• Title/Summary/Keyword: 완충기

Search Result 237, Processing Time 0.026 seconds

Design and Implementation of Ku-Band VCO for Microwave Multi-Band Receiver (마이크로웨이브 다중 대역 수신기용 Ku-대역 전압 제어 발진기 설계 및 구현)

  • Go, Min-Ho;Cho, Ho-Yun;Park, Hyo-Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.853-861
    • /
    • 2009
  • In this paper, we propose the architecture of a multi-band receiver which can receive X-band, Ku-band, K-band and Ka-band signals. For implementing this architecture, we designed a wideband and high power VCO with a buffer stage. In order that a buffer does not affect the characteristic of a oscillation in steady state condition, output impedance of a oscillation part and input impedance of a buffer are orthogonally crossed. The fabricated VCO meets the performance parameter of the multi-band receiver which has a $14.00{\sim}15.20\;GHz$ bandwidth with respect to the tuning voltage, $0.0{\sim}8.0\;V$, and output power of $12{\sim}13\;dBm$.

Removal of Trichloroethylene, Cr(VI) and Nitrate in Leachate by Bentonite and Zero Valent Iron (벤토나이트와 영가 철에 의한 침출수 내의 Trichloroethylene, Cr(VI), 질산성질소의 제거)

  • Lee, Hyun-Joo;Park, Jae-Woo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.2
    • /
    • pp.23-31
    • /
    • 2004
  • Trichloroethylene(TCE), Cr(VI), and nitrate removal efficiency of a novel reactive barrier were experimented, and the types of corrosion species that form on the surface of the iron and bentonite as a result of reaction were investigated with Raman spectrophotometer. The reactive barrier is composed of bentonite and zero valent iron(ZVI), and this can substitute conventional geosynthetic clay liners for landfill leachate. Tests were performed in batch reactors for various ZVI content (0, 3, 6, 10, 13, 16, 20, 30, 100 w/w %) and pH. The reduction rates and removal efficiencies of TCE, Cr(VI) and nitrate increase at pH 7 buffered solution. As ZVI content increases, TCE, Cr(VI) and nitrate removal efficiencies increase. From the result of analysis with Raman spectrophotometer, Fe-oxides were observed, which are strong adsorbers of cantaminants. Magnetite can be also beneficial to the long term performance of the iron metal.

  • PDF

Dynamic Characteristic Analysis Procedure of Helicopter-mounted Electronic Equipment (헬기 탑재용 전자장비의 동특성 분석 절차)

  • Lee, Jong-Hak;Kwon, Byunghyun;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.759-769
    • /
    • 2013
  • Electronic equipment has been applied to virtually every area associated with commercial, industrial, and military applications. Specifically, electronics have been incorporated into avionics components installed in aircraft. This equipment is exposed to dynamic loads such as vibration, shock, and acceleration. Especially, avionics components installed in a helicopter are subjected to simultaneous sine and random base excitations. These are denoted as sine on random vibrations according to MIL-STD-810F, Method 514.5. In the past, isolators have been applied to avionics components to reduce vibration and shock. However, an isolator applied to an avionics component installed in a helicopter can amplify the vibration magnitude, and damage the chassis, circuit card assembly, and the isolator itself via resonance at low-frequency sinusoidal vibrations. The objective of this study is to investigate the dynamic characteristics of an avionics component installed in a helicopter and the structural dynamic modification of its tray plate without an isolator using both a finite element analysis and experiments. The structure is optimized by dynamic loads that are selected by comparing the vibration, shock, and acceleration loads using vibration and shock response spectra. A finite element model(FEM) was constructed using a simplified geometry and valid element types that reflect the dynamic characteristics. The FEM was verified by an experimental modal analysis. Design parameters were extracted and selected to modify the structural dynamics using topology optimization, and design of experiments(DOE). A prototype of a modified model was constructed and its feasibility was evaluated using an FEM and a performance test.

The Vibration Analysis of Snubber for Reciprocating Type Hydrogen Compressor (왕복동식 수소 압축기용 완충기 진동 특성 분석)

  • Kim, H.J.;Jang, Y.S.;Cho, S.W.;Choi, B.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.53-56
    • /
    • 2007
  • The reciprocating type hydrogen compressor is occurred by the pulsation from the mechanism and this pulsation is make much noise and vibration. Therefor snubber is installed for pulsation decreasing. The five type snubber models were designed for increasing pulsation amplitude reduction and decreasing pressure loss in snubber considering output pipe location as design value. And the pressure flued analysis is carried by CFD. In this paper, each type snubber according CFD result are analyzed by the MSC/NASTRAN to identify the vibration characteristic of each type. The vibration results are compared with CFD results.

  • PDF

Modeling and Analysis of the Dynamic Characteristics of Pipe Supporting Hydraulic Snubber in Electric Power Plant (발전소 배관지지용 유압완충기의 동특성 모델링 해석)

  • 이재천;황태영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.87-91
    • /
    • 1997
  • This paper presents the modeling and analysis of dynamic characteristics of hydraulic snubber in electric power plant. The nonlinear state equations of 9th order to describe the dynamics of the snubber was established by Sirnulink. The simulation results show that the hydraulic snubber reacts as like the conventional shock absolvers to the high pulse shock load. The snubber also shows the peculiar characteristics to the small step load, which are temporary locking displacements of control valves and same steady-state pressures of all internal chambers in the snubber.

  • PDF

On the Analysis of Dynamic Characteristics of Pipe Supporting Hydraulic Snubber in Electric Power Plant with State-space Model and Impulse Testing (상태공간 모델과 임펄스 시험에 의한 발전소 배관지지용 유압완충기의 동특성 해석)

  • Lee, Jae-Cheon;Im, Mun-Hyeok;Hwang, Tae-Yeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.130-138
    • /
    • 2002
  • This paper presents the modeling and analysis of dynamic characteristics of hydraulic snubber in electric power plant. The nonlinear state-space model of 14th order to describe the dynamics of the snubber was established by Simulink. The simulation results show that the hydraulic snubber reacts as like the conventional shock absorbers against the high pulse shock load. The snubber also shows the peculiar characteristics to the small step load, which temporarily lock the control valves up, however maintain same steady-state pressures of all internal chambers in the long run. Two case studies for the analysis of the snubber were addressed. Practical pulse testing method was also proposed to identify the frequency response characteristics of the snubber.

발전소 배관지지용 유압완충기 개발

  • Park, Tae-Jo;Koo, Chil-Hyo;Cho, Gwang-Hwan;Lee, Dong-Ryul;Lee, Hyun;Kim, Yeon-Hwan
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.232-238
    • /
    • 1997
  • In this paper, a theoretical method is presented to design a hydraulic control valve system that consist of an important component in the hydraulic snubber. The hydraulic snubber is used essentially to support the piping systems at power plants. To calculate the force due to pressure drop and flow rate in the valve orifice and by-pass hole, Bernoulli equation is used. The Reynolds equation are numerically analyzed in the clearance gap between the valve cone and valve seat to estimate the friction force and leakage flow rate. Based on the detailed theoretical data, we developed successfully the hydraulic snubber for power plants.

  • PDF

Drop Test for the UAV Landing Gear Performance Verification (무인정찰기 착륙장치 성능입증을 위한 낙하시험)

  • Shin, Jeong-Woo;Lee, Seung-Gyu;Yang, Jin-Yeol;Kim, Sung-Joon;Hwang, In-Hee;Chung, Sang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.250-254
    • /
    • 2011
  • Main role of landing gear is to absorb the energy which is generated by aircraft lanidng and ground maneuvering. Generally, in order to absorb the impact energy during landing, oleo-pneumatic type shock absorber is used for aircraft landing gear. Oleo-pneumatic type shock absorber has a good energy absorbing efficiency and is light in weight because its structure is relatively simple. For the landing gear development, it is necessary to conduct drop test in order to verify shock absorbing performance. In the drop test, first, gas spring curve verification tests are conducted. Then, limit and reserve energy absorption drop tests are performed based on the STANAG 4671. The drop tests results with performance analysis results are presented.

  • PDF

On the Analysis of Dynamic Characteristics of Pipe Supporting Hydraulic Snubber in Electric Power Plant with State-space Model and Impulse Testing (상태공간 모델과 임펄스 시험에 의한 발전소 배관지지용 유압완충기의 동특성 해석)

  • Lee, Jae-Cheon;Hwang, Tae-Yeong
    • 연구논문집
    • /
    • s.31
    • /
    • pp.89-99
    • /
    • 2001
  • This paper presents the modeling and analysis of dynamic characteristics of hydraulic snubber in electric power plant. The nonlinear state-space model of 14th order to describe the dynamics of the snubber was established by Simulink. The simulation results show that the hydraulic snubber reacts as like the conventional shock absolvers against the high pulse shock load. The snubber also shows the peculiar characteristics to the small step load, which temporarily lock the control valves up, however maintain same steady-state pressures of all internal chambers in the long run. Two case studies for the analysis of the snubber are addressed. Practical pulse testing method was also proposed to identify the frequency response of the snubber.

  • PDF

Evaluation of Mechanical Interactions Between Bentonite Buffer and Jointed Rock Using the Quasi-Static Resonant Column Test (유사정적 공진주 시험을 이용한 벤토나이트 완충재와 절리 암반의 역학적 상호작용 특성 평가)

  • Kim, Ji-Won;Kang, Seok-Jun;Kim, Jin-Seop;Cho, Gye-Chun
    • Tunnel and Underground Space
    • /
    • v.31 no.6
    • /
    • pp.561-577
    • /
    • 2021
  • The compacted bentonite buffer in a geological repository for high-level radioactive waste disposal is saturated due to groundwater inflow. Saturation of the bentonite buffer results in bentonite swelling and bentonite penetration into the rock discontinuities present around the disposal hole. The penetrated bentonite is exposed to groundwater flow and can be eroded out of the repository, resulting in bentonite mass loss which can affect the physical integrity of the engineered barrier system. Hence, the evaluation of buffer-rock interactions and coupled behavior due to groundwater inflow and bentonite penetration is necessary to ensure long-term disposal safety. In this study, the effects of the bentonite penetration and swelling on the physical properties of jointed rock mass were evaluated using the quasi-static resonant column test. Jointed rock specimens with bentonite penetration were manufactured using Gyeongju bentonite and hollow cylindrical granite rock discs obtained from the KAERI underground research tunnel. The effects of vertical stress and saturation were assessed using the P-wave and S-wave velocities for intact rock, jointed rock and jointed rock with bentonite penetration specimens. The joint normal and joint shear stiffnesses of each joint condition were inferred from the wave velocity results assuming an equivalent continuum. The joint normal and joint shear stiffnesses obtained from this study can be used as input factors for future numerical analysis on the performance evaluation of geological waste disposal considering rock discontinuities.