• Title/Summary/Keyword: 외고정

Search Result 379, Processing Time 0.024 seconds

A Study on the Utilization of Effluent Treated by Double Process Using Fixed-media and Sand Filter Coated by Nano Silver for Wastewater Reclamation and Reusing System (고정상 담체와 은나노 모래여과를 이용한 이중 공정에서 처리수의 중수도 활용에 관한 연구)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.21 no.4
    • /
    • pp.317-323
    • /
    • 2006
  • This study focused on the availability of wastewater reclamation and reusing system as one of the alternatives against the global water shortage in near future, which system is composed of two treatment steps; first, wastewater is injected into upflow $A^2O$ biofilm process(anaerobic/anoxic/oxic) reactor filled with polyethylene fixed-media, and the effluent of 1st steps continuously passed through downflow nano silver sand filter. The pH of the effluent ranged from 7.39 to 8.06(average 7.84), the $COD_{Mn}$ was $8{\sim}18mg/L$(average 12.1 mg/L), and $BOD_5$ was $2.1{\sim}10.0mg/L$(average 4.9 mg/L), that met all the wastewater reclamation and reusing system criteria. Besides, the SS concentrations of the effluent which was $3{\sim}9mg/L$(average 4.95 mg/L) met the criteria(5 mg/L), showing 94.8% of average removal efficiency. The 99.1% of the average removal efficiency of the E-coliform did not met the criteria(Not detected), which indicates the needs for the following chlorine disinfection treatment with the residual chlorine concentration of above 0.2 mg/L. There are no bacteria on the sand surface coated by nano silver. The removal efficiency of T-N and T-P that could be included into the criteria in the future was 50.3% and 27.2% respectively.

In Vitro Assessment of MRI Safety at 1.5 T and 3.0 T for Bone-Anchored Hearing Aid Implant (Bone-Anchored Hearing Aid Implant에 대한 1.5 T와 3.0 T에서 MRI 안전성의 생체외 평가)

  • Yeon, Kyoo-Jin;Kim, Hyun-Soo;Lee, Seung-keun;Lee, Tae-Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.19-25
    • /
    • 2017
  • The aim of this study was to evaluate Magnetic Resonance Imaging safety by measuring the translational attraction, torque and susceptibility artifact for Bone-Anchored Hearing Aid (BAHA) implant at 1.5 T and 3.0 T MRI by standard criteria. In vitro assessment tools were made of acrylic-resin by American Society for Testing and Materials (ASTM) F2052-06 and F2119-07 standard. Translational attraction of BAHA implant was measured by the maximum deflection angle at 96 cm position, where the magnetically induced deflection was the greatest. The torque was assessed by the qualitative criteria of evaluating the alignment and rotation pattern, when the BAHA implant was positioned on a line with $45^{\circ}$ intervals inside the circular container in the center of the bore. The susceptibility artifact images were obtained using the hanged test tool, which was filled with $CuSO_4$ solution. And then the artifact size was measured using Susceptibility A rtifact Measurement (SA M) software. In results, the translational attraction was 0 mm at both 1.5 T and 3.0 T and the torque was 0(no torque) at 1.5 T, and +1(mild torque) at 3.0 T. The size of susceptibility artifacts was between 13.20 mm and 38.91 mm. Therefore, The BAHA implant was safe for the patient in clinical MR environment.

Prediction of Performance of Waterjet Propulsors by Surface Panel Method (패널법에 의한 물 분사 추진장치의 성능해석)

  • Moon, II-Sung;Lee, Chang-Sup;Song, In-Haeng;Kim, Ki-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.34 no.4
    • /
    • pp.31-41
    • /
    • 1997
  • This paper describes a potential-based panel method formulated for the prediction of the steady performance of a waterjet propulsor. The method employs normal dipoles and sources distributed on the solid surfaces such as the impeller/stator blades, hub and duct, and normal dipoles in the shed wakes trailing the impeller and stator to represent the potential flow around the waterjet propulsor. To define a closed boundary surface, the inlet and outlet open boundary surfaces are introduced where the sources and dipoles are distributed. The kinematic boundary condition on the solid boundary surface is satisfied by requiring that the normal component of the total velocity should vanish. On the inlet surface, the total inflow flux into the duct is specified, and on the outlet surface the conservation of mass principle is applied to evaluate the source strength. The solid surfaces are discretized into a set of quadrilateral panel elements and the strengths of sources and dipoles are assumed constant at each panel. Applying this approximation to the boundary conditions leads to a set of simultaneous equations. Systematic numerical tests show that the present numerical method is fast and stable. In order to validate the present method, sample computations are carried out first for the case of a conventional axial flow fan which has a similar geometry as the waterjet propulsor, and then for the case of a waterjet propulsor on which experiments are carried out at KRISO(Korea Research Institute of Ships and Ocean Engineering).

  • PDF

Organic Solvent Stable Lipase from Pseudomonas sp. BCNU 171 (Pseudomonas sp. BCNU 171이 생산하는 유기용매 내성 리파아제)

  • Choi, Hye Jung;Kwon, Gi-Seok;Joo, Woo Hong
    • Journal of Life Science
    • /
    • v.25 no.3
    • /
    • pp.345-348
    • /
    • 2015
  • An organic solvent stable lipase from solvent-tolerant Pseudomonas sp. BCNU 171 had an optimal pH of 8 and an optimal temperature of 37℃. This crude extracellular lipase from BCNU 171 exhibited increased stability in the presence of various types of solvents at high concentrations (25%, v/v). The lipase stability was found to be highest in the presence of xylene (137%), followed by toluene (131%), octane (130%), and butanol (104%). Overall, BCNU 171 lipase tended to be more stable than immobilized commercial lipase (Novozyme435) in the presence of organic solvents. Furthermore, BCNU 171 lipase maintained about 90% of its enzyme original activity in the presence of NH4+, Na+, Ba2+, Hg2+, Ni2+, Cu2+, and Ca2+ion and significantly increased its enzyme activity in the presence of various emulsifying agents. Thus, the organic solvent stable lipase from Pseudomonas sp. BCNU 171 could be usable as a potential whole cell biocatalyst and for synthetic applications of enzymes for industrial chemical processes in organic solvents without using immobilization.

Stand Growth Analysis and Carbon Storage/Removals Assesment using the Data of Forest Growth Monitoring Plots (고정조사구 자료를 이용한 임분생장 해석 및 탄소흡수${\cdot}$저장량 평가)

  • Kwon Soon Duk;Son Yeong Mo;Lee Kyeong Hak;Chong Se Kung;Kim Jung Myeong
    • Journal of Korea Foresty Energy
    • /
    • v.23 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • This study looked into the change of tree growth of seven forest growth monitoring plots which were set up at the Undulyeong Hongchungun Kangwondo, and was accomplished to offer the basic data for the forest administration calculating carbon storage and removal in the Undulyeong area. Annual height and DBH growth were slowly progressed in the Pinus koraiensis and Larix kaempferi stand which was young stand, but the growth rate of the other stands was lower than those young stand. The diameter class of the mixed forest and Qurcus mongilica stand was predicted to be similar to the now and Pinus koraiensis and Larix kaempferi stand was predicted to move now diameter class to the high diameter class because thickening growth speed of the those stands were rapid. Now the end of 2003, total carbon storage of the Undulyeong model forest increased 149,000TC$(2.7\%)$ compared with the previous year. Seeing by forest types, occupied broad-leaved forest$(50\%)$, mixed forest$(34\%)$ and coniferous forest. During in 2003, total carbon which was removed and stored according to growth of the forest was 156,813TC and net carbon removal(148,664TC) increased into 2,613TC$(1.8\%)$ compared with the previous year. Seeing by forest types, occupied coniferous forest$(3.3\%)$, mixed forest$(3.1\%)$, broad-leaved forest$(2.8\%)$. Resultingly, the Undulyeong model forest is acting to net removal resource when see as green-gas side and net carbon removal are showing the tendency to increase recently little by little.

  • PDF

Relationship between competition in banking industry and bank's risk-seeking tendency (은행산업에서의 경쟁과 위험추구)

  • Sung, Jimin;Park, Chang Gyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.225-233
    • /
    • 2016
  • This study examined how the level of competition in the banking industry affects the risk-seeking tendency of individual banks. In earlier studies, the NPL ratio was used as an indicator of the risk-seeking tendency, but this ratio has limits because it is an ex post indicator of the risk. Therefore, the asset risk was chosen as a new indicator of the risk-seeking tendency, which is an ex ante measure of the risk, and the data were analyzed. The results suggested that there is a negative correlation between the level of competition of the banking industry and the risk-seeking tendency. Interestingly, opposite results were obtained when the NPL ratio was applied as an indicator of risk-seeking tendency. Therefore, the correlation between the level of competition in the banking industry and the risk-seeking tendency depends on the indicator of the risk-seeking tendency. This means choosing the appropriate indicator is the key component leading to precise results. The asset risk is more consistent with the concept of risk-seeking tendency than the NPL ratio, and it is a more appropriate indicator considering that the asset risk is a relatively less affected indicator other than risk-seeking tendencies.

Treatment of Type 2 Distal Clavicle Fracture using Wolter Plate (Wolter 금속판를 이용한 제 2형 원위부 쇄골 골절의 치료)

  • Shin, Sung-Il;Song, Kyung-Won;Lee, Jin-Young;Lee, Seung-Yong;Kim, Gab-Rae;Hyun, Yoon-Suk;Lee, Kwang-Nam;Lee, Eun-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • Purpose: This study examined the clinical results of the treatment of type 2 distal clavicle fracture with using a Wolter plate. Materials and Methods: Between 2004 and 2007, 16 patient treated for type 2 distal clavicle fracture using a Wolter plate were included in this study. Their average age was 32.6 years and the postoperative mean follow-up period was 22.9 months. The reduction and union were qualified according to the immediate post-operative and final radiographs. The functional outcome was evaluated by Kona's system and the Constant score Results: By Kona's functional evaluation, there were 12 cases with excellent results, 3 cases with good results and 1 case of fair results and the average Constant score was 90. All 16 cases showed bony union. As complications, there was 1 case in which the protruded hook of the plate could be palpated at the skin, and 1 case showed an acromial fracture, but all the cases dispalyed successful bony union and there was no acromioclavicular joint arthritis, infection or any other complications. Conclusion: Wolter plate fixation for type 2 distal clavicle fracture is a reliable surgical method for satisfactory reduction and rigid fixation, a lower incidence of nonunion and excellent clinical result.

Study on the Necessity and Specific Recommendations for Enhancing the Legal Requirements for Underwater Recreational Vessel Propeller Guards (수중레저선박 스크류망 제도개선의 필요성과 구체적인 제안)

  • Jung-Soo Lee;Jeong-Tack Min;Ho-Yun Jang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.226-232
    • /
    • 2024
  • During scuba diving in Korea, accidents involving bodies being struck by the ship propeller when entering and exiting the water, repeatedly occur every year. In response to the need to reduce accidents and implement safety management measures, Korea has established regulations for the installation and management of propeller guards. However, owing to the absence of clear production regulations in domestic laws and regulations, the installation standards are ambiguous, and the inspection items are limited to the appearance and fixation status. As a result, the safety of divers in propeller accidents is not guaranteed. Therefore, this study was conducted to specify the current legal requirements for the installation and inspection of propeller guards. To achieve this goal, we conducted a thorough analysis of the current state of domestic and foreign propeller guards and the legal factors pertaining to safety standards. Based on this analysis, we identified specific areas for improvement and proposed a plan to enhance the system for installation and inspection. The installation standards for propeller guards were clearly outlined in terms of the lattice size and material. Additionally, inspection standards were proposed for appearance, fixation, and material condition, along with clear indicators for assessing them.

A Clinical Analysis of Femur Neck Fracture in Elderly Patients (노년층에서 대퇴경부 골절의 치료)

  • Ihin, Joo-Choul;Ahn, Myun-Whan;Seo, Jae-Sung
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.11-22
    • /
    • 1985
  • Femur neck fracture is well known as one of the major death cause after trauma in elderly patients, and unsolved fracture due to its frequent association with complications such as avascular necrosis and nonunion. Through meticulous evaluation of the patient, hip and surgeon's experiences, reduction of mortality and morbidity as well as rapid recovery of the patient to the preinjury social and ambulatory status without local complications and revision after treatment is urgently needed. Many factors about this fracture In itself were noted, but we have analyzed 18 femur neck fractures of the patients older than 50 years preliminarily according to age, fracture pattern, osteoporosis, etiology and method of treatment with its delay in association with major complications especially avascular necrosis and nonunion. The results are as follows; 1. Of these 18 fractures, 11 were in females, 8 were caused by minor trauma such as slip-down accident and 4 were associated with definite osteoporosis according to the Sing's classification. 2. Fracture pattern of these 18 are undisplaced in 4, displaced subcapital in 11, displaced transcervical in 3. 11 fractures in the patients older than 60 year are composed of 3 undisplaced or impacted fractures and 8 displaced subcapital fractures. 3. These 18 fractures were treated by closed reduction and Internal fixation with multiple pins in 13, and hemiarthroplasty in 4, but one was not treated to die after discharge from hospital. 4. 4 undisplaced or impacted fractures and 3 displaced transcervical fractures were not associated with any complications such as avascular necrosis or nonunion. But 4 of 6 displaced subcapital fractures were complicated by avascular necrosis, 3 of which were reduced in the varus position within 1 week, and the other was reduced in the good position on 1 week after trauma. There was no complication in 2 displaced subcapital fractures reduced in valgus position within 3 days after trauma. According to the above results, the prognosis of the femur neck fracture is dependent upon the fracture pattern and delay in its treatment. So it is inevitable to reduce the fracture in anatomical or valgus position as early as possible. But the arthroplasty may be needed in displaced subcapital fractures delayed for several days, with its reluction in extreme varus position or impossible and with pre-existing disease in the same hip Joint (total hip replacement).

  • PDF

Mid-Term Results of Fixed Bearing Unicompartmental Knee Arthroplasty: Minimum 5-Year Follow-Up (고정형 슬관절 단일 구획 치환술의 중기 추시 결과: 최소 5년 추시)

  • Oh, Jeong Han;Joo, Il-Han;Kong, Dong-Yi;Choi, Choong-Hyeok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.498-504
    • /
    • 2018
  • Purpose: To evaluate the clinical and radiological outcomes, and the complications of unicompartmental knee arthroplasty (UKA) using a fixed bearing prosthesis after 5-year follow-up. Materials and Methods: Twenty-six knees (25 patients) that underwent fixed bearing UKA between May 2003 and August 2011 were included. The subjects were 3 males (3 knees) and 22 females (23 knees), and the average age was 63.5 years. The preoperative diagnosis was osteoarthritis (23 knees) and osteonecrosis (3 knees). The mean follow-up duration was 67 months (from 60 to 149 months). The clinical evaluation included pre- and postoperative American knee society knee and function score, and range of motion. The radiology evaluation included standing antero-posterior, lateral view, and fluoroscopic film to analyze the postoperative alignment and osteolysis. Results: The mean American Knee Society knee score and function score were improved from 42.0 and 57.5 to 87.9 and 85.0, respectively (p<0.001). The mean preoperative and postoperative range of motion was $132.9^{\circ}$ and $132.5^{\circ}$, respectively. The mean femorotibial angle were varus $0.5^{\circ}$ preoperatively and valgus $2.2^{\circ}$ postoperatively. A radiolucent line was observed in 2 knees; one knee had a stable implant, while in the other knee, patellofemoral arthritis was identified during UKA. Diffuse pain of the knee joint with tenderness of the medial joint line was identified at the follow-up, so conversion to total knee arthroplasty was recommended. No other complications, such as osteolysis, infections, postoperative stiffness, and dislocation, were encountered. Conclusion: The midterm results of fixed bearing UKA were clinically and radiologically satisfactory.