• Title/Summary/Keyword: 원스캔

Search Result 200, Processing Time 0.031 seconds

Scan Blindness Analysis of 1D and 2D Ka-Band Printed Dipole Array Antenna (일차원과 이차원 Ka-대역 프린티드 다이폴 배열 안테나의 스캔 블라인드니스 분석)

  • Koo, Hanni;Song, Sungchan;Nam, Sangwook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.3
    • /
    • pp.202-208
    • /
    • 2019
  • In this study, an active element pattern (AEP) of a printed dipole was analyzed in 1D and 2D arrays. First, an AEP of the printed dipole was obtained using the simulation in the 2D infinite array. The scan blindness in the 2D array occurred in the E-plane direction at around ${\pm}36^{\circ}$; however, it was barely observed in the 1D array. To analyze the cause of the scan blindness in the 2D array, the dispersion properties of a unit cell was obtained and compared with the scan blindness by frequency change. The difference between the scan blindness of the 1D and 2D arrays was clarified using the comparison of the Q value in the unit cell in the 1D and 2D arrays. Then, the coupling of the electric field in the E-plane direction was observed when nine elements were separated between the two ports in a linearly arranged dipole structure. Finally, the printed dipole array was fabricated, and an AEP was measured for the $11{\times}1$ and $11{\times}3$ sub arrays. The proposed theory was verified using these observations and by comparison with the simulation results.

Circle center detection with rotational scans (회전 스캔 방식을 이용한 원 중심 인식 방법)

  • Bae, Joung Eun;Cho, Hyun Zi;Yoo, Hoon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2017.06a
    • /
    • pp.74-75
    • /
    • 2017
  • 원의 대칭을 이용하는 회전 스캔 방식으로 원의 중심을 인식하는 기술을 제안한다. 컴퓨터 비전에서 원을 인식하는 기술은 매우 중요한 기술이다. 원 인식 기술은 높은 정확성을 위해 계속해서 연구되어왔다. 기존의 대표 기술인 Circle Hough transform(CHT)은 원을 인식하기 위해서 3차원의 축적 배열이 필요하며 실영상에서 원근 왜곡이 있는 경우에는 원이 인식되지 않는다. 원근 왜곡이 있는 경우에도 원 중심을 인식 할 수 있는 회전 스캔 방식을 제안한다. 제안하는 기술의 정확성을 입증하기 위해서 기존 기술 중 하나인 Open CV가 제공하는 gradient-CHT기술과 비교하는 실험을 진행하였다. 실험 결과는 제안하는 기술이 Open CV보다 우수하다는 것을 보여준다.

  • PDF

스터드 기반의 레이저 레이다 삼차원 영상센서기술

  • Min, Bong-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.120-120
    • /
    • 2013
  • 본 발표에서는 최근 무인전투기 및 무인자율주행차량 등의 어플리케이션에 응용되고 있는 삼차원 영상 센서 시스템 기술에 관한 소개와 더불어 한국전자통신연구원에서 독자적인 구도를 기반으로 최근 시연에 성공한 스터드(STUD) 레이저 레이다의 동작원리 및 구현결과를 소개하고자 한다. 최근 전세계의 삼차원 레이저 영상 센서 시스템은 1) 한 관측점을 회전을 통해 스캔하는 2D 스캔 방식에서 벗어나, 2) 일차원 배열 형태로 구현된 관측점을 센서가 회전하면서 얻어지는 3D 스캔 방식과 3) 이차원 어레이 형태의 검출기로 삼차원 영상을 검출하는 방식으로 삼차원 영상을 확보하는 노력으로 구분되어 진행되어 왔다. 이번 시연에 성공한 제안된 방법은, 기존의구도와는 다른 독자적인 방식으로, 대면적 검출기를 기반으로 센서부가 회전하지 않으면서, 하나로 통합된 검출기 출력을 이용할 수 있는 구도인 스터드(STUD: STatic and Unitary Detector)기반의 삼차원 레이저 레이다 시스템이다. 최근 구현 결과는 수평해상도 320, 수직해상도 240인 QVGA 영상 수준으로, 이는 지금까지 세계 최고해상도인 ASC사의 128x128 해상도를 뛰어 넘는 우수한 결과이다. 제안된독자적인 구도의 삼차원 레이저 영상 시스템은 다양한 관련 기술들과의 접목하여 향후 군수용 뿐만아니라 민수용 시장의 기술발전에 큰 영향을 미칠 것으로 예상되고 있다.

  • PDF

Multi-Channel Single-Pass Connected Components Labeler (다채널 동작이 가능한 단일-스캔 연결 성분 라벨러)

  • Jeong, Jae-Won;Shin, Youn-Chul;Park, Joo-Heon;Lee, Myeong-Jin
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.06a
    • /
    • pp.87-89
    • /
    • 2013
  • 기존의 영상 라벨러는 이중 스캔 연결 성분 라벨링 방식이 주로 사용되어 왔다. 그러나, 이중 스캔 연결 성분 라벨링 방식은 별도의 라벨 병합 구간 때문에 실시간 처리와 다채널 처리가 어렵다. 최근 단일 스캔 연결 성분 라벨링 방법들이 제안되었지만, 이들 역시 스캔 횟수는 줄일 수 있으나 별도의 라벨 병합 구간을 제거하지는 못하였다. 본 논문에서는 별도의 라벨 병합 구간을 갖지 않는 단일 스캔 연결 성분 라벨러 구조를 제안한다. 제안하는 구조는 라인 스캔과 동시에 라벨 병합이 이루어지기 때문에 고속 동작하고, 예상 가능한 프레임 처리율을 가지며, 다채널 처리가 가능하다. 제안하는 라벨러 구조는 FPGA로 설계되었고 동작이 검증되었으며, 성능 실험을 통해 고속 동작과 다채널 영상 처리에 적합함을 확인하였다.

  • PDF

Scan Chain Modification for Low Power Design (저 전력을 고려한 스캔 체인 수정에 관한 연구)

  • Park Susik;Kim Insoo;Jung Sungwon;Min Hyoung Bok
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11a
    • /
    • pp.835-837
    • /
    • 2005
  • 이동기기들이 늘어가고 있는 추세에서 기기들의 구성품인 디지털 회로들의 테스트 시간과 전력소모는 성능에 상당한 영향을 미친다. 테스트 시간을 줄이는 방법은 병렬 코어 테스트 방법으로 줄일 수 있으나, 다양한 코어들이 동시에 테스트 되면 많은 전력 소모를 야기 시킨다. 스캔 구조를 기반으로 한 회로에서 전력 소모는 테스트 데이터의 불필요한 천이에 의해 많이 발tod한다. 그러므로 스캔 체인을 수정함으로 인해 입력 값과 출력 간의 천이를 줄일 수 있다. 제안하는 스캔 체인의 수정은 스캔 셀의 재배치와 특정한 회로의 추가로 이루어진다. 또한 회로의 추가는 그에 적합한 그룹화를 시킴으로써 최소의 수를 결정한다. 천이 주기를 해석하여 효과적인 알고리즘을 세움으로써 최적의 스캔 체인구조와 그룹을 구함으로써 전력 소모를 최소화할 수 있다.

  • PDF

The Usefulness of $^{99m}Tc$-Sestamibi Scan in Preoperative Localization in Primary Hyperparathyroidism (원발성 부갑상선 기능 항진증의 수술전 병소확인에서 $^{99m}Tc$-Sestamibi 스캔의 유용성)

  • Baik, S.H.;Kim, S.M.;Choi, K.M.;Choi, Y.S.;Kim, S.J.;Yu, J.M.;Choi, D.S.;Choe, J.C.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.465-472
    • /
    • 1995
  • An accurate preoperative localization in patients with primary hyperparathyroidism is important for successful surgical intervention. There are many methods for the localization of the primary hyperparathyroidism such as ultrasonography, computerized tomography(CT), magnetic resonance imaging(MRI), angiography and $^{201}T1/^{99m}Tc$ subtraction scan. Among them $^{201}T1/^{99m}Tc$ subtraction scan is known as the most accurate tool for preoperative localization. Recently $^{99m}Tc$-Sestamibi has been used for parathyroid gland imaging. We experienced 19 primary hyperparathyroidisms accurately localized with $^{201}T1/^{99m}Tc$ subtraction imaging and $^{99m}Tc$-Sestamibi. The sensitivities of the $^{99m}Tc$-Sestanibi, $^{201}T1/^{99m}Tc$ subtraction imaging, CT and US were 100%(5/5), 89.5%(17/19) and 61.7(12/19) respectively. With the combination of $^{99m}Tc$-Sestamibi and $^{201}T1/^{99m}Tc$ subtraction imaging we could localize with 100% accuracy. Although the case number is small, this study suggests that the $^{99m}Tc$-Sestamibi parathyroid scan is very useful and easy to use for preoperative localization in primary hyperparathyroidism.

  • PDF

A Join Processing Technique using Sorted Index Scan (정렬 인덱스 스캔을 이용한 조인기법)

  • Lee, Jong-Baek;Kang, Woon-Hak;Lee, Sang-Won
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06c
    • /
    • pp.16-18
    • /
    • 2012
  • 플래시메모리는 빠른 성능 및 저전력 등 여러 가지 장점 덕분에 저장장치 시장에서 최근 빠른 속도로 하드디스크를 대체해 가고 있다. 특히, 엔터프라이즈 데이터베이스 분야에서 가격 대비 성능 면에서 효과가 높기 때문에 더 주목을 받고 있다. 데이터베이스 분야에서 조인은 가장 자주 사용되는 연산으로 그 성능 개선이 중요한데, 본 논문에서는 플래시메모리를 위한 새로운 조인 처리의 한 방법으로 정렬 인덱스 스캔 방식을 활용하는 방안은 제시한다. 정렬 인덱스 스캔은 최근 플래시메모리 상에서 테이블에 대한 접근 방식의 하나로, 조인결과의 정렬을 고려할 경우, 기존의 전체 테이블 스캔에 기반을 둔 해시조인이나 정렬합병조인과 비교했을 때 상당한 성능 개선을 보장한다.

Diagnostic Role of Tc-99m MIBI Scintimammography in Suspected Breast Cancer Patients: Results of Unicenter Trial (유방암이 의심되는 환자에서 Tc-99m MIBI 유방스캔의 진단적 역할: 단일기관의 결과)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.234-242
    • /
    • 2000
  • Purpose: Tc-99m MIBI scintimammography has been validated as an useful non-invasive diagnostic tool for the primary breast cancer. But most studies have included small population of patients. We have experienced a large study population and investigated the diagnostic usefulness of Tc-99m MIBI scintimammography in detection of primary breast cancer and axillary lymph node metastasis. Materials and Methods: This study included 305 patients who underwent scintimammogtaphy for palpable breast masses or abnormal radiologic findings. Tc-99m MIBI scintimammography was performed 10 minutes after intravenous injection of 925 MBq of Tc-99m MIBI. If the early image revealed abnormal finding, 3 hour delayed image was also acquired. We calculated early and delayed lesion to non-lesion ratios (L/N). The pathologic diagnosis was obtained from surgical operation or FNAB and compared with the results of Tc-99m MIBI scintimammography. Results: Malignant breast diseases were 155 and benign ones were 150. Tc-99m MIBI scintimammography revealed 132 true positive, 23 false negative, 10 false positive, and 140 true negative cases. The sensitivity, specificity, positive predictive value and negative predictive value for the primary breast cancer detection were 85.2%, 93.4%, 92.9%, and 85.9%, respectively. The sensitivity, specificity, positive predictive and negative predictive values of Tc-99m MIBI scintimammography in detecting metastatic axillary lymph node involvement were 22%, 90.4%, 61.9% and 62.3%, respectively. Early L/N of malignant breast disease was significantly higher than that of benign one ($2.44{\pm}0.97\;vs\;1.94{\pm}0.78$, p=0.01). Delayed L/N had no significant difference between malignant and benign breast diseases ($1.94{\pm}0.52\;vs\;1.91{\pm}0.73$, p=0.43). Conclusion: Our study revealed that Tc-99m MIBI scintimammography was an useful diagnostic tool for the diagnosis of breast cancer. And early L/N ratio might provide complementary role in the detection of breast cancer. But the Tc-99m MIBI scintimammography had limited value in the detection of small breast cancer (less than 1 cm) and axillary lymph node metastasis.

  • PDF

A Study on the Simulated Radar Terrain Scan Data Generated from Discrete Terrain (이산지형정보에서 생성된 레이다 모의 지형 스캔 정보에 관한 연구)

  • Seunghun, Kang;Sunghyun, Hahn;Jiyeon, Jeon;Dongju, Lim;Sangchul, Lee
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.6
    • /
    • pp.1-7
    • /
    • 2022
  • A simulated radar terrain scan data generation method is employed for terrain following. This method scans the discrete terrain by sequentially radiating beams from the radar to the desired scan area with the same azimuth but varying elevation angles. The terrain data collected from the beam is integrated to generate the simulated radar terrain scan data, which comprises radar-detected points. However, these points can be located far from the beam centerline when the radar is far from them due to beam divergence. This paper proposes a geometry-based terrain scan data generation method for analysing simulated radar terrain scan data. The method involves detecting geometric points along the beam centerline, which forms the geometry-based terrain scan data. The analysis of the simulated radar terrain scan data utilising this method confirms that the beam width effects are accounted for in the results.