• 제목/요약/키워드: 원전 격납건물

검색결과 83건 처리시간 0.025초

원전 격납건물 비선형 해석을 위할 콘크리트 재료모델 개발 (Development of Concrete Material Model for Nonlinear Analysis of Nuclear Containment Building)

  • 이홍표;전영선;서정문;신재철
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.312-319
    • /
    • 2004
  • This paper is mai y focused to develop new concrete material model such as ultimate failure surface in compression-compression region, hardening rule and cracking criteria which are basically used in the nonlinear finite element analysis of nuclear prestressed concrete containment building. From the Kepri's experimental results, failure surface of the concrete based on the elasto-plastic material model is modified and new cracking criteria is proposed. Nonlinear FE analysis program using a new material model is implemented to analysis plane concrete. Finally, numerical simulation to compare the performance of the new material model with experimental results is employed. The numerical results by the proposed model in this study agree very well with the experimental data.

  • PDF

프리스트레스 콘크리트 원전 격납건물의 비선형 유한요소해석에 관한 연구 (A Study on the Nonlinear Finite Element Analysis of Prestressed Concrete Containment Vessel)

  • 이홍표;전영선;송영철
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.639-646
    • /
    • 2006
  • A nonlinear finite element analysis is carried out to predict the ultimate internal pressure and failure mechanism of a 1/4 scale prestressed concrete containment vessel(PCCV) model using the commercial code ABAQUS. Therefore, this paper is mainly focused to compare the influence of concrete material model, tension stiffening parameter, uplift phenomenon and basemat. From the analysis results, nonlinear behavior of the PCCV showed a substantially different aspects in accordance with the nonlinear material model for the concrete as well as tension stiffening parameter. The boundary conditions beneath the basemat are considered to be a fixed condition and a nonlinear spring element to compare the influence of the uplift. The finite element analysis is considered with and without a basemat to find out the influence of the basemant itself. From the analysis results, the nonlinear behavior of the PCCV is entirely similar for the two cases.

  • PDF

한국형 원전 격납건물의 비선형해석에 관한 연구 (A Study on the Nonlinear Analysis of Containment Building in Korea Standard Nuclear Power Plant)

  • 이홍표;전영선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.694-697
    • /
    • 2007
  • In this paper, a nonlinear finite element analysis program NUCAS, which has been developed for assessment of pressure capacity and failure mode for nuclear containment building is described. Degenerated shell element with assumed strain method and low-order solid element with enhanced assumed strain method is adapted to microscopic material and elasto-plastic material model, respectively. Finally, the performance of the developed program is tested and demonstrated with several examples. From the numerical tests, the present results show a good agreement with experimental data or other numerical results.

  • PDF

미시적 재료모델을 사용한 원전 격납건물 벽체 요소의 구조거동 분석 (On the investigation of structural behaviour of nuclear containment building wall element using microscopic material model)

  • 이상진;이홍표;서정문
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 가을 학술발표회논문집
    • /
    • pp.217-221
    • /
    • 2000
  • Nonlinear stress analysis of nuclear containment building wall element is carried out using microscopic material model. The present study mainly focuses on the finite element analysis of the nuclear containment building wall element under biaxial tensile stresses and it evaluates the perfomance of adopted microscopic material model in the membrane energy dominant situation. From the numerical analysis, the adopted material model peforms well and has a good agreement with experiment result. Finally, the result of present study can be severed as a benchmark test when concrete material model is in need of evaluation.

  • PDF

상용프로그램(ABAQUS)을 이용한 원전 격납건물 RC Panel의 극한 인장해석 (Ultimate Tensile Analysis of Reinforced Concrete Containment Panel by using ABAQUS Program)

  • 김남식;정대성;김광수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.577-584
    • /
    • 2003
  • Tension tests of half-thickness concrete containment wall elements and material tests were conducted to derive a crack pattern and constitutive law of concrete. Main test variables are reinforcement ratio and the applied load ratio in two direction, and its effect on the behavior of reinforced concrete panel subjected to biaxial tension is investigated. Based on the test results, analytical expression is derived for the stress-strain relationship of concrete in tension. Ultimate analyses of reinforced concrete panels are carried out by a general purpose structural analysis computer program(ABAQUS), and its results are compared with the test results. The present analysis focuses on the effects of pre-analysis prior to test of specimens. These ultimate tensile analyses as pre-analysis are essential and important to design an effectual scheme of test.

  • PDF

원전 격납건물 돔 텐던의 축대칭 근사화에 대한 타당성 고찰 (Verification for Axisymmetric Modeling of Dome Tendons in Nuclear Containment Building)

  • 전세진;정철헌;김영진;정연석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.81-84
    • /
    • 2004
  • Prestressing tendons in a nuclear containment building dome are non-axisymmetrically arranged in most cases. However, simple axisymmetric modeling of the containment has been often employed in practice, which requires the axisymmetric approximation of the actual tendon arrangements in the dome. A procedure was previously proposed that can implement the actual 3D tendon stiffness and prestressing effect into the axisymmetric model for CANDU type. This paper further verifies and compares some methodologies adopted in the proposed scheme through some numerical examples.

  • PDF

원전 부착식 텐던 격납건물의 구조거동 분석기법 개발 I-CANDU형 (Development of Analysis Technique for Structural Behavior of Containment with Bonded-Type Tendons (CANDU Type))

  • 이상근;박상순;이상민;조명석;송영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.643-646
    • /
    • 2004
  • The posttensioning system of nuclear containment have to be verified its structural integrity by the periodic inspection because the structural behavior of the containment is changed by the variation of the physical property of concrete and tendon as time passes. In this study a program 'SAPONC-CANDU' which is able to monitor and analysis the micro structural behavior of the domestic CANDU type containment at all times was developed. The readings of vibrating-wire strain gauges embedded into the concrete of containment were used as input data for operating the program. This program provides the long-term prediction values and bands of the concrete strain due to the time dependent factors of the concrete and tendon of the domestic CANDU type containment.

  • PDF

원전 부착식 텐던 격납건물의 구조거동 분석기법 개발II - FRANCE형 (Development of Analysis Technique for Structural Behavior of Containment with Bonded-Type Tendons (FRANCE Type))

  • 이상근;박상순;이상민;우상균;송영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.671-674
    • /
    • 2004
  • In this study a program 'SAPONC-FRANCE' which is able to evaluate and analysis the elastic behavior property of the domestic FRANCE type containment under pressurization and depressurization in periodic structural integrity test (SIT) was developed. The readings of EAU system that is composed of the pendulum, invar-wire, leveling-pot, bench-mark, thermocouples and acoustic strain gauges were used as input data for operating the program. This program provides the prediction lines and bands of the pressure-strain(or displacement) relationship of concrete due to the changing of inner volume under pressurization and depressurization in SIT of the domestic FRANCE type containment.

  • PDF

7m 원격 무선전력전송 개발 사례 (Development of 7m-off-Long-Distance Wireless Power Transfer System)

  • 최보환;이은수;김지훈;임춘택
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.7-8
    • /
    • 2014
  • 본 논문은 다이폴 코일 공진방식(DCRS, Dipole Coil Resonant System)을 사용한 원격 무선전력전송 개발 사례를 소개한다. 제안된 다이폴 코일 공진방식은 기존의 자기결합 공진방식(CMRS, Coupled Magnetic Resonance System)에 비하여 송신, 수신코일로만 이루어진 간단한 코일 구조와 작은 부피를 가지며, 공진도 Q를 100이하로 설계하여 주변 환경 변화에 강인한 전력전달 특성을 가진다. 본 논문에서는 원전 중대사고 시 격납건물 필수계측기용 소형 비상전원으로 개발된 10W급 7m 원격 무선전력전송 장치의 구성 및 설계과정을 제시한다.

  • PDF

원전기기의 면진을 위한 진동대 실험 I : 고무베어링 (A Shaking Table Test for Equipment Isolation in the NPP (I): Rubber Bearing)

  • 김민규;전영선;최인길
    • 한국지진공학회논문집
    • /
    • 제8권5호통권39호
    • /
    • pp.65-77
    • /
    • 2004
  • 본 연구에서는 원전기기의 내진안전성을 향상시키기 위한 진동대 실험을 수행하였다. 원전 격납건물과 유사한 진동수 특성을 가지는 구조물을 제작하여 실험에 사용하였으며 구조물 내부에 설치된 기기를 모사 하기 위하여 면진장치가 설치된 강체블럭을 층바닥에 설치하였다. 주파수 특성이 상이한 3종류의 지진파를 이용하여 진동대 실험을 수행하였다. 면진장치로는 천연고무베어링(NRB)과 고감쇠고무베어링(HDRB)을 사용하여 고무의 감쇠특성에 따른 면진기기의 효율성을 분석하였다. 또한 입력지진동의 주파수 특성에 따라 적절한 면진장치의 기기면진효과를 평가하였다. 실험결과 적절한 면진장치를 사용함으로써 기기의 지진응답을 크게 줄일 수 있으며 지진에 대한 안전성을 향상키킬 수 있는 것으로 나타났다.