• Title/Summary/Keyword: 원소 분리

Search Result 442, Processing Time 0.03 seconds

Study on the Precision Analysis of Lanthanides by Atomic Emission Spectroscopy (I). Separation of Rare Earth Elements Using Ln-EDTA Eluent (원자발광광도법에 의한 란탄족 원소의 정밀분석에 관한 연구 (제 1 보) 희토류-EDTA 용리액에 의한 희토류 원소의 분리 회수)

  • Cha Ki-Won;Oh Jin-Hee;Ha Young-Gu;Kim Ha-Suck
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.692-696
    • /
    • 1992
  • $NH_4^+ form cation exchange resin was used to separate one rare earth element from the rare earth mixture solution using Ln-EDTA eluent. Rare earth mixture solution was passed through the resin bed and eluted with 0.1M La-EDTA solution as an eluent. In here all the rare earth element except lanthanum ion are eluted and lanthanum ion absorbed in resin bed is eluted using 0.1M EDTA solution. If Ce-EDTA solution instead of La-EDTA solution was used as an eluent, all the rare earth element except cerium ion are eluted and cerium ion is eluted with 0.1M EDTA solution. This method can be applied to separate the individual rare earth element from the mixture. The separation mechanism is as follows: Absorption : 3RNH_4 + Ln^{3+} = R_3Ln + 3NH_4^+, La-EDTA elution : R_3Ln + La-Y- = R_3La + Ln-Y-, EDTA elution : R_3La + HY^3- = La_-Y + RH + 2R^-.$

  • PDF

레이저를 이용한 동위원소분리

  • Kim, Ung
    • 전기의세계
    • /
    • v.37 no.12
    • /
    • pp.22-28
    • /
    • 1988
  • 우리나라에서 전체 발전량에 대한 원자력 발전량이 차지하는 비율이 현재 30퍼센트를 넘어서고 있고 계속 늘어날 전망이다. 이러한 산업경제의 선진화와 자립화를 추구하고 있는 현 시점에서 핵연료에 대한 기술확보 및 국산화는 머지 않아 대두될 국가적인 과제가 아닐 수 없다. 현재 핵연료의 농축 및 공급은 몇몇 강대국에 의하여 독점적으로 이루어지고 있다. 그러나 기존하는 기체확산법이나 원심분리방법에 비하여 시설투자, 운영비 그리고 생산단가면에서 월등히 우수하다고 평가되고 있는 레이저 동위원소분리법이 대두됨에 따라 선진대열에 있는 많은 나라들이 핵연료의 자체확보를 위하여 이 분야에 대한 연구개발을 서두르고 있는 것이다. 우리나라에서는 이 분야에 대한 연구와 관심이 아직도 미진한 상태에 있으나 앞으로 이 분야에 대한 관심이 높아질 것으로 기대되고 있어 레이저를 이용한 동위원소분리방법에 대한 기초적인 원리를 소개하고자 한다.

  • PDF

The Effect of Eluent Concentration on the Separation of Nd with Ln-resin Method (란탄 레진법에서 용리액의 농도가 Nd 분리에 미치는 영향)

  • Lee, Hyo-Min;Lee, Seung-Gu;Tanaka, Tsuyoshi
    • The Journal of the Petrological Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.365-371
    • /
    • 2015
  • The rare earth element(REE)s play an important role in understanding of rock formation and evolution because of their similar geochemical behaviors. Sm and Nd are more useful than other REEs because Sm-Nd isotopic system has important applications for geochemical interpretation like age dating and crustal evolution. These studies require a chromatographic technique for Sm and Nd separation from the geological samples. Ln-resin method using 0.25 M HCl as the eluent is widely used for Nd separation. However, this technique has a disadvantage of the poor elemental selectivity that the Nd fraction contains Ce as a tailing of the previous fraction. This technical report is a comparison study on the effect of eluent concentration between 0.25 M HCl and 0.15 M HCl on the separation of Nd with Ln-resin method for improving the technique of Nd separation. The results showed that the separation of Ce and Nd using 0.15M HCl as the eluent was not effective compared to the separation using 0.25 M HCl. In this experiment, we could confirm that the dilution of eluent might not be effective on the high purity separation of Nd with Ln-resin method.

Study on the Elution Behaviors of Rare Earth Elements by Iminodiacetic acid (Iminodiacetic Acid 에 의한 희토류원소 용리현상에 관한 연구)

  • Ki Won Cha;Jong Hae Lee
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.183-190
    • /
    • 1985
  • The elution behaviors of the rare earths was carried out in the iminodiacetic acid solution of various pH as eluent using ion exchange resin. The optimum eluent for the quantitative separation of $Eu^{3+},\;Pr^{3+},\;Ce^{3+}\;and\;La^{3+}$ were 0.0301M IMDA solution of pH 8.00 and 9.00 at 5cm column of the resin Dowex 50${\times}$8 (100-200 mesh). The elution order of the rare earth elements was in order of the atomic number of those elements. From the elution behavior of rare earth and u.v spectrum we found that the complexed rare earth species with IMDA changed according to pH of IMDA.

  • PDF

Determination of Individual Lanthanide Elements by Neutron Activation Using a New Comparator Technique

  • Lee, Chul;Yim, Yung-Chang;Chung, Koo-Soon
    • Nuclear Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.83-89
    • /
    • 1972
  • The contents of the individual lanthanide elements are determined by neutron activation using a new comparator technique, which employs the short-lived radio-isotope of 56Mn as a neutron flux monitor. The total rare earths are separated as a group from the monazite sample before irradiation. After irradiation the rare earths are separated from each other by gradient elution with ammonium alpha-hydroxyisobutyrate using a cation-exchange column. The contents of 14 individual rare earths, from lutetium to lanthanum, are deter-mined.

  • PDF

Separation of Lithium Isotopes by Porous Sulfonated Styrene-Divinylbenzene Copolymer Ionexchanger (Porous Sulfonated Styrene-Divinylbenzene Copolymer Ionexchanger 에 의한 리튬 동위원소의 분리)

  • Dong Won Kim;Ki Suck Maeng;Hae Young Song;Hae Il Ryu
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.3
    • /
    • pp.189-193
    • /
    • 1983
  • The lithium isotopes separation experiments were carried out in hydrochloric acid with cation exchanger systerns. In these experiments were employed porous sulfonated styrene-divinylbenzene copolymer and Dowex 50w-x8 as cation exchanger. The contents of lithium of the fraction were determined with atomic absorption spectrophotometer. The relative mass of lithium isotopes of the fractions was analyzed on a mass spectrometer. The isotope separation factors of lithium were calculated from the isotope compositions of these eluted fractions. Separation factor for the system in hydrochloric acid and porous sulfonated styrene-divinylbenzene copolymer was found to be 1.0020, and for the case of system in hydrochloric acid and Dowex 50w-x8 was 1.0011${\om}$0.0002. From these results, we found that the separation factor for porous sulfonated styrene-divinylbenzene copolymer ionexchanger is larger than value of Dowex 50w-x8 ionexchanger.

  • PDF

Separation and Recovery of Rare Earths by Ion Exchange Chromatography (이온교환 크로마토그래피에 의한 희토류 원소의 분리와 회수)

  • Cha, Ki Won;Park, Kwang Won;Hong, Sung Wook
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.11
    • /
    • pp.612-638
    • /
    • 1997
  • The methods of separation and recovery of rare earth elements in monazite sand have been studied by the ion exchange chromatography. Both of cation and anion exchange resin were used as ion exchange resins and the solutions of EDTA, DTPA, IMDA and Ln-EDTA were used as eluents. The H+, Zn2+, Fe3+, Al3+, Cu2+, and NH4+ forms of cation exchange resin were used as retaining ions. Ln-EDTA solution was loaded on the EDTA form of anion exchange resin and separated. The Ln-EDTA solution was also used as an eluent for a selective separation of one element from the rare earth mixture solution. The size effects of resin column, the elution mechanism for the various elution types and the separation of a large amount of rare earths were studied.

  • PDF

A study on the separation and determination of the rare earth Elements by the AG® 50W-X8 cation exchange resin (AG® 50W-X8 양이온교환수지를 이용한 희토류원소의 분리와 분석에 관한 연구)

  • Lee, Jung Sook;Choi, Beom Suk
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.272-278
    • /
    • 2008
  • Methods to separate 14 rare earth elements (REEs) and yttrium by the $AG^{(R)}$ 50W-X8 cation exchange resin, and to determine REEs by inductively coupled plasma atomic emission spectrophotometry (ICP-AES) were described. Ion exchange capacities of REEs on the resin were so high that the REEs were quantitatively ion exchanged under the flow rate of 0.3~1.0 mL/min at pH 1~6. The breakthrough capacity curve of the REEs showed that ion exchange capacities of light REEs (Cerium group) were greater than that of the heavy REEs (Yttrium group). When $200{\mu}g$ of each REEs was ion exchanged on 100 mg of resin, most of the heavy REEs were quantitatively desorbed with 10 mL of 2.0 M of $HNO_3$, while most of the light REEs with 30 mL. The method was applied to the monazite sample. The REEs could be separated from matrix, since ion exchange capacities of matrix ions of Ca, Ti, Mg, Mn were much lower than that of the REEs. However the relative standard deviations of the analytical results by the present method were not improved, as high as 1~5%.

Optimal Conditions for Pretreated Sample for Sr Isotope Analysis by MC-ICP-MS: A Comparison Between Eichrom (SR-R50-S)'s and Bio-Rad(AG®50W-X8)'s Resins (다검출기 유도결합 플라즈마 질량분석기에 의한 Sr 동위원소 분석을 위해 전처리된 시료의 최적 조건: Eichrom사 Sr 수지(SR-R50-S)와 Bio-Rad사 수지(AG®50W-X8) 비교)

  • Myoung Jung, Kim;Seung-Gu, Lee
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.4
    • /
    • pp.507-520
    • /
    • 2022
  • The Sr isotope ratio, which is used as basic data for rock formation time, crustal and mantle evolution studies, is determined by mass spectrometer such as thermal ionization mass spectrometry (TIMS) or multi-detector inductively coupled plasma mass spectrometry (MC-ICP-MS). In this technical report, we compared how incomplete chemical separation of elements affects the determination of Sr isotope ratios. For the experiment, commercial resin, NBS987(NIST SRM987) Sr isotope standard, and rock standard samples from the Geological Survey of Japan (GSJ) such as JG1a, JB3 and JA1 were used. As a result of the comparative experiment, it was clearly observed that the measured values of 87Sr/86Sr change when Rb remains due to incomplete separation of the NBS987 Sr isotope standard sample as well as the rock standard samples of GSJ. This indicates that complete separation is an important factor since the calculated value deviates from the true value even though correction for isotope interference by isobar is performed when measuring the isotope ratio with MC-ICP-MS. This also suggests that, when reporting the measurement result of Sr isotope ratio using MC-ICP-MS, the measurement strength of 85Rb should be reported together with the measurement strength of all isotopes of Sr so that isotope interference by isobar can be judged.

Lead isotope measurement of geological reference materials using thermal ionization mass spectrometry (열이온화질량분석기를 이용한 암석표준시료에 대한 납 동위원소 분석)

  • Lee, Hyo Min;Jo, Hui Je;Kim, Taehoon
    • Analytical Science and Technology
    • /
    • v.33 no.6
    • /
    • pp.245-251
    • /
    • 2020
  • Lead (Pb) has been shown to be a useful tracer of contamination sources and geochemical processes such as age dating and crustal evolution. These studies require a chromatographic technique for Pb separation from geological samples. This paper presents a comparison study on the effect of eluent concentration between 6M HCl and 8M HCl on the separation of Pb from Pb resin. The results showed that the separation of Pb using 6M HCl as the eluent was not effective compared to the separation using 8M HCl. To verify this method, we measured the Pb isotopic compositions of the Pb isotopic standard (NIST NBS981) and geological reference materials (BCR-2, GSP-2, and JG-1a) using a thermal ionization mass spectrometer (TIMS). The results correspond well with the reported values within the error range, implying that this method can be useful.