1Cr-0.5Mo강 용접부 균열의 고온파괴거동 연구 (A Study on Elevated Temperature Fracture Behavior of Cracks in 1Cr-0.5Mo Steel Weld)

  • 신규인;윤기봉;최현창;박재학;이해무
    • 한국안전학회지
    • /
    • 제12권2호
    • /
    • pp.45-56
    • /
    • 1997
  • Fracture behavior of ex-serviced 1Cr-0.5Mo steel was measured at room($24^{\circ}C$) and elevated($538^{\circ}C$) temperature and compared with that measured with virgin 1Cr-0.5Mo steel. Compact C(T) specimens were machined from the base and welded test materials. In case of the C(T) specimens of the weld, fatigue precrack was introduced along the fusion line so that following crack growth should occurs along the region of heat affected zone. It was observed that the J-R curve of the serviced material was significantly lower than that of the virgin material at room temperature. Brittle fracture was observed in the serviced material. On the other hand, at elevated temperature no noticeable difference was found between the J-R curves of the virgin and the serviced material. The measured J-R curves were also compared with those of the 1.25Cr-0.5Mo steel obtained from the other literatures. Optical microscopy and SEM examination of the serviced material reveal the carbide in/along the grain boundary which shows material degradation due to long-term usage. An example of application of the measured J-R curves is shown.

  • PDF

냉간체결방법을 이용한 대형 주철 구조물의 피로손상수리방법에 대한 연구 (A Study on the Repair of Fatigue Damage at Large Cast Iron structure using Cold Joint Method)

  • 이성룡;이동준;조석수
    • 한국산학기술학회논문지
    • /
    • 제20권10호
    • /
    • pp.140-148
    • /
    • 2019
  • 대형 주철 구조물은 선박이나 화학 플랜트등에서 케이싱이나 대형 파이프등으로 사용되고 있다. 그러나 대형 케이싱이나 파이프에서 발생되는 파괴는 대부분 해당 재료의 항복강도아래에서 발생된다. 대형 주철 구조물의 피로 파손은 설계 제한조건과 낮은 재료 강도 신뢰성등으로 인하여 발생되고 있다. 파손된 소형 주철 구조물은 시중에서 판매되는 주철 용접봉으로 보수가 가능하다. 그러나 파손된 대형 주철 구조물이 보수 용접으로 보수되려면 구조물 전체가 균일하게 가열되어 냉각되어져야 하나 현장에서는 그와 같은 가열장치를 설치하는 것이 불가능한 장소가 많다. 따라서 현재에도 선박과 플랜트 현장등에서는 파괴된 주철 구조물을 수리의 간편성으로 인하여 냉간 용접만하여 재사용하고 있고 이로 인한 피로 파괴가 재발생 되어져 파괴로 인한 손실 비용이 과대하게 발생하고 있다. 본 연구에서는 이러한 문제점을 해결하기 위하여 파손된 대형 주철 구조물을 균열보수나사를 이용하여 파손된 부분을 기계적으로 결합하는 방법을 제안하여 피로 파괴된 대형 주철 구조물 보수 방법을 제안하였다. 균열보수나사로 보수한 GC 300의 노치 시험편을 인장시험한 결과 8.2 MPa정도의 인장 강도를 가지고 있어 GC 300으로 제작한 대형 열교환기나 가열기의 설계응력이 3.5 MPa이하인 것을 고려하면 안전율이 2.3이상이 되어져 균열보수나사를 이용하여 대형 주철 구조물 균열을 보수하는 방법이 공학적으로 매우 유용하다.

Ilmenite계(系) 아아크용접봉(鎔接棒)의 Penetration에 관(關)한 실험적(實驗的) 연구(硏究) (An Experimental Study on the Penetration of Ilmenite System Coated Arc Welding Electrodes)

  • 박종은
    • 대한조선학회지
    • /
    • 제6권1호
    • /
    • pp.35-42
    • /
    • 1969
  • Penetrations of arc welding electrades are different by changing welding conditions, welding speed of travel and current, even though quite same ones. Changing status of penetration is studied by changing welding speed of travel keeping welding current constant, at first, and by changing welding current keeping welding speed of travel which was obtained prior experiment constant, afterward. The F-100 4mm $\phi$ rods, E4301 class, which covering substance is mainly ilmenite and a domestic representative product of this class electrode, are used for this experiment. The Marquette's No.130 5/32"(4mm)$\phi$ rods, E6011 class, and No. 140 5/32"(4mm)$\phi$, E6013 class, which were produced in the United Stated, are used to compare penetration with F-100 at same welding conditions. The covering substance of Marquette's No. 130 rods is mainly cellulose, and belong to deep penetration arc welding electrodes, the covering material of another rods is titania, and a kind f shallow penetration rods. The result of this study is as follow : penetration of F-100, domestic ilmentite covering electrade, E4301 class, is between E6011 and E6013 of the United States products. At the lower range of welding current, penetration is closer to E6013 than E6011, at the higher range, closer to E6011 than another; and the value of penetration ranges $1.65{\sim}2.70mm$ for 4mm$\phi$ rods in the adequate current range. The changing status of penetration is showed by following experimental formula. $P=KE_v^{-\frac{2}{5}}1^{\frac{3}{2}}$

  • PDF

소형펀치 시험을 이용한 API 5L X65 강의 수소취화에 관한 연구 I : 모재부 (Study on Hydrogen Embrittlement for API 5L X65 Steel Using Small Punch Test I : Base Metal)

  • 장상엽;윤기봉
    • 에너지공학
    • /
    • 제18권1호
    • /
    • pp.49-55
    • /
    • 2009
  • 금속의 수소취화는 수소를 사용하는 설비의 안전성을 위협하는 중요한 문제이므로, 수소 환경에서 금속의 취화평가법에 관한 연구의 필요성이 요구되고 있다. 수소사회를 대비하기 위하여 대용량의 수소공급방법에 관한 연구가 진행되고 있는데, 기존의 천연가스 배관을 통한 공급방안이 검토되고 있다. 본 연구에서는 배관 내부에 수소혼합가스가 흐르면 배관모재부 및 용접부의 손상이 우려되므로, 국내에 건설되어 운용되고 있는 X65 천연가스 배관의 모재부를 대상으로 수소취화 거동에 대하여 연구하였다. 재료의 수소침투는 전기분극법을 사용하였으며 강도평가에는 소형펀치시험법을 사용하였다. 수소장입량의 증가에 따라서 금속의 강도가 저하되는 현상이 발견되는 재료도 있으나, 본 연구에 사용한 X65강의 모재부에서 수소취화의 영향은 거의 나타나지 않았으므로 수소영향에 의한 X65강 모재부의 강도저하는 발생하지 않는 것으로 판단된다. 또한 소형펀치시험을 이용함으로써 금속재료의 수소취화에 의한 기계적 강도변화를 평가할 수 있었다.

도로 폭이 좁은 굴착공사에서 연결부가 적용되는 장지간 주형의 수치해석적 거동 평가 (Numerical Analysis on the Structure Behavior of the Connected Long-span Beam during Excavation in Narrow Streets)

  • 최광수;하상봉;이환우
    • 한국전산구조공학회논문집
    • /
    • 제33권4호
    • /
    • pp.263-270
    • /
    • 2020
  • 본 연구의 대상은 도로 폭이 좁은 시가지에서 굴착공사 시 적용되는 장지간 주형의 연결부이다. 일반적으로 적용되고 있는 연결부에서 상부 플랜지의 단차와 피로균열 등의 문제로 연결부의 신뢰도가 저하된다. 연결부의 결함을 보완하고 안전성을 향상시킨 개선형 연결부를 개발하였다. 유한요소 기반의 상용프로그램(ABAQUS)를 이용하여 개선형 연결부의 거동을 평가하였다. 먼저, 개선형 연결부에 적용되는 고장력 볼트 연결 및 강재와 콘크리트의 합성거동을 구현하기 위한 수치해석 방법을 제안하였다. 비교논문의 실험결과와 수치해석 결과의 비교를 통하여 개선형 연결부를 해석하는데 있어 수치해석 방법의 적합성을 검증하였다. 본 연구에서 제안하는 수치해석 방법을 적용하여 개선형 연결부와 일반형 연결부가 적용된 장지간 주형을 해석하였다. 장지간 주형의 탄소성 거동과 연결부의 응력분포를 수치 해석적으로 비교분석하였다. 개선형 연결부의 도입으로 25%의 압축응력이 감소되며 구조적 성능 개선효과 및 안전성을 확인하였다.

GTN 모델을 이용한 X80 라인파이프의 인장 변형성능 해석 (Numerical Assessment of Tensile Strain Capacity for X80 Line Pipe Using GTN Model)

  • 윤영철;김기석;이재혁;조우연
    • 대한토목학회논문집
    • /
    • 제36권6호
    • /
    • pp.979-990
    • /
    • 2016
  • 본 연구는 변형률 기반 설계를 위해 개발된 X80 라인파이프의 인장 변형성능을 검증하기 위해 금속의 비선형 거동을 해석할 수 있는 대표적 경험적인 모델인 GTN (Gurson-Tvergaard-Needleman) 모델을 이용한 비선형 유한요소 해석기법을 제시한다. GTN 모델은 재하과정중 금속 내부에서 발생하는 공극의 생성, 성장, 합체에 대한 모델링을 통해 재료의 손상거동을 묘사하는데, 본 연구에서는 GTN 모델에 대한 사용자 정의 재료모델을 작성하고 상용 유한요소해석 프로그램인 ABAQUS에 연동시켜 강재의 비선형 손상거동을 해석하였다. 비선형 손상해석을 위한 모재와 용접용 재료의 재료상수는 원형봉과 전두께 시편에 대한 인장시험 결과를 수치모사하여 결정하였으며, 결정된 재료상수를 이용하여 SENT (Single Edge Notch Tension) 시험과 CWPT (Curved Wide Plate Test)를 수치모사하였다. 수치해석 결과로부터 인장 변형성능을 산정하고 이를 시험결과 및 기존의 경험공식과 비교한 결과 본 연구에서 개발한 수치기법이 X80 라인파이프 부재의 인장 변형성능을 신뢰도 높게 평가하는 것을 확인하였으며, 결과적으로 변형률 기반 설계에 효과적으로 활용될 수 있을 것으로 기대된다.

원자로 상부헤드 관통노즐의 잔류응력 예측을 위한 노즐 형상 변수 민감도 연구 (Sensitivity Analysis of Nozzle Geometry Variables for Estimating Residual Stress in RPV CRDM Penetration Nozzle)

  • 배홍열;오창영;김윤재;김권희;채수원;김주희
    • 대한기계학회논문집A
    • /
    • 제37권3호
    • /
    • pp.387-395
    • /
    • 2013
  • 최근 국외의 원자로 상부헤드 CRDM 관통노즐에 일차수 응력부식균열로 인한 냉각수 누출사고가 발생하였다. 일차수응력부식균열은 부식에 민감한 재료, 인장 잔류 응력 및 부식 환경 등의 3 가지 요인의 상호작용에 의해 발생하는 것으로 알려져 있기 때문에 응력 부식 균열 발생 및 균열 진전을 억제하기 위해서는 용접에 의한 잔류응력에 대한 정확한 예측이 선행되어야 한다. 본 논문에서는 국내 Westinghouse 형 원자로 상부 헤드 관통노즐(CRDM)을 대상으로 노즐의 두께 및 형상 비($r_o/t$)에 따른 노즐 잔류응력 분포 특성에 대해 연구를 수행하였다. 국내에 현존하는 원자로 상부헤드 관통노즐의 실제크기($r_o$=51.6, t=16.9 mm)를 기준으로 노즐의 두께 및 형상 비($r_o/t$=2, 3, 4)의 변수를 정립하였으며 정중앙 및 최외곽에 위치한 노즐을 대상으로 연구를 수행하였다.