• Title/Summary/Keyword: 원수수질

Search Result 204, Processing Time 0.03 seconds

Influencing Factors on Sensitivity of Pressure Decay Test for Membrane Damage Assessment (막 손상 측정을 위한 압력손실시험의 감도에 영향을 미치는 인자)

  • Lee, Yong-Soo;Kim, Hyung-Soo;Kim, Jong-Oh
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.367-373
    • /
    • 2017
  • Pressurized membrane module systems, including hollow fiber type of Microfiltration (MF) and Ultrafiltration (UF) membranes are being increasingly used in drinking water treatment due to their high removal efficiency of pathogen. However, when fibers are damaged in pressurized membrane system, the pathogen will be able to penetrate the membrane. Therefore, it is essential to guarantee the regulatory requirements for water quality by an effective on-line or off-line condition integrity monitoring methods. Recently, pressure decay test (PDT) which is one of membrane integrity tests has been reflected to drinking water treatment plants using pressurized membrane module. In this paper, three different method were used to perform PDT and three different sensitivity values were analyzed through experiments. Three types of direct integrity test methods were applied to pressure feed side, filtrate side and bidirectional pressure decay test. The results of these experiments show that the sensitivity was increasing when the volume of pressurized gas was decreasing. The sensitivity is inversely proportional to the gas volume. Furthermore, it is desirable to increase pressure difference between feed side and permeate side in order to achieve higher sensitivity in the PDT by membrane damage.

Synthesis of Polyamine Type Flocculant and Properties in Potable Water Treatment (Polyamine계 고분자 응집제의 합성 및 상수 처리 특성)

  • Park, Lee-Soon;Shin, June-Ho;Choi, Sang-June;Shin, Myung-Chul;Lee, Seok-Hun
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.542-547
    • /
    • 1998
  • Polyamine type polymer flocculants were synthesized and their characterization, viscosity and flocculation studies were conducted. In order to increase the molecular weight of polyamine flocculant which was prepared by polycondensation reaction from dimethylamine and epichlorohydrin, a small amount of 1,6-hexanediamine was employed. The incorporation of 1,6-hexanediamine up to 5.5 mole % replacing corresponding part of dimethylamine gave a branched type polyamine sample with increased intrinsic viscosity ([${\eta}$]=0.46 in 1 wt % aqueous NaCl solution). The amount of 1,6-hexanediamine above 5.5 mole %, however, resulted in gelation during polymerization. Utilizing raw water from Maegok potable water treatment plant, it was found that the addition of polyamine flocculant at a concentration of 1 mg/L level could reduce the amount of polyaluminum chloride (PAC) inorganic flocculant by half (15 mg/L). It was also observed that the incoporation of polyamine flocculant at 1 mg/L level was effective in the higher pH raw water, while PAC inorganic flocculating agent alone was not effective.

  • PDF

A Study on the Optimum Design of Horizontal Collectors in Floodplain Filtration (홍수터여과에서 집수관의 최적설계 연구)

  • Pi, Seong-Min;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.430-437
    • /
    • 2012
  • In order to obtain information on the design parameters of the horizontal laterals in floodplain filtration, laboratory-scale sand-box experiments were performed where the head distributions on the laterals and the groundwater profiles were measured according to the change in parameters including lateral diameter, hydraulic conductivity of the sand, water level at the well and raw-water supply rate. Measured data were analyzed using a numerical code in order to identify the discharge intensity distribution along the laterals. It was observed from the result that the lowering of the water level at the well had minimal adverse effect on the performance of the floodplain filtration. Results also elucidated that the low conveyance of the laterals to transmit the filtrate was compensated and supplemented by a natural augmentation in horizontal conveyance through the aquifer when the raw-water supply rate exceeded the adequate recovery rate. With this mechanism, the water quality is expected to improve further since the travel distance through the aquifer is amplified. Based on these findings it can be suggested that the diameter of the lateral used in the floodplain filtration may be smaller than those in riverbank/bed filtration. It was also found that the ratio between the head loss occurring in a lateral and the total head loss in the floodplain filtration was proportional to the exit velocities of the laterals, which may be used to design and/or evaluate the lateral in floodplain filtration.

Pre-Coagulation and Pre-Ozonation for Ozone Resisting Microfiltration Membrane Filtration System of a High Humic Contained Surface Water (고농도 휴믹성분이 포함된 강 원수에서 응집-침전 및 오존 공정을 전처리로 적용한 오존 내성막 pilot plant에서의 운전성 및 투과수 수질변화에 관한 연구)

  • Lee, Sanghyup;Yoshimasa, Watanabe;Lee, Seockheun;Ahn, Kyuhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.598-607
    • /
    • 2004
  • In this study, the effects of two pre-treatment processes were observed prior to membrane filtration: pre-coagulation and pre-ozonation. To compare the effect of two above-mentioned pre-treatments, we adopted the four schemes: first one is direct membrane filtration of river surface water, second one is membrane filtration after pre-coagulation, third one is membrane filtration after pre-ozonation and fourth one is membrane filtration after pre-coagulation and pre-ozonation. There are two exceptional characteristics in applied processes. One is the usage of the MF membrane which has high ozone resisting characteristic. Therefore, ozone resides in membrane module during filtration. The other is adoption of Jet Mixed Separator (JMS) as coagulation-sedimentation process. The change in transmembrane pressure and permeate water quality were also examined. As a result, considering the filtration performance efficiency and permeate water quality, the process composed of filtration with combination of both pre-coagulation and pre-ozonation was proved most effective. The improved efficiency was due to the reduction of loading rate of fouling inducing materials to membrane module by coagulation process as well as variable reactions, such as degradation, particle destabilization and coagulation, occurred by residual ozone in membrane module. The additional effect of pre-coagulation before pre-ozonation is suppression of AOC, one of the by-products induced by ozonation. Therefore, combination of pre-coagulation and pre-ozonation is the effective process to overcome the major de-merit of ozonation i.e. by-products formation.

Site Suitability Analysis for Riverbank Filtration Using Game Theory (게임이론을 활용한 강변여과 개발 적지선정)

  • Lee, Sang-Il;Lee, Sang-Sin
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.1
    • /
    • pp.95-104
    • /
    • 2010
  • The tap water supply in Korea mainly depends on the surface water. However, the advanced water purification process becomes a necessity due to the deterioration of surface water quality and the risk of accidental spill. High cost of water treatment and public concerns make the decision makers turn to riverbank filtration as an alternative to the surface water. Riverbank filtration has been employed for water supply in many developed countries for more than 150 years. In Korea, riverbank filtration has drawn attention since 1990s as a supply source having potential to stably meet the ever-increasing water demand. Some cities located in the Nakdong River Basin are currently supplying water through riverbank filtration. This work studies the site suitability analysis for riverbank filtration using game theory. Theory of games, which is a branch of applied mathematics used in social sciences (most notably economics), biology, engineering and computer science, was applied to candidate locations for the selection of riverbank filtration site. We proposed a policy game model as a new method adopting a probabilistic approach. The model developed turned out to be an effective tool for site selection.

Evaluation of Pre-ozone Treatment and Economic Efficiency as Changing Raw Water Quality (상수원수 수질변화에 따른 전오존 처리효과 및 경제성 평가)

  • Choi, Dong-Hoon;Park, Jin-Sik;Moon, Choo-Yeun;Lee, Jae-Yong;Ryu, Dong-Choon;Jang, Seong-Ho;Kwon, Ki-Won;Lee, Soo-Ae
    • Journal of Environmental Science International
    • /
    • v.22 no.4
    • /
    • pp.453-461
    • /
    • 2013
  • This study, changes in raw water quality is to indicate on the efficiency of ozone treatment of each pollutant as compared to derive the appropriate operating measures. The appropriate selection for injection rate of pre-ozone and did not inject pre-ozone assess changes in the water. When good water quality, you not injected of pre-ozone to evaluate the economic efficiency of electricity and put the most cost-effective ozone concentration were evaluated. Evaluation remove organic matter and chlorophyll-a concentration level in experiments with each factor of the water DOC> 2.5 mg/L, THMFP> 70 ${\mu}g/L$, Chl-a> 30 $mg/m^3$or less constant process, if you do not need to put pre-ozone showed little impact. It also does not put you in pre-ozone appropriate produce enough power rate savings was calculated as approximately 90 million won. Ability to remove organic materials and the ability to produce disinfection byproducts, and cost-effective decisions by considering the concentration of injection if pre-ozone 1 mg/L was investigated by the appropriate concentration of ozone injection.

Ionic Characteristics of the Ground Water for Hydroponics in Kyeongnam Area (경남지역 양액재배용 지하수의 이온 분포특성)

  • 이영한;전성건;황연현;조강희;신원교
    • Journal of Bio-Environment Control
    • /
    • v.7 no.3
    • /
    • pp.246-252
    • /
    • 1998
  • This study was carried out to investigate the quality of ground water for hydroponics in Kyeongnam area in 1995. Water samples were collected and analyzed from 77 wells in green houses throughout Kyeongnam area. The values of several components in well water were as follows ; 7.4 in pH, 0.46dS/m in EC, 0.3mg/L in N $H_{4}$-N, 25.4mg/L in $Ca^{2+}$, 42.6mg/L in C $l^{[-10]}$ and 72.5mg/L in S $O_{4}$$^{2-}$. The pH value showed high positive significance of correlationships with $Ca^{2+}$ and EC. Also, the EC value showed high positive significance with N $a^{+}$, $Ca^{2+}$, S $O_{4}$$^{2-}$, $Mg^{2+}$ and C $l^{[-10]}$ .

  • PDF

Effect on phytoplankton and seletive withdrawal by Hydraulic-Gun-Aerators in H Reservoir (인공순환에 의한 H호 식물플랑크톤과 선택취수에 대한 영향)

  • Choi, Il-Hwan;Shin, Jae-Ki;Sohn, Byeong-Yong;Baek, Kyoung-Hee;Lee, Kyeong-Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1333-1337
    • /
    • 2006
  • 표층수를 주요 취수원으로 활용하는 우리나라의 경우 저수지 내 남조류 대발생시 주로 인공순환에 의한 제어방안을 적용하고 있다. 본 연구에서는 간헐식 폭기장치를 사용중에 있는 H호를 대상으로 식물플랑크톤 제어 효과를 평가하고, 이에 따른 식물플랑크톤의 수직적 분포와 선택 취수와의 연관성을 규명하여 정수장 유입 원수의 수질을 향상하고자 하였다. 2005년 H호의 남조류 농도는 최대 $1.2mg/m^3 $ 수준으로 낮은 분포로 조사되었다. 남조강에 대한 폭기 효과는 6월에는 워낙 그 농도가 낮아 효과 분석 자체가 무의미 하였으나, 10월에는 비영향지점 보다 영향지점의 최대 농도가 약 28% 저감되는 효과를 확인하였다. 조사 기간 중 가장 높은 농도를 보인 조류강은 Cryptophyta이었으며 6월9일에 약 $5mg/m^3$ 농도로 측정되었다. 10월6일에는 Diatom, Bluegreen, Green algae, Cryptophyta가 비슷한 농도 분포로 혼재된 양상을 보였다. 다른 조류강의 경우 조사 기간 중 $3mg/m^3$ 이하의 농도로 측정되었다. 취수탑을 중심으로 설치하여 운영하는 간헐식 폭기장치 1기의 유효 영향 범위를 조사하기 위하여 폭기 영향권에서 식물플랑크톤 분포를 submersible fluorescence probe로 현장에서 실시간으로 조사한 결과 식물플랑크톤 밀도는 감소하고 수직적인 분포층은 깊어지는 현상을 보였다. 이러한 효과를 보이는 거리는 폭기 장치로부터 약 50m로 나타났으며 pH, DO, 수온항목의 결과에서도 같은 현상을 보였다. 이 결과에 따르면 현재 설치된 총 7기의 폭기 장치의 유효영향 범위는 최대 $0.07km^2$ 면적에 그 효과를 기대할 수 있을 것으로 판단되어, 남조 수화현상이 심화될 경우 인공순환에 의한 저감효과가 크지는 않을 것으로 예측된다. 조사 기간중 H호의 현존 식물플랑크톤량의 $60%{\sim}87%$가 수심 10m 이내에 분포하였고, 녹조강과 남조강이 우점하는 하절기에는 5m 이내에 주로 분포하였다. 취수탑 지점의 수심이 연중 $25{\sim}35m$를 유지하는 H호의 경우 간헐식 폭기장치를 가동하는 기간은 물론 그 외 기간에도 취수구의 심도를 표층 10m 이하로 유지 할 경우 전체 조류 유입량을 60% 이상 저감할 수 있을 것으로 조사되었다.

  • PDF

Effect of Shifts in Food Waste Policy on the Municipal Solid Waste Composition (음식물 폐기물 정책 변화가 도시생활폐기물의 조성변화에 미치는 영향)

  • Yoon, Seok-Pyo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.1
    • /
    • pp.39-45
    • /
    • 2008
  • As a waste management tool, the prohibition of landfilling of food waste has enforced since 2005. the composition of municipal solid waste (MSW) has changed dramatically. In this study, MSW generated from a small city collected once a year in 2004, 2005 and 2007, to qualify the characteristics of MSW before and after implementation of the tool. The prohibition of landfilling of food waste dramatically reduces food waste in MSW to 5.5 weight %, and on the other hand results to increase papers to 50.6 % and plastics to 22.6 %, The bulk density lowers to 50 %, which newly propose the necessity of volume reduction and incineration of MSW to ensure efficient transport and disposal. As water content of MSW reduces to 15.9 %, lower heat value of MSW after prohibition of landfilling of food waste increase to 3565.6 kcal/kg. Mitigation of bad smell and waste leachate with lower contaminants are recommendable as a kind of positive effects benefited by the tool.

  • PDF

Optimization of Coagulation and Media Filtration Process for Low Turbidity Seawater (저탁도 해수원수 특성에 적합한 응집 - 여과 공정의 최적화)

  • Son, Dong-Min;Jo, Myeong-Heum;Kim, Jeong-Sook;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.251-257
    • /
    • 2014
  • This research is focused on coagulation and sand filtration process as a pretreatment of RO seawater desalination. RO systems require sufficient and reliable pretreatment process to produce superior quality of RO feedwater that can mitigate RO membrane fouling. This experiment was conducted to investigate the effectiveness of coagulation and filtration process under various experimental conditions including different coagulant dose, flocculation mixing intensity and time, turbidity, and filtration rate. The experimental results showed that the optimum pretreatment conditions resulting in lower SDI value suitable for RO feedwater were coagulation pH 6.5, raw water turbidity greater than 4 NTU, and media bed depth greater than 550 mm. However, flocculation mixing intensity, coagulant dose, and filtration rate relatively affected little on the filtration efficiency.