• Title/Summary/Keyword: 요골 원위부 골절

Search Result 9, Processing Time 0.027 seconds

Acute Rupture of Extensor Pollicis Longus Tendon after Distal Radius Fracture: A Case Report (요골 원위부 골절 후 발생한 급성 장무지 신전건 파열 -1예 보고-)

  • Hwang, Jung Chul;Chung, Duke Whan
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.24-27
    • /
    • 2011
  • Late rupture of the extensor pollicis longus (EPL) tendon is an occasional complication following a distal radius fracture. Early rupture of the EPL tendon as a complication of distal radius fracture is rare. We report one case of early rupture of the EPL tendon after distal radius fracture.

  • PDF

Risk Factors in Stability after Immobilization of the Distal Radius in Unstable Fractures in Children (소아 요골 원위부 불안정 골절의 캐스트 후 안정성에 영향을 미치는 요소)

  • Shin, Yong-Woon;Sohn, Jong Min;Park, Sang-Yoon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.215-223
    • /
    • 2021
  • Purpose: Distal radius fractures in youth are treated conservatively in most cases, but there are some cases of redisplacement in the follow-up period after cast immobilization, even after complete reduction. This study examined the risk factors of redisplacement in reduced unstable distal radius fractures. Materials and Methods: From February 2011 to June 2018, 44 unstable distal radius fractures were managed with a closed reduction and cast immobilization. The patients were aged between 6 and 14 years. The cases of redisplacement were analyzed with the fracture characteristics (fracture obliquity, fracture level ratio, ulnar fracture combined), cast qualities (gap index, cast index, 3 point index, and radius-2nd metacarpal angle) and host factors (age, sex). Results: The mean angulation in the union was 9.2° (0°-32.8°). In the categorical grouping 29 cases were within 10° angulation, and 15 cases were more than 10°. No significant differences in the factors of the cast indices or host factors were noted. The meaningful factor was the fracture level calculated by the relative width of the fracture site divided by the sum of width of diaphysis and epiphysis (p=0.001) and combined ulnar fracture (p=0.019). Conclusion: Unstable distal radius fractures should be treated with more stubborn guidelines lest the fracture loses its anatomical alignment. In particular, in patients with less remodeling power, operative treatment would secure a better result if the fracture occurs in a more proximal location.

The Tangential Projection Method for Checking Existence and Nonexistence of Radius Groove Penetration of Screw after Distal Radius Fracture Operation Used the T-type Plate (T형 금속판을 이용한 요골 원위부 골절 수술 후 나사못의 요골구 관통 유무를 확인하기 위한 접선방향 촬영법)

  • Seo, Sun-Youl;Hong, Ki-Jang;Han, Man-Seok;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.335-340
    • /
    • 2010
  • This paper is about a projection method to check existence of radius groove penetration of screw after distal radius fracture operation using the T-type plate. Angle of Radius groove was analyzed by fifty one CT images that contains patients' wrist and twenty cases of radius specimens. After making radius phantom by plaster, we set the screw so that it penetrated 2.4 mm depth of radius groove. Then, we projected the phantom by X-ray in change of the elevation and supination angle of distal radius by 5 degree interval on 0~30 degree. The average value of groove angle in the wrist CT images was 14.4 degree and the radius specimens was 16.3 degree. Screws penetrating radius groove of the phantom have different lengths according to elevation angle and supination angle. Consequently, in order to confirm existence and nonexistence of radius groove penetration of the screw in tangential projection after distal radius fracture operation using the T-type plate, we recommend 5 degree of elevation angle and 20 degree of supination angle.

Comparison of Three Surgical Method Outcomes for Dorsal Communition Distal Radial Fractures: External Fixation, External Fixation with Allogenous Bone Graft (DBM) and Volar Locking Plate Fixation (배측 분쇄가 있는 원위부 요골 관절내 골절의 3가지 수술적 치료 결과 비교: 외고정 기구 단독, 외고정 기구와 동종골이식 및 수장측 잠김 압박 금속판)

  • Choi, Joon-Cheol;Na, Hwa-Yeop;Lee, Young-Sang;Kim, Woo-Sung;Oh, Kyung-Soo;Song, Woo-Suk;Kim, Se-Jun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.115-120
    • /
    • 2009
  • Purpose: To evaluate the outcomes of three different surgical approaches in treating a distal radius fracture with dorsal communition. Materials and Methods: From April, 2006 to May, 2009, 49 patients over age of 60years old with unstable dorsal communition distal radius fracture were analyzed. We compared maintainability of reduction by radiological follow-up observations and clinical outcomes using Mayo wrist scores. One-Way ANOVA test was performed to examine the statistical correlation between the methods. Results: All three approaches provided satisfactory post-op reduction results. However, follow-up observations showed significant loss of reduction in the external fixation only group compared to the added bone graft group and the volar anatomical locking plate group (P<0.05). Mayo wrist score was indifferent between the three groups. Conclusion: Treatment of a distal radius fracture with severe dorsal communition using an external fixation only appears to be insufficient in maintaining reduction of a cancellous bone defect.

  • PDF

Clinical and Radiological Results of Treating Unstable Distal Radial Fractures with a Domestically Developed Volar Locking Plate That Has the Characteristic of Double-Tiered Subchondral Support (불안정성 원위 요골 골절의 치료에 있어 한국형 이중 연골하지지고정 전방 금속판의 임상적 및 방사선학적 결과)

  • Lee, Chul-Hyung;Jung, Deukhee;An, Chung-Han;Jeong, Uitak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.495-502
    • /
    • 2020
  • Purpose: The aim of this study was to assess the effectiveness of domestically developed volar locking plate which has the concept of double-tiered subchondral support (DSS) in maintaining the reduction after distal radial fracture surgery. Materials and Methods: From July 2017 to December 2018, 54 patients were assessed. Plain radiographs were obtained immediately after surgery and at the last follow-up, and the radiographic parameters were measured in those images: radial length, radial inclination, volar tilt, ulnar variance, and distal dorsal cortical distance. The patients were subdivided into their age, type of fracture, and the position of the plate to evaluate the influence of each factors on the reduction maintenance. Results: Distal dorsal cortical distance in radiographs after the surgery was 5.91 mm (standard deviation, ±1.95 mm) on average. Significant differences in the radial length (p=0.038) and ulnar variance (p=0.001) were observed between immediately after surgery and at the last follow-up. When the parameters were evaluated by dividing the patients into subgroups according to the three specific factors, the ulnar variance showed a significant increase at the last follow-up when the patients were included 65-years-old or older. AO/OTA type C3 fracture, and Soong classification grade 0 plate position (p=0.007, p=0.012, p=0.046, respectively). Conclusion: Using the domestically developed DSS-type volar locking plate, significant reduction after distal radial fracture surgery could be maintained successfully. On the other hand, further study will be needed to determine about the reduction loss of the lunate facet identified in special cases that deal with fractures in elderly patients, unstable AO/OTA type C3 distal radial fractures, and Soong classification grade 0 plate position.

The Clinical usefulness of the tangential projection view of Radius groove after Distal Radius Fracture operation using the T-type Plat (전방 잠금형 금속판을 이용한 요골 원위부 골절수술 후 요골구 접선방향 촬영법의 임상적 유용성)

  • Seo, Sun-Youl;Cho, Jeong-Hee;Han, Man-Seok;Kim, Tae-Hyung;Yoo, Se-Jong;Kim, Yong-Kyun;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2760-2766
    • /
    • 2013
  • Introduction : The projection method to check existence and nonexistence of radius groove penetration of screw after distal radius fracture operation clinical using the T-type plate and the radiation of radial groove tangential is to propose a new test. Material and Methods : On the tangential projection view of radius groove, elevation angle of distal radius is 2.5, 5, 7.5, 10 degree. and forearm and radiation detector of angle is 60, 70, 80, degree each changed. that analyzed check existence and nonexistence of radius groove penetration of screw. Results : For the image of Radial groove tangential. the case of not radius groove penetration of screw(63.95%, n=55), medial penetration of radius groove(10.47%, n=9) or lateral penetration of radius groove(25.58%, n=22) was analysis. The radius groove penetrating of screw length was a range of 0.43 ~ 2.72mm, the average was 1.06mm. the check existence and nonexistence of radius groove penetration of medial or lateral was analysis that it accurate for the image of Radial groove tangential. the radiography of radial groove is well described elevation angle of distal radius 2.5 to 7.5 degree(90% over), forearm and radiation detector of angle 70degree(80%over) Conclusion : It is elevation angle of distal radius is 5degree, forearm and radiation detector of angle 70degree recommended.

Surgical Correction of an Antebrachial Deformity with Severe External Rotation in Two Dogs (심각한 외측 회전을 동반한 전완 기형의 외과적 교정 치료 2 증례)

  • Yoon, Hun-Young;Roh, Mi-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.28 no.3
    • /
    • pp.328-331
    • /
    • 2011
  • Two dogs presented to the Dueckso Animal Hospital with a history of intermittent lameness of the left forelimb. On physical examination, a visible antebrachial deformity that resulted in gross external rotation of approximately $90^{\circ}$ was observed in two dogs. Medial-lateral radiographic views revealed distal ulnar subluxation, cranial bowing of the radius, radial and ulnar shortening, and external rotation of the paw. A distal ulnar ostectomy and distal radial closing wedge osteotomy were performed in two dogs. A proximal ulnar osteotomy was performed, adjacent to the elbow joint in case 1. Then, the osteotomized site was supported with an intramedullary pin. A T-plate and cortical screws were applied to the proximal and distal radial segments after derotating the distal segment internally. Postoperative radiographic view verified the correction of the angular deformity in two dogs. The follow-up was completed by physical examination 6 and 10 months after surgery respectively. There was no evidence of lameness of the left forelimb in two dogs. Gross observation of the limb revealed an apparent appropriate correction of the rotational and angular deformity in two dogs.

Clinical Analysis of Fractures by Inline Skating Injury (인라인 스케이트시 발생된 골절의 임상적 고찰)

  • Choi Hyung Suk;Doh Hyun Woo;Lee Byung Ill;Min Kyung Dae;Rah Soo Kyun;Kim Yeon Ill;Seo Yoo Sung
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.3 no.1
    • /
    • pp.87-91
    • /
    • 2004
  • Purpose: The purpose of this study is to investigate the incidence and patterns of fractures occurred in Inline skating accident. Materials and Method: We evaluated 20 patients, 20 cases(from september 2002 to August 2003) with fractures occurred during Inline skating. The incidence, sex, age, fracture site, associated injuries, causes of Inline skating injuries were analysed. The cases were male in 18(90$\%$), and female in 2(10$\%$). The most common distribution of age was in twenties and thirties. Result: The patients(12cases 60$\%$) with upper extremity fracture were more common than patients(8cases 40$\%$) with lower extremity fracture. Patients who had fracture in ankle were 35$\%$(7cases), forearm 20$\%$(4cases), wrist 20$\%$(4cases), elbow 15$\%$(3cases), thigh 5$\%$(1cases). According to the The Lauge-Hansen classification in ankle fractures there were four patients of supination-external rotation type, two patients of supination-abduction type, and 1 patient of pronation-external rotation type. In forearm and hand fractures, there were three distal radius fractures, one radio-ulnar shaft fracture, 2 scaphoid fractures, and two meta-carpal fractures. In elbow fractures, there were two supracondyle fractures, and one lateral condyle fracture. There were three epiphyseal plate injuries (Salt-Harris type II) in children, and all of them were treated by conservative method. Six fractures were intra-articular fractures. The most common associated injury was contusion(8cases 42.1$\%$). The number of patients who only rode Inline skating less than 3months(8cases 40$\%$) was the greatest. The number of non-contact injury(14cases, 70$\%$) in Inline skating was more than contact(6cases,30$\%$) injury. 11cases(55$\%$) had operative treatment, and 9cases(45$\%$) had conservative treatment, and there was not any complication. The more detailed study is required since the materials were only limited to fracture patients, and the follow up period was short. Conclusion: The most common age for fracture in Inline skating was in twenties, and thirties, and ankle was the most common fracture site.

  • PDF

Injuries Associated with Inline Skating (인라인스케이트와 관련된 손상)

  • Song Ha Heon;Kim Joung Woo;Cho Yong Woo;Yang Jung Hwan
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.3 no.1
    • /
    • pp.25-30
    • /
    • 2004
  • Objective: Recently, inline skates are populary increasing and have become major recreational activities. This study was performed to determine the effective prevention means on various extremity injury by investigating injury severity occording to acute injury and overuse injury. Results: Acute inline skating injury was experienced mostly among the age between 6$\~$14 years old children after school around nearby their home without using no appropriate safety device gear. The wrist injury was mostly happened. We think that overuse injury is related to boot itself, boot fitting and improper skating techniques. Conclusion: So afterall, appropriate safety equipment wearing in inline skating at the safe place after learning about the skating skills can reduce the acute inline skating extremity injuries. Choosing a pair of good fitting boots, performing the exact pushing techniques and take good rests in the middle of skating frequently can reduce the overuse injury.

  • PDF