• Title/Summary/Keyword: 용적맥파

Search Result 74, Processing Time 0.023 seconds

Development of 3 Channel Biomedical Signal Measurement System for Mac-yule (맥율용 3채널 생체신호 계측시스템 개발)

  • Byeon, M.K.;Kim, H.J.;Jang, J.K.;Han, S.W.;Huh, W.
    • Journal of IKEEE
    • /
    • v.11 no.1 s.20
    • /
    • pp.24-29
    • /
    • 2007
  • In this paper, we developed a Mac-Yule measurement system which consider psychological stable state of patience. The developed system consist with a hardware device that can derive a EEG, respiration and pulse wave, and a software which acquire a biological signal and signal processing The EEGs are derived with bipolar method from frontal head. The respiration signals obtain from nasal front with a transducer which consist with thermistor bridge. The pulse waves are detected from earlobe with photoplethysmograph method. A power spectrum of EEG are used as the decision parameters of psychological stable state of patience. The decision of Mac-Yule are defined as origin text method that of numbers of pulse to 1 respiration period. As the results of experiment with developed system, we could have a spectrum band discretion of EEG signal, stable respiration signal detection and automatic gain controlled pulse signal with realtime. And then, we could detect Mac-Yules from processed signals.

  • PDF

Design of Motion Artifacts Filter of PPG Signal based on Kalman filter and Adaptive filter (칼만필터와 적응필터를 기반한 PPG 동잡음 제거 필터 설계)

  • Lee, Byeong-Ro;Lee, Ju-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.4
    • /
    • pp.986-991
    • /
    • 2014
  • The PPG signal used in mobile-healthcare and telemedicine system is including the various motion artifact that is signal generated from patient's movements. Recently, although the various methods to remove motion artifacts have been suggested, the performances of these methods are still not satisfactory. Therefore, this s study suggested the novel method based on the Kalman filter and adaptive filter to remove motion artifacts, and we used various motion artifacts to analyze the performance of the proposed method. In the results of experiments, the signal-to-noise ratio of proposed method showed good performace that was 4.8 times of moving average filter.

On Study of Pulse Wave Signal According to Postural Change Using Finger Plethysmography (손가락 끝 용적맥파를 이용한 자세변화에 따른 맥파 신호에 관한 연구)

  • Choi, B.C.;Kim, C.H.;Jung, D.K.;Suh, D.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.125-126
    • /
    • 1998
  • Pulse conduction velocity is determined by areterial compliance, which is changed by lateral pressure of arterial wall. Hydrostatic pressure of the limb vessel is changed by body position, especially in elevated arm. The arterial pulse in the finger causes the blood volume to change, changing the optical density of the blood. Photoplethysmograph of index finger was obtained by LED and phototransistor. Pulse transmission time(PTT) was measured by the interval between the peak of ECG R wave and the peak of the finger plethysmogram. PTT was increased by upward position of arm, and decreased by downward position of the arm compared to horizontal position. This result suggests that relationship between finger plethysmography and postural change could be applied to evaluate clinical cardiovascular status.

  • PDF

Analysis of multi-channel photoplethysmograph parameter by the changes of arterial characteries (동맥계 다채널 용적맥파 특징 파라미터 분석에 관한 연구)

  • Han, Soon-Chen;Kim, Hyoung-Jo;Kim, Hyoung-Tae;Kim, Jung-Kuk;Huh, Woong
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2745-2748
    • /
    • 2003
  • In this paper, we implement the photoplethysmo-graphy system that have three channel pulse wave detects and one channel ECG amplifier. In order to detect the artery state, we measured the pulse waves at different positions, simultaneously. In general, arterial vascular system suffers the decrease of compliance, increase of resistance, and decrease of distensibility through aging. Therefore, we compared and analyzed variation of tile Pulse waves parameter both in time and frequency domains that is concerned with the changes of arterial characteries. And then evaluated the correlation coefficients between the parameters variation and the age group. As the result of experiment, we found that the Parameters have a significant correlation about aging.

  • PDF

Diagnosis of neuropathic foot of diabetics using photo-plethysmography (용적맥파 측정법을 이용한 신경병증 당뇨병 족부질환의 진단)

  • Nam, Ki-Chang;Ryu, Chang-Yong;Jung, Won-Hyuk;Kim, Jin-Tae;Park, Joong-Hoon;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.39-41
    • /
    • 2005
  • The population of diabetes is continuously increasing because of the economic development and the lifestyle modification. If diabetes become chronic condition, it can cause various complications. Among many other complications, diabetic foot is the most fatal issue since it may require amputation of the legs. Diabetic foot has three different types such as neuropathic, neuro-ischemic and ischemic. Among these types, patients of neuropathic foot experience sensory abnormality. Nerve conduction velocity (NCV) is used for diagnosing neuropathic foot but this method uses strong electric stimulus to cause severe pain to the patients In this study, two channel photo-plethysmography was used as noninvasive screening tool for distinguish neuropathic foot and normal group by observing blood flow of both finger and toe simultaneously.

  • PDF

Volume Pulse Wave Detection System for Oriental Medicine (한방용 용적맥파 시스템)

  • Kim, H.T.;Han, S.C.;Choi, T.J.;Kim, J.K.;Huh, W.;Park, Y.B.
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.77-80
    • /
    • 2001
  • In this paper, we devised volume pulse detection system which can quantitatively represent a artery elasticity for oriental clinic. Volume pulse wave detecter system consist of transducer which has IRLED-photodiode detecter, temperature sensor and filter and preprocessing circuits, data conversion and serial communication parts, and computer system. The high-pass filter are detect volume pulse wave and lowpass filter detect tissue thickness. The detected volume pulse wave are normalized by tissue thickness value with a division process. As the result of experiment, we can detect normalized volume pulse wave with effectively.

  • PDF

A Study on Pulse Measurement of Toe Using Photoplethysmography (광전용적맥파를 이용한 발가락에서의 맥박측정에 관환 연구)

  • Jung, In-Bok;Kim, Kyung-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.07a
    • /
    • pp.353-354
    • /
    • 2013
  • 본 논문에서는 기존의 손에서 측정하는 PPG를 발가락에서 측정하여 지속적인 무자각적 측정이 가능함을 제안한다. 발가락에서의 측정은 손이 자유로워져 일상 업무에 영향을 끼치지 않으면서 고정하기 유용하기 때문에 보다 상황에 맞는 정확한 파형 검출이 가능하다. 따라서 본 논문에서는 발가락에서의 측정 가능성을 확인한 후 소형 device 제작 및 실험을 통해 손과 발에서 PPG를 측정, 비교하여 발가락에서도 PPG 파형 검출이 가능함을 보인다.

  • PDF

Individual verification method by PPG measurement (PPG 측정에 의한 개인 인증 방법)

  • Kim, Sheen-Ja;Lee, Young-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.2057-2061
    • /
    • 2008
  • Individual heartbeat has specific character by a condition of heart, structure, age, and so forth. On this paper, We propose that individual verification method using specific character of heartbeat. This character are obtained by measure PPG(Photo Plethysmogram) using LD and PD.

A study on the analysis ofPPG signal for individual verification (개인 인증을 위한 PPG 신호 분석에 관한 연구)

  • Kim, Sheen-Ja;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.438-440
    • /
    • 2009
  • 사람의 심박동은 심장 상태와 구조, 나이 등의 여러 요소에 의하여 고유한 특성을 갖고, 이러한 특성을 이용하여 개인 인증에 심박동을 적용할 수 있다. 본 논문에서는 기존의 심전도(ECG, electrocardiogram) 방법을 대신하여 빛을 이용한 광전용적맥파(PPG, Photo Plethysmogram)를 측정, 신호를 분석하였다.

  • PDF

Design of Filter to Reject Motion Artifacts of PPG Signal Using Multiwave Optical Source (다파장 광원을 이용한 광용적 맥파의 동잡음 제거 필터 설계)

  • Park, Heejung;Nam, Jaehyun;Lee, Juwon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • This study is proposed the novel PPG sensor device and the signal processing method to replace the acceleration sensor that is used to reject motion artifacts contained in photoplethysmography(PPG). The proposed method is to reject motion artifacts by an adaptive filter based on the estimated motion artifact by using a blue LED light. To evaluate the performance of the proposed method experimentally, We did design a novel sensor consisted of blue/red LEDs and photo-sensor and implemented, and then rejected the motion artifacts by using an adaptive filter and the implemented sensor. In the results of the experiments, it is shown that the proposed sensor device and signal processing can reconstruct the PPG signal despite the occurrence of motion artifacts, and also that the SNR was 4.5 times of moving average filter. According to the experimental results, the proposed method can be applied to design a low-cost device.