• 제목/요약/키워드: 옥외

Search Result 723, Processing Time 0.024 seconds

Research on the Impact of interactive Digital Signage Advertising on Consumption Tendency (Interactive Digital Signage에 광고의 마케팅이 소비 경향에 대한 연구)

  • Yang, Bo
    • Journal of Digital Convergence
    • /
    • v.18 no.4
    • /
    • pp.411-417
    • /
    • 2020
  • In this study, the Interactive advertising in the Outdoor Interactive Digital Signage is taken as the research object, and the effect of the advertising in the Outdoor Interactive Digital Signage compared to the traditional advertising on consumer propensity is studied. Based on the research methods of literature data and case analysis, we first researched and analyzed the impact of the development of the Internet and artificial intelligence on Interactive Digital Signage advertising, combined with consumer trends and habits, according to the characteristics of Interactive Digital Signage advertising, and '199IT-Internet data Based on the data in the Resource Library, and using an example analysis method, three reasons for the impact of Interactive digital signage advertisements on consumer spending tendencies are proposed. The purpose is to provide reference for future companies to use Interactive digital signage for ad placement and help companies. Increase product sales to increase product value and customer trust in the brand.

Effect of Vehicle Resin on Coating Performance of Dan-Chung (교착제 종류에 따른 단청의 도막 성능)

  • Han, Gyu-Seong;Shin, Soo-Jeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.44-50
    • /
    • 2007
  • The objective of this study was to investigate the influence of the vehicle resin on the coating performance of Dan-Chung. The starch glue (F), fish glue (G), and aqueous acrylic resin emulsion (E) were used as vehicle resins. Panels coated with Dan-Chung were tested at accelerated weathering and outdoor conditions. Aqueous acrylic resin was proved as an excellent vehicle resin for Dan-Chung, because there was no flaking in Dan-Chung film after accelerated weathering and outdoor exposure. Discoloration of Dan-Chung using E was the smallest among the acceleratedly weathered panels. Adhesive property of Dan-Chung film using G was. remarkably improved by G-undercoating. On the contrary, G-undercoating lowered adhesive property of Dan-Chung film using E.

The Evaluation of the Preservative Treated Plywood Produced by Factory Processing (야외사용을 목적으로 공장라인에서 생산한 방부합판의 성능평가)

  • Son, Dong Won;Lee, Sang-Min;Lee, Dong-heub;Kang, Eun-Chang;Park, Byung Su
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.47-54
    • /
    • 2008
  • To make up original defects of the wooden materials for decks, and to supply the wooden material for outdoor, we fabricated preservative treated plywood(PTP). Copper azole (CUAZ-1) preservative was treated with a normal full-cell process. Bond Strength of PTP was not affected after the preservative treatment. The anti-fungal efficiency and dimensional stability were obtained from PTP. A little discoloration of the surface was detected, but the dimensional change or peel bonded area off were not observed after accelerated weathering test. Although some strength of PTP was reduced after 17 months of field exposure, the PTP should be applicable for outdoor applications.

A Study on the Performance Improvement Plan of Inflowing Air Emission (유입 공기의 배출 성능 개선방안에 관한 연구)

  • Lee, Hye-Young
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.241-251
    • /
    • 2022
  • Purpose: In the event of a fire in a high-rise building, if the smoke control area is not effectively protected, smoke or flames enter the stairwell, making it difficult to evacuate. When inflowing air is discharged from a closed corridor, a negative pressure is formed in the corridor, the pressure in the smoke control area becomes excessively high, and the force required to open the door during evacuation is exceeded. Also, if the air introduced into the hallway is not exhausted, the smoke may flow back into the smoke control area. This paper tried to identify the problems caused by the inflowing air and to find out how to improve the performance. Method: Using the CONTAM program, simulations were performed with the basic conditions and the modified conditions. Result: If the inflowing air was discharged from the sealed corridor, overpressure occurred in the Smoke Control Area and exceeded the opening force, and the prevent smoke backflow was insufficient in the layer where the inflowing air was not discharged. Conclusion: "Differential pressure exhaust damper" application, simultaneous opening of two exhaust dampers, and automatic window installation between corridors and outdoors improved the exhaust performance of inflowing air.

Carbonation Properties of Ordinary Concrete Exposed for 15 Years (15년간 노출 시험한 일반 콘크리트의 탄산화 특성 검토)

  • Lee, Binna;Lee, Jong-Suk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.261-268
    • /
    • 2022
  • In this study, Long-term test specimens were tested in the outdoor exposure environment and the carbonation properies of concrete were analyzed. The test specimens were manufactured in 40 %, 50 % and 60 % according to the w/c ratio. Carbonation was measured at 3 years and 15 years of age. Based on the results, long-term carbonation prediction models(KICT model) were derived. As a result, carbonation increased according to the w/c. Based on the w/c 40 %, w/c 50 % increased about 1.8 times and w/c 60 % increased about 3.7 times. Comparison of carbonation according to age was that the carbonation at 15th year was about 3 times higher that of 3rd year. As results of comparing the KICT models and other carbonation prediction models, the carbonation prediction showed different values.

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.

Study on the Current Status Analysis of Urban Green Spaces in Seoul Focusing on Elementary School Surroundings - Remote Sensing Based Vegetation Classification - (초등학교 주변을 중심으로 본 서울시 도시녹지 현황 분석 및 고찰 - 원격탐사 방법을 이용한 식생분류 -)

  • Kim, Hyun-Ok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.8-18
    • /
    • 2012
  • Urban nature plays an important role not only in the improvement of the physical environment but also from the perspective of psychological and social function. In particular, schoolyards as well as the green spaces near school surroundings function as a primary space for urban children to experience nature in Korea, as they spend most of their time at school. In this study, the status of urban green spaces near school surroundings was examined. For the analysis, 185 elementary schools in Seoul were selected and the green spaces within a radius of 300m(defined as 'school zone' in this study) were analyzed using the Rapid Eye multispectral satellite image data. The mean green space ratio of school zone accounts to about 21% with a high variation from 74% to 0.7% and more than half of the school zone have a green space ratio of less than 20%. Schools with a high green space ratio in their school zone are mostly located near urban forests, so forest areas particularly contribute to increase the green space ratio. Furthermore, forest vegetation shows relatively higher vitality than other green spaces located in urbanized areas. In contrast, schools with a low green space ratio in their school zone are mostly situated in high-density residential areas and the green spaces show relatively low vegetation vitality. Except for the urban forest, the majority of urban green spaces in urbanized areas are landscape green facilities in apartment districts. The other types of urban open spaces such as environmentally shaped schoolyards or street parks account only for a very small proportion of school surroundings. Therefore, it is needed to establish countermeasures in the context of urban planning; e.g. to promote the school forest projects preferentially by selecting schools with a extremely low green space ratio in their school zone, to foster roof greening in near surroundings, and to connect schoolyards organically with nearby apartment landscape green facilities as an easily accessible urban open space.

Simultaneous Treatment of Carbon Dioxide and Ammonia by Microalgal Culture (조류배양을 통한 이산화탄소 및 암모니아의 동시처리)

  • ;;Bohumil Volesky
    • KSBB Journal
    • /
    • v.14 no.3
    • /
    • pp.328-336
    • /
    • 1999
  • A green microalga, Chlorella vulgaris UTX 259, was cultivated in a bench-scale raceway pond. During the culture, 15%(v/v) $CO_2$ was supplied and industrial wastewater discharged from a steel-making plant was used as a culture medium. In a small scale culture bottle, the microalga grew up to 1.8 g $dm^{-3}$ of cell concentration and ammonia was completely removed from the wastewater with an yield coefficient of 25.7 g dry cell weight $g^{-1}\;NH_3-N$. During the bottle-culture, microalga was dominant over heterotrophic microorganisms in the culture medium. Therefore, the amount of carbon dioxide fixation could be estimated from the change of dry cell weight. In a semi-continuous operation of raceway pond with intermittent lighting (12 h light and 12 h dark), increase of dilution rate resulted in increase of the ammonia removal rate as well as the $CO_2$ fixation rate but the ammonia removal efficiency decreased. Ammonia was not completely removed from the medium (wastewater) of raceway pond which was operated in a batch mode under a light intensity up to 20 klux. The incomplete removal of ammonia was believed due to insufficient light supply. A mathematical model, capable of predicting experimental data, was developed in order to simulate the performance of the raceway pond under the light intensity of sun during a bright daytime. Simulation results showed that the rates of $CO_2$ fixation and ammonia removal could be enhanced by increasing light intensity. According to the simulation, 80 mg $dm^{-3}$ of ammonia in the medium could be completely removed if the light intensity was over 60 klux with a continuous lighting. Under the optimal operating condition determined by the simulation, the rates of carbon dioxide fixation and ammonia removal in the outdoor operation of raceway pond were estimated as high as $24.7 g m^{-2} day^{-1}$ and $0.52 g NH_3-N m^{-2} day^{-1}$, respectively.

  • PDF

The Comparison of the Solar Radiation and the Mean Radiant Temperature (MRT) under the Shade of Landscaping Trees in Summertime (하절기 조경용 녹음수 수관 하부의 일사와 평균복사온도 비교)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.5
    • /
    • pp.22-30
    • /
    • 2014
  • The purpose of this study was to compare the Solar Radiation(SR) and the Mean Radiant Temperature(MRT) under the shades of the three landscaping trees in clear summer daytimes. The trees were Lagerstroemia indica, Quercus palustris and Ulmus parvifolia. The solar radiation, the globe temperature and the air temperature were recorded every minute from the $1^{st}$ of April to the $30^{th}$ of September 2013 at a height of 1.1m above on the four monitoring stations, with four same measuring system consisting of a solar radiation sensor, two resistance temperature detectors(Pt-100), a black brass globe (${\phi}50mm$) and data acquisition systems. At the same time, the sky view photos were taken automatically hourly by three scouting cameras(lens angle: $60^{\circ}$) fixed at each monitoring station. Based on the 258 daily sky view photos and 6,640 records of middays(10 A.M.~2 P.M.) from the $1^{st}$ of June to the $30^{th}$ of August, the time serial differences of SR and MRT under the trees were analysed and compared with those of open sky, The major findings were as follows; 1. The average ratio of sky views screened by the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were 99%, 98% and 97%, and the SR were $106W/m^2$, $163W/m^2$ and $202W/m^2$ respectively, while the SR of open sky was $823W/m^2$. Which shows the canopies blocked at least 70% of natural SR. 2. The average MRT under the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were $30.34^{\circ}C$, $33.34^{\circ}C$ and $34.77^{\circ}C$ respectively, while that of open sky was $46.0^{\circ}C$. Therefore, it can be said that the tree canopies can reduce the MRT around $10{\sim}16^{\circ}C$. 3. The regression test showed significant linear relationship between the SR and MRT. In summary, the performances of the landscaping shade trees were very good at screening the SR and reducing the MRT at the outdoor of summer middays. Therefore, it can be apparently said that the more shade trees or forest at the outdoor, the more effective in conditioning the outdoor space reducing the MRT and the useless SR for human activities in summertime.

A Study on Greenspace Planning Strategies for Thermal Comfort and Energy Savings (열쾌적성과 에너지절약을 위한 녹지계획 전략 연구)

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.3
    • /
    • pp.23-32
    • /
    • 2010
  • The purpose of this study is to quantify human energy budgets for different structures of outdoor spatial surfaces affecting thermal comfort, to analyze the impacts of tree shading on building energy savings, and to suggest desirable strategies of urban greenspace planning concerned. Concrete paving and grass spaces without tree shading and compacted-sand spaces with tree shading were selected to reflect archetypal compositional types for outdoor spatial materials. The study then estimated human energy budgets in static activity for the 3 space types. Major determinants of energy budgets were the presence of shading and also the albedo and temperature of base surfaces. The energy budgets for concrete paving and grass spaces without tree shading were $284\;W/m^2$ and $226\;W/m^2$, respectively, and these space types were considerably poor in thermal comfort. Therefore, it is desirable to construct outdoor resting spaces with evapotranspirational shade trees and natural materials for the base plane. Building energy savings from tree shading for the case of Daegu in the southern region were quantified using computer modeling programs and compared with a previous study for Chuncheon in the middle region. Shade trees planted to the west of a building were most effective for annual savings of heating and cooling energy. Plantings of shade trees in the south should be avoided, because they increased heating energy use with cooling energy savings low in both climate regions. A large shade tree in the west and east saved cooling energy by 1~2% across building types and regions. Based on previous studies and these results, some strategies including indicators for urban greenspace planning were suggested to improve thermal comfort of outdoor spaces and to save energy use in indoor spaces. These included thermal comfort in construction materials for outdoor spaces, building energy savings through shading, evapotranspiration and windspeed mitigation by greenspaces, and greenspace areas and volume for air-temperature reductions. In addition, this study explored the application of the strategies to greenspace-related regulations to ensure their effectiveness.