• Title/Summary/Keyword: 용량성 부하

Search Result 566, Processing Time 0.031 seconds

Evaluation for Lifetime and Thermal Ratings for Aged Overhead Transmission Lines (노후 가공송전선의 수명과 열용량의 평가)

  • Kim, Sung-Duck
    • Journal of IKEEE
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Thermal rating or lifetime evaluation for aged overhead transmission line becomes more important concerns with respect to keeping power delivery stable having proper capability. Both load rating and dip/clearance are essential factors to determine transmission capacity. In order to evaluate thermal rating and conductor lifetime for domestic transmission lines with double-circuit, the dip/ground clearance standards as well as the electrical equipment technical standard are examined. Conductor temperature and dip are calculated under the assumption of a contingency, and then, a method to up-rate load capacity is searched. As thermal rating and limit dip for aged conductor are properly evaluated, an improved strategy in order to guarantee the existing power system reliability is presented in this paper.

Capacity of Convergence System of Broadcasting and Communications in Correlated Nakagami Fading Channel (상관도를 갖는 Nakagami 페이딩 전송로에서의 방송통신융합시스템의 용량)

  • Kim, Joo-Chan;Kim, Yo-Cheol;Kim, Jin-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3481-3485
    • /
    • 2010
  • In this paper, we propose a concept and model of an additional service system as a kind of convergence system of broadcast and telecommunication. The proposed system use existing back-bone network such as broadcasting or communication networks. For this, we derive channel capacity formula as an approximated closed-form expression in order to show how many reliable additional data can be transmitted through wireless fading channel. From the derived formula, we confirm that the channel capacity is varied according to channel and system parameters.

A case study on the increasing load capacity of AT Feeder system with speed-up train (고속열차 투입에 따른 AT급전계통의 부하용량증가에 관한 사례연구)

  • Na, Youn-Il;Han, Seong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.694-698
    • /
    • 2005
  • The operation speed improvement of the train in electric railway must pursue continuously and need the investigation of whole railway system whole. The high-speed of the train is related to not only vehicle technique but also the infrastructure, signal system, operation technique, the trolley line and catenary, economical efficiency. Specially, in case of electric railway, we have to consider a technical investigation which is current collection efficiency improvement, voltage drop countermeasure, equipment capacity, track force, signal system. In this paper, we presents the technical investigation of AT feeder system in order to achieve high speed train in exist real railroad. We proved this approach which will use the whole domestic lines in the future.

  • PDF

Safety Performance Evaluation of Technical Independence 5kW Class Fuel Cell System (기술자립형 5kW급 건물용 연료전지시스템 안전성능 평가)

  • Lee, Jungwoon;Kim, Younggyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.82.1-82.1
    • /
    • 2011
  • 최근 국내에서 발생된 대규모 정전사태로 인해 안정적인 전력공급에 대한 국민들의 요구가 커져, 지난 3월 일본 후쿠시마 원전사고 이후 다시 한번 분산전원에 대한 필요성이 대두되어지고 있다. 여러 분산전원 중 연료전지는 다른 에너지원에 비해 에너지의 지속성이 우수하여 가장 안정적인 분산전원 형태의 하나이다. 이에 따라 국내의 경우 우수한 도시가스 인프라로 인해 건물용 연료전지라는 신기술에 대한 국민의 수용성은 점점 높아질 것으로 기대된다. 현재 건물용 연료전지의 경우, 주로 1kW급 연료전지가 시범보급되어 각 가정에 설치되어지고 있으나, 상가, 주유소 및 편의점 등의 상업시설과 생활관 및 소형빌라 등의 집단 주거시설 같은 1kW급 보다 용량을 더 필요로 하는 응용처에 국내에서 개발된 5kW급 연료전지시스템이 적용되어지기를 기대한다. 본 연구에서는 국내 제작된 5kW급 고분자전해질 연료전지시스템의 보급이전에 안전성능 평가를 통해 시스템의 성능 및 안전성 평가결과를 제조사에 피드백 하여 5kW급 건물용 연료전지시스템의 조기 상업화에 앞장서고자 한다. 5kW급 연료전지시스템의 기술개발은 핵심부품인 연료변환기, 스택 및 BOP 기술의 경우 1kW급 연료전지시스템에 적용된 것과는 다른 기술이 필요하고, 단순한 scale-up 과정이 아닌 새로운 기술개발로 제품에 적용시켜야 하는 난점을 가지고 있다. 특히, 연료변환기의 경우 연료 유량의 증가로 인하여 reformer, CO shift 및 Prox 반응기의 유체역학, 열교환 흐름 및 촉매반응 공학적으로 이론을 응용한 새로운 반응기 설계와 제작기술 확립이 선행되어 전체적인 시스템 제작 설계에 반영되어져야 한다. 그러므로 본 연구에서는 연료전지시스템 안전성능 평가를 위해 용량증대에 따른 안전성평가 항목을 검토하고, 5kW급 연료전지시스템평가를 수행하여 시스템의 제품성능, 작동성능 및 계통연계성능에서의 안전성을 확인하였고, 정전 유풍과 같은 이상조건 및 실외 환경에 대한 시스템의 안전성도 확인하였다. 또한 부하운전 조건을 75% 및 50%로 변화시켰을 때 빠른 응답시간과 안정적인 부하변동운전을 확인하였다.

  • PDF

Optimization Power Management System for electric propulsion system (전기추진시스템용 OPMS 기법 연구)

  • Lee, Jong-Hak;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.8
    • /
    • pp.923-929
    • /
    • 2019
  • The stability of the propulsion system is crucial for the autonomous vessel. Multiple power generation and propulsion systems should be provided for the stability of the propulsion system. High power generation capacity is calculated for stability, resulting in economical decline due to low load operation. To solve this problem, we need to optimize the power system. In this paper, an OPMS for electric propulsion ship is constructed. The OPMS consists of a hybrid power generation system, an energy storage system, and a control load system. The power generation system consists of a dual fuel engine, the energy storage system is a battery, and the control load system consists of the propulsion load, continuous load, intermittent load, cargo part load and deck machine load. The power system was constructed by modeling the characteristics of each system. For the experiment, a scenario based on ship operation was prepared and the stability and economical efficiency were compared with existing electric propulsion ships.

Analysis of Size and Economic Sensitivities according to Changes in Component Replacing Costs of Renewable Hybrid Generation System (신재생복합발전시스템의 각 구성품 교체비용변화에 따른 용량 및 경제성 민감도 분석)

  • Lim, Jong Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.71-78
    • /
    • 2015
  • This paper presents a method for analyzing the size and economic sensitivity of a new renewable hybrid generation system according to changes in the component replacement costs based on HOMER (Hybrid Optimization Model for Electric Renewables). The design of a hybrid system can be optimized by reducing the size of a sensitive component based on sensitivity analysis using the change in cost of a component. Sensitivity analysis can also provide information on what combinations are necessary for the optimal hybrid system. As an example, sensitivity analysis was performed on the residential load provided by HOMER, and the effects of component replacement costs on the system size and cost were quantitatively analyzed.

The Method of Deciding Design Level of Service with Optimal User Cost (사용자비용최적화를 통한 도로 설계서비스수준 산정방안)

  • 장재남;이용택;김호덕;장명순
    • Journal of Korean Society of Transportation
    • /
    • v.18 no.2
    • /
    • pp.17-26
    • /
    • 2000
  • LOS(Level of Service), the qualitative measure describing operational condition of highway, must be evaluated as quantative index in terms of user service. So, This study is focused on developing the user cost function that user cost is measured in the variation of V/C, MOE(Measure of Effectiveness) of LOS in basic Section of highway. The user cost is calculated as the sum of accident cost, operation cost, travel time cost. The data is collected in the four basic section of Singal-Ansan and Jung bu Highway. As the result of user cost function analysis, the user cost is the lowest When V/C is 0.54. Considering the V/C ratio(0.7) of Basic Section in rural highway suggested in KHCM, We find out that the LOS suggested KHCM increase the user cost of highway.

  • PDF

Development of Realtime River Water Use Monitering System by Image (영상을 이용한 실시간 하천수 사용량 수집시스템 개발)

  • Kim, Chi-Young;Won, Yoo-Seung;Cha, Jun-Ho;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1843-1847
    • /
    • 2008
  • 국토해양부는 수자원 상황을 효율적으로 모니터링하기 위하여 하천수 관리자, 하천수 사용자 및 일반 국민에게 하천유량, 사용량 및 기타 수문정보를 실시간으로 제공할 수 있는 모니터링 시스템을 시범 구축하였다. 향후 유역 물수지, 하천갈수상황을 분석할 수 있는 시스템을 추가하여 전국의 하천유량을 실시간으로 모니터링하고 관리하기 위하여 실시간 물관리시스템 구축을 추진 중에 있다. 구축된 실시간 물관리 시스템의 효율적 운영을 위해서는 하천 유량 등 수문정보와 더불어 하천 취수량 정보가 필수적이다. 본 연구에서는 실시간 물관리의 핵심자료인 하천수사용량을 실시간 수집할 수 있는 "영상을 이용한 실시간 하천수사용량 수집시스템"을 개발하였다. 개발된 시스템은 유량계 혹은 전력량계를 통해 표출되는 관련정보를 CCTV 카메라로 촬영하여 영상을 취득하고, 문자인식 알고리즘을 활용 수치로 변환하여 사용량을 제공해 주는 시스템이다. 관리자는 영상을 촬영한 후 문자로 인식된 사용량 주서버에 전송하여 저장하기 때문에 사용량과 함께 현장상황을 확인할 수 있다. 개발한 시스템은 다양한 형태의 유량계, 전력량계로 구성되어 있는 계측시설에 대해 적용이 용이하고, 기존 유량계 등을 그대로 활용하여 자료를 수집할 수 있기 때문에 저비용으로 하천수사용량 자료를 수집 관리할 수 있다. 현재 국토해양부에서는 "하천법"에 근거하여 용도별 일정규모이상의 하천수사용자에 대해 일사용량을 월별로 수집하고 있으나, 자발적인 선사용 후보고 체계로 객관성확보가 어렵고 실시간 물관리를 위한 자료로 활용이 곤란한 상황이다. 그러나, 본 시스템을 통해 하천수사용량을 수집할 경우 실시간으로 수치화된 사용량과 영상자료가 전송되어 서버에 저장할 수 있어 객관성을 확보하고 활용도를 높일 수 있는 장점이 있다. 본 시스템은 한강 홍수통제소 관할 허가지점에 3개소, 금강 관할 허가지점에 1개소에 시험적용하여 평가한 결과, 저비용으로 하천수 취수량을 효과적으로 수집할 수 있는 것으로 평가되었다.

  • PDF

Load torque compensaiton algorithm for single rotray compressor of air conditioning system (Single rotary compressor의 저진동 저속제어를 위한 자동 부하 보상 알고리즘)

  • Gu, Bon-Gwan;Choi, Jun-Hyuk;Jung, In-Soung
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.320-322
    • /
    • 2010
  • 저용량 에어컨의 압축기에 많이 사용되는 Single rotary 방식은 하나의 피스톤만을 채용하여 가격적인 면에서 큰 이점을 가진다. 그러나, 압축기 모터가 1회전할때 마다 압축과 토출을 단 1회 거치게 되므로, 부하변동을 심하여 진동이 많이 발생하는 단점이 있다. 이러한 단점을 보완하기 위하여 Single rotary를 사용하는 에어컨 제품에서는 저속에서의 운전을 회피하거나 하나의 운전점에 대한 전향보상기를 채용하여 진동을 저감시켜 왔다. 본 논문에서는 모든 운전점에서 보상이 가능하도록 압축과 토출로 인한 부하의 패턴에서 각 주파수 성분을 분석하여 자동으로 부하 토크를 보상하는 알고리즘을 제안한다. 제안된 방법은 가장 영향이 큰 1차와 2차 주파수 성분의 속도 리플의 양을 FFT 하고, 그 양이 작아지는 방향으로 부하 토크를 전향 제어방식으로 인가하는 방식이다. 제안된 방식을 이용하여 저속 운전에서 진동이 저감 되는것을 실험을 통하여 보였다.

  • PDF

Optimum Design of the Ground-Coupled Heat Pump Systems according to Heat Pump Unit Performance (열펌프 유닛 성능과 지열원 냉난방 시스템 설계에 관한 연구)

  • Kim, Namtae;Cho, Chanyong;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.193-193
    • /
    • 2011
  • 현재까지 대부분의 지열원 열펌프 시스템에 관한 연구는 열펌프 유닛과 지중열교환기에 대해 개별적으로 수행되었으며, 열펌프 유닛과 지중열교환기 설계 및 최적화의 공통변수인 지중순환수 유량에 따른 시스템 전체에 대한 연구성과는 매우 미미한 실정이다. 본 연구에서는 현재 국내에서 인증되어 보급되고 있는 물매물 지열원 열펌프 유닛의 성능 자료를 분석하고, 지중순환수 유량 변화에 따른 물대물 열펌프 유닛의 성능 실험 및 지중열교환기 형상에 관한 설계 및 분석을 수행하여 지열원 열펌프 시스템 최적화에 관한 기반 기술 확보하고자 하였다. 현재 국내의 물대물 지열원 열펌프 유닛의 냉방 및 난방 조건에서의 최소 인증 COP는 각각 4.1과 3.45이다. 다양한 용량 및 성능을 갖는 국내 인증 물대물 지열원 열펌프 유닛에 대한 정량적 성능 분석을 위하여 3.5kW(1RT) 용량당의 지중순환수 유량과 COP를 고찰하였다. 냉방운전시 3.5kW 단위 용량당 열펌프 유닛의 지중순환수 유량은 10.73에서 18.52LPM을 나타냈으며, 난방운전에는 10.41에서 18.16LPM을 나타냈다. 이때, 냉방 COP는 4.1에서 5.4의 값을 나타냈으며, 난방 COP는 각각 3.5에서 4.2를 나타냈다. 인증 열펌프 유닛에서 지중순환수 유량과 열펌프 유닛의 냉난방 성능은 일정한 경향성을 나타내지 않았다. 지중순환수 유량에 따른 지열원 열펌프 유닛과 시스템의 성능을 정량적으로 분석하고자 지중순환수 유량 변화에 따른 물대물 지열원 열펌프 유닛 성능 실험을 수행하고 이를 기반으로 지중열교환기를 설계 및 분석하였다. 냉난방 각 운전모드에서 ISO 13256-2 규격과 NRGT 101 규격을 기준으로 지중순환수와 부하측 유량 6LPM 에서 36LPM 사이에서 변화시키며 성능 실험을 수행하였다. 냉방 및 난방모드 모두 유량이 증가함에 따라 열펌프 유닛 COP가 증가하였으나, 유량 증가에 따른 열펌프 유닛 COP 증가율은 감소하였다. 지중순환수 유량이 18LPM 이상에서는 COP 상승폭은 미소하였다. 기존문헌의 부하 산정자료와 열펌프 유닛 실험 성능 데이터를 이용하여 지식경제부 고시 2009-332호에 준하여 수직밀폐형 지중열교환기를 설계하고 순환펌프 소요동력을 이용하여 시스템 COP를 분석하였다. 지중열교환기 설계 시 국내에서 가장 많이 사용되고 있는 상용지중열교환기 설계프로그램인 GLD 프로그램을 사용하였다. 지중순환수와 부하측 2차 유체 유량 증가 시에 열펌프 유닛 COP 증가율 대비 시스템 COP 증가율은 감소하였으며, 난방모드에서는 일정 유량 이상에서는 열펌프 유닛 COP는 증가하였으나, 시스템 COP는 감소하였다. 또한, 지중순환수 유량 증가에 따라 지중열교환기 길이가 증가하였으며, 냉난방시의 지중열교환기 길이차이가 증가하였다. 지열원 열펌프 시스템의 고효율화 및 시공비 절감을 통한 경제성 확보를 위해서는 지열원 열펌프 유닛 성능과 지중열교환기 형상 공통 변수인 지중순환수 유량을 함께 고려하여 시스템을 설계하여야한다.

  • PDF