• Title/Summary/Keyword: 온도회복

Search Result 351, Processing Time 0.024 seconds

Effects of Climate and Human Aquatic Activity on Early Life-history Traits in Fish (기후변화와 수상레저활동 인구변화가 어류의 초기생활사에 미치는 영향)

  • Lee, Who-Seung
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.3
    • /
    • pp.395-408
    • /
    • 2013
  • Environmental condition can induce changes in early life-history traits in order to maximise the ecological fitness. Here I investigated how temperature change and variation in human aquatic activity/behaviour affect early life-history consequences in fish using a dynamic-state-dependent model. In this study, I developed a general fish's life-history model including three life-history states depend-ing on foraging activity, such as body mass, mass of reproductive tissue (i.e., gonadal development) and accumulated stress (i.e., cellular or physiological damage). I assumed the level of foraging activity maximises reproductive success-ultimately, fitness. The model predicts that growth rate, development of reproductive tissues and damage accumulation are greater in higher temperature whereas higher human aquatic activity rapidly reduced the growth rate and development of reproductive tissue and increased damage accumulation. While higher foraging activity in higher temperature is less affected by human aquatic activity, the foraging activity in lower temperature rapidly declined with human aquatic activity. Moreover, lower survival rate in higher temperature or human aquatic activity was independent on mortality rate due to human aquatic activity or mortality rate when foraging activity, respectively. However, the survival rate in lower temperature or human aquatic activity was dependent on these mortality rates. My findings suggest that including of early life-history traits in relation to climate-change and human aquatic activity on the analysis may improve conservation plan and health assessment in aquatic ecosystem.

A Study on the Characteristics of Silica Fine Glass Particles prepared by Flame Hydrolysis Deposition Process (FHD법으로 형성된 실리카 유리미립자의 특성에 관한 연구)

  • Choe, Jun-Gi;Jeong, Myeong-Yeong;Choe, Tae-Gu
    • Korean Journal of Materials Research
    • /
    • v.7 no.10
    • /
    • pp.845-850
    • /
    • 1997
  • 수직형 FHD증착법을 사용하여 SiO$_{2}$, SiO$_{2}$-P$_{2}$O$_{5}$, SiO$_{2}$P$_{2}$O$_{5}$-B$_{2}$O$_{3}$-GeO$_{2}$계 실리카 유리미립자를 형성하였으며, SEM, ICP-AES, XRD, TGA-DSC을 사용하여 그 특성을 분석하였다. XRD측정을 통해, 미립자 형성시 사용된 화염온도(130$0^{\circ}C$-150$0^{\circ}C$)와 기판온도(-20$0^{\circ}C$)가 SiO$_{2}$-P$_{2}$O$_{5}$계 미립자를 비정질상태로 형성하였으며, SiO$_{2}$P$_{2}$O$_{5}$-B$_{2}$O$_{3}$와 SiO$_{2}$P$_{2}$O$_{5}$-B$_{2}$O$_{3}$-GeO$_{2}$계 미립자에서는 B$_{2}$O$_{3}$, BPO$_{4}$, GeO$_{2}$의 결정성피크들을 관찰하였다. TGA-DSC 열분석을 통해, SiO$_{2}$와 SiO$_{2}$-P$_{2}$O$_{5}$는 온도변화에 따른 질량변화가 없었으며, SiO$_{2}$P$_{2}$O$_{5}$-B$_{2}$O$_{3}$-GeO$_{2}$계의 경우 질량감소를 동반한 유리전이에 따른 분자이완현상 및 결정화나 회복반응을 나타내고 있다. 질량감소는 미립자가 결정상태일때 가속되는 경향을 나타냈으며, DSC열분석을 통해 SiO$_{2}$, SiO$_{2}$-P$_{2}$O$_{5}$, SiO$_{2}$P$_{2}$O$_{5}$-B$_{2}$O$_{3}$-GeO$_{2}$계 유리미립자들의 고밀화가 시작되는 온도를 각각 1224$^{\circ}C$, 1151$^{\circ}C$, 953$^{\circ}C$, 113$0^{\circ}C$에서 관찰하였다.

  • PDF

Implementation of Digital Desoldering System for Removing Lead-free Solder (무연 솔더 제거를 위한 디지털 디솔더링 시스템 구현)

  • Oh, Kab-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.322-328
    • /
    • 2012
  • This paper deals with a digital Desoldering system for removing lead-free solder. We proposed a Desoldering system that is to cope with the changed work environment of the solder materials changing from lead solder to lead-free solder, we can be quickly stable to the set temperature, and continuous operation is possible. Proposed system consists of a Desoldering station and a Desoldering gun. For the PID temperature control, we designed the 8bit MCU peripheral circuit. We had a few experiments to confirm the performance of the proposed system, and compared with the specification of same kind of imports. As a result, proposed system than the imported products showed good performance as follows: the time to reach operating temperature is 11 seconds faster, ripple temperature variation is $1.5^{\circ}C$ lower, temperature recovery rate is about $0.14^{\circ}C$/sec faster.

Studies on Thermal Oxidation of Soybean Oil : Changes in Some Rheological Properties of a Soybean Oil during Thermal Oxidation (가열산화중의 콩기름의 유동학적 연구)

  • Shin, Ae-Ja;Kim, Dong-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.141-145
    • /
    • 1985
  • In the present study, an attempt was made to investigate the characteristics of rheological properties of a themally oxidized soybean oil. Various flow curves of the oxidized oils were obtained using a broad range of shear rate (452-904 rpm). The flow curves showed the characteristics of thixotropic flow, and as temperature decreased (range : 13-$37^{\circ}C$) they demonstrated increasingly stronger thixotropic properties. A thixotropic slope similar to the coefficient of thixotropy as applied to the rheological characteristics of the thermally oxidized soybean oil to predict its rheological properties quantitatively at an equilibrium state. The empirical formula with the thixotropic slope was found satisfactory in predicting the Non-Newtonian behavior of the thermally oxidized soybean oil.

  • PDF

The Effect of pH and Temperature on Lysozyme Separation in Ion-exchange Chromatography (이온교환크로마토그래피에서 라이소자임 분리에 미치는 pH와 온도 영향)

  • Ko, Kwan-Young;Kim, In-Ho
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.98-105
    • /
    • 2014
  • Lysozyme amounts to 0.3% in egg white and functions as an agent of cell lysis and activator of tissue reconstruction. Ion exchange chromatography is the most useful method of separation among affinity chromatography, ion exchange chromatography, and ultra-filtration. The aim of present study is to find the optimum pH and temperature for the separation of lysozyme in egg white within cation exchange gel filled glass column. And we compared results of experiments with those of simulations. Phosphate buffer was used, and pH and temperature were varied as 5~7 and $25{\sim}40^{\circ}C$ respectively. RP-HPLC was the tool for the retention time identification and quantitative analysis of lysozyme. OriginPro 8 measured the peak area of lysozyme chromatogram and quantified the eluted lysozyme. Largest amount of lysozyme was separated under the conditions of pH 5 and T $25^{\circ}C$.

Effect of Preservation Period, Light, Temperature, and Priming on the Seed Germination of Lysimachia mauritiana (자생 갯까치 수영(Lysimachia mauritiana)의 종자발아에 미치는 저장기간, 광, 온도 및 Priming 처리의 영향)

  • 안영희;설종호;조근호
    • Korean Journal of Environment and Ecology
    • /
    • v.12 no.1
    • /
    • pp.9-13
    • /
    • 1998
  • Because Lysimachia mauritiana is not able to maintain the seed viablity for a long time, it has difficulties in using for the ornamental plants or landscape gardening. This study was conducted to elucidate the optimal germination conditions of Lysimachia mauritiana seeds. The germination rate of the seeds was higer in light condition than in dark one. In experment determining the proper germination temperature, the germination rates were 2.2%, 96.9% and 91.2% under 35$\circ $C, 25$\circ $C, and 20$\circ $C, respectively in light condition. The approprate temperature for the germination was 25$\circ $C in light. The decreases of germination rate with the increase of the preservation periods was able to recover by priming pretreated with NaCl solution and KNO$_{3}$ + K$_{3}$H$_{2}$PO mixed solutions. When the storage period was 300 days, the germination rate was 75% without priming treatments. But the seeds primed with NaCl 0.1M and KNO$_{3}$ + K$_{3}$H$_{2}$PO mixed solutions 0.1M, showed germination rate above 90%. T$_{50}$ also was shorten from 5.25 without priming to 3.78 with NaCl 0.1M. Seed priming may induce earlier sprouts and increase germination rate of long-preserved seeds of native wild plants.

  • PDF

Study on Exfoliation and Recovery of Anesthetized Yound Abalones, Haliotis discus hannai Treated with Ethy-p-aminobenzoate and Freshwater in Different Temperatures of Sea water (온도구간별 파라아미노안식향산에틸과 담수에 의한 양식산 참전복 (Haliotis discus hannai) 치패의 박리 및 마취회복에 관한 연구)

  • 최상덕;정성채;김호진;공용근;백재민;최규정
    • Journal of Aquaculture
    • /
    • v.10 no.3
    • /
    • pp.281-288
    • /
    • 1997
  • We investigated the optimal concentratin of ethyl-p-aminobenzoate for the exfoliation and recovery of young abalone, Haliotis discus hannai in according to different water temperatures, for the purpose of preventing the damage of shell and muscle to ecfoliated from shelter. In the 14$^{\circ}C$ water temperature, young abalones were exfoliated after 16, 35, 35 and 35 minutes in 150, 100, 75 and 50ppm concentration of ethyl-p-aminobenzoate, and were recovered after 100, 60, 30 and 30 minutes, respectively. Exfoliation rate of abalone were 100% except for 50 ppm (80%) and recovery rate were 100% of all concentration. In the $18^{\circ}C$ water temperature, young abalones were exfoliated after 4, 4, 6, 8, 8 and 12 munutes in 300, 200, 150, 100, 75 and 50ppm concentration of ethyl-p-aminobenzoate, and were recovered after 210, 180, 90, 60, 30, 20 and 20 minutes, respectively. Exfoliation rate of abalone were 100%, and recovery rate were 100% except for 200 and 300ppm (90%). In the $24^{\circ}C$ water temperature, young abalones were exfoliated after 8, 10, 10 and 12 minutes in 150, 100, 75 and 50ppm concentration of ethyl-p-aminobenzoate, and were recovered after 70, 50, 30 and 20 minutes, respectively. Exfoliation and recovery rate of abalone were 100%. In the 18$^{\circ}C$water temperature, exfoliation rate that treated with freshwater during 20 minute were 80, 50, 30 and 5% in 100, 75, 50 and 25% of fresh water, and recovery after 60, 15, 10 and 2 minutes, respectively and recovery arate were 100% except of r 100% freshwater. In this study, we suggest the reslults that the exfoliation and recovery by ethly-p-aminobenzoate were more effected in $18^{\circ}C\;and\;24^{\circ}C$ of sea water temperature than those of $14^{\circ}C$. The optimal concentration of ethyl-p-aminobenzoate was 50ppm at those water temperature. We raised 20 individual of young abalones at water temperature of $16^{\circ}C$ in the 1$\ell$ o ftnk and checked the variatin of dissolved oxygen (DO) by respiration of abalones that treated with 75ppm of ethyl-p-aminobenzoate. Before anesthetizion, DO were 6.17~6.20mg/$\ell$ and slowly decreased. But after 60 minutes, DO decreasing were stopped in 5.42~5.46mg/$\ell$. On the other hand, the control was continuously decreased and 5.27mg/$\ell$ after 60 minutes. The heartbeats of abalones were 33~45/minute in the water temperature of $18^{\circ}C$, but that treated with 100 ppm concentration of ethyl-p-aminobenzoate during 60 minutes, was 0/minute. And heartbeats of recovered abalones from anesthetizion were 29~43/minute.

  • PDF

A Feasibility Study on Sewage Discharge Water Treatment for Water Reuse by Direct Contact Membrane Distillation (하수처리수 재이용을 위한 직접접촉식 막증발법 적용 가능성 연구)

  • Choi, Yongjun;Choi, Jihyuck;Shin, Yonghyun;Cho, Hyeongrak;Sohn, Jinsik;Lee, Sangho
    • Membrane Journal
    • /
    • v.26 no.1
    • /
    • pp.70-75
    • /
    • 2016
  • The reuse of wastewater is being diffused to manage and develop the water resources. Generally, the treated wastewater is discharged to the river after being treated to meet the effluent quality standard or reused for diverse uses through the reprocessing. And recently, as the reuse of the treated wastewater is activated, the technologies to utilize for the high quality water resources such as industrial water by reusing the wastewater with Membrane Distillation (MD) are under development. In this study, the direct contact membrane distillation (DCMD) process has been applied to treat sewage discharge water for water reuse. The laboratory scale experiment was performed by using a hydrophobic PVDF membrane with the pore size of $0.22{\mu}m$. The influence of operating parameters, such as feed temperature, feed flow rate, feed concentration, on the permeate flux and rejection has been investigated. All filtration tests were conducted till the feed volume reached a concentration factor of 3.0. Thus, the operating period ranged between 19 hr and 49 hr depending on filtration performance. The results showed that above 92% of TN, TP, COD and TOC in the feed could be rejected regardless of an operating condition. The water flux was ranged from 13.8 to 20.3 LMH. The lowest flux was obtained at the operating condition with the feed temperature of $50^{\circ}C$ and feed flow velocity of 500 mL/min while the highest one was measured with $60^{\circ}C$ and 900 mL/min. When the concentration factor reached 3.0, water flux declined by approximately ranged from 14.5% to 33.3%. But the fouling in MD is almost fully reversible, with more than 90% recovery of permeate water flux following a DI water rinse without the addition of chemical cleaning reagents.

A Study on Microstructure and Mechanical Properties of Modified 9Cr-1Mo and 9Cr-0.5Mo-2W Steels for nuclear Power Plant (원자력용 개량 9Cr-1Mo 및 9Cr-0.5Mo-2W 강의 미세조직과 기계적 특성 연구)

  • Kim, Seong-Ho;Song, Byeong-Jun;Han, Chang-Seok;Guk, Il-Hyeon;Ryu, U-Seok
    • Korean Journal of Materials Research
    • /
    • v.9 no.11
    • /
    • pp.1137-1143
    • /
    • 1999
  • Microstructure and mechanical properties of Mod.9Cr-1Mo and W added 9Cr-0.5Mo2W steels were investigated for liquid metal reactor (LMR) heat exchange tube. The tempering temperatures at which cell structure was formed were $700^{\circ}C$ for Mod.9Cr-1Mo steel and $750^{\circ}C$ for W added 9Cr0.5Mo-2W steel. indicating the recovery of dislocation was delayed by the addition of W. 9Cr-0.5Mo-2W steel had the same kinds of precipitates with Mod.9Cr-1Mo steel, but the W was included in the precipitates in 9Cr-0.5Mo-2W steel. Micro-hardness and ultimate tensile strength of 9Cr-0.5Mo-2W steel were higher than those of Mod.9Cr-1Mo steel. The impact property of Mod.9Cr-1Mo steel was superior to that of 9Cr-0.5Mo-2W steel.

  • PDF

Behavior of secondary defects by high energy Implantation along Thermal Process (열처리에 따른 이온 주입시 발생하는 2차결함의 거동)

  • Kim, Suk-Goo;Kwack, Kae-Dal;Yoon, Sahng-Hyun;Park, Chul-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1827-1829
    • /
    • 1999
  • 반도체 소자가 고집적화 되고 미세화 될수록 좁은 면적에 여러 기능을 가진 우물을 형성시켜야하나 기존의 우물로는 고온 장시간 열처리로 인하여 측면 확산이 깊게 되고, 불순물 농도 분포는 표면으로부터 농도가 점차 낮아진다. 따라서 기존 우물의 불순물 분포로는 기생 트랜지스터에 의한 렛치-엎과 알파 입자에 의한 SER의 감소를 위하여 필요한 벌크에서의 고농도 분포를 유지하기가 곤란하다. 이러한 문제는 차세대 반도체 개발을 위해서는 반드시 해결해야 할 것이며 이것을 해결할 수 있는 공정으로는 고 에너지 이온 주입과 저온, 단시간 열처리이다. 고 에너지 이온 주입 시의 불순물 분포를 어떻게 제어할 것인가에 대한 것과 여기서 부수적으로 나타나는 격자 손상과 그 회복 및 잔류결함의 성질을 어떻게 알고 이를 게터링 등에 이용할 것이냐에 대한 것이다. 실리콘 기판 내로 가속된 이온은 실리콘 격자와 충돌하면서 많은 1차 결함이 생기고. 이들은 후속 열처리 과정에서 활성화되면서 대부분은 실리콘 격자의 위치에 들어가 활성화되고. 그 나머지는 실리콘내의 격자간 산소, 격자간 실리콘. 격자 빈자리와 상호 작용을 하여 2차 결함을 형성한다. 에피택셜 웨이퍼와 p-type웨이퍼에 비소 이온을 고에너지로 주입후 2단계 열처리에 의한 농도분포변화와 핵생성과 결함성장에 관해 실험하였고, 핵생성온도는 $600^{\circ}C$이하이고, 성장에 필요한 온도는 $700^{\circ}C$이상이다.

  • PDF