Abstract
Pressurized membrane module systems, including hollow fiber type of Microfiltration (MF) and Ultrafiltration (UF) membranes are being increasingly used in drinking water treatment due to their high removal efficiency of pathogen. However, when fibers are damaged in pressurized membrane system, the pathogen will be able to penetrate the membrane. Therefore, it is essential to guarantee the regulatory requirements for water quality by an effective on-line or off-line condition integrity monitoring methods. Recently, pressure decay test (PDT) which is one of membrane integrity tests has been reflected to drinking water treatment plants using pressurized membrane module. In this paper, three different method were used to perform PDT and three different sensitivity values were analyzed through experiments. Three types of direct integrity test methods were applied to pressure feed side, filtrate side and bidirectional pressure decay test. The results of these experiments show that the sensitivity was increasing when the volume of pressurized gas was decreasing. The sensitivity is inversely proportional to the gas volume. Furthermore, it is desirable to increase pressure difference between feed side and permeate side in order to achieve higher sensitivity in the PDT by membrane damage.
Keywords
Membrane Integrity Test; Pressure Decay Test; Volumetric Analysis; Pressure Difference; Initial Pressure Value;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 USEPA, "Membrane Filtration Guidance Manual", USEPA 815-R-06-009 (2005).
2 J. Naismith, "Membrane integrity-direct turbidity measurement of filtrate from MF membrane modules at an operating potable water treatment plant", Desalination, 179, 25 (2005).   DOI
3 J. H. Lee, S. K. Hong, H. C. Hur, K. J. Lee, and Y. J. Choi, "Sensitivity analysis of initial pressure and upper control limit on the pressure decay test for membrane integrity evaluation", Sujil Bojeon., 179, 793 (2008).
4 H. Guo, Y. Wyart, J. Perot, F. Nauleau, and P. Moulin, "Low-pressure membrane integrity tests for drinking water treatment: A review", Water Res., 44, 41 (2010).   DOI
5 S. J. You, H. W. Ahn, S. H. Park, J. L. Lim, S. C. Hong, and P. I. Yi, "The study on optimum operation conditions of ceramic MF membrane process in Y water treatment plant", Membr. J., 24, 201 (2014).   DOI
6 S. Wang, X. Lu, N. Zhou, W. Xiong, Q. Zhang, and Z. Yang, "Quantification of the defect size of ultrafiltration membrane system using mathematical model", Desalination, 367, 172 (2015).   DOI
7 M. L. Pype, B. C. Donose, L. Martí, D. Patureau, N. Wery, and W. Gernjak, "Virus removal and integrity in aged RO membranes", Water Res., 90, 167 (2016).   DOI
8 A. Liden, E. Lavonen, K. M. Persson, and M. Larson, "Integrity breaches in a hollow fiber nanofilter- Effects on natural organic matter and virus- like particle removal", Water Res., 105, 231 (2016).   DOI
9 K. Farahbakshs and D. W. Smith, "Estimating air diffusion contribution to pressure decay during membrane integrity tests", J. Membr. Sci., 237, 203 (2004).   DOI
10 O. Ferrer, R. Casas, C. Galvan, F. Lucena, A. Vega, O. Gibert, J. Jofre, and X. Bernat, "Challenge tests with virus surrogates: an accurate membrane integrity evaluation system?", Desalination and Water Treat., 51, 25 (2013).