Browse > Article
http://dx.doi.org/10.7843/kgs.2019.35.10.5

Analysis on Temperature Change of Ground by Long-term Performance of Energy Pile  

Kim, Beom-Jun (Dept. of Civil Engrg., Gangneung Wonju National Univ.)
Yune, Chan-Young (Dept. of Civil Engrg., Gangneung Wonju National Univ.)
Publication Information
Journal of the Korean Geotechnical Society / v.35, no.10, 2019 , pp. 5-15 More about this Journal
Abstract
In this study, to investigate the effect of long-term performance of energy pile on ground temperature, a numerical analysis was conducted by simulating the ground where an energy pile was installed. In the analysis, a changing distance from the outer perimeter of a heat circulation pipe to the surface of concrete pile for an intermittent operation (8-hour operation, 16-hour stop) was considered. Simulation results showed that long-term heat exchange under the intermittent operation of energy pile reduced a thermal recovery in the ground and increased the ground temperature through the residual thermal energy. In addition, the ground temperature became higher as it got closer to the energy pile and increased as the distance from the outer perimeter of heat circulation pipe to the surface of concrete pile decreased.
Keywords
Energy pile; Long-term performance; Intermittent operation; Operation period; Ground temperature;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Gao, J., Zhang, X., Liu, J., Li, K., and Yang, J. (2008a), "Numerical and Experimental Assessment of Thermal Performance of Vertical Energy Piles", Applied Energy, Vol.85, pp.901-910.   DOI
2 Go, G. H., Yoon, S., Park, D. W., and Lee, S. R. (2013), "Thermal behavior of Energy Pile Consideing Ground Thermal Conductivity and Thermal Interference between Piles", Journal of the Korean Society of Civil Engineers, KSCE, Vol.33, No.6, pp.2381-2391.   DOI
3 Hamada, Y., Saitoh, H., Nakamura, M., Kubota, H., and Ochifuji, K. (2007), "Field Performance of an Energy Pile System for Space Heating", Energy and Building, Vol.39, pp.517-524.   DOI
4 Jeong, S. S., Song, J. Y., Min, H. S., and Lee, S. S. (2010), "Thermal Influential Factors of Energy Pile", Journal of Korean Society of Civil Engineers, KSCE, Vol.30, No.6, pp.231-239.
5 Jeong, S. S., Lim, H. S., Lee, J. K., and Kim, J. H. (2014), "Thermally Induced Mechanical Response of Energy Piles in Axially Loaded Pile Groups", Applied Thermal Engineering, Vol.71, No.1, pp.608-615.   DOI
6 Kim, B. J. and Yune, C. Y. (2016), "Experimental Research on Consolidation bahavior of Soft Ground Using Vertical Drain with Heat Injection", Spring Geotechnical Engineering Conference, Seoul, Korea.
7 Koy, C. and Yune, C. Y. (2017), "Numerical Analysis on Consolidation of Soft Clay by Sand Drain with Heat Injection", Journal of Korean Geotechnical Society, Vol.33, No.11, pp.45-57.   DOI
8 Korea Meteorological Administration (2013, 2014, 2015, 2016, 2017, 2018), Monthly weather report.
9 Li, X., Chen, Y., Chen, Z., and Zhao, J. (2006), "Thermal Performances of Different Types of Underground Heat Exchangers", Energy and Building, Vol.38, pp. 43-547.
10 Lee, D. S., Min, H. S., Lim, H. S., and Jeong, S. S. (2013), "Numerical Analysis of Thermal Effect on Axial Load and Pile Settlements in PHC Energy Piles", Journal of Korean Geotechnical Society, Vol.29, No.5, pp.5-17.   DOI
11 Mimouni, T. and Laloui, L. (2015), "Behaviour of a Group of Energy Piles", Canadian Geotechnical Journal, Vol.52, No.12, pp.1913-1929.   DOI
12 Marto, A., Makhtar, A. M., and Amaludin, A. (2015), "Comparisons on the Response of Shallow Geothermal Energy Pile Embedded in Soft and Firm Soils", Journal Teknologi (Sciences & Engineering), Vol.77, No.11, pp.137-143.
13 Pahud, D. and Hubbuck, M. (2007), "Measured Thermal Performances of the Energy Pile System of the Dock Midfield at Zürich Airport", Proceedings of European Geothermal Congress 2007, Unter-haching, Germany, pp.1-7.
14 Rotta Loria, A. F. and Laloui, L. (2016), "The Interaction Factor Method for Energy Pile Groups", Computers and Geotechnics, Vol.80, pp.121-137.   DOI
15 Saggu, R. and Chakraborty, T. (2016), "Settlement Response of a Geothermal Energy Pile Group in Sand", Geo-Chicago 2016 GSP 270, Chicago.
16 Son, H. S., Jun, K. J., and Yune, C. Y. (2017), "Numerical Analysis of Frost Depth behind the Lining of Road Tunnel in Gangwon Province", Journal of the Korean Geo-Environmental Society, Vol.18, No.3, pp.15-23.   DOI
17 Towhata, I., Kuntiwattanaku, P., Seko, I., and Ohishi, K. (1993), "Volume Change of Clays Induced by Heating as Observed in Consolidation Tests", Japanese Society of Soil Mechanics and Foundation Engineering, Vol.33, No.4, pp.170-183.
18 Wood, C. J., Liu, H., and Riffat, S. B. (2009), "Use of Energy Piles in a Residential Building, and Effects on Ground Temperature and Heat Pump Efficiency", Geotechniques, Vol.59, No.3, pp.287-290.   DOI
19 Bourne-Webb, P. J., Amatya, B., Soga, K., Amis, T., Davidson, C., and Payne, P. (2009), "Energy Pile Test at Lambeth College, London: Geotechnical and Thermodynamic Aspects of Pile Response to Heat Cycles", Geotechniques, Vol.59, No.3, pp.237-248.   DOI