• 제목/요약/키워드: 온열쾌적도

검색결과 151건 처리시간 0.027초

여름철 공조시스템의 최적 운전 제어 방식 (Optimal air-conditioning system operating control strategies in summer)

  • 허정호
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.410-425
    • /
    • 1997
  • Buildings are mostly under part load conditions causing an inefficient system operation in terms of energy consumption. It is critical to operate building air-conditioning system with a scientific or optimal manner which minimizes energy consumption and maintains thermal comfort by matching building sensible and latent loads. Little research has been performed in developing general methodologies for the optimal operation of air-conditioning system. Based on this research motivation, system simulation program was developed by adopting various equipment operating strategies which are energy efficient especially for humidity control in summer. A numerical optimization technique was utilized to search optimal solution for multi-independent variables and then linked to the developed system simulation model within a mam program. The main goal of the study is to provide a systematic framework and guideline for the optimal operation of air-conditioning system focusing on air-side. For given cooling loads and ambient outdoor conditions the optimal operating strategies of a commercial building are determined by minimizing a constrained objective function by a nonlinear programming technique. Desired space setpoint conditions were found through evaluating the trade-offs between comfort and system power consumption. The results show that supply airflow rate and compressor fraction play main roles in the optimization process. It was found that variable setpoint optimization technique could produce lower indoor humidity level demanding less power consumption which will be benefits for building applications of humidity problem.

  • PDF

한국인의 온열쾌적감 및 생리신호에 관한 연구 ( Part II : 여름철 체감실험 결과 ) (Experimental Study on Thermal Comfort Sensation of Korean and Physiological Signal Part II : Analysis of Subjective Judgement in Summer Experiment)

  • 김동규;주익성;금종수;최광환;최호선;이길랑
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1997년도 한국감성과학회 연차학술대회논문집
    • /
    • pp.113-117
    • /
    • 1997
  • 본 논문은 여름철 체감실험에 대한 결과이다. 유니폼을 착용한 각 피험자(중학생, 대학생, 고령자)는 90분동안 환경시험실에 체재하면서 의자에 앉아 전신온냉감 및 쾌불쾌감을 신고하였다. 체감실험동안 피부온도는 인체의 3곳에서 측정하였고 피험자는 10분 간격마다 전신온냉감 및 쾌불쾌감을 신고하였다. 환경물리량및 인체 피부온도는 매 20초 간격으로 측정하였다. 여름철 체감실험 결과 아래의 결론을 얻었다. 1)평균피부온도가 증가함에 따라 TSV는 선형적으로 능가하며 열적으로 중립감을 느낄 때으리 평균피부온도는 고령자의 경우 남자 33.8$^{\circ}C$, 여자 34.3$^{\circ}C$이고, 대학생 남자의 경우 34.1$^{\circ}C$ ,여자 33.8$^{\circ}C$, 중학생의 경우는 34.4$^{\circ}C$이다. 2)발한량과 평균피부온도의 관계는 각 계층 모두 평균피부온도 34$^{\circ}C$를 전후로 급격히 상승함을 알 수 있다. 3)전신온냉감이 중립일 경우 고령자 남자의 SET*=25.6$^{\circ}C$, 고령자 여자 28.4$^{\circ}C$, 대학생 남자 26$^{\circ}C$, 대학생여자 26.9$^{\circ}C$, 중학생 27.1$^{\circ}C$이었다.

  • PDF

액체흡수제 이용 태양열 공조시스템의 하계 능력에 관한 연구 (Research on the Performance of a Solar Air Conditioning System using a Liquid Desiccant in Summer)

  • 최광환;윤정인;김보철
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.33-38
    • /
    • 2002
  • In order to find out whether solar air conditioning system could be applied to building or not, the performance and evaluation on thermal environment of the system suggested was done during summer. A solar model house was constructed to find out the performance and thermal environment evaluation when it actually operated outside. As a result, regeneration rate increased rapidly when LiCl solution temperature was over $50^{\circ}C$ and the regeneration rate was $13\sim15kg$ during 9 hours operation. Furthermore the dehumidification rate was 12kg at maximum during 10 hours operating of a dehumidifier and indoor temperature and relative humidity was $28.4^{\circ}C$ and 39.1% in average respectively. On evaluation of thermal environment during summer, PMV value was slightly high, but thermal sensation vote was 71% within the comfort zone.

다중회귀분석을 통한 PMV 모델의 단순화 (Simplification of PMV through Multiple Regression Analysis)

  • 문용준;노광철;오명도
    • 설비공학논문집
    • /
    • 제19권11호
    • /
    • pp.761-769
    • /
    • 2007
  • The purpose of this study is to present a simplified model of predicted mean vote (PMV) using multiple regression analysis. We performed the experiments and the numerical calculations in the lecture room during summer and winter to simplify PMV. And the multiple regression analysis on PMV was conducted to estimate the contribution of independent variables toward PMV. From the multiple regression analysis, we found that the effect of independent variables on PMV followed in order, clo value>air temperatur>air velocity>mean radiant temperature>relative humidity. And the simplified PMV was proposed through a few assumptions and then was compared with original PMV. They had a good agreement with each other. Additionally, we compared the simplified PMV with EDT. We expected that the simplified PMV can be more useful than EDT to evaluate the thermal comfort in the place, where radiation is dominant. But the comfort range of the simplified PMV should be adjusted to predict the exact thermal comfort in the future.

이중 윅 타입 히트파이프를 이용한 바닥복사패널의 난방특성 연구 (A Study on the Heating Characteristics of Radiant Floor Panel Using Heat Pipes with the Double Wick)

  • 김용기;이태원
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.183-189
    • /
    • 2012
  • Most of the domestic residential buildings have used the traditional radiant heating system, circulating hot water through the cross-linked polyethylene(PE-X) pipe buried in the floor panel of the heating space. New type of the heating panel was recently developed using heat pipes with double wicks. Some experiments were carried out in this study to verify the thermal characteristics of this heating system at the unit heating space which surrounded by outer space whose temperature of air be maintained scheduled value with time. Through the various experiments with several parameters, such as flow rate, inlet and outlet temperatures of hot water and the heating duration and so on, we found that the floor heating system with heat pipes was able to reduce the pumping power for hot water circulation by 4~31% compared with the conventional panel heating system using PE-X pipe. These results could be used for optimal design and efficient operation of the heating system as well as improvement of thermal comfort.

자동차 에어컨 쾌적제어 알고리즘 개발을 위한 운전자 온열감성 평가 : 제 1 보-운전자의 에어컨 조작 선호도 (Comfort Control Algorithm Development of Car Air Conditioner using Thermal Comfort Evaluation of Driver : Part I - Air-conditioning Operating Preference of Driver)

  • 김민수;김동규;이기덕;금종수
    • 설비공학논문집
    • /
    • 제26권6호
    • /
    • pp.294-300
    • /
    • 2014
  • In this study, we investigated and evaluated the air conditioning operation of the driver according to the temperature difference between the inside and outside of a car parked outside during the summer. We suggest including a comfort mode to the car air conditioning system to improve the thermal comfort of the driver, in which the comfort can be maintained for a longer time. For the a result of our experiment, in the cases with temperature of above $45^{\circ}C$ inside of the car, the subjects preferred strong air blow with the face and the arms in the direction of the blow. In the cases with temperature of below $40^{\circ}C$ inside of the car, the subjects preferred lower volume of air blow. In the temperature below $28.1^{\circ}C$ inside of the car, the mean temperature on the skin of the driver reached the comfort zone.

온도변동에 따른 인체 생리적 반응 -제2보: 맥파를 중심으로- (Physiological Response of Human Body by Temperature Change -Part 2: In Priority to Pulse wave-)

  • 강석중;금종수;김동규;정용현;이낙범
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.23-28
    • /
    • 2007
  • In most existing research, it is difficult to evaluate thermal comfort exactly because of reflecting individual ideal or psychological response by subjective questions. Physiological variable was selected in this study to evaluate objectively thermal comfort. MST was appeared very sensitively in indoor temperature and can express correctly thermal comfort of human body. The results of CSV are different each individual feeling sensation, so is difficult to evaluate detailedly thermal comfort unlike TSV. But the results of PP, AIx, ED, SEVR are greatly related to temperature change. So thermal comfort is evaluated more objectively by using PP, AIx, ED, SEVR on behalf of TSV, CSV. Human body was presented physiological feedback by temperature impetus and specially, tendency of heart rate agree with temperature change. Physiological reaction was showed sufficient possibility availing evaluation index of thermal comfort. In the future another one needs to review beside the selected physiological variable.

  • PDF

여름철 수면시 온열쾌적감 평가 - 제3보 : 실내온도 상승에 관하여 - (Evaluation of Thermal Comfort during Sleeping in Summer - Part III : About Indoor Air Temperatures Rise -)

  • 김동규;금종수;김세환
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.535-540
    • /
    • 2006
  • This study was performed In evaluate sleep efficiencies and conditions for comfortable sleep based on the analysis of Physiological signals under variations in thermal conditions. Five female subjects who have similar life cycle and sleep patterns were participated for the sleep experiment. It was checked whether they had a good sleep before the night of experiment. EEGs were obtained from C3-A2 and C4-A1 electrode sites and EOGs were acquired from LOC (left outer canthus) and ROC (right outer canthus) for REM sleep detection. Sleep stages were classified, then TST (total sleep time), SWS (slow wave sleep) latency and SWS/TST were calculated for the evaluation of sleep efficiencies on thermal conditions. TST was defined as an amount of time from sleep stage 1 to wakeup. SWS latency was from light off time to sleep stage 3 and percentage of SWS over TST was calculated for the evaluation of sleep quality and comfort sleep under thermal conditions. As result, the condition which raise a room temperature provided comfortable sleep.

바닥 복사 난방시 바닥온도와 거주자 자세 변화에 따른 인체 반응에 관한 연구 (The Study of Human Response for Floor Surface Temperature and Resident's Posture Change)

  • 김동규;김세환
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.846-851
    • /
    • 2012
  • The radiant floor heating system is traditional heating system in korea. Radiant floor heating is small in vertical temperature difference, air stream and radiant heat distribution is uniform. And radiant floor heating system provide thermal comfort conditions to the a resident. This study was undertaken to evaluate the physiological-subjective responses of the resident's posture change such as sitting and standing. The experimental investigations were carried out in climate chamber, and subjects were 4 college-age students in good health. The physiological response was skin temperature and subjective response was undertaken survey of TSV and CSV. The results were summarized as follows; The comfortable temperature range of plantar surface was $35.1{\sim}38.9^{\circ}C$ and buttock surface was $37.8{\sim}39.3^{\circ}C$.

한랭환경하에서 인체의 국소가온 자극이 온열생리.감각반응에 미치는 영향 (Physiological and Psychological Thermal Responses to Local Heating of the Human Body in a Cold Environment)

  • Shin, Jounghwa
    • 한국의류학회지
    • /
    • 제25권10호
    • /
    • pp.1745-1753
    • /
    • 2001
  • 본 연구는 한랭 환경 하에서의 인체의 국소 가온 자극이 생리, 감각반응에 끼치는 영향을 검토했다. 건강한 성인여자 7명을 대상으로, 기온 $25^{\circ}C$, 습도50%의 환경 하에서 균일한 국소 가온을 부하 했을 때 피부온, 고막온, 손가락, 발가락 혈류량, 온냉감, 쾌적감의 반응에 미치는 영향을 검토한 결과는 다음과 같다. 1) 국소가온에 의해 가온 부위 피부온은 유의하게 상승하고 가온 부위에 따라 상승도에는 유의한 차가 보였다. 2) 국소가온에 의해 고막온은 머리의 가온 시에 높은 상승, 전완의 가온 시에 상승하고, 다른 가온 부위에서는 하강의 경향이 보였다. 3) 국소가온에 의해 혈류량의 변화는 3개의 군으로 분류된다. 가온과 함께 손가락 혈류량이 증가하는 군, 발가락 혈류량이 변화하는 군, 양쪽의 혈류량이 적게 변화하는 군으로 나누어진다. 이것을 각 피험자의 평균 피부온 수준 즉 체온조절 수준과 관계 있는 것으로 논할 수 있다 4)국소 가온에 의해 각 부 위 피부온으로의 파급효과는 머리, 상완의 가온 시에 크지만 대퇴, 하퇴 다리의 가온 시에는 대부분의 부위에서 영향이 보이지는 않았다. 5) 이와 같이 국소 가온에 의 한 생리, 감각반응은 가온 부위에 따라 다르고 머리, 상완의 가온 시에는 생리반응이 크고 하퇴, 다리의 가온시에는 국소의 감각변화가 컸다.

  • PDF