• Title/Summary/Keyword: 온도 측정

Search Result 9,409, Processing Time 0.035 seconds

Measurement of Wax Appearance Temperature Using Image Processing (영상 처리기법을 이용한 오일의 왁스생성온도 측정)

  • Hwang, Soon-Hye;Kang, Pan-Sang;Lim, Jong-Se
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • When the oil is produced in the low temperature environment, wax can be accumulated in petroleum production system(pipeline, riser) and causes problems such as pipeline stucking, disturbance of the oil production. These problems can be lead to time-consuming and economic losses for flow assurance. For prediction and mitigation of wax deposition, it is necessary to measure the Wax Appearance Temperature(WAT) which is a temperature when the wax crystals start to be formed. WAT standard measurement method of transparent oil has to determine the cloud point of sample to the naked eye and cannot be applied to continuous change of the temperature. In this study, wax behavior of transparent oil samples are recorded depending on temperature using Visualized WAT Measurement System. Also, WATs of transparent oil samples are measured by image processing and compared with the result of the standard method.

Thermal Resolution Analysis of Lock-in Infrared Microscope (위상잠금 열영상 현미경의 온도분해능 분석)

  • Kim, Ghiseok;Lee, Kye-Sung;Kim, Geon-Hee;Hur, Hwan;Kim, Dong-Ik;Chang, Ki Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • In this study, we analyzed and showed the enhanced thermal resolution of a lock-in infrared thermography system by employing a blackbody system and micro-register sample. The noise level or thermal resolution of an infrared camera system is usually expressed by a noise equivalent temperature difference (NETD), which is the mean square of the deviation of the different values measured for one pixel from its mean values obtained in successive measurements. However, for lock-in thermography, a more convenient quantity in the phase-independent temperature modulation amplitude can be acquired. On the basis of results, it was observed that the NETD or thermal resolution of the lock-in thermography system was significantly enhanced, which we consider to have been caused by the averaging and filtering effects of the lock-in technique.

Optical methods for Particle Size and Temperature Measurements (입자크기 및 온도측정을 위한 광학적 방법)

  • 김상수;서용재
    • Journal of the KSME
    • /
    • v.33 no.12
    • /
    • pp.1069-1075
    • /
    • 1993
  • 측정기술이 발달함에 따라 실제 연소시스템에서 직접 응용할 수 있고, 시공간적으로 해상도가 높고 유동장과 온도장을 교란하지 않는 방법이 요구되고 있다. 이 글에서는 2장에서 광학적 방 법을 이용한 입자의 크기 측정법을 살펴보고, 3장에서는 광학적 방법을 이용한 온도의 측정법에 대하여 설명하고자 한다.

  • PDF

단일 밴드 중적외선 영상을 이용한 표면온도 추정 방법 연구

  • Park, Uk;Lee, Yun-Gyeong;Won, Jung-Seon;Lee, Seung-Geun;Kim, Jong-Min
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.125-130
    • /
    • 2008
  • Mid-Infrared (MIR) 영상은 화산 활동 및 산불로 인한 재난관측, 지표물질 관측, 해수 온도 측정과 같은 분야들에서 사용되고 있다. 그러나 MIR영역은 지표의 복사율과 대기의 영향으로 인한 변화가 매우 심하고, 낮 영상의 경우 태양 복사량에 의한 영향도 고려해야 하는 어려움이 있다. 따라서 단일밴드인 MIR영상을 이용하여 표면온도를 얻기 위해서는 영상이 취득된 시간과 장소에서 관측된 태양 복사량 및 여러 가지 대기 변수가 필요하다. 본 연구의 목적은 기존의 MIR 영상 연구가 다중밴드를 기반으로 한 것과 달리 단일 밴드의 영상을 이용하여 표면온도를 측정하는데 있다. 이를 위하여 MODIS MIR 영상을 대상으로 MODTRAN을 사용하여 MIR 영역의 대기보정 기법을 적용 한 뒤 복사전달 모델을 이용하여 지표의 복사량을 측정하였다. 획득된 지표온도 영상의 정밀도를 측정하기 위해서 기존의 온도 알고리즘인 split-window algorithm에 의해 얻어진 해수온도 영상과의 비교를 통하여 오차 원인에 대해 분석을 실시하였다. 그 결과 낮 영상의 경우 -4.19${\pm}$1.19$^{\circ}C$ 정도의 온도 차가 났으며, 밤 영상의 경우 0.5$^{\pm}C$0.39$^{\circ}C$ 정도로 비교적 좋은 결과를 보였다. 이는 낮 영상의 경우 지표의 복사율에 대한 온도의 민감도가 매우 높기 때문에 높은 오차가 발생하지만, 밤 영상의 경우 태양빛에 의한 영향이 없으므로 좋은 결과를 나타내기 때문이다. 따라서 단일밴드 MIR영상을 이용한 지표온도 추정 시 대기에 의한 영향보다 지표 복사율에 의한 영향이 높다고 추정할 수 있다.

  • PDF

Development of Thermocouple Sensor for Thermal Boundary Layer Measurement (온도 경계층 측정용 열전대 센서 개발)

  • Seo, Jongbeom;Han, S.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.983-990
    • /
    • 2014
  • This research focused on designing an appropriate thermocouple sensor for a thermal boundary layer with a large temperature gradient. It was designed to minimize the conduction error from a constant temperature wall in a boundary layer. A $79.9-{\mu}m$ thermocouple was chosen, and a five-axis device jig was developed to fabricate a butt-welded thermocouple, which is different from arc-welded junction thermocouples. This was used to minimize the size of the thermocouple junction. In addition to fabricating butt-welded thermocouples, a thorough calibration was conducted to decrease the internal error of a multimeter to ensure that the data from the butt-welded and regular thermocouples were almost the same. Based on this method, a butt-welded thermocouple with a small junction was found to be suitable for measuring the temperature in a thermal boundary layer with very large thermal gradients. Using this thermal boundary layer probe, the thermal boundary layers in a turbine cascade were measured, and the Nusselt numbers were obtained for the turbine endwall.

CIGS박막 태양전지소자의 온도변화에 따른 전기적 특성 분석

  • Kim, Sun-Gon;Kim, Sang-Seop;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.224.2-224.2
    • /
    • 2013
  • 본 연구에서는 CIGS박막 태양전지의 온도 및 시간 인가에 따른 전기적 특성 변화를 분석하였다. 실험에서는 온도 스트레스를 $25^{\circ}C$, $50^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$, $200^{\circ}C$에서 각각 10시간씩 인가한 후에 Dark I-V와 C-V측정을 통해 전기적 특성 변화를 분석하였다. $25^{\circ}C$일 때를 초기 온도로 하여 특성을 측정한 것과 온도별로 노출시킨 후에 측정한 것을 비교했을 때 소자의 효율은 $100^{\circ}C$에서 감소하기 시작하였고, 인가한 온도가 높을수록 점점 많이 감소하는 모습이 나타났다. 이와 비슷하게 I-V그래프와 C-V그래프의 모습도 초기 값과 비교해서 변화하는 모습이 나타났고, 온도가 높아질수록 점점 변화하는 양이 증가하였다. I-V그래프에서 Diode ideality factor는 온도변화에 따라 초기 값 대비 증가하는 모습이 나타났다. 온도에 노출되기 전보다 노출된 후에 current와 capacitance가 감소하는 경향을 보이는데, 이는 온도의 영향으로 인해 소자의 결함이 증가하여 전하들의 반응에 영향을 주었기 때문으로 판단된다.

  • PDF

Prediction of a rectal temperature utilizing a thermal perception index (열감지지수를 활용한 신체온도의 예측)

  • ;Jerry D. Ramsey
    • Science of Emotion and Sensibility
    • /
    • v.1 no.2
    • /
    • pp.75-79
    • /
    • 1998
  • 이 논문은 신체온도를 직접 측정하지 않고서 신체온도를 예상하는 모델을 연구한 것이다. 열감지지수 (TPI)를 개발하여 환경으로부터 느끼는 체감온도와 몸의 내부온도인 직장온도(Trec)와 몸의 외부온도인 피부온도 (Tsdin)를 예측하도록 하였다. Kwon과 Ramsey의 개발모델을 Goldman 의 모델과 비교해본 결과 정확도에 통계적으로 유의한 차이가 없었다. 회귀분석과 경험을 토대로 만든 체감온도를 예측할 수 있는 손쉬운 Kwon의 열감지지수 (KTPI)도 제시하였다. 대부분의 사람들이 쉽게 예측할 수 있도록 측정 또는 사용가능한 몇 개의 환경변수로부터 쉽게 몸의 예산 내부온도와 외부온도를 계산할 수 있게 단순화하였다.

  • PDF

Analysis of Junction Temperature Measurement in 20W Module for Street Lighting (20W 가로등 모듈의 접합온도 측정 분석)

  • Lee, Se-Il;Yang, Jong-Kyung;Kim, Nam-Goon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.163-163
    • /
    • 2010
  • 기존 LED의 접합온도 및 열저항은 PKG 단계에서 측정 가능 하였다. PKG에서의 접합온도 측정방식과 같은 방법으로 C사의 1W High Power LED XP2 20개를 직렬 연결하여 모듈을 구성한 20W 가로등 모듈에 대하여 접합온도를 측정 하였다. 측정결과 20W 가로등 모듈의 접합온도는 약 $61^{\circ}C$로 나타났다.

  • PDF

KSTAR 전자 사이클로트로 방출(ECE) 진단계

  • Jeong, Seung-Ho;Lee, Gyu-Dong;Kogi, Y.;Kawahata, K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.411-411
    • /
    • 2011
  • KSTAR 토카막 플라즈마의 전자온도 측정을 위한 전자 사이클로트론 방출(ECE) 진단계가 완성되어 KSTAR 3차 운전기간 동안 전자온도를 측정하였다. ECE 진단계는 2단의 헤테로다인 수신기 2개와 75채널의 RF 검출기 그리고 비디오 증폭기로 이루어져있다. 2개의 헤테로다인 수신기의 주파수 범위는 각각 110 GHz~162 GHz, 164 GHz~196 GHz 이며 163 GHz multiplexer에 의해 ECE power를 나눠갖는다. 각 채널 사이의 주파수 간격은 1 GHz이며 토로이달 자장을 2.5T로 운전한다면 플라즈마 반경방향의 모든 위치에서 측정이 가능하다. 또한 시간분해능도 100 kHz로 우수하여 반경방향의 전자온도분포의 시간 변화를 측정할 수 있다. 이 포스터에서는 2010년 KSTAR 실험동안 반경위치에 대한 전자온도를 측정과 sawtooth, ELM 등 MHD 현상 관측 결과에 대해 발표하였다. 그리고 중성빔(NB) 가열을 하는 동안 나타난 H-mode 때 전자온도의 변화도 살펴보았다.

  • PDF

Estimation of Cooling Rate in Bulk Amorphous Alloys by Separate Cooling Process

  • Kang, Bok-Hyun;Choi, Seong-Pil;Kim, Ki-Young
    • Journal of Korea Foundry Society
    • /
    • v.30 no.5
    • /
    • pp.167-173
    • /
    • 2010
  • 벌크 비정질 합금의 특성상 점도가 높고, 냉각속도가 빨라 냉각되는 합금의 온도를 직접 측정하는 것은 곤란하므로, 측정에 의하여 냉각속도를 구하는 것은 매우 어렵다. 본 연구에서는 합금의 온도를 직접 측정하는 대신 금형의 온도를 측정하고, 측정된 금형의 온도를 상용 열해석 프로그램을 이용한3차원 계산 결과와 비교, 보정하는 역문제 기법을 사용하여 Cu계와 Zr계 벌크 비정질합금의 냉각속도를 예측하였다. 예측된 냉각속도는 금형온도와 시편의 두께에 따라Cu계의 경우는 284~300 K/s, Zr계는 279~289 K/s로, 초기 금형온도의 영향은 크지 않은 것으로 나타났다. 전산모사 결과와 달리 금형을 수냉한 쪽보다 가열한 쪽의 응고중 냉각속도가 빨라 조직이 더 미세한 것으로 나타났는데, 이는 응고중 금형과 주물간에 에어갭의 형성으로 열전달을 방해 받은 영향으로 사료된다.