows: 1. The stress was concentrated on the thread tip of an implant in the cortical bone. 2. The direction of load is the most important factor for the stress distribution in cortical bone. 3. The diameter of an implant is the most important factor for the stress distribution in the trabecular bone. In conclusion, if the horizontal load vector is successfully controlled, mini-implants, which diameter is under 3mm, can be used for the on-going purpose.

Preparation of Poly(ethylenimine) Anionic Exchnage Membrane Impregnated in Porous Polyethylene Membranes (다공성 폴리에틸렌 막에 폴리에틸렌이민을 함침 시킨 음이온교환막의 제조 연구)

  • Park, Chan-Jong;Kim, Il-Hyung;Kim, Sung-Pyo;Lee, Hak-Min;Cheong, Seong-Ihl;Choi, Ho-Sang;Rhim, Ji-Won
    • Membrane Journal
    • /
    • v.21 no.1
    • /
    • pp.91-97
    • /
    • 2011
  • In this study, the anionic exchange membranes were prepared through the impregnation of polyethylenimine (PEI) into porous polyethylene (PE) separator and then crosslinking with isophrhaloyl dichloride (IPC). To characterize the resulting membranes, the contact angles, FT-IR, ion exchnage capacity and ion conductivity were measured. The amide group is produced the reaction between amines in PEI and -COCl in IPC. In case of ion exchange capacity, 1.96 meq./g dry membrane at the reaction time, 30 sec was decreased to 1.14 meq./g dry membrane at 600 sec reaction time. The ion conductivity, $9.15{\times}10^{-2}S/cm$ at 30 sec reaction time, was obtained.