• 제목/요약/키워드: 용수사용량

Search Result 171, Processing Time 0.031 seconds

Estimation of Ground Water Table Using Well Data and GIS Digital Map (관정 데이터와 GIS 수치지도를 이용한 지하수면 분포 추정)

  • 이처경;문추연
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.133-139
    • /
    • 1999
  • The geostatistical method Kriging is used to estimate the areal distributions of the depth to the water table and the altitude of the water table measured from the sea level. A northern part of the city of Pohang, Kyeong-Buk, Korea has been chosen and the digital map of the area with 1:5,000 scale from the National Geographic Information System (NGIS) project by National Geographic Institute has bun used to reproduce the ground surface distribution. The water table depth appears to be in the range between 7 m and 9.5 m except a few localities where mountain tops exist and the use of groundwater for agicultural purposes is believed to be heavy. The overall distribution of the water table altitude shows a monotonic gradual decrease from the west to the east (seaward direction from the inland) and to the south with maximum rate approximately at 90 m over 6 km in horizontal distance and indicates that the groundwater is moving several meters per day there.

  • PDF

Drought Analysis Using the Low Flow Frequency and Computation Model of Maintenance Flow (갈수빈도와 정상유량산정 모델을 활용한 가뭄상황 분석)

  • Son, Kyung-Hwan;Oh, Sung-Ryul;Choi, Kyu-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.356-356
    • /
    • 2017
  • 최근 국토교통부 홍수통제소에서는 가뭄대응을 위해 1, 3개월 갈수예보를 시범적으로 운영하고 있다. 국가재난 위기경보단계(관심, 주의, 경계, 심각)에 따라 분류된 기준유량과 예측유량의 비교를 통해 갈수상황을 판단하며, 그 중 기준유량은 일본의 정상유량 산정 기법에 의해 계산된다. 그러나 우기 건기에 따라 상이한 유입량 및 물 사용량이 정상유량 산정에 고려되지 않았고, 각 위기단계별 물 부족상황이 재현되지 못하였다. 또한, 하천유량 부족은 가뭄과 관계가 밀접함에도 불구하고, 가뭄상황과의 연계분석이 이뤄지지 않았다. 본 연구에서는 갈수빈도와 정상유량산정 모델을 이용하여 기준유량을 재설정하고 가뭄상황을 분석하였다. 대상유역은 영산강유역으로 선정하였고, 보고된 하천수사용허가량, 댐 용수 공급량 및 10년 이상 장기간 관측된 관측소별 일 유량자료를 활용하였다. 일 관측유량을 7일 이동평균으로 변환한 후, 유황분석을 통해 $Q_{90}$을 산정하였으며, 빈도별 $Q_{90}$을 계산하였다. 정상유량 산정 모델에서 입력 자료(자연유량, 댐 공급량 및 하천수 허가량)에 가중치를 두어 양을 조절하고 각 빈도에 맞는 관개기 및 비관개기 기준유량을 산정 하였다. 가뭄지수로는 국내 활용성이 높은 Standardized Precipitaion Index (SPI) 및 Standardized Runoff Index (SRI)를 선정하였고, 이를 지속기간 1, 3, 6, 12개월에 따라 일별로 계산하였다. 7일 평균 관측유량이 기준유량 이하일 때, 이시점을 전 후로 가뭄지수의 시공간적 특성과 가뭄의 지속기간 및 심도를 분석하여 가뭄상황을 제시하였다. 본 연구의 결과는 갈수예보 시 하천유량 부족에 따른 물수지 및 가뭄상황에 대한 직관적인 판단과 갈수기 효율적인 하천수 조정 협의에 기여할 것으로 본다.

  • PDF

Development and Evaluation of an hourly SWAT-MODFLOW-PADDY Model Considering Characteristics of Submerged Paddy Fields in a Watershed (유역 내 담수 논 특성을 고려한 시단위 SWAT-MODFLOW-PADDY 모델 개발 및 평가)

  • Seoro Lee;Youn Shik Park;Jonggun Kim;Kyoung Jae Lim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.281-281
    • /
    • 2023
  • 최근 급격한 기후변화와 하천수 사용량의 증가로 수문학적 변동성이 증가하면서 지표수와 지하수의 통합 관리 필요성이 증대되고 있다. 이에 따라 SWAT-MODFLOW 모델은 지표수와 지하수 간의 수문학적 상호작용을 고려한 시공간적 지하수함양량의 분포와 하천과 대수층 간의 물 교환량, 장기 유출 및 수질 거동 해석 등에 널리 사용되고 있다. 그러나 이 모델은 국내 농업 유역 내 담수 논에서의 영농활동을 고려한 시단위 유출 및 수질 예측과 지표수-지하수 통합 해석에 어려움이 있다. 우리나라의 경우 전국 농지 면적 중 논이 약 50%를 차지하고 있음에도 불구하고 아직까지 국내 담수 논 특성을 고려하여 지표수-지하수 통합 해석이 가능한 수문 모델이 개발 된 바 없다. 이에 본 연구에서는 고해상도 시강우량에 따른 담수 논에서의 증발, 침투, 관개, 배수 등 모의가 가능한 Hourly SWAT-PADDY 모듈을 개발하고, SWAT-MODFLOW 모델의 수문 프로세스와의 연계를 통해 지표수-지하수 통합 해석이 가능한 Hourly SWAT-MODFLOW-PADDY 모델을 개발하였다. Hourly SWAT-MODFLOW-PADDY 모델은 사용자가 구축한 담수 논의 입력자료(담수, 관개, 낙수 일정 등)를 기준으로 논의 담수 및 비담수 시기에 따른 시단위 물수지 해석과 이를 고려한 유출량, 수질, 지하수함양량, 하천과 대수층 간의 물 교환량 산정이 가능하다. 본 연구에서 개발 된 Hourly SWAT-MODFLOW-PADDY 모델은 국내 농업 유역에서의 지표수-지하수 통합 관리 대책 수립 방향을 제시하기 위한 도구로 활용될 수 있을 것이다. 또한, 향후 논의 관개 용수 공급원 연계를 통한 모델의 고도화 방안과 최적의 논 영농 데이터베이스가 마련된다면 보다 정량적인 물수지 해석 기반의 지표수-지하수 통합 모델링이 가능할 것으로 보인다.

  • PDF

Development of Eco-Efficiency Indicators for Yeosu Industrial Park (여수산업단지의 생태효율성지표 개발에 관한 연구)

  • Kim, Jung-In;Yun, Chang-Han;Yoon, Hyung-Sun
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.229-237
    • /
    • 2010
  • The industrial ecology indicators(IEI) for Yeosu Industrial Park were developed using eco-efficiency indicator(EEI). The key factors for the creation of IEI were two parts. One part is the value of the products which is selected as the total production value, the amount of ethylene production, the amount of light oil production instead of the total sales volume for Yeosu Industrial Park, since the currency exchange and the price of raw materials varied every year. The other part is the environmental burden. The electric consumption, the industrial water consumption, and the amount of discharged waste water are all officially opened to the public, were used in the calculation. Based on the value for the year of 2004, the IEI value for 2006 became worse to 0.954, but, was expected to be 1.153, a 15% improvement, for 2015 if the current EIP project is successfully performed.

Analysis of Groundwater Use and Discharge in Water Curtain Cultivation Areas: Case Study of the Cheongweon and Chungju Areas (청원-충주지역 수막재배용 지하수 사용량 및 배출량 분석)

  • Moon, Sang-Ho;Ha, Kyoochul;Kim, Yongcheol;Yoon, Pilsun
    • The Journal of Engineering Geology
    • /
    • v.22 no.4
    • /
    • pp.387-398
    • /
    • 2012
  • Korean agricultural areas that employ water curtain cultivation (WCC) have recently suffered extensive groundwater shortages due to an increase in the number of facilities. The primary focus of this study is to measure the daily groundwater use and discharge rates in the Cheongweon and Chungju pilot areas, while the second focus is to estimate the total amount of groundwater used in WCC areas nationwide in Korea. Taking into consideration several factors, including motor type, outflow abilities of wells, records of daily minimum temperatures below $0^{\circ}C$, and the number of running wells according to weather variations, we estimated that $53,138m^3/ha$ of groundwater had been used in the 4-hectare Cheongweon pilot area during the winter period of late 2011 through early 2012. On a prorated areal basis, we can calculate that the total groundwater used nationwide was 0.57 billion $m^3$ in WCC areas of $10,746m^2$. This value is equivalent to 33.7% of the total agricultural groundwater use (1.69 billion $m^3$) in Korea. During 9-22 February 2012, the daily water discharge rate in the 4-ha Cheongweon pilot area ranged from 2,079 to $2,628m^3$, averaging $2,341m^3$. Combining this value with meteorological records for 94 days with a daily minimum temperature below $0^{\circ}C$ results in an estimated groundwater volume of $54,990m^3/ha$ for the pilot area during the 2011-2012 winter period. The total amount of groundwater used nationwide in WCC areas would then be 0.59 billion $m^3$, equivalent to 34.9% of the total agricultural groundwater use in Korea. In the Chungju area, the groundwater discharge rate was estimated to be less than 805 $m^3$/ha. This value, combined with weather data for 108 days with a daily minimum temperature below $0^{\circ}C$ in this area, can be applied to infer that the total groundwater volume used in WCC areas nationwide is no more than 55% of the total agricultural groundwater use in Korea.

A Study on Eco-efficiency in power plants using DEA Analysis (DEA 모형을 이용한 발전회사 환경효율성에 대한 연구)

  • Han, Jung-Hee
    • Journal of Digital Convergence
    • /
    • v.11 no.5
    • /
    • pp.119-133
    • /
    • 2013
  • This study aims to provide power generating plants with eco-efficiency information. To implement the purposes, of study, both DEA(Data, Envelopment Analysis) model and interview were incorporated in terms of methodologies. To analyze the managerial efficiency, total labor cost and number of employees were considered as input factors. CO2, NOx, and water also were considered as input factors to analyze eco-efficiency. Both annual total power product and annual total revenue were used as output factors. CRS(Constant Return to Scale) and VRS(Variable Return to) model were facilitated in this analysis. According to the findings, most of the power plants were evaluated as 'Efficient'' taking into consideration of average value, both 0.928 from CCR model and 0.969 from VRS model. 7 DMUs including DMU3 and DMU12 are efficient out of 35 DMUs relatively, other DMUs are inefficient. For results of inefficient output factors distribution, it was found that inefficiency for NOx was marked relatively higher than CO2. In order to improve the eco-efficiency in the power plants in the long term, the target amount of Co2 as well as NOx reduction needs to be properly proposed in consideration of particularity of power plants. In the long run, renewable energy, alternative fuels should be adapted to reduce the eco-inefficient.

Evaluation of Efficiency to Plant Growth in Horticultural Soil Applied Biochar Pellet for Soil Carbon Sequestration (토양 탄소 격리 적용을 위한 바이오차 팰렛 혼합 상토를 사용한 작물 재배 효율성 평가)

  • Shin, JoungDu;Choi, YoungSu;Choi, Eunjung;Kim, MyungSook;Heo, JeongWook
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.3
    • /
    • pp.73-78
    • /
    • 2017
  • Objective of this experiment was to evaluate efficiency of application of biochar pellet in case of application of soil carbon sequestration technology. The treatments were consisted of control as general agricultural practice method, pellet(100% pig compost), biochar pellets with mixture ratio of pig compost(9:1, 8:2, 6:4, 4:6, 2:8) for comparatives of pH, EC, $NH_4-N$ and $NO_3-N$ concentrations, and yields in the nursery bed applied biochar pellets after lettuce harvesting. The application rates of biochar pellet was 6.6g/pot regardless of their mixed rates based on recommended amount of application (330kg/10a) for lettuce cultivation. pH in the nursery bed applied different biochar pellets after lettuce harvesting was only increased in the treatment plot of pig compost pellet application, but decreased in 4:6 and 2:8 pellet application plots. However, EC was observed to be not significantly different among the treatments. $NH_4-N$ concentration was only increased in the treatment plot of pig compost pellet application, but $NO_3-N$ concentrations were decreased as compared to the control. Yields in the treatments of 9:1, 8:2 and 4:6 biochar pellet application plot were increased from 9.5% to 11.4%. Therefore, this biochar pellet application might be useful for soil carbon sequestration and greenhouse gas mitigation in the agricultural farming practices because it was appeared to be a positive effect on lettuce growth.

Unit Mass Estimation and Analysis from Fiber Dyeing and Finishing Facility Nearby Nakdong River Basin (낙동강수계에서 섬유염색 및 가공 업체에 대한 공정별 원단위산정 및 분석)

  • Gu, Jung-Eun;Nah, Dong-Hoon;Lee, Seung-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.765-774
    • /
    • 2009
  • Fiber Dyeing and Finishing facility has been recognized as an important pollution source due to its consumption of large volumes of water and chemicals. Unit mass discharge for the conventional water quality parameters such as flowrate, SS, $BOD_5,\;COD_{Mn},\;COD_{Cr}$, TN, TP were estimated. To represent the respective industries, three companies were carefully selected based on its manufacturing goods, flowrate and location at various unit operations and processes. More than 90% of decrease in unit mass estimation between influent and effluent of BOD was observed. But the values themselves were similar to those of Fiber Manufacturing facility due to the high loadings of organic matter. Biodegradability of influent was almost three times higher than that of effluent. Unit mass discharge estimations of unit process (estimated in this study) based on space, products and raw material were similar to those of composite process (estimated by National Institute of Environmental Research), while big difference was observed in the other factors. Unit mass discharge factors calculated in this study can be used as the reference for the estimation of water pollution loading costs in Nakdong river basin. For the effective water pollution control and management, it is essential to characterize the various types of water quality parameters from the effluents of individual industrial wastewater treatment plants.

Charge Neutralization of Wet-end (습부공정에 전하 중화개념의 도입)

  • 신종호;김동호;류정용;김용환;송봉근
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2001.11a
    • /
    • pp.59-59
    • /
    • 2001
  • 전보에서 발표한 바와 같이, 대상 라이너지 제조공장의 습부 운전조건이 지극히 악화되어 있으며 초지 시스템이 지종교체 등의 충격에 전혀 완충작용을 못하는 이유로 는 용수를 포함한 지료의 전하특성을 조절해주지 못하기 때문인 것으로 판단되었다. 특 히 양이온성 고분자로서 유일하게 사용하고 있는 보류향상제가 적절히 작용하지 못하 기 때문에 보류도가 저하되고, 제품내에 보류되지 못한 다량의 미세분이 백수 중에 존 재함으로서 결과적으로 지료의 전기적 특성을 더욱 악화시키는 악순환이 되풀이 되는 것으로 판단되었다. 이와 같이 강하게 음으로 하전된 지료의 전기적 특성을 조절하기 위해서는 양이온성 고분자의 사용량을 증가시키거나 고분자의 전하밀도 또는 분자량을 변화시켜 보는 것이 일반적인 습부첨가제 사용방법이라고 할 수 있다. 따라서 대상 습부공정의 조업조건을 호전시키기 위해서는 적절한 보류향상시스 템의 적용이 가장 시급한 현안이라고 판단되어 선규 보류제의 현장적용시험을 수행한 결과, 백수의 COD와 미세분이 격감하고 탈수성이 향상되어 습부공정의 운전조건이 호 전됨을 관측할 수 있었다. 그러나 2달 이상에 걸친 보류제 현장적용시험 기간 중에 생 산된 라이너지의 제반 물성들은 별다른 변화를 관측할 수 없었다. 이는 적용된 보류제 의 상당 부분이 계내의 미세분과 작용하여 소모되기 때문으로 판단되었다. 본 연구에서는 보류제의 투입 이전에 보류제와는 상대적으로 저분자량과 고 전 하밀도를 가진 고분자 전해질 4종을 사용하여 라이너지 지료의 전하를 중화시키고자 하였으며, 이러한 공정으로 생산된 라이너지의 물성변화를 관측하였다. 물성으로는 파 열강도, 압축강도, 습윤인장강도 및 염료 고착능력 등을 살펴보았다.시아노에틸화한 PYA가 안정된 분자구조를 유지하고 있음을 확인할 수 있었다. 시아노에틸화한 PYA용액의 점탄성 평가를 위하여 storage modulus와 loss modulus 를 분석하였다. 일반적 유변특성 평가 결과 PYA용액은 shear-thinning, pseudoplastic 한 특성을 나타내어 표면사이즈 공정에서의 적용 가능성을 확인할 수 있었다. 사용하는 통계기법 중의 하나인 주성분회귀분석을 실시하였다. 주성분 분석은 여러 개의 반응변수에 대하여 얻어진 다변량 자료의 다차원적인 변 수들을 축소, 요약하는 차원의 단순화와 더불어 서로 상관되어있는 반응변수들 상호간 의 복잡한 구조를 분석하는 기법이다. 본 발표에서는 공정 자료를 활용하여 인공신경망 과 주성분분석을 통해 공정 트러블의 발생에 영향 하는 인자들을 보다 현실적으로 추 정하고, 그 대책을 모색함으로써 이를 최소화할 수 있는 방안을 소개하고자 한다.금 빛 용사 둥과 같은 표면처리를 할 경우임의 소재 표면에 도금 및 용 사에 용이한 재료를 오버레이용접시킨 후 표면처리를 함으로써 보다 고품질의 표면층을 얻기위한 시도가 이루어지고 있다. 따라서 국내, 외의 오버레이 용접기술의 적용현황 및 대표적인 적용사례, 오버레이 용접기술 및 용접재료의 개발현황 둥을 중심으로 살펴봄으로서 아직 국내에서는 널리 알려지지 않은 본 기 술의 활용을 넓이고자 한다. within minimum time from beginning of the shutdown.및 12.36%, $101{\sim}200$일의 경우 12.78% 및 12.44%, 201일 이상의 경우 13.17% 및 11.30%로 201일 이상의 유기의 경우에만 대조구와 삭

  • PDF

A study on the applicability of power usage method for the analysis of river water intake (하천수 취수량 분석을 위한 전력량법의 적용성 연구)

  • Baek, Jongseok;Kim, Chiyoung;Cha, JunHo;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.12
    • /
    • pp.975-984
    • /
    • 2019
  • As an essential prerequisite for systematic and integrated management of river water, it is necessary to secure the basic data such as discharge supplied to the river and released from the river. Under the current permit system for river water use, 59.1% of licensed facilities were found to have no discharge meters in 2017, especially for agricultural water, which makes it difficult to secure reliable data as a large portion of the reports are voluntarily reported by users. In this study, the indirect discharge measurement method of calculating the discharge through the power usage of the pumping station was applied to secure reliable discharge data. In particular, focusing on the fact that the discharge calculated by the power usage method differed with the actual discharge according to the level of the river, the study was conducted on improving the power usage method reflecting the river water level and improving the accuracy of discharge data. Analysis of the discharge calculated using the power usage method considering river water level using the correlation analysis method such as regression analysis, percent difference, root mean square error etc. confirmed that the results are not high compared to the conventional power usage method, but are slightly more approximated to the actual discharge. Therefore, although reliable discharge data can be obtained from the existing power usage method, it is expected that more accurate data on intaking water of river water can be obtained if the improved power usage method is used at points where the variation in the water level of the river is large.