• Title/Summary/Keyword: 원격검침시스템

Search Result 170, Processing Time 0.031 seconds

Remote Measurement System with PCS and One Chip Microcontroller (PCS와 원칩 마이크로콘트롤러를 이용한 원격 검침 시스템)

  • 이지홍;하인수;김인식
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.171-174
    • /
    • 2000
  • In stead of RF module which has been used conventionally in many remote measurement applications, a new type of remote measurement system based on PCS(Personal communication system) and one chip Microcontroller is proposed in this work. PCS has many advantages with respect to cost reliability, communication quality, and so on. The proposed system consists of three different modules: PCS module, micro-controller module, and sensor module. System configuration as well as illustrative experiments will be described in detail.

  • PDF

Energy Management System based on Advanced Metering Infrastructure (AMI기반 에너지 관리시스템)

  • Ju, Seong-Ho;Lim, Yong-Hoon;Baek, Jong-Mock
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.109-110
    • /
    • 2010
  • 스마트그리드의 주요 분야 중 하나인 AMI(Advanced Metering Infrastructure)는 상위 서버에서 고객 단말까지 양방향 통신인프라를 기반으로 다양한 부가서비스를 제공하기 위한 차세대 원격검침 인프라이다. 이는 댁내 다양한 전력기기와 연계되어 여러가지 에너지정보를 고객에게 제공함으로써 에너지소비효율을 높일 뿐만 아니라 최근 경제적 가치를 평가받고 있는 탄소배출량 감소 효과를 볼 수 있다. 본 논문에서는 이러한 AMI기반 에너지관리 요소장비를 설계, 개발하여 운영하는 방법을 제안하고자 한다.

  • PDF

AMI Network Failure Analysis based on Graph Database (그래프 데이터베이스 기반 AMI 네트워크 장애 분석)

  • Jeong, Woo-Cheol;Jun, Moon-Seog;Choi, Do-Hyeon
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.7
    • /
    • pp.41-48
    • /
    • 2020
  • Recently, the spreading business of AMI (Advanced Metering Infrastructure) remote metering systems in various regions of the country has been activated, and it provides various metering functions such as two-way communication and security plan functions for power demand management. Current AMI system is difficult to analyze based on the existing RDB(Relational Database) due to the increase in the size of new internal IoT devices and networks. This study proposes a new GDB(Graph Database) based failure analysis method that utilizes existing RDB data. It analyzes the correlation of new failure patterns through accumulated data such as internal thresholds and status values. As a result of GDB-based simulation, it was confirmed that RDB can predict to a new obstacle pattern that was difficult to analyze.

A Study on account and authority management method of IOT system (IOT 체계의 계정 및 권한관리 방법에 대한 연구)

  • Kim, Min-Hwi;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.225-228
    • /
    • 2017
  • In this paper, we propose a methodology to deal with the IOT system gradually as the use of effective systems such as electronic devices, healthcare, smart cars, smart home, remote meter reading and telemedicine closely related to our real life in the IOT system An IOT integrated account solution is needed as a way to address these needs as the demand grows for the need to identify and manage how users access and use the system for what period of time and at what point in time. We propose the communication algorithms for endpoint system, IOT system management rights policy, user information, and how to apply them to IOT system smart car and smart home on each object internet.

  • PDF

A Signal Anti-reduction System in PLC using Ferrite Core and Switching Amplifier (페라이트 코어와 스위칭 증폭기를 이용한 PLC 신호 감쇠 저하 시스템)

  • 고종선;김영일;김규겸
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.474-480
    • /
    • 2001
  • In this paper a low signal reduction communication system that does not use the communication line but power line is presented It will be very useful for an information-oriented society with tele-metering and home automation. The conventional system has a difficulty in transmitting information due to decreasing communication voltage. The proposed system employs a special type switching amplifier system which has a low inner resistance and uses high efficient ferrite core in coupling circuit. This new system is proposed to reduce the loss of conductor load and coupling circuit in a PLC system.

  • PDF

Design and Test of Communication Between Data Concentrator Units for Efficient AMI(Advanced Metering Infrastructure) System (효율적 원격검침시스템 구축을 위한 집중장치간 연계통신 방법 설계 및 성능 테스트)

  • Im, Eun-Hye;Park, Byung-Seok;Kim, Young-Hyun;Choi, In-Ji;Myoung, No-Gil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2337-2343
    • /
    • 2010
  • AMR(Automatic Meter Reading)/AMI(Advanced Metering Infrastructure) is actively deployed all over the world. efficient, economical, stable and reliable system need to push forward the AMR/AMI business, so various researchs are in progress. In electric power system of domestic, a transformer is connected average twenty to thirty households and PLC is possible to communication within household connected same transformer. So if server and data concentrator unit(DCU) share circuit line through communication between transformers, communication network is able to efficient. Therefore we design new communication method between DCUs and test it and demonstrate the performance.

The study of BPLC security technology trend (광대역 전력선통신 기반 보안기술 동향)

  • Baek, Jongmock;Ju, Seongho;Kim, Chunghyo
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.392-393
    • /
    • 2011
  • 본 논문에서는 원격검침시스템의 기반기술이 되는 광대역 전력선 통신인프라에 필요한 보안요구사항을 도출하고 국내외 표준에 반영된 보안기술을 연구하였다. 전력선 통신망에서 자원의 가용성을 확보하기위해 사용자 및 기기의 인증기능과 접근 제어기능을 검토하였으며 전력선통신 표준에 반영된 보안기술은 제각기 다른 방향으로 접근하는 것을 알수있었다. 특히 한국표준에 기술된 보안은 셀단위의 동일한 키를 사용하고 칩?의 하위계층에서 58비트 DES알고리즘만으로 보안대책이 미흡하고 다른 보안솔루션이 적용이 필요한 것으로 사료 된다.

  • PDF

A Study on the Power Loss Monitoring Methods with AMI systems (지능형 원격검침시스템을 이용한 전력손실 감시방법에 대한 연구)

  • Myoung, No-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.67-74
    • /
    • 2013
  • Major utilities have been focusing on R&D and nationwide business of AMI system which plays a vital role in SmartGrid whose concept is to maximize energy efficiency and optimize electric power facility management with exchanging real time information between utilities and consumers based on ICT technologies in power grid. In this paper, we suggest a power loss monitoring method using KEPCO's AMI system which is operating in fields and with the acquisition of AMI data and analyses verify the validation of a power loss monitoring method.

Efficient Authentication and Management System for PLC-based AMR (전력선통신기반 원격검침시스템을 위한 효율적인 기기인증 및 관리체계)

  • Ju, Seong-Ho;Choi, Moon-Seok;Lim, Yong-Hoon;Choi, Jong-Hyup
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.353-354
    • /
    • 2008
  • Security weakness in PLC network can be made up for by authentication and management scheme of PLC modules introduced in this paper. Each PLC module must pass the authentication procedure to work normally in PLC network as soon as being installed in the spot. Based on this scheme, all PLC devices are registered, certified, and managed automatically in central control center - AMR server, authentication server, NMS server, and DB server.

  • PDF

A Study on Development and Operation of Power Energy Consumption Consulting System (전력에너지 컨설팅 시스템 개발 및 운영방안 연구)

  • Kim, Sun-Ic;Yu, In-Hyeob;Ko, Jong-Min;Jung, Nam-Jun;Cho, Sun-Gu
    • Annual Conference of KIPS
    • /
    • 2007.05a
    • /
    • pp.544-546
    • /
    • 2007
  • 본 연구에서는 전력부가서비스 시스템으로 개발한 전력에너지 컨설팅 시스템의 주요 기능과 운영방을 소개한다. 본 시스템의 주요 기능은 전력소비 데이터 분석, 전력사용량 분석, 전력요금 분석, 전력요금 컨설팅 보고서 제공 등 4가지로 구분할 수 있다. 원격검침을 시행중인 고압고객 중 계약전력이 100kW 이상인 대수용가로부터 특히, 전력요금 절감을 필요로 하지만 별도의 설비나 인력을 보유하지 않은 10,000kW 이하 고객을 적용대상으로 하고 있다. 본 시스템은 수용가에게는 전력요금 절감을 전력회사 및 Energy Service Provider에게는 간접적 부하/수요관리 효과를 목표로 개발하였으며, 향후 대수용가를 대상으로 전력부가서비스 적용 사업화 분야에 활용될 수 있을 것이다.