• 제목/요약/키워드: 용량 선정

Search Result 529, Processing Time 0.033 seconds

Integrated Optimal Design of Hybrid Structural Control System using Multi-Stage Goal Programming Technique (다단계 목표계획법을 이용한 복합구조제어시스템의 통합최적설계)

  • 박관순;고현무;옥승용
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.5
    • /
    • pp.93-102
    • /
    • 2003
  • An optimal design method for hybrid structural control system of building structures subject to earthquake excitation is presented in this paper. Designing a hybrid structural control system may be defined as a process that optimizes the capacities and configuration of passive and active control systems as well as structural members. The optimal design proceeds by formulating the optimization problem via a multi-stage goal programming technique and, then, by finding reasonable solution to the optimization problem by means of a goal-updating genetic algorithm. In the multi-stage goal programming, design targets(or goals) are at first selected too correspond too several stages and the objective function is th n defined as the sum of the normalized distances between these design goals and each of the physical values, that is, the inter-story drifts and the capacities of the control system. Finally, the goal-updating genetic algorithm searches for optimal solutions satisfying each stage of design goals and, if a solution exists, the levels of design goals are consecutively updated to approach the global optimal solution closest too the higher level of desired goals. The process of the integrated optimization design is illustrated by a numerical simulation of a nine-story building structure subject to earthquake excitation. The effectiveness of the proposed method is demonstrated by comparing the optimally designed results with those of a hybrid structural control system where structural members, passive and active control systems are uniformly distributed.

A Convergence Study on the Association between Alcohol Consumption and Periodontal disease (음주와 치주질환간의 관련성에 관한 융합연구)

  • Kim, Ji Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.8
    • /
    • pp.95-100
    • /
    • 2018
  • The Korea Convergence Society. The aim of this study was to evaluate the association between alcohol consumption and periodontal diseases in Korea adults. The date from the 2014 Korean National Health and Nutrition Survey were used, and 4,328 subjects over 30 years were included in the analysis. Periodontal disease was assessed using the Community Periodontal Index. The adjusted odds ratio of drinking experience, drinking frequency, the drinking amount and the drinking duration were calculated from the logistic regression model with the never-drinkers as a reference group and the logistic model controlled for age, gender, education, and diabetes. This study found that the risk of periodontal disease according to the drinking status of adults over 30 years of age was 1.39 times (95% CI=1.01-1.90) higher than that of non-drinking group when the number of drinks consumed at one time was more than seven glasses. The frequency of binge alcohol consumption, amount of alcohol consumption and duration of alcohol consumption were significantly associated with the risk of periodontal disease in a dose-response pattern among over 30 years. Alcohol consumption was discovered to be a potential risk indicator for periodontitis. Dental practitioners need to be aware that patients who drink may be at higher risk of periodontitis and could benefit from advice to quit drinking and maintain regular dental visits.

A Study of Traffic Signal Progression on a CBD for Reducing Traffic Signal Cycle as Expansion of Permissive Left-Turn (비보호좌회전 확대에 따른 주기감소가 도심연동체계에 미치는 영향 연구)

  • Jung, Jin-Hyoung;Kwon, Young-Suk;Choi, Ki-Joon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.559-565
    • /
    • 2016
  • For the purpose of the research, it is analyze the influence traffic Signal Progression on a CBD by expansion of Permissive Left-Turn on the advanced traffic management system program compared with traffic response control For this, divided a average distance between intersections, a traffic network on five district in four city. As the result, Volume of the traffic management system on a advanced traffic management system program compared with traffic response control is effective in traffic signal cycle 160sec 286car per lane, in 140sec 308car, 120sec 264car. As well, for a traffic network as the length of a traffic network 2.0~3.0km, under 2.0km, all of traffic signal cycle(160sec, 140sec, 120sec) a passing band and stop is more effective. But the traffic management system on traffic response control compared with the traffic management system on a advanced traffic management system program is effective in the length of a traffic network over 5.0km. For the efficiency of traffic signal system manage, it should be runned the traffic management system on traffic response control in addition to the traffic management system on a advanced traffic management system program on CBD. As the result of simulation the business in chungju-si, the travel speed of the traffic management system on a advanced traffic management system program is 41.2km/h and the travel speed of traffic response control is 37.5km/h. Therefore, it should be runned per length of a traffic network the traffic management system on traffic response control in addition to the traffic management system on a advanced traffic management system program on CBD.

Intravenous Iron Supplementation in Korean Children on Chronic Dialysis (한국 만성 투석 소아 환자에서 정맥용 철분 제제 투여에 관한 연구)

  • Cho, Hee-Yeon;Hahn, Hye-Won;Ha, Il-Soo;Cheong, Hae-Il;Choi, Yong
    • Childhood Kidney Diseases
    • /
    • v.13 no.2
    • /
    • pp.197-206
    • /
    • 2009
  • Purpose : Limited information is available on experiences of intravenous iron treatment in children. In this study, iron sucrose was administered intravenously to determine its effect, the factors predicting outcome, and safety in children on chronic dialysis. Methods : Twenty-one children whose serum ferritin levels were less than 100 ng/mL or transferrin saturations (TSAT) were less than 20% were enrolled. In 12 children on peritoneal dialysis (PD), the drug was infused intravenously as 200 mg/$m^2$ ($\leq$200 mg) at week 0, 2, 4, and 6. In 9 children on hemodialysis (HD), it was given intravenously as 8 weekly doses of 3 mg/kg ($\leq$100 mg) through week 0-7. Results : After treatment, serum ferritin levels increased significantly in both groups, and TSAT rose significantly in PD group. However, hemoglobin level did not rise significantly in both groups. Children with baseline hemoglobin less than 10 g/dL or baseline TSAT less than 20% showed significantly higher rise of hemoglobin after intravenous iron treatment. To the contrary, those with higher baseline hemoglobin and TSAT levels displayed higher rise in serum ferritin after the treatment. Although no serious adverse event occurred, TSAT levels exceeding 50% were noted in 6 patients in PD group. Conclusion : This suggests that 3 mg/kg/week of intravenous iron sucrose can be used safely in children on chronic HD, but 200 mg/$m^2$ every other week may incur excessive TSAT level in some patients on chronic PD.

A Study on Ventilation System of Underground Low-Intermediate Radioactive Waste Repository (지하 동굴식 중-저준위 방사성 폐기물 처분장의 환기시스템 고찰)

  • Kim, Young-Min;Kwon, O-Sang;Yoon, Chan-Hoon;Kwon, Sang-Ki;Kim, Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.65-78
    • /
    • 2007
  • The pollutants (Rn, CH, CO, HS, radioactive gas from radiolysis) were generated from the process of construction and operation of underground repository, and after disposal of low-intermediate radioactive waste inside there must be controlled by a ventilation system to distribute them in area where enough air is supported. Therefore, a suitable technical approach is needed especially at an underground repository that is equipped with many entry tunnels, storage tunnels, exhaust-blowing tunnels, and vertical shafts in complicated network form. For the technical approach of such a ventilation system, WIPP (Waste Isolation Pilot Plant) in U. S and SFR (Slutforvar for Reaktorafall) low-intermediate radioactive waste repository in Sweden were selected as the models, for calculating the required air quantity, organizing a ventilation network considering cross section, length, surface roughness of the air passage, and describing a calculation of resistance of each circuit. Based on these procedures, a best suited ventilation system was completed with designing proper capacity of fans and operating plan of vertical shafts. As a result of comparing the two repositories based on the geometry dimensions and ventilation facility equipment operation, more parallel circuit as in WIPP, brought decrease in resistance for entire system leading to reduce of operating costs, and the larger cross-sectional area of the SFR, the greater the percentage of disposal capacity. Accordingly, the mixture of parallel circuit of WIPP repository for reducing resistance and SFR repository formation for enlargement of disposal capacity would be the most rational and efficient ventilation system.

  • PDF

Effect of Application of Woody Chared Materials on the Plant Growth and the Chemical Properties of Soil in the Continuous Cropping Field of Red Pepper (고추 연작지(連作地)에 있어서 목질탄화물(木質炭化物) 시용(施用)이 생육(生育) 및 토양(土壤)의 화학성(化學性)에 미치는 효과(效果))

  • Park, Sang-Keun;Kim, Kwang-Yong;Lee, Ji-Weon;Shin, Young-An;Lee, Eung-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 1993
  • This study was conducted to investigate the effect of woody chared materials on the injuries and growth of plant, and chemical properties of soil in the continuous cropping field of red pepper. The field for the experiment was selected among districts, where have been taking place seriously injuries by continuous cropping of red pepper for above 20 years. The growth of red pepper was promoted and the growing period was prolonged about 2 weeks longer than that of control, and yield was increased with the increment of charcoal application amount. The occurrance rate of phytopthora blight disease was 9% lower at charcoal 500 kg/l0a application treatment than at control in the experiment of application amount of the first year, but was not significantly different between sizes of charcoal. The mix of charcoal and pyroligeous liquor had no effect on the growth of red pepper. In applicated soil of charcoal, pH was increased, EC was decreased, and Ca and Mg content was low somewhat. In all, charcoal granule was most effective type. The B/F value of soil was higher at the charcoal powder treatment on July 18 than other treatment, but was no difference between treatments in anytime else.

  • PDF

A Study on the Difference in Ballasting Time Arising from the Installation of an Ultraviolet Ballast Water Management System on Existing Ships (현존선에 자외선 평형수처리장치 설치로 인한 평형수 처리시간 변화에 관한 연구)

  • Seo, Kil-Cheon;Lee, Kyoung-Woo;Rho, Beom-Seok;Cho, Ik-Soon;Lee, Won-Ju;Pham, Van Chien;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.576-585
    • /
    • 2020
  • This study quantitatively investigated the increase in ballasting time through numerical calculations when an ultraviolet (UV) ballast water management system (BWMS) is installed on an existing vessel. The calculation results indicate that the ballasting time of a gas carrier having 55,000 dead weight tonnage was 2.152 hours without installation of the UV BWMS and implementation of a flow control function. Ballasting time increased by 14.2% after installing the UV BWMS, and it increased by 20.4% with both its installation and implementation of a flow control function. If actual conditions are taken into account, ballasting time after installing the UV BWMS is estimated to increase by at least 30% compared with current ballasting time. Therefore, when concerned parties select a UV type BWMS, it is advisable for them to minimize ship operation losses from an increase in ballasting time by considering the capacity of the actual ballast pumps on board and the flow energy loss of the UV BWMS. Additionally, it is recommended that a BWMS with larger capacity, larger pipes, and pipes with inside coatings be used to minimize the increase in ballasting time after installation of the BWMS.

An Optimal Location of Superconducting Fault Current Limiter in Distribution Network with Distributed Generation Using an Index of Distribution Reliability Sensitivity (신뢰도 민감도 지수를 이용한 복합배전계통 내 초전도한류기의 최적 위치에 관한 연구)

  • Kim, Sung-Yul;Kim, Wook-Won;Bae, In-Su;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.52-59
    • /
    • 2010
  • As electric power demand of customers is constantly increasing, more bulk power systems are needed to install in a network. By development of renewable energies and high-efficient facilities and deregulated electricity market, moreover, the amount of distributed resource is considerably increasing in distribution network consequently. Also, distribution network has become more and more complex as mesh network to improve the distribution system reliability and increase the flexibility and agility of network operation. These changes make fault current increase. Therefore, the fault current will exceed a circuit breaker capacity. In order to solve this problem, replacing breaker, changing operation mode of system and rectifying transformer parameters can be taken into account. The SFCL(Superconducting Fault Current Limiter) is one of the most promising power apparatus. This paper proposes a methodology for on optimal location of SFCL. This place is defined as considering the decrement of fault current by component type and the increment of reliability by customer type according to an location of SFCL in a distribution network connected with DG(Distributed Generation). With case studies on method of determining optimal location for SFCL applied to a radial network and a mesh network respectively, we proved that the proposed method is feasible.

A Study on Critical Speed Enhancement of High-speed Train Passenger Car (고속열차 객차의 임계속도 향상에 관한 연구)

  • Jeon, Chang-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.603-610
    • /
    • 2016
  • Over 12 years have passed since the first commercial operation of a Korean high-speed train. Since then, the transport capacity of the high-speed lines has become almost saturated. Therefore, studies have been carried out to increase the operating speed of the trains in order to increase their transportation capacity. This study was carried out to improve the critical speed of the KTX-Sancheon, Korean high-speed train, in order to increase its operating speed. A dynamic analysis of the KTX-Sancheon train was performed using the contact data obtained from the wheel wear profiles that were measured from a KTX-Sancheon train in commercial operation. The analysis results were verified by comparing them with the measurement acceleration data obtained from KTX-Sancheon. The suspension parameters were optimized to improve the operation speed. The critical speed of KTX-Sancheon was increased by 9.4% after the optimization by the response surface method. The optimized suspension parameters are expected to be used for the new bogie design to increase the operating speed of KTX-Sancheon from 300km/h to 350km/h.

An Experimental Study on the Application of Measuring Method of Water Content for Quality Control of Concrete (콘크리트 품질관리를 위한 단위수량 측정 기법의 적용성에 관한 실험적 연구)

  • Kim, Yong-Ro;Choi, Il-Ho;Jung, Yang-Hee;Lee, Do-Bum
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.179-188
    • /
    • 2007
  • Recently, the concern on the receipt of poor ready-mixed concrete in the construction field and the durability of concrete has been increased. Based on the such background, a large number of measuring methods of water content for fresh concrete have been developed and enforced in a developed country. In this study, to investigate practicality for quality control of ready-mixed concrete among various water content measurement techniques, microwave range method, air meter method and capacitance measurement method as measuring methods of water content were selected. Then, it was evaluated estimating performance of water content according to the change of binder types, fine aggregate types, absorption ratio, water content and water-binder ratio in series I and II. Also, it was examined influence on error occurrence of water content according to change of properties of used materials in series III. Finally, based on this study, it was proposed fundamental data to utilize measurement technique of water content to quality control of ready-mixed concrete in construction field.