• Title/Summary/Keyword: 운동정밀도

Search Result 694, Processing Time 0.04 seconds

Measurement of Motion Accuracy by Two-dimensional Probe on NC Machine Tools -2nd Report, Measurement of the Linear Motion Accuracy- (2차원 프로브에 의한 NC공작기계의 운동 정밀도 측정 -제2보 직선운동 정밀도 측정-)

  • JEON, Eon Chan;OYAMADA, Shigenori;TSUTSUMI, Masaomi;KAKUTA, Junichro
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.7
    • /
    • pp.15-21
    • /
    • 1997
  • This paper presented a linear motion accuracy by using two-dimensional probe with the master block and the square for NC machine tools. This measuring system could be measured motion error due to numerical control system. The results of measurement and simulation for motion error were similar, and so, this system had enough accuracy to measure a linear motion accuracy for NC machine tools. The experimental results are as follows. 1. This measuring system could be measured motion error due to mumerical control system. 2. The results of measurement and simulation for motion error were similar. 3. This measuring system had enough accuracy to measure a linear motion accuracy for NC machine tools.

  • PDF

Design of a high Precision stage and a multi-segmented magnet way linear motor for high precision machine (초정밀 가공기를 위한 다극자석 선형 모터와 초정밀 스테이지 설계)

  • 김기현;이문구;김동민;권대갑;조형석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.56-61
    • /
    • 2003
  • 본 논문은 초정밀 가공기에 적용 가능한 6자유도의 운동이 가능한 초정밀 스테이지의 설계를 기술한다. 본 초정밀 스테이지는 특히, 광학을 이용한 가공기와 절삭력이 작은 가공기에 적합하다. 스테이지는 장행정 · 단행정 스테이지로 구성된 이중 서보를 채택한다 장행정 스테이지는 초정밀 운동에 방해가 되는 운동을 줄이며 높은 효율을 갖는 다극 자석 배열을 이용한 선형모터를 사용한다. 그리고 단행정 스테이지는 장행정 스테이지와의 기계적 결합에 의한 구조적 영향성을 없애는 개념을 적용할 수 있는 보이스 코일 모터을 이용한다. 그리고 각 구동부는 최상의 성능을 유지할 수 있도록 최적설계를 수행한다.

  • PDF

The design of Vibration Isolation for Ultra-Precision Machine (초정밀 가공기의 방전시스템 설계기술연구)

  • 박종권
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.171-176
    • /
    • 1993
  • 초정밀 공작기계의 구조물은 Sub-micron의 운동정밀도를 갖추어야 초정밀기계로서의 기능이 유지된다. 특히 가공기의 베드구조물은 구동요소간의 상대 위치를 정.동적으로 규정 해주는 중요한 기본구조물이므로 고강성, 고쇠감성,열안정성, 경년변화에 대한 치수의 안정성등의 성능이 요구되며, 이를위해 공간적인 형상 설계 및 구조재의 선정에 고도의 기술이 필요하다. 따라서 본 연구는 낮은 고유진동수의 특성을 갖으면서 하중의 설치높이의 변화에서도 고유진동수가 일정히 유지되고 또한 구조물의 중심변화에 대한 수평조절이 가능하면서 자동제어가 가능한 공기스프링을 초정밀 가공기의 방진시스템으로 활용방안에 대하여 연구하였다.

  • PDF

비구면 가공을 위한 속도 파형 및 제어 알고리즘

  • 김형태;양해정
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.197-197
    • /
    • 2004
  • 일반적으로 가공기는 주로 직선 운동 축과 회전 운동 축으로 구성되어 있으며, 여러 개의 축의 조합에 의하여 원하는 경로를 얻어내게 된다 여러 축이 조합이 되더라도 대부분 가공 동작의 경우는 하나의 축에 의한 단축 운동으로 충분히 만족할 만한 결과를 얻을 수 있다. 그러나, 금형 가공이나 렌즈가공 등은 단순한 회전이나 직선의 조합에 의한 곡선이 아닌 임의의 함수에 의한 곡선이므로 이러한 경우 2축 이상을 적절히 이동시켜서 원하는 형상을 얻어야 한다.(중략)

  • PDF

전조 볼 나사 BCD 측정기 개발에 관한 연구

  • 이춘만;임상헌;김현철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.184-184
    • /
    • 2004
  • 볼 나사는 반도체ㆍLCDㆍPDP 등 전자제품 조립장비 제조업체와 CNC 공작기계, 정밀측정기계, 직교좌표로봇, 반송장치, 항공기용 유압구동장치 대체품, 전동공구, 파워 steering, 테이블 개폐장치 등에서 구동 장치 및 물품의 이송을 위해 대부분 사용되는 중요한 기계요소 중의 하나이다. 그것은 회전운동을 직선운동으로 전환해주는 기구부에 들어가는 가장 중요한 부품이며, 원통형의 봉에 나선형의 그루브를 가공한 장축의 나사와 단축의 너트 사이에 볼을 게재시켜 축의 회전 시 적은 구름마찰로 인해, 너트부가 직선 운동하는데 원활 하게 만들어진 기계요소이다.(중략)

  • PDF

Finite Element Analysis on the Motion Accuracy of Double-sides Hydrostatic Table (양면지지형 유정압테이블 운동정밀도의 유한요소 해석)

  • 박천홍;정재훈;이후상;이찬홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.188-192
    • /
    • 2000
  • An analysjs model for calculation the motion accuarcy of double sides hydrostatic table is proposed in thn paper. For the analysis of motion accuracy, profiles of each rails are assumed as periodic function, and represented using Fourier coefficients. Variahon of bearing clearance is represented as the vanation of linear, angular displacement of table and profiles of rails. Motion accuracy is calculated in the basis of finite element analysis on the pressure dutributmn of table. In order to improve calculating time in the analysis of motion accuracy, The proposed modeling method converts double sides table to single side table equivalently Results by the proposed method 1s compared with directly caculated results mdyhcally, and also compared wlth experimental results. From the theoretical and experimental analysis, it is confirmed that the proposed modeling mothod is very effective to analyze the motion accuracy of dauble sides hydrostatic table.

  • PDF

Analysis of the Motion Accuracy in Linear Motion Bearing Guide (직선베어링 이송계의 운동정밀도 해석)

  • 김경호;이후상;박천홍;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.179-183
    • /
    • 2000
  • This paper is concerned with achieving the high motion accuracy of linear motion bearing guide according to estimate accuracy average effect of bearing. Accuracy average effect can be obtained b analysis the relationship between motion error of the table and spatial frequency of the rail form error. And influences of ball diameter, ball number, and clock length on block motion error and block number on the table motion error are analyzed theoretically. In addition to, a simple experiment is performed in order to verify theoretical result.

  • PDF

Measurement of motion accuracy by two-dimensional probe on NC machine tools -1st report, Measurement of the circular motion accuracy- (2차원 프로브에 의한 NC공작기계의 운동정밀도 측정 -제 1보 원호보간운동 정밀도 측정-)

  • JEON, Eon-Chan;OYAMADA, Shigenori;TSUTSUMI, Masaomi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.3
    • /
    • pp.56-62
    • /
    • 1996
  • This paper presented a new measuring system to improve circular motion accuracy by using two-dimensonal probe and master ring for NC machine tools. This measuring system reduced the circular motion error conspicuously by eliminating the influence of the acceleration/deceleration range and compensating the friction force whose influences were significant while measuring the motion. Experimental results show that this system had enough accuracy to measure a circular motion for NC machine tools, compared with the circular test method and the r .theta. method.

  • PDF

Finite Element Analysis on the Motion Accuracy of Hydrostatic Table ($2^{nd}$. Analysis and Experimental Verification on Double Sides Table) (FEM을 이용한 유정압테이블의 운동정밀도 해석 (2. 양면지지형 테이블의 해석 및 실험적 검증))

  • Park, Chun-Hong;Lee, Hu-Sang;Kim, Tae-Hyoung;Kim, Min-Gi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.65-70
    • /
    • 2002
  • An analysis method for calculating motion accuarcy of double sides hydrostatic table is proposed in this paper. In this method, profiles of each rails are assumed as periodic function, therefore it is represented as the sum of spacial frequencies. Bearing clearance at any position rail is depended on the variation of linear, angular motion error of table and the form errors of both sides of a rail. Finite element method is applied to calculate pressure distributions in bearing clearance. In order to simplify the analyzing process, double sides table model is converted into equivalent single side table model. Results calculated by the proposed modeling method agree well with the results directly caculated by double sides modeling method, and also agree well with experimental results. From the theoretical and experimental analysis, it is verified that the proposed analysis method is very effective to analyze the motion accuracy of double sides hydrostatic table.