• Title/Summary/Keyword: 온도 보상

Search Result 417, Processing Time 0.032 seconds

Design of Over Current Sequence Control Algorithm According to Lithium Battery Fuse Temperature Compensation (리튬 배터리 퓨즈 온도 보상에 따른 과전류 시퀀스 제어 알고리즘 설계)

  • Song, Jung-Yong;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.1
    • /
    • pp.58-63
    • /
    • 2019
  • Lithium-ion batteries used for IT, automobiles, and industrial energy-storage devices have battery management systems (BMS) to protect the battery from abnormal voltage, current, and temperature environments, as well as safety devices like, current interruption device (CID), fuse, and vent to obtain positive temperature coefficient (PTC). Nonetheless, there are harmful to human health and property and damage the brand image of the manufacturer because of smoke, fire, and explosion of lithium battery packs. In this paper, we propose a systematic protection algorithm combining battery temperature, over-current, and interconnection between protection elements to prevent copper deposition, internal short circuit, and separator shrinkage due to frequent and instantaneous over-current discharges. The parameters of the proposed algorithm are suggested to utilize the experimental data in consideration of battery pack operating conditions and malicious conditions.

Temperature Compensation of Nondispersive Infrared Gas Senor: Infrared Light Absorbance (비분산 적외선 가스 센서 온도 보상법: 적외선 흡수도)

  • Yi, SeungHwan
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.36-41
    • /
    • 2021
  • The motivation of this paper is to easily analyze the properties of nondispersive infrared gas sensor that has more than two different optical path length and to suggest the criterion and definition of infrared light absorbance in order to minimize the measurement errors. With the output voltage ratios and the normalized derivatives of infrared ray (IR) absorbance, when the normalized derivatives of IR absorbance decreases from 0.28 to 0.10, the lower and higher limits of errors were decreased from -5.62% and 2.39% to -4.27% and 2.78%. When the normalized derivatives of IR absorbance were 0.10, the output voltage could be partitioned into two regions with one exponential equation and the temperature compensation error was less than 5%.

Relation between Changes of DITI and Clinical Results according to the Level and Extent of Sympathicotomy in Essential Hyperhidrosis (본태성다한증에서 흉부교감신경의 차단 범위와 부위에 따른 임상결과와 체열변화 사이의 관계)

  • 최순호;임영혁;이삼윤;최종범
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.64-71
    • /
    • 2004
  • Background: Video-assisted sympathicotomy is a safe and effective method for the treatment of essential hyperhidrosis with immediate symptomatic improvement. However, this is offset by the occurrence of a high rate of side-effects, such as embarrassing compensatory hyperhidrosis. Therefore, by comparing and assessing the relationship between temperature change measured by DITI (digital infrared thermographic imaging) and clinical results according to the level and extent of sympathicotomy in essential hyperhidrosis. we tried to obtain a more precisely and objectively, the distribution and degree of compensatory sweating by DITI and also for ascertaining the clinical usefulness. Material and Method: From January 2000 to June 2002, the thoracoscopic sympathicotomy was performed in 28 patients suffering from essential hyperhidrosis in Dept. of Thoracic and Cardiovascular Surgery, Wonkwang University Hospital. The patients were divided into four groups, Group I: patients having undergone T2 sympathicotomy, Group II: patients having undergone T3 sympathicotomy, Group III: patients having undergone T3,4 sympathicotomy, and Group IV: patients having undergone T2,3,4 sympathicotomy. The parameters were composed of the satisfaction rate of treatment, the degree of compensatory and plantar sweating, and temperature changes of entire body measured by DITI Result: There was no difference in age and follow-up period among the groups. All of the treated patients obtained satisfactory alleviation of essential hyperhidrosis in immediate postoperative period. However, the rate of long-term satisfaction were 85.8%, 85.8%, 42.9%, and 28.6% in group I, II, III, and IV (p<0.05). More than embarrassing compensatory sweating was present in 14.2%, 14.2%, 57.1%, 71.4% in group I, II, III, and IV (p<0.05) In regard to plantar sweating, decrease in sweating was expressed in each of four groups, but was not significant between groups. An apparent increase of temperature measured by DITI indicated sufficient denervation and predicted long-lasting relief of essential hyperhidrosis and also decrease in temperature of trunk and lower extremity by DITI had correlated well with postoperative satisfaction, and also postoperative compensatory sweating. Conclusion: We suggested that the incidence and degree of compensatory sweating was closely related to the site and the extent of thoracic sympathicotomy. Resection of the lower interganglionic neural fiber of the second thoracic sympathetic ganglion on the third rib is the most practical and minimally invasive treatment than other surgical methods. We were also to anticipated the distribution and degree of compensatory sweating by DITI precisely and objectively and for ascertaining the clinical usefulness.

The EMI Noise Reduction Circuit with Random Number Generator (랜덤 수 생성 회로를 이용한 EMI Noise 저감 회로)

  • Kim, Sung Jin;Park, Ju Hyun;Kim, SangYun;Koo, Ja Hyun;Kim, Hyung il;Lee, Kang-Yoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.9
    • /
    • pp.798-805
    • /
    • 2015
  • This paper proposes Relaxation Oscillator with Random Number Generator to minimize electromagnetic interference (EMI) noise. DC-DC Converter with Relaxation Oscillator is presented how much spurious noise effects to RF Receiver system. The main frequency of the proposed Relaxation oscillator is 7.9 MHz to operate it and add temperature compensation block to be applied to the frequency compensation in response to temperature changes. The DC-DC Converter Spurious noise is reduced up to 20 dB through changing frequency randomly. It is fabricated in $0.18{\mu}m$ CMOS technology. The active area occupies an area of $220{\mu}m{\times}280{\mu}m$. The supply voltage is 1.8 V and current consumption is $500{\mu}A$.

Thermoplastic Film Infusion Process for Long Fiber Reinforced Composites Using Rubber Expandable Tools (고무 치공구와 필름 함침공정을 이용한 열가소성 장섬유 복합재료 성형공정 연구)

  • Kim, Dong-Wook;An, Young-Sun;Lee, Young-Kwan;Kim, Seong-Woo;Nam, Jae-Do
    • Polymer(Korea)
    • /
    • v.25 no.1
    • /
    • pp.122-132
    • /
    • 2001
  • Thermoplastic film infusion process was investigated by using a rubber tool, which intrinsically contains a thermally-expandable characteristic and effectively compensates for the pressure loss caused by thermoplastic polymer infusion. Increasing temperature up to the melting temperature of matrix, the polymer melt subsequently infused into the dry fabric, but the pressure was successfully sustained by the rubber tool. Even with the decreased resin volume, the rubber tool produced sufficiently high elastic force for continuous resin infusion. Combining D'Arcy's law with the compressibility of rubber tool and elastic fiber bed, a film infusion model was developed to predict the resin infusion rate and pressure change as a function of time. In addition, the film infusion process without the rubber tool was viewed and analyzed by a compression process of the elastic fiber bed and viscous resin melt. The compressibility of fiber bed was experimentally measured and the multiple-step resin infusion was well described by the developed model equations.

  • PDF

Highly Stable RF Transfer over a Fiber Network by Fiber-induced Phase Noise Cancellation (위상잡음 제거에 의한 광섬유망에서의 높은 안정도의 RF 전송)

  • Lee, Won-Kyu;Yee, Dae-Su;Kim, Young-Beom;Kwon, Taeg-Yong
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.6
    • /
    • pp.514-518
    • /
    • 2006
  • We have transferred highly stable 100 MHz RF through a 23 km fiber network. The fiber-induced phase noise due to the vibration and the temperature fluctuation in the optical path is detected and is compensated by configuring a noise-canceling servo. The transfer instability was $6{\times}10^{14}$ at 1 s of averaging time and $2{\times}10^{-17}$ at 10000 s of averaging time. The single sideband phase noise was greatly reduced by more than 20 dB below the Fourier frequency of 1 kHz. The transferred RF has nearly the same stability as the original reference frequency.

Observation and Compensation of Voltage Distortion of PWM VSI for PMSM using Adaptive Control Method (영구자석 동기전동기 구동을 위한 전압원 인버터의 적응제어기법을 이용한 전압 왜곡 관측 및 보상)

  • Kim Hag-Wone;Youn Myung-Joong;Kim Hyun-Soo;Cho Kwan-Youl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.52-60
    • /
    • 2005
  • Generally, a voltage difference or voltage distortion exists between the reference voltage and the practical voltage applied to a motor in a pulse width modulated(PWM) voltage source inverter(VSI). This voltage distortion varies with the operating conditions such as the temperature, DC link voltage, and phase current level. Also the voltage distortion affects the machine current distortion, torque pulsations, and control performance. In this paper, the voltage distortion in a PWM VSI is analyzed and a new on-line estimation method based on the model reference adaptive system(MRAS) is proposed to compensate the time varying voltage distortion, while considering the parameter variations for a permanent magnet synchronous motor (PMSM). The simulation and experimental results show the effectiveness of the proposed voltage difference observer and the compensation method.

Design of Compensated Digital Interface Circuits for Capacitive Pressure Sensor (용량형 압력센서용 디지탈 보상 인터페이스 회로설계)

  • Lee, Youn-Hee;Sawada, Kouji;Seo, Hee-Don;Choi, Se-Gon
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.63-68
    • /
    • 1996
  • In order to implement the integrated capacitive pressure sensors, which contains integrated interface circuits to detect the electrical output signal, several main factors that have a bad effect on the characteristics of sensors must be improved, such as parasitic capacitance effects, temperature/thermal drift, and the leakage current of a readout circuitry. This paper describes the novel design of the dedicated CMOS readout circuitry that is consists of two capacitance to frequency converters and 4 bit digital logic compensating circuits. Dividing the oscillation frequency of a sensing sensor by that of reference sensor, this circuit is designed to eliminate the thermal/temperature drift and the effect of the leakage currents, and to access a digital signals to obtain a high signal-to-noise(S/N)ratio. Therefore, the resolution of this circuit can be increased by increasing the number of the digital bits. Digital compensated circuits of this circuits, except for the C-F converters, are fabricated on a FPGA chip, and fundamental performance of the circuits are evaluated.

  • PDF

Thermodynamic Analysis on the Feasibility of Turbo Expander Power Generation Using Natural Gas Waste Pressure (천연가스 폐압발전 활성화의 당위성에 대한 열역학적 분석)

  • Ha, Jong Man;Hong, Seongho;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.136-142
    • /
    • 2012
  • Thermodynamic equations for the electric power and temperature in a turbo expander generator (TEG) using pressure energy in a natural gas line are derived. From the equations, it was shown that dominant factor is not the pressure difference but the pressure ratio. The high energy level in the inlet of TEG can be made from nearly no expense of electric energy input, which means TEG can be treated as one of newly available clean energy source. If a post heating method is chosen to heat up expanded natural gas, the usage of cold energy is possible without a refrigeration cycle. The combined TEG and refrigeration system enhances economic benefit much more.

Design and Development of Strain Measurement System Based on Zigbee Wireless Network (Zigbee 무선통신 네트워크 기반 변형측정 시스템 설계 및 개발)

  • Kim, Sang-Seok;Park, Jang-Sik;Go, Seok-Jo;Ro, Hee-Jong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.3
    • /
    • pp.585-590
    • /
    • 2012
  • In this paper, a system using vibrating wire sensor and zigbee wireless network has been implemented to monitor and manage the structure. The implemented strain controller drives vibrating wire sensor and computes strain from measuring frequency of the output signal. Temperature sensor is included to compensate strain by temperature. Using two axis acceleration sensor of strain controller can measure the direction of strain or deformation. To measure strain more effectively, wired and wireless communication function is included in this device. As results of experiments, it is shown that the developed system can be effectively applied to measure strain of the structure.