• Title/Summary/Keyword: 외측 회전

Search Result 88, Processing Time 0.037 seconds

A Study on the Variable Speed Control Characteristics of Outside Rotor type Squirrel Cage Induction Motor (외측 회전형 농형 유도전동기의 가변속 운전특성에 관한 연구)

  • 안병원;박영산;노영오;최민선;김성환;김현수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.418-422
    • /
    • 2001
  • This paper presents a developed squired cage induction motor for axial flow fan. The developed squirrel cage induction noter for axial flow fan is exchanged the position, rotor and stater. In this method a fan blade is attached to outside rotor. So we can protect the motor from rain and reduce noise, and there is no need to have bending duct to locate the fan motor. Carried out experimental test with this induction motor, and the results were as follows. Starting torque was 21kgㆍcm@120V, maximum efficiency was 0.84@120V. The characteristics of tests were the same as double squirrel-cage type IM.

  • PDF

OTOTOXICITY ASSOCIATED WITH CISPLATIN (Cisplastin 투여에 따른 청력변화)

  • 이종철;고의경;왕수건;전경명
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1987.05a
    • /
    • pp.5.1-5
    • /
    • 1987
  • Cisplatin (cis-dichlorodiamine platinum II)은 두경부 및 고환의 악성종양에 아주 효과적이라고 알려져 있다. 그러나 이 약물은 이독성 및 신독성이 이미 임상연구로 발표되어 있으며 신독성은 cisplatin 투여시 이뇨제 및 수액의 투여로 그 정도 및 빈도는 감소시킬 수 있지만 이독성은 감소시키지 못한다. Cisplatin에 의한 이독성은 보통 자각적으로 나타나지 않는데 이는 내이 와우각의 회전중 저부에서 일어나며 또한 외유모세포의 최외측열에서 일어난다고 동물실험에서 밝혀진 바 있다. 본 교실에서는 cisplatin의 이독성을 관찰하기 위하여 1회에 cisplatin 60~80 mg/$m^2$을 투여한 두경부 악성종양환자를 대상으로 투여전후의 청력을 비교 관찰하였다. 1) 청력은 대부분 10㏈ 이내의 손실례가 많았다. 2) 최대청력손실이 있는 주파수는 8KHz, 4KHz의 순으로 주로 고음역에서 발생하였다. 3) 신독성은 전례에서 관찰되지 않았다.

  • PDF

Experimental Study of Secondary Flow Using Real-scale Experiment Channel (실규모 실험수로를 이용한 이차류 특성에 대한 실험적 연구)

  • LEE, Du Han;SON, Minwoo;KIM, Young Do;KIM, Jung Min
    • Journal of The Geomorphological Association of Korea
    • /
    • v.19 no.4
    • /
    • pp.13-25
    • /
    • 2012
  • This study aims to experimentally investigate the characteristics of secondary flows in a natural channel. For this objective, various conditions of water discharge and depth are tested in a real-scale experimental channel which has 1.2 of meandering. From results of experiments, it is observed that the maximum flow velocity exists in the outer zone of ben. This result is different from the previous studies conducted with laboratory experiments. The bank of 1:2 slope replicating the condition of natural channel is considered to cause this result. The location of the maximum flow velocity moves to the center of channel as the channel changes to be straight. It is also known from this study that two vorteces coexist on the left and right banks of bend.

Combined Reconstruction of Posterior Cruciate Ligament and Posterolateral Corner with a Fresh Frozen Achilles Tendon Allograft (한 개의 신선동결 동종아킬레스건을 이용한 후방십자인대 및 후외방구조의 동시 재건술)

  • Kyung, Hee-Soo;Oh, Chang-Wug;Lee, Hyun-Joo;Ihn, Joo-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.102-108
    • /
    • 2009
  • Purpose: The purpose of this study is to report a result of the technique that reconstruct posterior cruciate ligament (PCL) and posterolateral corner (PLC) simultaneously using a fresh-frozen Achilles tendon allograft. Materials and Methods: Forty two patients (45 legs) underwent PCL and PLC reconstruction were included. There were 38 males and 4 females. Mean age was 39 years. Used graft was a fresh frozen Achilles tendon allograft, which was divided by two size, larger one (${\emptyset}$ 10 mm) for PCL reconstruction and smaller one (${\emptyset}$ 8 mm) for PLC reconstruction. Arthroscopic reconstruction of the PCL was performed using transtibial, single incision, and single bundle technique with 10mm fresh frozen Achilles allograft tendon first. After PCL reconstruction, reconstruction procedure for posterolateral instability was performed using modified figure of "8" technique using smaller gtaft. For clinical evaluation, range of motion, posterior drawer test, varus stress test, prone external rotation (dial) test, Lysholm score, Tegner activity scale and posterior stress radiograph were used. Mean follow up period was 25 months. Results: Preoperatively posterior drawer test was 5 cases in grade II and 40 cases in grade III posterior instability. At final follow-up 22 cases returned within normal condition, 18 cases grade I and 5 cases grade II posterior instability. Though all patients showed positive result over 10 degrees in dial and varus stress test preoperatively, but only 9 cases showed positive both test at final follow-up. The range of motion deficit over $10^{\circ}$ flexion was 3 cases. Lysholm score was improved from mean 50 preoperatively to mean 83(p<0.05) and Tegner activity scale improved from mean 2.1 preoperatively to mean 4.6(p<0.05). In posterior stress radiographs, posterior displacement was improve from mean 16mm preoperatively to 4.1mm after treatment(p<0.05). All patients had improved compared to their pre-operative status as measured by physical examination such as posterior drawer test, varus stress test, dial test. Conclusion: We had successful results by combined reconstruction of the PCL & PLC with a fresh frozen Achilles tendon allograft in patients with PCL and posterolateral rotatory instability at a time.

  • PDF

Reconstruction after Wide Excision of Malignant Soft Tissue Tumor in Ankle and Foot (족관절 및 족부에 발생한 연부 조직 악성 종양의 광범위 절제술 후 재건술)

  • Kwon, Young-Ho;Cho, Yool;Kim, Jae-Do;Chung, So-Hak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.14 no.1
    • /
    • pp.33-43
    • /
    • 2008
  • Purpose: To evaluate the clinical usability of reconstructive methods, and how to select flap after wide excision of malignant soft tissue tumor in ankle and foot. Materials and Methods: The 15 cases shown in the 14 patients (In case of a male patient, reconstruction was performed two times due to local recurrence.) with malignant soft tissue tumor in ankle and foot, who underwent reconstruction after wide excision from March 2000 until March 2007. Oncologic, surgical and functional results were evaluated. Results: The method of reconstruction used were anterolateral thigh perforator flap (5cases), Reversed superficial sural artery flap (4 cases), dorsalis pedis flap (3 cases), local flap (3cases). The defect, mean size was $5.5{\times}5.7\;cm$, was reconstructed with rotation flap or free flap, mean size was $5.9{\times}6.0\;cm$, skin graft for remnant. The mean operation time was 310 minutes (120~540 minutes); it took 256 minutes to reconstruct by rotation flap, and 420 minutes by free flap. As oncologic results, 7 patients were no evidence of disease, 6 patients were alive with disease and 1 patient was expired by pulmonary metastasis at the time of the last follow-up. 4 patients had local recurrence and 4 pateints had distant metastases. As functional results, 14 patients were evaluated with average score of 68.8% using the system of the Musculoskeletal Tumor Society. Conclusion: The dorsalis pedis and reverse superficial sural artery rotation flap which is easy procedure, has less complication and takes short operation time, can be primarily considered to reconstruct a small defect. And the anterolateral thigh perforator flap is suitable for coverage of a large defects after wide excision of malignant soft tissue tumor in ankle and foot.

  • PDF

Biomechanical Alterations in the Lower limb Joints during the Punching Motion of Elderly Women after 12-Weeks of Taekwonaerobics Training (여성노인의 태권에어로빅스 12주 훈련 후 몸통지르기 동작시 하지관절의 생체역학적 변화)

  • Yoo, Sil
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.637-645
    • /
    • 2009
  • The purpose of this study was to investigate the biomechanical alterations in the punching motion of 10 elderly women after 12 weeks of taekwonaerobics training. Seven infrared cameras(Qualisys MCU-240) and 2 force platforms(Kistler-9286AA) were used to acquire raw data. The results were as follows. First, the minimum joint angles of the lower limbs had a statistically significant difference between both the dorsiflexion/plantar flexion(1eft, $p=0.001^*$) and the inversion/eversion(both, $p=0.009^*$, $p=0.04^*$) from the ankle angle. There were differences in abduction/adduction(left, $p=0.04^*$) from the knee angle, as well as internal/external rotation(both, $p=0.07^*$, $p=0.02^*$) from the hip angle. Second, the maximum resultant joint moments of the lower limbs had statistically significant differences in the inversion/eversion moment from the ankle joint(both, $p=0.05^*$, $p=0.05^*$), the abduction/adduction moment(left, $p=0.08^*$) from the knee joint, and the internal/external rotation moment(right, $p=0.09^*$) from the hip joint. Third, the maximum resultant joint powers of the lower limbs had a statistically significant difference both in flexion/extension joint powers(both, $p=0.05^*$, $p=0.01^*$) and in abduction/adduction(both, $p=0.02^*$, $p=0.00^*$) from the hip joint, as well as abduction/adduction(left, $p=0.00^*$) from the knee joint, In conclusion, the elderly women were somewhat changed after 12 weeks of taekwonaerobics training.

Analysis of the Movement and Anatomical Angular Motion of the Joints of the Lower Extremities in Soccer Instep Kick (축구 인스텝 킥의 하지관절 움직임과 해부학적 각운동 분석)

  • Kang, Sang-Hack;Son, Won-Il
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • This study analyzed the rear foot angle of the supporting leg and the anatomical rotation angle of the kicking angle in soccer instep kick and drew conclusions as follows. When the supporting leg was landing on the ground, the valgus angle of the ankle joint reached the maximum peak, and plantar flexion was slightly different in the timing of the maximum peak between the two groups. The flexion angle of the rear foot was statistically significantly different between the two groups, and the movement of the crus on the landing of the supporting foot did not show a statistically significant difference between the groups. The crus leaned backward most before the impact, and the side to side gradient of the crus on impact was $22^{\circ}$. The flexion/extension of the hip joint of the kicking leg reached the maximum peak when the supporting foot was landing on the ground, and at the moment, the maximum extension angle of the hip joint was over $30^{\circ}$. The flexion angle of the knee joint of the kicking leg was largest after landing. While the maximum plantar flexion angle and maximum valgus angle of the ankle joint were not significantly different between the two groups, the maximum external rotation angle was significantly different.

A Study of Ultrasonic concentrator with Rotating parablic surace (회전 기물면을 이용한 초음파 집속기에 관한 연구)

  • 김주홍;전병실
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 1974
  • This paper discribes the reflector type ultrasonic concentrator which makes hghintencity of ultrasonic field. This was made by rotating parabolic surface which only using total reflection aria, that makes boundary by the critical angle of reflection of sound. I made two binds of concentrator acording to the type of ultrasonic transduser: one is internal surface reflector type concentrator, which is available for disc type transducer, and the other is external surface reflector type concentrator which is available cylinderical transduser. In the mony aspects the reflector tripe concentrator is supel'ier to the reflection type concentrator as plastics lens; It is more durable in high temperature and high intencity ultrasonicfield then refrector type concentrator because of it is made by glass or metal, and it has higher. efficiency because of it wasts made by only total reflection aria that is without absoption lose. I think this is useful ultrasonic concentrator in mony industrial field, in which high intencitr of ultrasonic energy was used.

  • PDF

Mechanization of Fishing Operation on the Sea Eel Pots (장어통발 어업의 자동기계화에 관한 연구)

  • Ha, Jeong-Sik;Kim, Yong-Hae;Jang, Chung-Sik
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.1
    • /
    • pp.45-50
    • /
    • 1990
  • The basic investigation of the sea eel pots fisheries by questionnarie observation and dimension of the pots by fishing operation were carried out in order to develop for mechanical hauling system with 20~50 gross tonnage fishing boats from June to December, 1988. Number and weight of fish per pot between smaller diameter 11cm and larger 13cm of the pot have no significance so that the drag of the smaller pots can be decreased about 20% than the larger pots. The operating time by two men from opening to closing with screwing lock entrance was slightly faster than that by three men with knotting entrance even though the losses with two kinds of entrances while fishing operation were about the same. It was very reasonable that stone and lead sinker on the main line were substitute for two or three lead core P.P rope to make it smooth surface of the main line for mechanization of the continuous fishing operation.

  • PDF

A Case of New Surgical Correction of Angular Limb Deformities Using One Screw Implant & Periosteal Transection in a Thoroughbred Foal (Thoroughbred 망아지에서 단일나사못 장착 및 골막박리를 이용한 지세교정술)

  • Yang, Jae-Hyuk;Lim, Yoon-Kyu
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.177-180
    • /
    • 2012
  • Angular limb deformities (ALD) are common in foals. A 30-days-old Thoroughbred foal was presented for the evaluation of severe ALD of the both forelimbs. On radiographic examination, both distal radiuses were diagnosed as valgus angular limb deformities. But the degree of deviation of right forelimb was so severe that we tried to correct one after the other. We tried new surgical correction method combination of one screw implant on medial aspect for growth retardation and periosteal transection on lateral aspect of the right forelimb. 40 days later, successfully corrected and then removed the screw. After the right forelimb correction, the periosteal transection on left forelimb was performed. We did the inhalation anesthesia using isoflurane. There were no complications such as fibrosis over the screw heads, and overcorrection that produces an opposing deformity identified. These results suggest that combination of one screw implant and periosteal transection technique is able to be a safe and effective method to correct severe ALD in the foal.