• Title/Summary/Keyword: 완전순환이용

Search Result 109, Processing Time 0.041 seconds

A Study on the Technique to Manufacture Recycled Cement from Cementitious Powders for Complete Recycling of Concrete Structures (콘크리트 구조물의 완전순환이용을 위한 폐콘크리트계 미분말의 재생시멘트 활용 기술 연구)

  • Park, Cha-Won;An, Jae-Cheol;Gang, Byeong-Hui
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.143-151
    • /
    • 2004
  • The purpose of this study is development of technique to use cementitious powder as recycle cement produced from deteriorated Concrete waste which has a large quantity of calcium carbonate. Therefore, after having theoretical consideration based on the properties of high-heated concrete and concerning about neutralization of Concrete, we analysis chemical properties of ingredients of cementitious powder. After making origin cement paste, then processing the accelarated carbonation, we consider the properties of hydration and chemical properties of cementitious powder under various temperature conditions. As a result of the thermal analysis, the $CaCO_3$ content of cementitious powder would affect decision of heat temperature to recover its hydrated ability because $CaCO_3$ content is increased when neutralization is progressed. And as a result of XRD analysis, in case of origin powder of non-neutralized paste, CaO peak is found at $700^{\circ}C$. but, heat temperature to generate CaO would increase when the content of neutralized ingredients is increased. Finally, recycle cement heated at $700^{\circ}C$ 120min. shows the best compressive strength when the content of neutralized ingredients in recycle cement is less then 50%.

A High-performance Parallel Algorithm for D-Class Computation based on Shared Memory (공유 메모리 기반의 고성능 D-클래스 계산 병렬 알고리즘)

  • Shin Chul-Gyu;Han Jae-Il
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07a
    • /
    • pp.10-12
    • /
    • 2005
  • [$n\timesn$] 불리언 행렬의 집합에서 동치관계를 이용하여 정의된 D-클래스는 개인키나 공개키 암호기술에 사용될 수 있는 가능성을 가지고 있다. 그러나 NP-완전 문제인 계산 복잡도로 인해 D-클래스의 효율적인 계산이 어려워 극히 제한된 크기의 행렬에 대한 D-클래스만이 알려져 있다. D-클래스를 효율적으로 계산하기 위해서는 수식변환, 병렬처리, 순환문 개선 등을 통해 알고리즘을 개선하여야 한다. 본 논문은 D-클래스의 효율적 계산을 위해 공유메모리 기반의 병렬 처리에 적합하도록 수식의 대수적 변환을 이용한 알고리즘의 설계라 실행 결과에 대해 논한다.

  • PDF

Surgical Treatment of Intramural Hematoma of the Aorta Case Report (대동맥벽내 혈종의 수술치험-증례보고-)

  • 이해원;김관민
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.340-343
    • /
    • 1997
  • We experienced a female patient with intramural hematoma of the aorta. This patient had a severe anterior chest pain radiating to interscapular area with choking sensation. CT revealed a intramural hematoma of the thoracic aorta and a part of the abdominal aorta but there was no evidence of intimal tearing. We did the eme gency operation under hypothermic circulatory arrest and retrograde cerebral perfusion. Ascending aorta was replaced and coronary artery bypass graft was done because of intimal tearing of the ostium of right coronary artery. She was discharged without any significant complication. We reported this case with consideration about necessity of emergency operation for intramural hematoma of the thoracic aorta.

  • PDF

Development of a Enamel Coating Machine Typed VOC Incineration and Flue Gas Recirculation (VOC 소각 및 연소가스 재 순환 에나멜 도장장치 개발)

  • 정남조;유인수;유상필;송광섭
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.579-587
    • /
    • 2003
  • A lot of VOCs that is noxious ate exhausted at drying process of enamel coating device. This VOC gas can be incinerated perfectly through catalytic combustion, and heat that is occurred in incineration process ran be again used in drying process. By using VU catalytic combustion technology, in this study, we developed a enamel coating machine that have an excellent environment improvement and energy saying effect. As basic research for this development characteristics ana performance of catalytic combustion for VOC gas was evaluated and numerical analysis for drying oven was calculated. According to the result, VOCs combustion characteristics of metal form catalysis was excellent in high temperature, and it was seen that enamel coating machine should be designed as a precious controllable structure of recirculating supply rate and suction rate.

  • PDF

The Early Results of Open Heart Surgery in Neonates (신생아기 개심술의 조기 성적)

  • Oh, Tak-Hyuck;Kim, Kyu-Tae;Kim, Gun-Jik;Lee, Jong-Tae;Cho, Joon-Yong
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.426-433
    • /
    • 2009
  • Background: Remarkable progress has recently been made in achieving successful early repair of congenital heart disease with using cardiopulmonary bypass in the neonatal period. The aim of this study is to evaluate our short-term outcomes for performing neonatal cardiac surgery under extracorporeal circulation. Material and Method: Fifty five neonates underwent open heart surgery from February 2002 to December 2007. The mean ages and body weight was 13.5 days. and 3.2 kg, respectively. The diagnoses of the patients were transposition of the great arteries (14), total anomalous pulmonary venous connection (7), large ventricular septal defect (VSD) (7), coarotation of the aorta with VSD (6), interrupted aortic arch (5) and others (16). Result: Six patients had difficulties being weaned from extracorporeal circulation. Four patients left the operating room with an open sternum. Low cardiac output syndrome and acute renal insufficiency were observed in 3 patients each, respectively. Post-operative complications were observed in 27 patients (49.1%). The postoperative mortality was 12.7% (7 patients); 5 patients experienced early hospital death and 2 experienced late death (2). Conclusion: In our hospital, early surgical repair with extracorporeal circulation in neonates was feasible with tolerable mortality. Further follow-up required to establish the long-term survival and complications.

A New Recursive Formula to Derive the Fourier Transforms of Cosine-Pulses Using Modified Class-I PRS Model (수정된 제1종 부분 응답 전송 시스템 모델을 이용한 여현 펄스 푸리에 변환의 새로운 순환 공식)

  • 오용선;조형래;강민구;김한종;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.12
    • /
    • pp.1343-1352
    • /
    • 1992
  • This paper presents a new and easy method to obtain the Fourier transforms of the n-th order cosine-pulses whose maximum amplitudes are uniform. The new method is focused on deriving a formula which is recursively related following their orders and can be well applied to some numerical solutions. On the other hand, this method also offers more compact procedures in view of analytical solutions than the conventional methods because the results are consist of the sum of two functions which are easily calculated. Especially, the formula can be represented as a complete recursion by the separation of coefficients originated by the authors and the resulting difference equation is given by the sum of the original 'sinc' functions shifted by some symmetrical factors and multiplied by some constants. The constants are easily decided from the binomial coefficients and the shifting factors from the corresponding exponential differences in the expansion of $(a+b)^n$.

  • PDF

A Study of Zinc Separation from Metal Plating Waste Water using RO Membrane (Membrane을 이용한 도금폐수중 아연이온의 분리에 관한 연구)

  • 장차순;이효숙;정헌생;이원권
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.10a
    • /
    • pp.65-67
    • /
    • 1993
  • 도금공업은 공업기반기술의 하나로서 기계 및 소재산업의 최종 마무리 공정으로 중요시 되고 있으나 운전중 기술의 특성에 의하여 중금속이 함유된 도금폐수를 방출하게 되어 인체 및 생태계에 매우 유해한 산업중의 하나이다. 기존의 도금폐수처리 방븝으로 침전 응집법이 있으나 이는 사용되는 약품의 양이 많고, 슬러지를 배출하여 2차 공해를 유발하므로 완전한 처리 방법이라 할 수 없다. 본 연구에서는 이러한 국내 도금폐수의 현황을 조사한바 도금폐수중 배출양이 가장 많은 아연계폐수를 대상으로 RO Membrane를 사용하여 실험하였다. RO Membrane으로 실험하였을때 아연이온은 Retentate로 분리 농축되고 Permeate는 재생수로 순환 사용할 수 있는 도금폐수의 무배출 처리공정(Zero-Discharge System) 개발을 존 연구의 목적으로 하였다.

  • PDF

The Animal Experiments of Total Artificial Heart at the National Cardiovascular Center in Japan (일본국립순환기병센터형 완전 인공심장을 이용한 동물실험)

  • 박영환
    • Journal of Chest Surgery
    • /
    • v.27 no.10
    • /
    • pp.824-832
    • /
    • 1994
  • Recently we developed the concept of totally implantable electrohydraulic artificial heart. We tested the artificial heart which was drived by external compressive air in the calves. All three calves had pneumonia before surgery, so postoperative course was not only bad but also the results was not good. The first calf died severe pneumonia on 76th day, the second calf died from troublesome bleeding and uncertain allergic like reaction, and the third died because of bleeding. However, the performance of the artificial heart was good, and especially the blood contacting surface showed excellent hemocompatibility. The anatomic fitting was also very good even in the 35 Kg small newborn calf. During treadmill test, the first calf did not well tolerate for 1 minute but by the Full Fill Full Empty control method the artificial heart responsed well to the physiologic needs. In conclusion, the artificial heart had the very good hemocompatible surface, however, the volume of the artificial heart was a little deficient for the calf and the control algorithm needed further development.

  • PDF

A Study on the Practical Estimation of Nonlinear Hemodynamic Variables for the Moving-Actuator type Total Artificial Heart (인공심장의 비선형 혈류 역학 변수 예측에 관한 연구)

  • 엄경식;안재목
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 1998
  • It is needless to say that the nonlinear hemodynamic variables estimation is a very important study for the artificial heart. Even though it is important, there have not been satisfactory results which can be applied to the real world situations, In this paper, the problem of hemodynamic variables estimation for the moving-actuator type total artificial heart(MA-TAH) was studed. Multidimensional linear interpolation(MDI)scheme was used for the estimation. Proposed method was verified by in vitro test and showed good performance.

  • PDF

Clinical Result of Aortic Arch Replacement using Antegrade Brain Perfusion Via Right Axillary Artery (우액와동맥을 통한 순행성 뇌관류법을 이용한 대동맥궁 치환의 임상성적)

  • Kim, Dong-Jin;Na, Yong-Jun;Jeong, Dong-Seop;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.25-31
    • /
    • 2007
  • Background: Cerebral protection is one of the most important procedures during aortic arch surgery. We can minimize neurological complications through short period of total circulatory arrest and resuming of brain perfusion. We evaluated 11 patients who underwent arch replacement using antegrade brain perfusion via right axillary artery. Material and Method: Between July 2004 and July 2006, 11 patients (male 9, female 2) underwent aortic arch replacement with antegrade brain perfusion via right axillary artery. Preoperative diagnosis was listed; 5 type A aortic dissections (5/11, 45.5%), 5 aortic aneurysms (5/11, 45,5%) and 1 type A IMH (intramural hematoma, 1/11, 9%). The mean age at the time of operation was $60.3{\pm}12.8$ years. For antegrade brain perfusion, we performed right axillary artery cannulation in all patients. Retrograde brain perfusion was used briefly during total circulatory arrest. Result: The mean total circulatory arrest time was $31.1{\pm}16.9$ minutes and the mean retrograde brain perfusion time was $21{\pm}17.8$ minutes. Mean antegrade brain perfusion time was $77.9{\pm}17.5\;(43{\sim}101)$ minutes. We had neither operative mortality nor permanent neurological complications. Conclusion: By means of antegrade brain perfusion via right axillary artery, that could lead to decrease circulatory arrest time and minimize damages to severely atheromatous arch vessels, we can expect to reduce neurological complications after aortic arch replacement. Further investigation with iarge patient populations will be required.