Selective Separation of $^{59/63}Ni$ from Radioactive Wastes (방사성 폐기물 내 $^{59/63}Ni$의 선택적 분리)

  • Lee Chang-Heon;Jung Kie-Chul;Choi Kwang-Soon;Jee Kwang-Yong;Kim Won-Ho
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.121-128
    • /
    • 2005
  • A study on the selective separation of $^{99}Tc,\;^{94}Nb,\;^{55}Fe,\;^{90}Sr$ and $^{59}Ni(^{63}Ni)$ from various radioactive wastes discharged from the nuclear power plants in Korea is being performed for use in their quantifications which are indispensible for the evaluation of the radionuclide inventory. Separation behaviour of Ce, Ca, Mg, Al, Cr, Ti, Mn and Cu recovered along with Ni during the separation of Re (as a surrogate of $^{99}Tc$), Nb, Fe and Sr by anion exchange and Sr-Spec extraction chromatography was investigated by cation exchange and Ni-Spec extraction chromatography using synthetic radioactive waste dissolved solutions containing matrix elements such as Re, Nb, Fe, Sr, Ni, B, Na, K, Ce, Co, Ca, Mg, Al, Zn, Cr, Pb, Cd, Mo, Mn, Cu, Zr, Ti and U. To purify the Ni fraction recovered and prepare a radionuclide source available for gas proportional counting, an application of the Ni precipitation procedure with dimethylglyoxime in the medium of ammonium citrate and tartaric acid solutions as a masking agent for co-existing metal ions was described in detail.

  • PDF

Fluorescence Signal Analysis of Mixed Rare Earth Elements by Nonlinear Fitting Method (비선형 Fitting법에 의한 희토류 혼합물의 형광신호 분석)

  • Kim, Dukhyeon;Shin, Jangsoo;Song, Kyuseok;Cha, Hyungki;Lee, Jongmin
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.41-45
    • /
    • 1995
  • To analyze mixed rare earth elements quantitatively a nonlinear fitting method was applied to laser induced fluorescence signals. Mixed flourescence signal of two elements, Sm and Eu were resolved independently and determined the concentration of these two elements simultaneously. It was found that detection limit for each element in the mixture was sub-ppb level which was the same as that of the single element sample. Additionally it was found that lifetimes of Sm and Eu extracted from the nonlinear fitting method is the same as in the single element cases.

  • PDF

Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets - (체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 -)

  • Lee, Sung-Ho;Sun, Kyung;Choi, Jai-Geol;Son, Ho-Sung;Jung, Jae-Seung;Ahn, Sang-Soo;Oh, Hye-Jung;Lee, Whan-Sung;Lee, Hye-Won;Kim, Kwang-Taik;Jeong, Yoon-Seop;Kim, Young-Ha;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Background: Blood-foreign interaction cause activation of coagulation and inflammatory process that may lead to multiorgan dysfunction and determine the surgical outcomes. Of the methods for assessing the biocompatibility, the platelet adhesion study is considered as the most valuable evaluation step in blood-foreign interaction. As the most studies have used in-vitro or ex-vivo conditions, we have developed a technique of quantification for platelet adhesion on the blood contact surface by using in-vivo injection of radioactive platelets. Material and Method: A coupled bypass circuit was designed to connect the proximal and descending thoracic aorta in 6 piglets(20∼25 Kg). One side of the circuit tube was consisted of a heparin coated PVC tube(10mm in ID, n=6, Experimental group), and the other, a non-heparin coated PVC tube(10mm in ID, n=6, Control group). After cannulation, the blood was circulated through the circuit for 2 hours. Platelet concentrate was prepared from homologous pig blood 24 hours before the experiment. The platelet concentrate was incubated with Tc-99m-HMPAO for 30 min and then centrifuged for 10 min. The supernatant was discarded and the radio-labeling efficacy was measured. The radio-labeled platelet concentrate was mixed with the autologous plasma to make the volume 5 ml, and the mixture was injected intravenously into the experimental animal. After 2 hour circulation, 5 pieces of the specimen(10mm in length each) were obtained from each PVC tube. The radioisotopes were counted with a gamma counter(Cobra ll, Packard, USA), and the ratio of radioisotope count was compared between the control and experimental group. Result: The radioisotope count number was 537.3221.1 Ci/min in the control group and 311.1 184.5 Ci/min in the experimental group(p=0.0104). The ratio between the groups was 1 to 0.58 (p=0.004). Conclusion: In vivo quantification using technetium-99m-HMPAO labeled platelets is simple and reproducible in evaluating platelet adhesion on a foreign surface. We suggest this technique to be a useful tool for blood compatibility test.

Trace Element Compositions and Optically Stimulated Luminescence Characteristics of Sedimentary Quartz (퇴적물 내 석영의 광여기 루미네선스 특성과 미량원소 조성)

  • Jeon, Gi-Young;Choi, Jeong-Heon;Kil, Young-Woo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.357-365
    • /
    • 2010
  • Optically stimulated luminescence (OSL) of quartz is commonly applied to the age dating of Quaternary sediments. However, one of the issues is that some of the quartz samples are not suitable to OSL dating. Mineralogical analysis of the quartz samples with diverse OSL signals are required to strengthen the reliability and applicability of the OSL dating. We analysed the OSL signal characteristics of sedimentary quartz samples from diverse geological environments and measured their trace element contents using laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Quartz samples could be grouped into ones suitable to OSL dating and ones unsuitable on the basis of their OSL signal characteristics. The average trace element contents ranged from 73 to 260 ppm (Al), and from 61 to 248 ppm (Ti) with minor Li, Mg, Cr, Mn, and Fe contents below 40 ppm. We did not find any significant variation of trace element contents of quartz samples consistent with their OSL signal characteristics. This indicates unknown mineralogical factors causing diverse OSL characteristics which should be confirmed by further analysis of sufficient set of samples.

장수명핵종군 분리공정 평가

  • 이일희;김광욱;홍두성;양한범;임재관;권선길;김영환;정동용;김응호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.521-526
    • /
    • 1998
  • 군분리공정의 관심대상 핵종인 잔존 U, MA인 Am, Np 및 백금족원소의 장수명핵종인 Tc을 방사성모의용액으로부터 효과적으로 분리할 수 있었다. 각 단위공정에 주입되는 용액의 농도를 기준으로 하여 볼 때 잔존 U 제거 공정에서 U, Np, 및 Tc의 회수율은 각각 99.1%. 31.9%, 및 99.5%였다. 개미산 탈질 공정에서는 탈질 용액의 총 산도를 0.4M 이하까지 감소시켰으며, 부수적으로 후속용매추출 공정 전반에 걸쳐 문제 핵종으로 작용하는 Zr, Mo, Fe 등을 각각 99.8%, 94.2%, 22.4% 침전 제거시킬 수 있었다. 마지막으로 DEHPA에 의한 AM/RE 상호분리 공정에서는 연속적인 선택적역추출에 의해 Am 및 Np 의 회수율은 각각 99.8% 및 98.2% 정도였고, Am의 경우 7.6%읜 Fe및 81.6% 의 Mo가, Np의 경우 5.8%의 Fe이 불순물로서 여전히 존재하고 있다. 한편 RE 생성물에서는 97~99.9%의 RE가 회수 제거되었다.

  • PDF

AQUA 219 -중금속 함유 폐수 및 일반종합폐수 처리제

  • 한국환경기술인연합회
    • Environmental engineer
    • /
    • s.123
    • /
    • pp.42-43
    • /
    • 1996
  • 중금속을 함유하는 폐수는 일반적으로 단일성분의 원소로 되어 있지 않고 여러 종류의 금속성분이나 유기물이 혼합된 상태로 발생되기 때문에 화학적인 중화나 분해로서 처리하기 곤란하므로 흡착성이 풍부한 광물질의 무기화학성분을 추출하여 흡착, 침전, 분리하는 방법을 이용할 수 있다. Aqua # 219는 폐수 처리용 약품으로 현재 사용하고 있는 설비를 일부 개조하거나 또는 기존설비를 그대로 사용하여 저렴한 가격으로 처리할 수 있는 중금속 흡착제이다.