• Title/Summary/Keyword: 원거리 AC/A

Search Result 18, Processing Time 0.023 seconds

The Study of Distance and Near AC/A Ratio by Stimulus (조절자극 방식에 따른 원거리와 근거리 AC/A비에 관한 연구)

  • Jo, Tae-Sik;Kim, In-Suk;Jang, Jung-Un
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.417-423
    • /
    • 2011
  • Purpose: This study was to investigate that near gradient AC/A ratio could be used to prescribe a patient with distance exophoria, we compared the difference between distance gradient AC/A ratio and near gradient AC/A ratio. Also, this thesis was to understand the relationship between calculated AC/A ratio and gradient AC/A ratio. Methods: Objective and subjective refractive error were corrected and we used Howell (3 m) chart for distance phoria tests and Howell-Kim (40 cm) chart for near phoria tests. The near gradient AC/A ratio and calculated AC/A ratio were used by Howell-Kim (40 cm) combined with +1.00 D, -1.00 D, +2.00 D and -2.00 D. Results: The average value of distance exophoria was 1.17${\pm}$1.17 $\Delta$, and the average value of near exophoria was 3.71${\pm}$2.80 $\Delta$ (t-test. p<0.001). The correlation of distance phoria with near phoria was little higher (r = 0.59, p < 0.001). Gradient AC/A ratios depending on measuring distance and stimulus were higher (r = 0.11~0.53. P < 0.001), when distance was shorter and stimulus to accommodation was more. Also, stimulus to accommodation by plus lens was higher than stimulus to accommodation by minus lens (paired t-test. p < 0.001). There was negative correlation between calculated AC/A ratio and gradient AC/A ratio. As the calculated AC/A ratio was higher, gradient AC/A ratio was lesser. Near gradient AC/A ratio was slightly higher than distance gradient AC/A ratio. Distance and near gradient AC/A ratio taken through the subjective -1.00 D were 1.30 $\Delta$/D and 1.68 $\Delta$/D(t-test. t=1.67, p < 0.001). Conclusions: There is negative correlation between calculated AC/A ratio and gradient AC/A ratio. Also, there is subtle difference between near gradient AC/A ratio and distance gradient AC/A ratio. Therefore, we need to measure distance gradient AC/A ratio when a practitioner prescribe glasses for a patient with distance exophoria.

Study on the Influence of LASIK on Binocular Change (양안시 변화에 대한 라식수술의 영향에 관한 연구)

  • Lee, Ki-Seok;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.267-273
    • /
    • 2006
  • For this study, we measured heterophoria, Calculated AC/A, Gradient AC/A of pre & post LASIK operation. In case of heterophoria, the results showed that orthophoria 2.78% decreased, exophoria 2.78% increased on pre & post op distance phoria and exophoria 5.55% increased, esophoria 5.55% decreased on pre & post op near phoria. In case of AC/A, Calculated AC/A significantly decreased as 0.36 at AC/A and accommodation decreased as 1.25D (p<0.05). It showed that Gradient AC/A decreased 0.34 and PC/A increased 0.09 but they didn't show significant difference.

  • PDF

The Analysis of Binocular Vision Function by measuring Accommodative Convergence(AC/A) (조절성 폭주비(AC/A) 측정에 의한 양안시 기능 분석)

  • Kang, In-San;Seo, Yong-Won;Choi, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.159-164
    • /
    • 2005
  • Accommodation and convergence is combination movement which is closely connected with each other. When one of them is stimulated, both of functions occur at the same time. Specially, the convergence by the accommodation's stimulation is called as accommodative convergence. That has excess or deficiency according to refraction state of eye. This study was performed by using both of Gradient method and Heterophoria method to 41 adults who have no any ophthalmic disease. 1. As the result of investigation about the distribution of heterophoria at distance, there were orthophoria of 5 subjects, exophoria of 32 and esophoria of 4. Exoporia occupied at the hightest rate. The distribution of heterophoria at near cover a wider range more than at distance. 2. When we measured the horizontal heterophoria amount in the state of relaxation of accommodation power of lens, exophoria amount increased in case of 38 subjects. 3. The person who has $4{\sim}6{\Delta}/D$ which conform to normal AC/A ratio occupied 27 subjects(66%) in Heterophoria method and 16(39%) in Gradient method, respectively.

  • PDF

Expected Values for the Analysis of Accommodation and Vergence Dysfunction of Young Adluts (젊은 성인의 조절 및 이향운동 기능장애 분석을 위한 표준 값)

  • Baarg, Saang-Bai
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.127-134
    • /
    • 2008
  • Purpose: The purpose of this study was to determine the expected values of accommodation and vergence system for analysis of binocular vision. Methods: Seventy three healty subjects without past history of eye disease were selected for this study, Patients showing clinical binocular anomalies including manifest squint and intermittent heterotropia were excluded and data was collected on 54 patients(mean age, 25.3${\pm}$2.7 year). Near point of convergence, distance and near phoiras were measured based on objective deviation angle. And then AC/ A ratio, relative accommodation were measured and all of the data were compared with the Morgan's expected values. Results: The values of distance and near heterophoria were 1.24${\pm}$2.72${\Delta}$ and 2.70${\pm}$4.91${\Delta}$ respectively and the gradient AC/A ratio was 3.92${\pm}$2.17${\Delta}$/D which were all about the same compared with the Morgan's expected values. The values of distance negative fusional convergence was same, however, distance positive fusional convergence was 7${\Delta}$ greater than the Morgan's one. There were no significant differences in the range values of both near vergences while the range of distance vergence was relatively larger than the Morgan's one. Positive relative accommodation was +0.37D greater and negative relative accommodation was -0.63D greater than the Morgan's values. Conclusions: The findings in this study appear that the Morgan's expected values have a possibilities of including considerable proximal convergence value. In comparison with Morgan's values, Korean's normal expected values have much different values of especially BO limit, so if the Morgan's values are directly applied to binocular vision analysis for Korean people, it may lead to an inaccurate binocular vision diagnosis. This results can be used to diagnose the accommodation and vergence system of Korean normal young adults.

  • PDF

A Study on The Measurement and Tendency of Horizontal Heterophoria Using Von Graefe Method (Von graefe법을 이용한 사위의 측정과 경향에 관한 연구)

  • Lee, Ki-Seok;Jung, Mi-Boon;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.151-157
    • /
    • 2006
  • We researched distant & near horizontal heterophoria of myope using von graefe method on full correction condition for young people 49 subjects(98eyes) with myopia after testing the objective refraction. Among the whole subjects, we got the results as Orthophoria 51.00%, Exophoria 38.75%, Esophoria 10.25% and Heterophoria 49.00% at a long distant. At a short distant, they showed Orthophoria 22.45%, Exophoria 67.35, Esophoria 10.20%, and Heterophoria 77.55%, Orthophoria 22.45. At a long distant they showed Orthophoria 4.08%, Exophoria 8.16%, Esophoria 0% on high myopia, Orthophoria 18.37%, Exophoria 12.25%, Esophoria 0% on middle myopia and Orthophoria 28.57%, Exophoria 18.37%, Esophoria 10.20% on low myopia.

  • PDF

The Change in Far Distance and Near Distance of Exophoria Patients (외사위 환자의 원거리와 근거리 때의 변화)

  • Seong, Jeong-Sub;Hong, Soo-Hak
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.143-147
    • /
    • 2002
  • A36 patients of a total of 60 persons show $2{\Delta}$ and less, and the rest of 24 patients show $6{\Delta}$ and less. The patient, who increase more in near distance than far distance in exophoria amount are 27 persons. The unchanging patients are 13 persons, and the patients who phoria amount decreasing are 20 persons. Like this, the patients who phoria amount unchange and decrease show more than the half. That is why convergence increases in near distance. The expected value of horizontal phoria in near distance is $3exo{\pm}3$. Only 13 patients get rid of its value, 47 satisfy its value. In AC/A value, 35 persons show under 3(1ow), 21 persons show 3~5(normal), and 4 persons show more than 5(high). By Percival's theory, 36 patients don't feel a slight asthenopia without correcting phoria. Finally, in near point of convergence 27 patients show 10cm and less, 24 patients show 11~15cm, 3 patients show 15~20cm, and 6 patients show 21~25cm. Most of them show high accommodation.

  • PDF

Change of Binocular Vision Induced by Longitudinal Chromatic Aberration during Near Work (근거리 작업 시 종색수차에 따른 양안시의 변화)

  • Kim, Se-il;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.219-228
    • /
    • 2015
  • Purpose: The current study was performed to compare the difference in binocular visual function depending on variable background colors at near work. Method: Fifty four adults (18 males, 34 females) who consented to the present study and had no ocular disease, ocular surgery history, strabismus and amblyopia with normal binocular vision were participated into this study. The subjects were asked to read the novels with black letter printed on white, red, green and blue background for 15 min. Then, their heterophoria, AC/A ratio, near point of convergence, accommodation facility, relative accommodation and vergence were measured before and after reading. The difference of measurements were compared. Result: Overall heterophoria was tended to decrease with regardless of background color. AC/A ratio showed a tendency of increase after reading the novels with all backgrounds except white background. Near point of convergence was significantly increased compared to before reading at all background color. Accommodative facility of dominant and non-dominant eyes were also significantly increased after reading however, binocular accommodative facility showed a tendency of decrease. Negative relative accommodation also decreased at all background colors however, the change of positive relative accommodation was not significantly different. In case of vergence, there was significant difference in break point of far BO and recovery point of far BI by the wavelength of background color. Conclusions: From the results, it was known there is convergence change depending on the wavelength of light even though same amount of accommodation and convergence is required when doing near work for certain period. Thus, it can be suggested that the adjustment of the near working environment which perception of various color was required, should be conducted according to the main wavelength.

Changes in Visual Acuity and Values of Objective Refraction with Breath Alcohol Concentration (호흡 알코올 농도에 따른 시력과 타각적 굴절검사 값의 변화)

  • Jung, Su A;Nam, Soo-Kyung;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.187-193
    • /
    • 2015
  • Purpose: This study was aimed to investigate effects of increased breath alcohol concentration (BrAC) which is the standard measurement of alcohol consumption in sobriety test under current laws on visual acuity and values of objective refraction. Methods: For twenty three males in 20s (average age $21.17{\pm}2.19$ years, body mass index (BMI) $22.09{\pm}2.16$) were selected. Distance and near visual test was performed at BrAC of 0%, 0.05% and 0.08%, and objective refraction with open-field auto-refractometer was also performed at different BrAC. Results: As breath alcohol concentration is increased, distance visual acuity was decreased, which was statistically significant, but near visual acuity was not changed. Also, values of objective refraction tended to be increased towards minus as breath alcohol concentration is increased. Conclusions: As breath alcohol concentration is increased, corrected visual acuity is decreased and refractive power is towards minus, it is necessary that visual acuity test and refraction measurement should be conducted under sober condition.

Changes in the Physiology of eye and Ocular function due to alcohol intake (알코올 섭취에 따른 눈의 생리기능과 안기능의 변화)

  • Lee, Jeung-Young;Seo, Jung-Ick;Park, Eun-Kyu
    • Journal of the Korea society of information convergence
    • /
    • v.7 no.2
    • /
    • pp.25-29
    • /
    • 2014
  • In this study, it examined the effects of alcohol on the physiology of the eye and ocular function. It was measured to IOP(intraocular pressure), tear secretion, stereoscopic parallax, AC A ratio, convergence ability, divergence ability alcohol intake before and after. The results were as follows. The mean IOP before alcohol intake 15.14mmHg and the mean IOP after alcohol intake 12.8mmHg. Average decreased 15.44%. The mean tear secretion before alcohol intake 17.125mm and the mean secretion after alcohol intake 9.875mm. Average decreased 42.33%. Stereoscopic parallax has increased by about four times that 40' before alcohol intake to 165' after that. AC/A ratio has increased by 14.6% that $5.40{\Delta}/D$ before alcohol intake to $6.19{\Delta}/D$ after that. Convergence and divergence ability was no significant change in both distance and close range.

  • PDF

Comparison of Binocular Function in Normal Subjects and Convergence Insufficiency (정상안과 폭주부족안의 양안시기능 검사값 비교)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.287-291
    • /
    • 2010
  • Purpose: The aim of this study was to compare binocular functions such as near point of convergence (NPC), AC/A ratios, heterophoria, accommodation, accommodation lag, positive relative accommodation (PRA), negative relative accommodation (NRA), positive relative convergence (PRC), negative relative convergence (NRC) in normal subjects and convergence insufficiency. Methods: 86 subject (male n=45, female n=41, mean $age{\pm}SD=23.27{\pm}2.85$ years) without amblyopia, strabismus, and ocular pathology were studied. Forty three patients each group were classified as normal subjects and convergence insufficiency group based on AC/A ratio and far and near phoria. Binocular function of the two groups was measured using phoropter. r. Results: The values between normal subjects and convergence insufficiency were 5.71 cm and 7.07 cm for NPC, 5.28 and 2.81 for Heterophria AC/A, 0.92 exo/3.36 exo and 2.17 exo/10.84 exo for far and near phoria, 15.49/23.30/13.30 and 13.50/20.02/9.09 for PRC, respectively. However, there were no significant differences between normal subjects and convergence insufficiency for accommodative amplitude, accommodative lag, PRA, NRA, BI vergence test, BO vergence test, NRC. Conclusions: Both groups were a significant difference for cover test, NPC, Heterophria AC/A, far and near phoria, break point of PRC, and recovery point of PRC.