• Title/Summary/Keyword: 옥외시설

Search Result 93, Processing Time 0.033 seconds

Constructing Landscape as an Operational Multi-Environmental Control Utility and Green Infrastructure - Landscape Design for National Marine Biology Resource Institute - (작동하는 복합환경조절장치 및 녹색기반시설로서 조경 - 국립해양생물자원관 옥외공간 설계 -)

  • Sung, Jongsang
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.2
    • /
    • pp.41-56
    • /
    • 2012
  • Landscape space can and should play as a multi-functional agent : healing contaminated soil, reducing natural hazards, supporting living things, making comfortable environment for human, and appealing to human aesthetics, etc. This article aims to show the possibility and role of landscape space as such agent. In landscape design for National Marine Biology Resource Institute, distributed rain water treatment system and rain gardens are introduced to replace a mono-functioning large detention pond which was suggested by disaster impact assesment. Phytoremediation and vegetation filtering system with muti-cell wetlands are also adapted to heal the contaminated soil. This kind of landscape as a 'living machine' which can play as an operational control utility of multi-environment and thus can be combined effectively into green infrastructure is important for post-industrial city, especially in an era of climate change.

A Study on the Problems and Improvement of the Interface of Indoor Alarm Broadcasting System (옥내경보방송시스템 연계의 문제점 및 개선방안 연구)

  • Lee, Seung-Hyung;Ahn, Byung-Dug;Lee, Won-Seok;Min, Se-Hong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2018.06a
    • /
    • pp.285-287
    • /
    • 2018
  • 최근 우리나라에서도 지진이 발생하는 등 각종 재난의 발생 빈도가 증가하고 있어 이에 대비하는 사회적 필요성이 대두되고 있다. 특히, 재난발생 시 일반 대중들에 전달되는 경보와 방송에 대한 관심이 높아지고 있다. 국내 재난경보방송시스템은 오랜 역사를 거쳐 정부와 지자체가 관심을 가지고 구축해 왔으며, 인구가 밀집되어 있는 장소나 여름철 집중호우가 예상되는 유원지 등에 집중적으로 설치되어 있다. 옥외를 중심으로 경보방송을 서비스하고 있었으나 건물 내부에는 경보나 방송이 전달되지 못하여 재난발생 시 대규모 피해가 예측되므로 옥내경보방송 서비스의 필요성이 중요하게 인식되었고 최근에는 지자체 별로 활발하게 시스템 설치가 진행되고 있다. 옥내경보방송은 구내방송시설인 전관방송시스템과 연계되어 서비스하는 방향으로 진행되고 있으며 본 저자도 이에 동의하는 바이다. 그러나 전관방송시스템은 오랜 동안 이와 같은 필요성이 없는 상태에서 구축되어 왔고 제조사 별로 외부장비의 연계 방식에 대하나 규격이 다르게 발전해 왔다. 따라서 옥내경보방송장치와 전관방송시스템을 연계하기 위해서는 장비의 제어와, 오디오 인터페이스(interface)가 필수적 요소이므로 이를 반드시 연계하여야 한다. 본 논문에서는 옥내경보방송장치와 전관방송시스템들의 인터페이스를 위해 문제점들을 분석하고 이들의 개선방안에 대해 연구한다. 또한 연계 규격의 표준화에 대한 필요성을 강조하여 각 제조사들이 연계 규격을 준수하고 보다 많은 국민들이 재난경보방송 서비스를 누릴 수 있도록 제언한다.

  • PDF

Study on the Current Status Analysis of Urban Green Spaces in Seoul Focusing on Elementary School Surroundings - Remote Sensing Based Vegetation Classification - (초등학교 주변을 중심으로 본 서울시 도시녹지 현황 분석 및 고찰 - 원격탐사 방법을 이용한 식생분류 -)

  • Kim, Hyun-Ok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.8-18
    • /
    • 2012
  • Urban nature plays an important role not only in the improvement of the physical environment but also from the perspective of psychological and social function. In particular, schoolyards as well as the green spaces near school surroundings function as a primary space for urban children to experience nature in Korea, as they spend most of their time at school. In this study, the status of urban green spaces near school surroundings was examined. For the analysis, 185 elementary schools in Seoul were selected and the green spaces within a radius of 300m(defined as 'school zone' in this study) were analyzed using the Rapid Eye multispectral satellite image data. The mean green space ratio of school zone accounts to about 21% with a high variation from 74% to 0.7% and more than half of the school zone have a green space ratio of less than 20%. Schools with a high green space ratio in their school zone are mostly located near urban forests, so forest areas particularly contribute to increase the green space ratio. Furthermore, forest vegetation shows relatively higher vitality than other green spaces located in urbanized areas. In contrast, schools with a low green space ratio in their school zone are mostly situated in high-density residential areas and the green spaces show relatively low vegetation vitality. Except for the urban forest, the majority of urban green spaces in urbanized areas are landscape green facilities in apartment districts. The other types of urban open spaces such as environmentally shaped schoolyards or street parks account only for a very small proportion of school surroundings. Therefore, it is needed to establish countermeasures in the context of urban planning; e.g. to promote the school forest projects preferentially by selecting schools with a extremely low green space ratio in their school zone, to foster roof greening in near surroundings, and to connect schoolyards organically with nearby apartment landscape green facilities as an easily accessible urban open space.

Introduction of the Best Practices in the Pakistan Gulpur HEPP (파키스탄 Gulpur 수력발전 현장의 Best Practices 소개)

  • JANG, Ock Jae;HONG, Won Pyo;CHAE, Hee Moon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.216-217
    • /
    • 2022
  • Gulpur 수력발전 프로젝트는 전력난을 겪고 있는 파키스탄에 102 MW 규모의 수력발전소를 건설하여 30년 동안 운영 관리한 후 파키스탄 정부로 양도하는 IPP(Independent Power Producing) 형식의 투자사업이다. 남동발전과 DL E&C, 롯데건설이 Sponsor로서 출자한 자본금과, ADB, IFC, K-EXIM 등의 대주단로부터의 차입금을 재원으로 하여 소요 사업비를 조달하고 사업을 개발하였다. DL E&C와 롯데건설이 EPC(Engineering, Procurement, Construction)를 수행하였고, 이산이 Design consultant의 역할을 수행하였다. Gulpur 수력발전 프로젝트의 발전형식은 수로식(run-of-river)으로 201 m3/s의 발전유량과 102 MW의 발전 시설용량을 이용하여 연평균예상발전량은 398 GWh이다. 주요 구조물로는 설계 재현빈도 1년의 유수전환시설(가물막이댐 & 가배수터널)과 콘크리트 중력식댐(H 67 m, L 205 m), 도수터널(D 6.7 m, L 215 m, 2기), 옥외형 발전소 (H 51 m, W 60 m, L 38 m, Kaplan 2기)가 있으며, 2015년 10월 착공하여 2020년 3월 상업발전을 시작하였다. 본 프로젝트는 DL E&C의 첫 번째 EPC 해외수력발전 프로젝트이다. 따라서 프로젝트의 성공적 수행을 위한 경제적 설계, 시공의 효율성 및 안정성 확보 등을 위하여 많은 연구를 수행하는 과정에서 다양한 기술 개선을 이룰 수 있었다. 본고에서는 Gulpur 프로젝트를 통하여 도출된 성공 사례들을 소개 및 공유하고자 한다. 첫 번째로 콘크리트 중력식댐 시공을 위한 유수전환시설의 최적 설계빈도를 산정하였다. 일반적으로 유수전환시설의 규모는 설계기준에 제시된 설계 재현빈도를 이용하는데, 해외 설계기준에서는 10년, 국내 설계기준에서는 1~2년으로 다르게 제시되어 있는 문제점이 있다. 유수전환시설의 규모는 프로젝트의 경제성에 큰 영향을 미치기 때문에 최적 설계빈도의 결정이 필요하며, 위험도분석기법(Risk Analysis)과 기대화폐가치법(Expected Monetary Value)을 이용하여 유수전환시설의 최적 설계 재현빈도와 이에 영향을 미치는 인자를 분석하였다. 위험도는 몬테카를로 시뮬레이션으로 산정된 가물막이댐 파괴확률과 재현빈도를 이용하여 산정된 가물막이댐 월류확률을 고려하였으며, 비용 및 피해액으로는 유수전환시설의 공사비, 가물막이댐 파괴시의 재건설비용과 지체보상금, 가물막이댐 월류시의 복구비용을 고려하였다. 이에 대한 연구결과로, 유수전환시설의 사용기간과 월류시의 복구비용이 유수전환시설의 설계 재현기간 결정에 가장 큰 영향을 미치는 것으로 나타났고, 특히 월류시의 복구비용이 작을수록 낮은 설계 재현빈도를 선택하는 것이 타당한 것으로 나타났다. 예를 들어, 유수전환시설의 사용기간이 3 ~ 5년, 복구비용이 0.5 ~ 1.0 mil USD 이하인 조건에서 가물막이시설의 최적 설계빈도는 1년 ~ 2년인 것으로 나타났다. 또한, 유수전환시설의 사용기간은 본댐의 규모와 시공기간 등을 고려하여 결정되는 사항으로 설계자가 임의 조정할 수 없지만, 복구비용은 시공 관리자에 따라 결정되는 부분으로, 적극적 홍수 피해 저감 및 복구방안을 마련하는 것이 프로젝트의 경제성을 향상시킬 수 있다는 것을 알 수 있었다. 두 번째로 프로젝트의 경제성 향상, 홍수기 댐 시공시의 안전성 확보를 위하여 홍수 조기경보시스템(Early Warning System)을 개발 및 활용하였다. 수로식(Run-of-river) 수력발전댐은 대부분 산악지역에 위치하기 때문에 국지성 강우 및 급한 지형 경사로 인하여 돌발홍수(flash flood)의 발생 가능성이 높다. 따라서 시공 중 홍수(월류) 발생을 미리 감지하고 현장에 전파할 수 있는, 수로식(Run-of-river) 수력발전댐 현장을 위한 홍수 조기경보시스템이 필요하며, 이를 리스크 인식, 모니터링 및 경보, 전파 및 연락, 반응 능력 향상의 4가지 부분으로 나누어 구축하였다. 리스크 인식 부분에서는 가물막이댐 월류 발생 상황에 대한 위험도, 취약성, 리스크를 제시하였으며, 모니터링 및 경보 부분에서는 상류 측정수위에서 유도된 현장 예상수위와 실제 현장 측정 수위를 대상으로 경보홍수위와 위험홍수위로 나누어 관리하였다. 전파 및 연락 부분에서는 현장 시공 조직을 활용하여 홍수시를 대비한 비상연락체계도(Emergency communication flow chart)를 운영하였으며, 반응 능력 향상을 위해 비상연락체계도의 팀별 Action plan을 상세화 하였다. 세 번째로 현장의 지질특성과 50여 차례 발파시험으로 현장 고유의 발파진동감쇄곡선을 도출하였으며, 이를 통해 현장의 시공성과 콘크리트 품질 확보를 동시에 달성할 수 있는 방안을 제시하였다. 콘크리트댐 공사에서는 제한된 공기 내에 공사를 완료하기 위해 사면부 굴착과 콘크리트 타설이 동시에 수행될 수밖에 없는 문제점을 가지고 있다. 그러나 신규 콘크리트 타설면 근처에서 발파를 수행하는 경우 발파로 발생되는 탄성파가 일정 수준을 초과하게 되면, 콘크리트 양생에 영향을 주게 된다. 따라서 다수의 현장 발파시험을 통해 발파거리와 최대진동속도의 상관관계 즉, 발파진동감쇄곡선을 도출함으로써 현장의 발파진동특성을 도출할 수 있었다. 또한, 기존 연구 논문들을 통해 콘크리트 재령기간 별 안전진동속도를 선정하고, 해당 안전진동속도를 초과하지 않는 범위에서 콘크리트 타설면과 발파위치의 거리에 따라 1회 발파 가능한 장약량을 산정하여 적용하였다. 이와 같은 체계적인 접근을 통해 콘크리트 타설과 발파 작업 동시 수행에 대한 논란을 해소할 수 있었다.

  • PDF

Dosimetry of $^{222}Rn$ Component in Outdoor Natural Background Radiation (자연 방사선량 중 $^{222}Rn$기여 성분 정량 해석)

  • Jun, Jae-Shik;Oh, Hi-Peel;Chae, Ha-Suk;Lee, Byung-Young;Kim, Do-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.10-17
    • /
    • 1989
  • A study for the assessment of dose given by outdoor radon to respiratory system has been carried out by making use of radon-cups containing CR-39 plastic track detectors. Detection efficiencies were determined by irradiation of the radon-cups in a standard radon chamber of known concentration. Thus determined detection factors of CR-39 plastic track detector in bare, open cup and filtered cup geometry are found to be 0.273, 0.0813 and 0.0371 $trmm^{-2}$/(37$Bqm^{-3}{\cdot}d$), respectively, which are chemically etched in 30% NaOH solution of $70^{\circ}C$ for 220 minutes. The outdoor radon concentrations measured at Taejeon(Chungnam National University) from May 1988 to March 1989 are in the range of 27.4 - 135.8 Bq/$m^3$(0.74 - 3.67pCi/l)by open cup and 16.7 - 143.9 Bq/$m^3$(0.45 - 3.89 pCi/l) by filtered cup, which yield overall annual average value of outdoor radon concentration of $70.8Bq/m^3$(1.91 pCi/l). Corresponding effective dose equivalent rate to respiratory system of ICRP standard man is assessed to be 520 nSv /h.

  • PDF

Miniaturization of UHF Planar Antenna Employing Slot-loading (Slot-loading에 의한 UHF 대역 평면 안테나의 소형화 설계)

  • Chun, Joong-Chang;Lee, Dong-Hyun;Kim, Tae-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.685-688
    • /
    • 2008
  • Planar antennas are very efficient for the use of the out-door data transmission applications due to their low-profile characteristics. But the size of the antenna in UHF band blocks the practical usage. In this paper, a miniaturized planar antenna is investigated for the application of AMR system in UHF band. The designed antenna is fabricated in the form of the microstrip patch on the FR-4 substrate. The miniaturization is achieved by slot-loading on the patch. First, effects of simple slots on the size reduction are analyzed, followed by the design using more complex slots resulting in the reduction ratio of 37.9% in 425.6 MHz and bandwidth of 3.8 MHz. The effect of epoxy coating for the protection is also investigated.

  • PDF

The Study about Applied Realities of Infiltrated Facilities for the Rainwater in the Housing Complex - With the Center of Kiheung, Sangal Kum Hwa Village - (공동 주택단지 옥외공간의 빗물침투시설 적용실태에 관한 연구 - 기흥 상갈 금화마을을 중심으로 -)

  • Kim, Do-Kyong;Park, Sung-Jun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.4
    • /
    • pp.33-42
    • /
    • 2003
  • Nowadays, according to the interests in the environmental infinity for the housing complex, there are various studies going on for setting general ideas and plans of them. And in some of the leading places are applied by the infinity of the natural environment. So, by this study, I analyzed the classification and the system of the infiltrated facilities for the rainwater and then suggested the problems about these and the studies for the generalization of the infiltrated facilities for the rainwater based on my real investigation of the center of infiltrated facilities for the rainwater in the Kiheung, Sangal Kum Hwa Village designed and builded by the Korea Housing Corporation for building housing complex with the infinity of the natural environment. I grasped the realities based on subject investigations and designs and found out the infiltrated facilities for the rainwater in the subject. Those are the porous concretes, pebbles and cobbles. The problems in the subject are supervision of these places and a shoddy and fault constructions by the ignorance and lack of recognition for the construction. These will be solved by reconsidering of the infiltrated facilities for the rainwater. The system of the infiltration is that the rainwater of the top of the building flows into the brook in the subject through the field of the subject. There must be going to be leading studies on the effect of these facilities and influence on the environment for the generalization of the infiltrated facilities for the rainwater of natural environment.

Playground Facilities for Physically Challenged Children (지체장애 아동을 위한 옥외 놀이시설)

  • 김학범;이은희
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.4
    • /
    • pp.47-65
    • /
    • 2002
  • The purpose of this paper is to study and propose playground facilities for physically challenged children to cultivate adaptability in society and advances the opportunity of participate in physical exercise. This study carried out site investigations by visiting and inspecting various facilities: a recreational walking path for physically challenged people, a care facility for physically challenged children, a special school for physically challenged children, and "Madel Park", a private-use playground for physically challenged children. The result of the site investigation found that, overall, play facilities are difficult to use for physically challenged children. In addition, because park space is often small and narrow, children who are restricted to wheelchairs find it impossible to access such facilities. By carefully inspecting each of the facilities, the author found suitable elements to apply for outside play space. These elements include the introduction of an essential slope way to allow for safe movement, the provision of special seats which support the body to outside play equipment and the adaptation of treatment room instruments that assist balance to outdoor playground facilities. On the basis of the site investigation the interview and the indoor education program for physically challenged children the author completed an outside play program. Each item in this program was classified as belonging to either a "sense play" program or and "exercise play" program. Finally, the author designed suitable play equipment for physically challenged children corresponding to each item in the exercise programs in order to research the appropriateness of the equipment to its intended use. This research is the first step. From this point the author expects that specific applications will be developed through a practical space plan and sufficient clinical experiments involving use of the new equipment.

Effect of Acid Rain on Marble Cultural Properties (대리석 문화재에 대한 산성비의 영향)

  • Kim, Sa Dug;Hwang, Jin Ju;Kang, Dai Ill
    • Journal of Conservation Science
    • /
    • v.7 no.1
    • /
    • pp.19-22
    • /
    • 1998
  • The influence of acid rain on the marble cultural properties investigated in two ways : 1) marble samples similar to that of Wongak-sa 10-story pagoda were directly exposed to rain in air at Chongro and Kwanghwamun sites; 2) marble samples under a protective facility were indirectly exposed to rain. The quantity of corrosion products and variations of calcium ion to rain were analyzed. The result shows that the corrosion qantity of the marble samples exposed directly under 1~8 mm rainfall in the Chongno and Kwanghwamun sites were similar, but those were 7.7 times higher than those indoor. Concentration of anions were higher than that of cations among the ion concentration over 40% in the early 1 mm rainfall. Calcium ion was produced over 30%. Because the monuments of marble, limestone and sandstone were affected by acid rain, it may be necessary to establish policies for the conservation on the National Treasures made of these materials.

  • PDF

Miniaturization of UHF Planar Antenna Employing Slot-loading (슬롯 장하에 의한 UHF 대역 평면 안테나의 소형화 설계)

  • Chun, Joong-Chang;Lee, Dong-Hyun;Kim, Tae-Soo;Kim, Hyun-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.6
    • /
    • pp.979-983
    • /
    • 2008
  • Planar antennas are very efficient for the use of the out-door data transmission applications due to their low-profile characteristics. But the size of the antenna in UHF band blocks the practical usage. In this paper, a miniaturized planar antenna is investigated for the application of AMR system in UHF band. The designed antenna is fabricated in the form of the microstrip patch on the FR-4 substrate. The miniaturization is achieved by slot-loading on the patch. First, effects of simple slots on the size reduction are analyzed, followed by the design using more complex slots resulting in the reduction ratio of 37.9% in 425.6 MHz and bandwidth of 3.8 MHz. The effort of epoxy coating for the protection is also investigated.