• Title/Summary/Keyword: 온도회복

Search Result 351, Processing Time 0.026 seconds

Analysis on Temperature Change of Ground by Long-term Performance of Energy Pile (수치해석을 통한 에너지 파일의 장기 운용에 따른 지반의 온도변화 분석)

  • Kim, Beom-Jun;Yune, Chan-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.10
    • /
    • pp.5-15
    • /
    • 2019
  • In this study, to investigate the effect of long-term performance of energy pile on ground temperature, a numerical analysis was conducted by simulating the ground where an energy pile was installed. In the analysis, a changing distance from the outer perimeter of a heat circulation pipe to the surface of concrete pile for an intermittent operation (8-hour operation, 16-hour stop) was considered. Simulation results showed that long-term heat exchange under the intermittent operation of energy pile reduced a thermal recovery in the ground and increased the ground temperature through the residual thermal energy. In addition, the ground temperature became higher as it got closer to the energy pile and increased as the distance from the outer perimeter of heat circulation pipe to the surface of concrete pile decreased.

Temperature Dependence of Resistivity in As Implanted LPCVD Polycrystalline Silicon Films (LPCVD로 제조된 다결정실리콘에 As를 주입한 시료의 비저항에 대한 온도의존성 연구)

  • Ha, Hyoung-Chan;Kim, Chung-Tae;Ko, Chul-Gi;Chun, Hui-Gon;Oh, Kye-Hwan
    • Korean Journal of Materials Research
    • /
    • v.1 no.1
    • /
    • pp.23-28
    • /
    • 1991
  • The resistivity of polycrystalline silicon film deposited by low pressure chemical vapor deposition and doped by arsenic Implantation has been investigated as a function of dopant concentration and testing temperature ranging from $25^{\circ}C$ to $105^{\circ}C$ . The resistivity vs. doping concentration curve had a peak point with highest activation energy with respect to the dependence of the resistivity on temperature. We showed that $O_2$ plasma anneal followed by heat-treatment in $N_2$ ambient was able to recover the resistivity degraded by the plasma deposited passivation layers.

  • PDF

A Study on the Regeneration of Ni Catalyst for Hydrogenation(II) (수소첨가반응용 니켈 폐촉매의 활성재생에 관한 연구 (II))

  • Kim, Jung-Hun;Lee, Gun-Dae;Lee, Ho-In
    • Applied Chemistry for Engineering
    • /
    • v.2 no.1
    • /
    • pp.47-55
    • /
    • 1991
  • Regeneration of carbon-deposited Ni catalyst used for hydrogenation reaction was studied. Deposited carbon was removed by oxidation with various concentrations of oxygen. Activity of the catalysts was tested on aniline hydrogenation as a model reaction. When a carbon-deposited catalyst was treated under oxygen atmosphere, the specific surface area of the catalyst increased and then decreased with the increase of treatment temperature. The treatment temperature which gives maximum specific surface area increased with the decrease of oxygen concentration. Pore size of the support was decreased and sintering of nickel particles was more significant with the increase of oxygen concentration. The catalyst treated under 5 % oxygen concentration recovered its catalytic activity up to 90 % of the initial value, but the treatment under 20 % oxygen concentration gave no significant increase of the catalytic activity. Catalytic activity increased with treatment time when the catalyst was treated under 5 % oxygen concentration, but nearly constant after 1 hour.

  • PDF

Temperature Sensitivity of Sigma Background Is Suppressed by the Disruption of ScKNS1 in Saccharomyces cerevisiae (ScKns1 결손에 의한 Saccharomyces cerevisiae ${\Sigma}1278b$ 균주의 온도 민감성 억제 효과)

  • Park, Yun-Hee;Park, Hee-Moon
    • Korean Journal of Microbiology
    • /
    • v.47 no.2
    • /
    • pp.167-169
    • /
    • 2011
  • The Saccharomyces cerevisiae S288c strain does not show haploid and diploid filamentous growth, and biofilm formation, because it has a flo8 nonsense mutation unlike ${\Sigma}1278b$ strain which has a FLO8 gene. During the heat stress experiments to investigate the role of ScKns1, LAMMER kinase in S. cerevisiae, we found that ${\Sigma}1278b$ strain revealed heat sensitivity at $37^{\circ}C$, a mild heat stress in contrast to S288c strain. We also found that the disruption of ScKns1 and the addition of sorbitol suppress heat sensitivity of ${\Sigma}1278b$ strain. These results suggest the possibility that Flo8 and ScKns1 may interact to transducer a signal for regulating heat stress through a novel signaling pathway.

Brown-Sequard Syndrome Produced by Cervical Disc Herniation : Manual and Exercise Therapy after Operation-Case Studies (경추 추간판탈출증에 의한 브라운-시쿼드 증후군 : 수술 후 도수치료와 운동치료 효과-사례연구)

  • Kim, Myung-Joon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.79-85
    • /
    • 2009
  • 목적 : 브라운시쿼드는 대부분 척추손상과 수질외 척추 종양에서 주로 나타난다. 드물게 경추 디스크가 브라운시쿼드의 원인이 된다. 경추디스크에 의한 브라운시쿼드 증세의 수술후 물리치료 및 도수치료 결과를 보고하기 위함이다. 방법 : 50세 남자로써 브라운시쿼드 증세로 진단을 받고 수술후 좌측 팔과 다리에 운동신경에 의한 마비증세가 있었으며(팔>다리), 우측으로 감각과 온도감각이 저하된 경우이다(팔>다리). 측정방법은 통증지수(VAS), 근력(Distal PowerTracII$^{TM}$ test), 지구력(Ergometer) 측정과 심리상태(설문)를 치료전과 후를 비교하였다. 물리치료에서는 기능적 전기자극 치료와 도수치료 및 운동치료 방법을 실시하였다. 도수치료는 통증완화와 근력강화를 위한 MET, MFR, Mobilization 등을 실시하였으며, 운동은 슬링시스템 등을 이용한 운동과 견관절의 불안정을 위해 안정화운동을 실시하였다. 결과 : 이 케이스는 수술후 이상 징후가 척수압박으로 인하여 보다 넓게 통증이 나타났으며, 운동 및 감각신경이 둔해지고 온도에 대한 감각이 반대편 결손으로 나타났으며, 좌측 어깨, 팔 견갑부의 근육 마비와 우측의 감각이 떨어진 현상이 나타났다. 물리치료 후 단기목표와 장기목표에 있어서 통증과 운동 및 감각 기능이 회복되어 각각 팔 통증에서는 VAS 8 ${\rightarrow}$ 1, 상지 하지의 운동기능은 Trace ${\rightarrow}$ Good 로 평가 회복되었으며, 근력측정에서 모두 유의한 차이를 보였다. 모든 치료과정 결과에서 심리적 상태의 설문에서도 높은 점수를 얻어 긍정적 신뢰가 높아 진 것으로 나타났다. 검사결과 다리의 근력이 증가는 걷기 운동 및 에르고메터의 지구력 및 균형이 레벨1의 10분 수행능력이 레벨 20에서 30분 수행능력으로 향상되어 일상적인 활동이 가능해졌다. 결론 : 예상하지 못했던 수술 후유증(side effects)에 대한 치료과정이 환자의 심리에 심각한 부정적인 생각이 신체의 기능과 감정의 손상에 영향을 미치기 때문에 체계적이고 장기적인 치료 과정에서 기능적 향상과 더불어 정신적인 심리의 정서 안정이 매우 필요하다고 사료된다.

  • PDF

$Co_{3}O_{4}$ butane gas sensor operating at low temperature (I) (저온동작용 $Co_{3}O_{4}$ 부탄가스 감지 소자(I))

  • Chung, Jin-Hwan;Choi, Soon-Don
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.6
    • /
    • pp.7-14
    • /
    • 1996
  • In order to develop gas sensor operating at low temperature, thick film $Co_{3}O_{4}$ sensor was fabricated. $Co_{3}O_{4}$ powder was prepared by precipitation from cobalt nitrate solution and the powders containing ethylene glycol as a binder was screen-printed on alumina substrate. Characteristics of sensitivity, response time, and recovery were investigated in terms of binder content and heat treating conditions. The $Co_{3}O_{4}$ sensor contained 15% ethylene glycol and heat-treated at $300^{\circ}C$ for 24hr showed the highest sensitivity at the operating temperature of $250^{\circ}C$. Its sensitivity of 1.1 to 5000ppm butane gas was very high, as compared with $0.8{\sim}0.85$ at the operating temperature of $350{\sim}400^{\circ}C$ for a commercial $SnO_{2}$ gas sensor. It is found that response time was fast, but recovery was poor for the sensor.

  • PDF

Basic Studies on Developing Equipment for Waterless Transportation of Live Fish (활어의 무수 수송 장치 개발을 위한 기초적 연구)

  • CHO Young-Je;KIM Yuck-Yong;LEE Nam-Geoul;CHOI Yeung-Joon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.5
    • /
    • pp.501-508
    • /
    • 1994
  • This study was undertaken to get basic data for the cold-waterless transportation of live fish. The optimal cold temperature of plaice, Paralichthy olivaceus was determined by checking the changes of dissolved oxygen and ammonia in the sea water and the survival times during storage at various temperatures. After determination of optimal temperature for transportation, the changes of serum components and muscle components of live plaice were also carried out during storage at cold($5^{\circ}C$)-waterless conditions and the recovery conditions($10\%$ density at $15^{\circ}C$). At higher storage temperature, decreases in dissolved oxygen and the increases in ammonia in seawater were observed. In addition, the survival time was short at low temperature($0^{\circ}C\;and\;3^{\circ}C$). Almost all of the serum components(hemoglobin, glucose, LDH, GOT and GPT) of live plaice gradually increased during storage in cold-waterless conditions, and then those values decreased to the initial levels after $3{\sim}10hrs$ storage in conditions of recovery. The concentration of ATP in the muscle steadily decreased during storage in cold-waterless conditions. The contents of ADP and IMP seemed to be directly related to the extent of ATP breakdown. ADP and IMP thus showed a gradual increase during storage. The level of lactate in the muscles gradually increased during these storage times, also. On the other hand, the levels of those components in the muscle entirely recovered to their original levels within $3{\sim}6hrs$ storage after they were returned to conditions of recovery. The ratio of ATP to the ATP and its related compounds${ATP/(ATP+ADP+AMP+IMP){\times}100}$ in the muscle showed $45\%$ after 18hrs storage in cold-waterless conditions. Otherwise, ratios returned to their original levels within $3{\sim}6hrs$ of storage in recovery conditions.

  • PDF

Analysis of body surface temperature by Pulsed Magnetic Fields system for evaluation of therapeutic effect of Delayed Onset Muscle Soreness (지연성 근육통증 회복 평가를 위한 경혈 부위에서의 자기장자극에 대한 체열변화 분석)

  • Lee, Na-Ra;Lee, Seung-Wook;Kim, Young-Dae;Kim, Soo-Byeong;Lee, Kyong-Joung;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.3
    • /
    • pp.645-653
    • /
    • 2011
  • The aim of this study was to develop a Pulsed Magnetic Fields(PMFs) system which can produce effects locally and simulate muscular tissues equally. To evaluate the PMFs system we caused DOMS(Delayed Onset Muscle Soreness) to subjects in biceps of the arm. Then, we stimulated acupoint HT2 using PMFs(20 minutes) and TEAS(20 minutes) for 2 days. The other subjects did not stimulate. Then we checked body surface temperature in biceps of the arm. All subjects had an asymmetrical body surface temperature in biceps after exercise(Non-stimulation group=$2.00{\pm}1.16^{\circ}C$, TEAS group=$1.73{\pm}0.52^{\circ}C$, PMFs group=$1.48{\pm}0.51^{\circ}C$). After 1st stimulation all subjects had decreased temperature differences(Non-stimulation group=$1.37{\pm}0.71^{\circ}C$, TEAS group=$1.08{\pm}0.43^{\circ}C$, PMFs group=$1.23{\pm}0.15^{\circ}C$). PMFs group had a symmetry body surface temperature after 24 hours($0.05{\pm}0.06^{\circ}C$) and TEAS group had that after 48 hours($0.1{\pm}0.08^{\circ}C$). Non-stimulation group did not recovery after 48 hours($0.37{\pm}0.06^{\circ}C$). Therefore, PMFs on acupoint had an therapeutic effect in DOMS.

Qualities and Early Growth Responses of Paprika Seedlings Grown in High and Low Temperatures (고온 및 저온에서 육묘된 파프리카 묘의 소질과 정식 후 초기 생육 반응)

  • Cho, Yun-Hee;Kim, Chi-Seon;Kim, Jeong-Man;Ku, Yang Gyu;Kim, Ho Cheol
    • Horticultural Science & Technology
    • /
    • v.34 no.5
    • /
    • pp.719-726
    • /
    • 2016
  • The effect of high and low temperatures on seedling quality while raising of paprika (Capsicum annuum L.) seedlings, and their early development after planting was investigated. The control raising seedling temperature (RST) was $23^{\circ}C$; high temperature, $31^{\circ}C$; and low temperature, $15^{\circ}C$ throughout the raising seedling period. At $15^{\circ}C$ and $30^{\circ}C$, plant height, stem diameter, fresh weight, dry weight, number of leaves, and seedling leaf area were significantly lower than those at $23^{\circ}C$. At 4 weeks after planting, seedling's growth characteristics showed a similar pattern. Compared to $23^{\circ}C$, seedlings raised at $15^{\circ}C$ and $30^{\circ}C$ had an increased dry weight and leaf area per unit time after planting than during the seedling raising period. At 4 weeks after planting, crop growth rate and leaf area index were unaffected by RST, and relative growth rate and net assimilation rate at RSTs of $15^{\circ}C$ and $31^{\circ}C$ were higher than those those at RST of $23^{\circ}C$. At an RST of $15^{\circ}C$, growth speed and net assimilation rates were higher after planting than before planting, according to increased photosynthetic rate. Thus, high and low temperatures during the seedling raising period significantly reduced seedling growth and plant growth after planting. After planting, seedlings raised at $15^{\circ}C$ recovered more quickly than did those raised at $31^{\circ}C$.

Electrical Property Changes of $\textrm{NO}_X$ Sensitive $\textrm{WO}_3$ Thin Films as Applied DC Voltages on 8YSZ Substrate (8YSZ 기판에 증착한 $\textrm{WO}_3$ 박막의 DC 전압에 따른 $\textrm{NO}_X$ 감지특성)

  • 전춘배;박기철
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.8-12
    • /
    • 1999
  • $\textrm{WO}_3$ semiconductive film, which is known to have a sensitivity on $\textrm{NO}_X$ gas was prepared on 8YSZ (8% Yttria stabilized $\textrm{ZrO}_2$) ionic conductor substrate that has oxygen ion pumping effect. Microstructure and electrical properity, especially $\textrm{NO}_X$ sensitivity as a function of DC voltage applied to 8YSZ substrate was examined. When the $\textrm{WO}_3$ film was annealed, it showed amorphous structure, while crystallization was occurred at $600^{\circ}$C revealing orthorhombic phase of $\textrm{WO}_3$. As the annealing temperature increases, (111) and (001) peaks of $\textrm{WO}_3$ film was enhanced. At $400^{\circ}C$ when DC voltage was applied, comparing with no DC bias, more stable and large response characteristics was showed, and the best sensitivity was observed at 2V. Recovery characteristics of NO gas was much better that that of $\textrm{NO}_2$ gas.

  • PDF