• Title/Summary/Keyword: 원거리측정시스템

Search Result 97, Processing Time 0.026 seconds

Long Distance and High Resolution Three-Dimensional Scanning LIDAR with Coded Laser Pulse Waves (레이저 펄스 부호화를 이용한 원거리 고해상도 3D 스캐닝 라이다)

  • Kim, Gunzung;Park, Yongwan
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.4
    • /
    • pp.133-142
    • /
    • 2016
  • This paper presents the design and simulation of a three-dimensional pixel-by-pixel scanning light detection and ranging (LIDAR) system with a microelectromechanical system (MEMS) scanning mirror and direct sequence optical code division multiple access (DS-OCDMA) techniques. It measures a frame with $848{\times}480$ pixels at a refresh rate of 60 fps. The emitted laser pulse waves of each pixel are coded with DS-OCDMA techniques. The coded laser pulse waves include the pixel's position in the frame, and a checksum. The LIDAR emits the coded laser pulse waves periodically, without idle listening time to receive returning light at the receiver. The MEMS scanning mirror is used to deflect and steer the coded laser pulse waves to a specific target point. When all the pixels in a frame have been processed, the travel time is used by the pixel-by-pixel scanning LIDAR to generate point cloud data as the measured result.

Presbyopic Spectacle and Monovision for Reading Performance Before Adaptation (노안안경과 모노비젼 콘택트렌즈 착용 후 적응 전 읽기 능력 평가)

  • Chu, Byoung Sun;Hwang, Jeong Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.263-268
    • /
    • 2010
  • Purpose: Eye movements and fixation ability are an important procedure to obtain external information and essential means of clear vision. The purpose of this study was to determine the reading performance such as reading time and number of fixations when random text was viewed at varying distances. Methods: Twenty two presbyopes were participated. All subjects were screened for their suitability to participate in the study by clinical examination, and none of the participants had previously worn contact lenses and no previous experience of wearing any types of presbyopic vision correction except single vision. The reading time and number of fixations were recorded using eye tracker while each subjects was waring four vision corrections which included single vision for distance (SV), bifocal spectacle lenses (BIF), progressive addition lenses (PAL), and monovision (MV). The reading material was presented at distance and near distance. Results: Reading time and number of fixations for near stimulus were significantly different among vision correction used in this study (p<0.001). In particular, wearing SV required longer reading time and produced longer fixation duration for near text. However, reading distance text was similarity performed across vision corrections tested and there was no statistical difference found for either reading time and number of fixations. Conclusions: Wearing presbyopic vision correction is advantageous for reading task of near stimuli, but not having near correction such as wearing SV could result in longer reading time and higher number of fixation due to lacks of accommodative ability for near task. For the future studies, it would be interesting to examine the performance of reading both at adapted and unadapted stages as examining only unadapted wearers was limitation of this study.

The Development of the Medical Information's Transmission System Using the Bluetooth (블루투스 통신을 이용한 의료정보 전송 시스템의 개발)

  • Hong, Seung-Beom;Jie, Min-Seok
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.5
    • /
    • pp.787-792
    • /
    • 2009
  • A number of very promising applications such as health monitoring and U-Health of ubiquitous techniques has attracted interest in recent years. Because it can observes the condition of patient from long distance using the equipment which combines with radio communication and medical monitoring system. If it is at emergency situation, it can disposes the condition of the patient. In this paper, we propose the new data format and the transmission communication system of combination medical information with the bluetooth. And we produce the on-board system which transmits the medical information. This system integrated the blood pressure and glucose monitor of personal medical equipment, and the medical information which obtained from on-board system acquires through the gateway with the bluetooth. Medical information is transmitted to the tele-monitor server by the wireline network. We evaluated the proposed system under the laboratory environment and confirmed the excellent performance of transmission of the medical information.

  • PDF

Real-time Water Supply Facilities Monitoring System based on the USN (USN 기반의 실시간 수도설비 모니터링 시스템)

  • Kim, Yong-Tae;Yoo, Neung-Hwan;Park, Gil-Cheol;Kim, Seok-Soo;Kim, Tai-Hoon;Lee, Sang-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.6
    • /
    • pp.1207-1213
    • /
    • 2007
  • This paper has researched water supply facilities management using real-time water utility monitoring system based on USN(Ubiquitous Sensor Network) which is consisted of wireless sensors transferring waterworks facilities md treatment information about a valve-room and flowmeter-room of water supply installation. In the manholes, it was installed with flowmeter, pressure sensors, vibration sensors, Co-sensors, and hydro-thermograph sensors. These measurement values which are received by PDA are used for facilities operation on the spot safely and conveniently. It has also provided safe installation management via CDMA(Code Division Multiple Access) network which transfers data to remote servers to monitoring at a distance place. With safety management system of water supply facilities on USN technology convenience and safety is increased in real situation, and it is expected that we can supply clean water to people as much safer and more effective water supply installation management.

Ambient CO2 Measurement Using Raman Lidar (라만 라이다를 이용한 대기 중 이산화탄소 혼합비 측정)

  • Kim, Daewon;Lee, Hanlim;Park, Junsung;Choi, Wonei;Yang, Jiwon;Kang, Hyeongwoo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_3
    • /
    • pp.1187-1195
    • /
    • 2019
  • We, for the first time, developed a Raman lidar system which can remotely detect surface CO2 volume mixing ratio (VMR). The Raman lidar system consists of the Nd: YAG laser of wavelength 355 nm with 80 mJ, an optical receiver, and detectors. Indoor CO2 cell measurements show that the accuracy of the Raman lidar system is calculated to be 99.89%. We carried out the field measurement using our Raman lidar at Pukyong National University over a seven-day period in October 2019. The results show good agreement between CO2 VMRs measured by the Raman lidar (CO2 Raman Lidar) and those measured by in situ instruments (CO2 In situ) which located 300 m and 350 m away from the Raman lidar system. The correlation coefficient (R), mean absolute error (MAE), and root mean square error (RMSE) between CO2 In situ and CO2 Raman Lidar are 0.67, 2.78 ppm, and 3.26 ppm, respectively.

A Multibeam Pattern Synthesis of Planar Array Antenna (평면 배열 안테나에 의한 다중 빔 복사 패턴의 합성)

  • Hur, Moon-Man;Lee, In-Jae;Yoon, Hyun-Bo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.10 s.113
    • /
    • pp.1007-1019
    • /
    • 2006
  • In this paper, the synthesis method of multibeam radiation pattern with multi-directional beams and nulls is proposed. Genetic algorithm is applied for the optimization of amplitude and phase of the feeding signal into each element that is structured in planar array of single patch antenna with an arbitrary field distribution. To verify the validity of the proposed method, $2{\times}2$ planar array antenna is used for the measurement and the measured far field radiation pattern is compared with the simulation result. As a result, the synthesis of multibeam radiation pattern is implemented by the optimization of amplitude and phase of the feeding signal into each element of $8{\times}8$ planar array antenna system.

도파로 모드와 결합된 측면연마형 광섬유 SPR 센서

  • An, Jae-Heon;Seong, Tae-Yeon;Kim, Won-Mok;Lee, Gyeong-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.305-305
    • /
    • 2011
  • 표면 플라즈몬 공진(SPR) 현상을 이용한 광섬유 센서는 SPR 센서의 우수한 표면 민감도, 비표지 검출능 등의 특징은 유지하면서 측정시스템이 단순해지고 저렴하게 제작이 가능하며 원거리 검출에 유리하다는 장점으로 많은 연구가 진행되고 있다. 최근 스택 제어가 용이하고 민감도 또한 우수하다는 이유로 측면 연마형 센서 구조를 적용한 연구가 많이 이루어지고 있다. 본 연구에서는 기존 Kretchman형태의 SPR 센서의 분해능 향상을 위해 사용된 광도파로 구조를 측면 연마형 광파이버에 적용시켰다. 금속 층 / 유전체 층 / 금속 층으로 구성되어 있는 광도파로 구조와 Au 단일 층을 사용한 기존 구조에 대한 이론 전사모사를 진행하고 실물 소자를 제작하여 특성을 평가하였다. WCSPR 센서에서는 두 개의 반사율 dips이 나타난다. 하나는 단파장영역에서 나타나는 폭이 작은 형태이며 또 다른 하나는 장파장영역에서 나타나는 폭이 넓은 형태이다. 단파장에서의 dip은 입사각에 크게 영향을 받지 않기 때문에 Wavelength interrogation mode을 이용하는 광섬유 SPR센서에 적용할 경우 분해능이 향상될 것 이다. WCSPR 센서는 도파로의 유전체층에서 진행되는 모드를 이용하면 Self-referencing을 할 수 있다, 또한 유전체 층의 두께를 변화 시켜 중심파장의 위치를 조절할 수 있는 특징을 갖고 있다. 결과적으로 광도파로 구조를 광파이버에 적용시켜 기존 Au 단일 층 구조의 SPR 센서에 비해 좀 더 정확하고 광범위한 감지를 할 수 있다.

  • PDF

Long Distance Identification of Water and Oil using an Ultraviolet Fluorescence Measurement System (원거리의 물과 오일을 구별할 수 있는 UV형광측정시스템 개발과 분석에 대한 연구)

  • Baek, Kyung-hoon;Lee, Joon-seok;Jeon, Su-jeong;Park, Bo-ram;Park, Seong-wook
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.266-270
    • /
    • 2022
  • Owing to the rising volume of seaborne trade, oil spills damage the marine environment for over 250 yearly. Thus, various analysis methods such as the Fourier-transform infrared (FTIR), Raman spectroscope, and gas chromatography are used to monitor oil spills at sea, but these methods are expensive. Recently, to reduce operational costs, an underwater fluorometer was adopted. However, this approach is not ideal for the remote sensing of oil spills because the device gets submerged in the sea. In this study, we have designed and developed a monitoring system that uses ultraviolet fluorescence to detect spilled oil or water from a distance, as well as proposed an analyzing method defining based on water Raman signal and QF535. Each fluorescence spectrum of water, oil (crude oil), and Bunker A was obtained using the system, and was calculated and analyzed from the spectrum individually. Based on the results of the analysis, we could successfully identity water and oil at a long distance.

A Study Absolute Position Estimation of Sound Source (3차원 음향홀로그래픽을 이용한 음원위치 추정에 관한 연구)

  • Kim, Chun-Duk;Sim, Dong-Youn;Jang, Bee;Lee, Chai-Bong;Cha, Kyung-Hwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.76-82
    • /
    • 1997
  • The paper describes simulations and experimental results using a measuring system which utilizes the acoustic holographic method in order to exactly estimate an absolute position of a sound source. The measuring surface is installed to satisfy with a far field to the sound source and is composed of linear arrayed seven microphones. A measurement is simultaneously recorded by a reference microphone setting up a neighbour sound source and the linear arrayed seven microphones which are moved to the same interval. An absolute position of sound source is estimated by the cross-spectrum method to the received sounds between a reference and the measuring microphones. Phase differences of each microphone and time delays during scanning are compensated to the reference microphone and the measuring time of the first column. An optimal interval for each microphone in the measuring surface is decided by a numerical simulation. A source signal makes use of a sinusoid, and S/N ratio is 30dB in the experiment. The optimal microphone's interval in the simulation and the experiment is decided in order to satisfy with the Nyquist space sampling condition related to the wave length of 2kHz sinusoid. Mainlobe width of a estimated 3D hologram in the case of 2kHz source signal is decreased to 87% and 30% in comparison to 500Hz and 1kHz, and then a valid of simulation results is confirmed. Therefore, we verified a utilization of the study for a sound source estimation using 3ㅇ acoustic holographic method.

  • PDF

Non-Foster Matching Circuit for Wideband Anti-Jamming Small GPS Antennas (광대역 항재밍 소형 GPS 안테나용 비 포스터 정합회로)

  • Ha, Sang-Gyu;Jung, Kyung-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.12
    • /
    • pp.1112-1115
    • /
    • 2016
  • Global Positioning System(GPS) is a useful system used in both civilian and military applications. However, the signal of GPS is susceptible to jamming attacks due to low receive sensitivity, since the signals come from the satellite located at over 20,000 km above the earth. In this paper, we have conducted a preceding research on a non-Foster matching circuit that efficiently matches an electrically ultra-small GPS antenna. Electrically Small Antennas(ESAs) are inefficient radiators and are difficult to match in wideband due to extremely high quality factor. In order to match small GPS antenna in wideband, a non-Foster matching circuit for a small GPS antenna was designed. A negative impedance converter circuit consisting of Linvill's cross-coupled pair transistors was fabricated and its stability was verified by the time-domain stability analysis. In addition, anechoic chamber measurements show that the non-Foster matching circuit for small GPS antenna can lead bore-sight gain improvement by more than 17 dB.