• Title/Summary/Keyword: 움직임 프로그램

Search Result 115, Processing Time 0.029 seconds

A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans (이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석)

  • Kim, Tae-Ho;Yoon, Jai-Woong;Kang, Seong-Hee;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 2012
  • In this study, we quantify the residual motion artifact in 4D-CT scan using the dynamic lung phantom which could simulate respiratory target motion and suggest a simple one-dimension theoretical model to explain and characterize the source of motion artifacts in 4DCT scanning. We set-up regular 1D sine motion and adjusted three level of amplitude (10, 20, 30 mm) with fixed period (4s). The 4DCT scans are acquired in helical mode and phase information provided by the belt type respiratory monitoring system. The images were sorted into ten phase bins ranging from 0% to 90%. The reconstructed images were subsequently imported into the Treatment Planning System (CorePLAN, SC&J) for target delineation using a fixed contour window and dimensions of the three targets are measured along the direction of motion. Target dimension of each phase image have same changing trend. The error is minimum at 50% phase in all case (10, 20, 30 mm) and we found that ${\Delta}S$ (target dimension change) of 10, 20 and 30 mm amplitude were 0 (0%), 0.1 (5%), 0.1 (5%) cm respectively compare to the static image of target diameter (2 cm). while the error is maximum at 30% and 80% phase ${\Delta}S$ of 10, 20 and 30 mm amplitude were 0.2 (10%), 0.7 (35%), 0.9 (45%) cm respectively. Based on these result, we try to analysis the residual motion artifact in 4D-CT scan using a simple one-dimension theoretical model and also we developed a simulation program. Our results explain the effect of residual motion on each phase target displacement and also shown that residual motion artifact was affected that the target velocity at each phase. In this study, we focus on provides a more intuitive understanding about the residual motion artifact and try to explain the relationship motion parameters of the scanner, treatment couch and tumor. In conclusion, our results could help to decide the appropriate reconstruction phase and CT parameters which reduce the residual motion artifact in 4DCT.

The Application of Dynamic Acquisition with Motion Correction for Static Image (동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정)

  • Yoon, Seok-Hwan;Seung, Jong-Min;Kim, Kye-Hwan;Kim, Jae-Il;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • Purpose: The static image of nuclear medicine study should be acquired without a motion, however, it is difficult to acquire static image without movement for the serious patients, advanced aged patients. These movements cause decreases in reliability for quantitative and qualitative analysis, therefore re-examination was inevitable in the some cases. Consequently, in order to improve the problem of motion artifacts, the authors substituted the dynamic acquisition technique for the static acquisition, using motion correction. Materials and Methods: A capillary tube and IEC body phantom were used. First, the static image was acquired for 60 seconds while the dynamic images were acquired with a protocol, 2 sec/frame${\times}$30 frames, under the same parameter and the frames were summed up into one image afterwards. Also, minimal motion and excessive motion were applied during the another dynamic acquisition and the coordinate correction was applied towards X and Y axis on the frames where the motion artifact occurred. But the severe blurred images were deleted. Finally, the resolution and counts were compared between the static image and the summed dynamic images which before and after applying motion correction, and the signal of frequency was analysed after frequency spatial domain was transformed into 2D FFT. Supplementary examination, the blind test was performed by the nuclear medicine department staff. Results: First, the resolution in the static image and summed dynamic image without motion were 8.32 mm, 8.37 mm on X-axis and 8.30 mm, 8.42 mm on Y-axis, respectively. The counts were 484 kcounts, 485 kcounts each, so there was nearly no difference. Secondly, the resolution in the image with minimal motion applying motion correction was 8.66 mm on X-axis, 8.85 mm on Y-axis and had 469 kcounts while the image without motion correction was 21.81 mm, 24.02 mm and 469 kcounts in order. So, this shows the image with minimal motion applying motion correction has similar resolution with the static image. Lastly, the resolution in the images with excessive motion applying motion correction were 9.09 mm on X-axis, 8.83 mm on Y-axis and had 469 kcounts while the image without motion correction was 47.35 mm, 40.46 mm and 255 kcounts in order. Although there was difference in counts because of deletion of blurred frames, we could get similar resolution. And when the image was transformed into frequency, the high frequency was decreased by the movement. However, the frequency was improved again after motion correction. In the blind test, there was no difference between the image applying motion correction and the static image without motion. Conclusion: There was no significant difference between the static image and the summed dynamic image. This technique can be applied to patients who may have difficulty remaining still during the imaging process, so that the quality of image can be improved as well as the reliance for analysis of quantity. Moreover, the re-examination rate will be considerably decreased. However, there is a limit of motion correction, more time will be required to successfully image the patients applying motion correction. Also, the decrease of total counts due to deletion of the severe blurred images should be calculated and the proper number of frames should be acquired.

  • PDF

Development of Wireless Ambulatory Measurement System based on Inertial Sensors for Gait Analysis and its Application for Diagnosis on Elderly People with Diabetes Mellitus (관성센서 기반의 무선보행측정시스템 개발 및 노인 당뇨 환자 보행 진단에의 응용)

  • Jung, Ji-Yong;Yang, Yoon-Seok;Won, Yong-Gwan;Kim, Jung-Ja
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.2
    • /
    • pp.38-46
    • /
    • 2011
  • 3D motion analysis system which is currently widely used for walking analysis has limitations due to both necessity of wide space for many cameras for measurement, high cost, and complicated preparation procedure, which results in low accessability in use and application for clinical diagnosis. To resolve this problem, we developed 3-dimensional wireless ambulatory measurement system based on inertial sensor which can be easily applicable for clinical diagnosis for lower extremity deformity and developed system was evaluated by applying for 10 elderly people with diabetes mellitus. Developed system was composed of wireless ambulatory measurement module that consists of inertial measurement unit (IMU) which measures the gait characteristics, microcontroller which collects and precesses the inertial data, bluetooth device which transfers the measured data to PC and Window's application for storing and processing and analyzing received data. This system will utilize not only to measure lower extremity (foot) problem conveniently in clinical medicine but also to analyze 3D motion of human in other areas as sports science, rehabilitation.

Augmented Reality Game Interface Using Hand Gestures Tracking (사용자 손동작 추적에 기반한 증강현실 게임 인터페이스)

  • Yoon, Jong-Hyun;Park, Jong-Seung
    • Journal of Korea Game Society
    • /
    • v.6 no.2
    • /
    • pp.3-12
    • /
    • 2006
  • Recently, Many 3D augmented reality games that provide strengthened immersive have appeared in the 3D game environment. In this article, we describe a barehanded interaction method based on human hand gestures for augmented reality games. First, feature points are extracted from input video streams. Point features are tracked and motion of moving objects are computed. The shape of the motion trajectories are used to determine whether the motion is intended gestures. A long smooth trajectory toward one of virtual objects or menus is classified as an intended gesture and the corresponding action is invoked. To prove the validity of the proposed method, we implemented two simple augmented reality applications: a gesture-based music player and a virtual basketball game. In the music player, several menu icons are displayed on the top of the screen and an user can activate a menu by hand gestures. In the virtual basketball game, a virtual ball is bouncing in a virtual cube space and the real video stream is shown in the background. An user can hit the virtual ball with his hand gestures. From the experiments for three untrained users, it is shown that the accuracy of menu activation according to the intended gestures is 94% for normal speed gestures and 84% for fast and abrupt gestures.

  • PDF

Fundamentals of Contact Lens Movement (콘택트렌즈 운동의 기초)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.5-13
    • /
    • 2008
  • Purpose: This review article was written to investigate what kind of forces are acting on the contact lens fitted on the cornea and its subsequent motion. Methods: A capillary action-induced force develops in the tear layer between the lens and cornea, which leads to the restoring force due to difference in layer thickness according to lens rotation. The characteristics of the lens movement can be determined by the various factors such as friction between eyelid and lens, acceleration force based on blinking and the restoring force incorporated with the viscous damping force. A mathematical model which consists of the differential equations and their numerical solution was proposed to analyze the damped motion of lenses. The model predicts the time dependence of lenses during and after the blink varying the BC, blink period and eyelid pressure. Results: It was found that both the blink period and lid pressure increases the movement increases because of the enhanced lid friction. As the BC increases the viscous damping reduces due to the lacrimal layer's increase which resulted in the enhanced lens motion. After blink the lens illustrates the damped oscillation because of the restoring force by the increased lacrimal layer thickness and reduced viscous resistance. The time for the lens to return to the equilibrium shortens as the BC increase because of the resistance reduction. Conclusions: The movement of the contact lens is governed by the characteristics of the lacrimal layer between the lens and cornea as well as the lid blink.

  • PDF

Efficient Vibration Analysis of Stadium Stands (경기장 관람석의 효율적인 진동해석)

  • 김기철;이동근
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.2
    • /
    • pp.293-303
    • /
    • 2002
  • Recently, the use of the high strength materials and development of construction techniques have resulted in more flexible and longer spanning in the stadium systems. So the natural frequency of stadium structures are became low. Stadium stand could be led to significant dynamic response as like resonance due to spectator rhythmical activities. The accurate analysis of dynamic behavior of stadium systems and the precise investigation of the dynamic loads on stadium structures are demanded for effective design. It is desirable to apply measured dynamic loads created by spectator activities because these dynamic loads are not easy to express numerical formula. As the floor mesh of stadium stand is refined, the number of divided elements increases in numerical analysis. the rise of the number of elements makes the numbers of nodal points increased and numerous computer memory required. So it is difficult to analysis refine full model of stadium structures by using the commercial programs. In this study, the various dynamic loads induced by spectator movements are measured and analyzed. And a new modeling method that reduce the nodal points are introduced. Vibration analysis of stadium stands is executed to inspect accuracy and efficiency of proposed method in this paper.

Effectiveness of Transcranial Direct Current Stimulation(tDCS) on Upper Extremity Function in Stroke Patients : A Systematic Review and Meta-Analysis (뇌졸중 환자의 상지기능에 대한 경두개 직류자극술 효과 : 체계적 고찰 및 메타분석)

  • Won, Kyung-A;Yang, Min Ah;Park, Hae Yean;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.9 no.1
    • /
    • pp.7-23
    • /
    • 2020
  • Objective : The purpose of this article was to analyze the effects of tDCS on the recovery of upper limb function in stroke patients. Methods : We searched for papers published in journals between 2009 to 2018, using NDSL and RISS. A total 14 experimental research papers were selected for analysis. The quality of the 14 articles was evaluated using the PEDro scale and 12 articles were analyzed through the Comprehensive Meta Analysis 3.0 program. Results : All of the 14 articles that were systematically reviewed in this study were published in foreign journals. The effect sizes for upper extremity(U/Ex) strength and U/Ex motion were 0.19(small size effect) and 0.49(medium size effect) respectively. Furthermore, the effect sizes of anode mode and cathode mode were 0.71(large size effect) and 0.41(medium size effect), respectively. The effect size of U/Ex motion and the anode mode were statistically significant(p<0.05). Conclusion : We identified that tDCS can be a useful rehabilitation technique for stroke patients with limited upper body function. These findings are expected to help with suggestions for basic data on new rehabilitation techniques for stroke patients and the planning of effective interventions.

The Case Study of Reflective Practice of the Liberal Dance Class in University (대학 교양무용 수업의 반성적 실천 사례)

  • Park, Ji-Won;Kim, Je-Young;Kim, Ji-Young
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.626-635
    • /
    • 2013
  • The purpose of this study is to research the practical cases of the reflective curriculum design and the improvement of the dance courses as a general education at University. This study deals with the recreation dance program with 40 students participating for 15 weeks. This study is qualitative research to explore the practical meaning and value the process on the basis of the interviews and reports of the students and the class evaluation of the instructors. The results were as follows: First is the experience of 'thinking dance'. Not just a functional movement, but moreover, they could experience the attraction, sensitivity and culture of the dance altogether. Second is the experience of 'communicating dance'. They experienced the sociability from the relationship with new partners, the overcome of the passivity (shyness) and the manner of consideration. The third is the experience of 'creating dance together'. As a member of a group, they could learn the integrity, responsibility and satisfaction in the middle of cooperative task performance. The view from the teacher regarding the class reflective assessment is as followed: The importance of dance instruction is to improve the expressive personality and potentiality of the students. Forcing the students to follow the basic choreography could be exhaustive.

A Study on the Architectural Environment as a Combination of Performance and Event (퍼포먼스.이벤트의 결합체로서 건축환경연구)

  • 김주미
    • Archives of design research
    • /
    • v.14
    • /
    • pp.121-138
    • /
    • 1996
  • The purpose of this study is to develop a new architectural language and design strategies that would anticipate and incorporate new historical situations and new paradigms to understand the world. It consists of four sections as follows: First, it presents a new interpretation of space, human body, and movement that we find in modern art and tries to combine that new artistic insight with environmental design to provide a theoretical basis for performance-event architecture. Second, it conceives of architectural environment as a combination of space, movement, and probabilistic situations rather than a mere conglomeration of material. It also perceives the environment as a stage for performance and the act of designing as a performance. Third, in this context, man is conceived of as an organic system that responds to, interacts with, and adapts himself to his environment through self-regulation. By the same token, architecture should be a dynamic system that undergoes a constant transformation in its attempt to accommodate human actions and behaviors as he copes with the contemporary philosophy characterized by the principle of uncertainty, fast-changing society, and the new developments in technology. Fourth, the relativistic and organic view-point that constitutes the background for all this is radically different from the causalistic and mechanistic view that characterized the forms and functions of modernistic design. The present study places a great emphases on dematerialistic conception of environment and puts forth a disprogramming method that would accommodate interchangeability in the passage of time and the intertextuality of form and function. In the event, performance-event architecture is a strategy based on the systems world-view that would enable the recovery of man's autonomy and the reconception of his environment as an object of art.

  • PDF

An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.