• Title/Summary/Keyword: 우위대망동맥

Search Result 15, Processing Time 0.02 seconds

Routine Off-pump Total Arterial Coronary Revascularization (심폐바이때스 없이 시행된 동맥 도관만를 이용한 관상동맥 완전 재관혈화)

  • Lee, Jae-Won;Park, Nam-Hee;Kang, Seong-Sik;Choo, Suk-Jung;Park, Seung-Jung;Park, Seung-Wook;Hong, Myeong-Ki;Song, Hyun;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.309-315
    • /
    • 2003
  • Background: To avoid the adverse effects of cardiopulmonary bypass and to overcome late vein graft failure we routinely peformed off-pump total arterial coronary revascularization. Material and Method: From July 2000 to August 2001, 104 consecutive patients underwent first elective off-pump total arterial coronary revascularization. Both internal mammary, radial and gastroepiploic arteries were used. Sequential and composite grafts were used to achieve complete revascularization. Perioperative adverse events and postoperative angiograms were analyzed. Result: A total of 252 arterial conduits were used with an average of 2.47 grafts per patient. A total of 326 distal anastomosis were performed with a mean of 3.13 distal anastomosis per patient. Cross over to on-pump occurred in seven patients (6.7%). Of these 4 were due to unstable hemodynamics during lateral or posterior wall stabilization as a result of cardiomegaly and 3 were due to uncontrolled bleeding during dissection of diffusely dimunitive deeply placed intramyocardial coronary arteries. There were no opeartive deaths. Two cases of perioperative myocardial infarction and transient neurologic complications occurred, respectively. Of the 312 distal anastomoses, 308 (98.7%) were compatible with Fitz-Gibboll A or B patency grading. Conclusion: Off-pump total arterial coronary revascularization was technically feasible in most elective cases with satisfactory early results. However, on-pump coronary bypass surgery should be considered in difficult circumstances, such as cardiomegaly or unfavorable anatomy of the target coronary artery.

Total Arterial Revascularization Using Y-composite Graft for Isolated Left Main Coronary Artery Disease (단독 좌주간 관동맥 협착병변에서 Y-도관을 이용한 완전 동맥도관 관상동맥우회로 조성술)

  • Ahn, Byong-Hee;Yu, Ung;Chun, Joon-Kyung;Ryu, Sang-Wan;Choi, Yong-Sun;Kim, Byong-Pyo;Hong, Sung-Bum;Bum, Min-Sun;Na, Kook-Ju;Jung, Myung-Ho;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.35-42
    • /
    • 2004
  • Background: For the treatment of isolated left main coronary artery disease, twelve arterial revascularizations with Y-composite grafts using left internal thoracic artery and radial artery or right gastroepiploic artery were peformed. This study was performed to investigate whether V-composite graft can satisfy the blood flow required to make myocardium act properly or not. Borderline stenotic lesions on the left main coronary artery, which are very prone to remodel the bypassed vessels due to competitive flows, were also considered. Material and Method: Among 247 patients who underwent coronary artery bypass grafting from March 2000 to April 2003, 12 patients (4.7%) who had received total arterial revascularizations for the isolated left main coronary artery disease were studied retrospectively. Result: left anterior descending arteries were bypassed with left internal thoracic artery by off-pump technique in all patients, however, 2 cases of left obtuse marginal branches were bypassed under on-pump beating heart. Except for one patient, who did not have an obtuse marginal branch more than 1 mm in diameter, 11 patients had gone through complete arterial revascularizations by use of the Y shape arterial graft. Among five patients who had less than 75% stenosis, one patient showed string sign on left internal thoracic artery grafted to left anterior descending artery. However, two grafts to obtuse marginal blanches were completely obstructed and one showed slender sign. There were no graft-dominant flow in patients with stenotic lesion less than 75%. On the contrary to the result of patients with stenotic lesions less than 75%, all the patients with stenotic lesions more than 90% showed graft-dominant blood flow. Conclusion: In conclusion, it is assumed that, when stenotic lesions are over 90%, coronary artery bypass grafting with an Y shape arterial graft could possibly give enough help to the obstructed coronary arteries in blood supplying to myocardium, which needs massive quantity of blood to act well. However, when patients have borderline stenoses, through scrupulous examinations, more prudent and flexible decisions are required in choosing the treatment methods, such as, direct anastomosis of vein or artery to aorta, or adding supplementary treatment methods like percutaneous coronary intervention, rather than choosing a fixed treatment methods.

Conceptual framework for Emotions in Usability of Products (제품 사용성과 감성에 관한 개념적 연구)

  • Lee Kun-Pyo;Jeong Sang-Hoon
    • Science of Emotion and Sensibility
    • /
    • v.8 no.1
    • /
    • pp.17-28
    • /
    • 2005
  • With the advent of computer technology, the fundamental nature of products has shaped from physical forms towards product interactivity, The focus is now on usability of the product with ease and efficiency rather than conversing with just the looks of the product. However, most definitions of usability and contemporary usability-related researches, have focused on the performance-oriented functional aspects of usability (i.e., how well users perform tasks using a product). Today, user expectations are higher; products that bring not only functional benefits but also emotional satisfaction. So far, there have been many studies on human emotions and the emotional side of products in the field of emotional engineering. Contemporary emotion-related researches have focused mainly on the relationship between product aesthetics and the emotional responses elicited by the products, but little is known about emotions elicited from using the products. The main objective of our research is analyzing user's emotional changes while using a product, to reveal the influence of usability on human emotions. In this research, we suggested conceptual framework for the study on the relationship between usability of products, and human emotions with emphasis on mobile phones. We also extracted emotional words for measuring user's emotions expressed not from looking at the product's appearance, but from using the product. First, we assembled a set of emotions that is sufficiently extensive to represent a general overview of the full repertoire of Korean emotions from the literature study. Secondly, we found emotional words in the after note by the users on the websites. Finally, verbal protocols in which the user says out loud what he/she ks feeling while he/she ks carrying out a task were collected. And then, the appropriateness of extracted emotional words was verified by the members of the consumer panel of a company through web survey. It is expected that emotional words extracted in this research will be used to measure user's emotional changes while using a product. Based on the conceptual framework suggested in this research, basic guidelines on interface design methods that reflect user's emotions will be illustrated.

  • PDF

Histological Characteristics of Right Gastroepiploic Artery for Coronary Artery Bypass Graft (관상동맥우회 이식편으로서의 우위대망동맥의 조직학적 특징)

  • Lee, Hyun-Woo;Song, Hyun;Yoo, Dong-Gon;Lim, Han-Jung;Lee, Jae-Won;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.32 no.10
    • /
    • pp.883-890
    • /
    • 1999
  • Long term patency of arterial graft has been better than venous graft and redo coronary artery bypass grafting has been increasing, therefore, there has been an increasing need for alternative arterial grafts except internal thoracic artery(ITA). Material and Method: Right gastroepiploic arteries(RGEA) were harvested from 100 patients who had received gastrectomy for gastric cancer or ulcer. ITAs were obtained from 10 patients undergoing coronary artery bypass grafting. The length of RGEA was measured from the pyloric ring. Items of the morphometric and histologic study at the pyloric ring and sites of the 10cm and 20cm RGEA from the pyloric ring were luminal diameter, intimal thickness, medial thickness, wall thickness, degree of intimal hyperplasia, intimal thickness, medial thickness, wall thickness, degree of intimal hyperplasia, intimal thickness index, medial thickness index, and the number of discontinuities of the internal elastic lamina. Similar items were applied to the proximal site of ITAs. Result: The length of RGEA was 23${\pm}$2.7cm(range 17∼31cm). Comparing the 20cm RGEA with ITA, intimal thickness, medial thickness, wall thickness, and degree of intimal hyperplasia did not show any difference(p>0.05). However, 20cm RGEA was greater than ITA at the luminal diameter, intimal thickness index, and the number thickness and wall thickness in each site of the RGEA(pyloric ring, 10cm, 20cm) decreased from the pyloric ring to the distal sites(p<0.05). The degree of intimal hyperplasia and the number of discontinuities of the internal elastic lamina did not show any difference between the pyloric ring and 10cm, however, those of 20cm were smaller than these sites(p<0.05). RGEA had more number of discontinuities of the internal elastic lamina and rich smooth muscle cells in the media than ITA. Conclusion: The length and diameter of RGEA is good enough to reach most of the coronary arteries. Moreover, long term patency of RGEA may be improved, if anastomosed in the distal site.

  • PDF

Comparative Analysis of Image Quality and Adverse Events between Iopamidol 250 and Ioversol 320 in Hepatic Angiography for Transcatheter Arterial Chemoembolization (경동맥 화학색전술을 위한 간동맥 혈관조영술에서 Ioversol 320과 비교한 Iopamidol 250의 영상 화질 비교 분석과 조영제 유해반응 평가)

  • Min Jae Gu;Jae Hyuck Yi;Young Hwan Kim;Hee Jung Lee;Ung Rae Kang;Seung Woo Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.166-175
    • /
    • 2020
  • Purpose This study aimed to compare the image quality and adverse events between Iopamidol 250 and Ioversol 320 usage during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Materials and Methods Medical records and hepatic angiography from 113 patients who underwent TACE with Iopamidol 250 (44 patients) and Ioversol 320 (69 patients) were retrospectively reviewed. Vessel perception on hepatic angiography was graded into three categories by two radiologists for hepatic subsegmental arteries, the right gastroepiploic artery, right gastric artery, and pancreaticoduodenal artery. Imaging concordance was assessed by comparing the number of detected HCCs on hepatic angiography and CT. The adverse events before and after hepatic angiography were evaluated. Results The mean vessel perception scores were 2.92 and 2.94 for Iopamidol 250 and Ioversol 320, respectively. The imaging concordance was 31 (70.5%) and 46 (66.7%) patients for Iopamidol 250 and Ioversol 320, respectively. There were no statistical differences in vessel perception or imaging concordance (p > 0.05). One and six patients experienced nausea for Iopamidol 250 and Ioversol 320, respectively. There was no statistical difference in adverse events (p = 0.24). Conclusion Iopamidol 250 can be used in hepatic angiography for TACE without significant difference in image quality or occurrence of adverse events from Ioversol 320.