• Title/Summary/Keyword: 오차 허용 범위

Search Result 227, Processing Time 0.024 seconds

Quality Control on the BOD, COD, TN, TP of Water Quality Pollutant (수질오염물질 BOD, COD, TN, TP의 정도관리(I))

  • Park, Sun-Ku;Kim, Tae-Seung;Ryu, Jae-Kyun
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.312-317
    • /
    • 1999
  • Quality control was carried out the three analytes, BOD, COD, TN, TP of high and low concentration for thirteen laboratories. Evaluation values of Quality control was determined from average value which were made by six times test, repeatedly and periodically. This value had not only error ratio of within 5% from prepared sample value but also high precision of standard deviation, 0.44 (BOD, low concentration), 2.15 (BOD, high concentration), 0.12 (COD, low concentration), 1.63 (COD, high concentration), 0.35 (TN, low concentration), 1.99 (TN, high concentration), 0.05 (TP, low concentration), 0.14 (TP, high concentration). Upper (Lower) Warning Limit (ULWL) and Upper (Lower) Acceptance Limit (ULAL) values made from quality control chart. Three (5.30, 9.70, 5.30 mg/L) and five laboratories were over ULAL value in low and high BOD concentration, respectively. Two (41.00, 30.60 mg/L) and four laboratories were over ULAL value in low and high COD concentration, respectively. while, other eleven laboratories appeared reliable data. One laboratory (0.70 mg/L) was over ULAL at low TN concentration, while other eleven laboratories had reliable values. In case of high TN concentration, eleven laboratories were over ULAL value, it should be focuced for improvement of reliability about measurement and analysis of TN. Four (1.14, 0.45, 0.64, 1.49mg/L) and seven laboratories were over ULAL in low and high TP concentration, respectively.

  • PDF

A Study on Proposal for Systematic Development of the Inspection of Cadastral Surveying Value -the Case of Sungnam City- (지적측량 성과검사의 제도적 재선방안에 대한 연구 -성남시를 중심으로-)

  • 김욱남;박희주
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.1
    • /
    • pp.133-138
    • /
    • 1998
  • Korea's inspection of cadastral surveying value is carrying out based on cadastral law, and has to enter in cadaster after government office's final inspection of cadastral surveying of land alteration according to the request of land owner or the state. Therefore, government office has to inspect the value of surveying before arranging cadastral book, and has to confirm whether the surveying error is whithin the range of allowing one. If it is, a govenment office has to arrange the cadastral book according to resulting Value. This study investigates and analizes annual land alteration of Sungnam city and analizes the situation of government office's cadastral surving value, the number of inspectors, and equipments. As a result, this study shows the problem and provides effective basic materials, increases the efficacy of the state's cadastral surveying inspection, and minimiges land dispute.

  • PDF

Magnetic Measurement of PLS Storage Ring Prototype Dipole Magnet (방사광 가속기용 2극 전자석 특성측정 및 보정)

  • 강봉구;박기현;윤종렬;구양모
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.2
    • /
    • pp.163-168
    • /
    • 1992
  • Results of magnetic measurement of a prototype Storage Ring dipole magnet for the Pohang Light Source (PLS) are summarized. Hall probe mapping and rotating coil methods are used to measure field profiles and integrated field properties. End chamfering experiments are performed on the as-built magnet, which has four removable pole-end pieces, to meet the specifications set from beam dy-namics requirement. The corrected magnet has efficiency of 99.7% at 2.0 GeV excitation ad higher order multipole error levels less than the specifications for all excitations, showing that the magnet has appropriate properties for the PLS Storage Ring.

  • PDF

A Remote Measurement Technique for Rock Discontinuity (암반 불연속면의 원격 영상측량 기법)

  • 황상기
    • The Journal of Engineering Geology
    • /
    • v.11 no.2
    • /
    • pp.205-214
    • /
    • 2001
  • A simple automated measuring method for planar or linear features on the rock excavation surface is presented. Attitude of the planar and linear feature is calculated from 3D coordinates of points on the structures. Spatial coordinates are calculated from overlapped stereo images. Factors used in the calculation are (1) local coordinates of the left and right images, (2) the focal length of cameras, and (3) the distance between two cameras. A simple image capturing device and an image treatment routine coded by Visual Basic and GIS components are constructed for the remote measurements, The methodology shows less than 1 cm error when a point is measured from 179 cm in distance. The methodology is tested at the excavation site in PaiChai University. Remotely measured result matches well with the manual measurement within the reasonable error range.

  • PDF

Diffraction Effects of Parabolic Mild-Slope Equations in the Shadow Zone behind a Detached Breakwater (이안제 배후 차폐역에서 포물선형 완경사방정식의 회절효과)

  • 김인철
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.8 no.4
    • /
    • pp.297-304
    • /
    • 1996
  • The purpose of this study is to observe the applicability of parabolic mild-slope equations allowing relatively large angles of wave propagation based on the use of a Pade approximant or minimax approximation and also the applicability of the models with nonlinearity of diffracted waves in the shadow zone behind coastal structures. To accomplish these objectives, numerical solutions are obtained from the above parabolic models and are compared with the results from Watanabe and Maruyama's(1984) hydraulic model test on the wave field with an impermeable detached breakwater. From this study, it is found that computed wave heights increase for the nonlinear results in comparison to the linear results due to the increased diffraction effect across the geometric shadow boundary. The model with a larger aperture with respect to the principal direction was found to spread laterally to a much greater degree where spreading angle (diffraction effect) is relatively large. which causes a distortion in the overall results due to the error accumulated by the approximation of wave length.

  • PDF

Study of Effects of Measurement Errors in Damage Detection (동적 측정오차가 손상탐지에 미치는 영향에 관한 연구)

  • Kim, Ki-Ook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.3
    • /
    • pp.218-224
    • /
    • 2011
  • A modal method is presented for the investigation of the effects of measurement errors in damage detection for dynamic structural systems. The structural modifications to the baseline system result in the response changes of the perturbed structure, which are measured to determine a unique system in the inverse problem of damage detection. If the numerical modal data are exact, mathematical programming techniques can be applied to obtain the accurate structural changes. In practice, however, the associated measurement errors are unavoidable, to some extent, and cause significant deviations from the correct perturbed system because of the intrinsic instability of eigenvalue problem. Hence, a self-equilibrating inverse system is allowed to drift in the close neighborhood of the measured data. A numerical example shows that iterative procedures can be used to search for the damaged structural elements. A small set of selected degrees of freedom is employed for practical applicability and computational efficiency.

Experimental Study on the Water Content Formula of Fresh Concrete by Microwave Oven Drying Test Method (고주파 가열건조 시험방법에 의한 굳지 않은 콘크리트의 단위수량 추정식에 관한 실험적 연구)

  • Park, Min-Yong;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.2
    • /
    • pp.143-152
    • /
    • 2023
  • In this research, the microwave oven drying method was investigated as a potential accurate testing approach for determining the water content of fresh concrete. To do so, water content estimation formulas employed in three prominent oven drying test methods were selected, and the calculation principles for each equation, along with potential error factors arising during the actual testing process, were considered. Moreover, a concrete test was conducted to validate the possible error factors. Consequently, it was confirmed that estimation errors in the water content of fresh concrete can occur due to sample deviations arising during the wet screening process for creating mortar specimens or deviations in the coarse aggregate sampling quantity during the sample collection process.

KSLV-I Kick Motor System Thrust Axis Alignment (KSLV-I 킥모터 시스템 추력 축 정렬)

  • Lee, Han-Ju;Jung, Dong-Ho;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.138-142
    • /
    • 2010
  • The thrust axis alignment of the launch vehicle is very important because of the misalignment causes the unstable attitude control and results in mission failure. Generally, optical methods such as digital theodolite and laser tracker and mechanical method such as turn table method are used to align thrust axis to vehicle axis. This article deals with the simple method of thrust axis alignment of Kick Motor.

Feature Parameter Extraction for Shape Information Analysis of 2-D Moving Object (2-D 이동물체의 형태 정보 분석을 위한 특징 파라미터 추출)

  • 김윤호;이주신
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.11
    • /
    • pp.1132-1142
    • /
    • 1991
  • This paper proposed a method of feature parameter extraction for shape information analysis of moving object. In the 2-D plane, moving object are extracted by the difference method. Feature parameters of moving object are chosen area, perimeter, a/p ratio, vertex, x/y ratio. We changed brightness variation from the range of 600Lux to the 1400Lux and then determined Permissible Error range of feature parameter due to the brightness variation. So as to verify the validity of proposed method, experiment are performed with a toy car and it's results showed that decision error was less than 6%.

  • PDF

Performance Analysis for Passive Filter Considering Allowable Limits of Tolerance (오차의 허용범위를 고려한 수동형 필터의 특성 해석)

  • Kim, Jong-Gyeum;Kim, Il-Jung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.38-43
    • /
    • 2009
  • Reactors are connected with capacitors to passive filter circuits for reducing harmonics caused by power conversion application. This passive filter frequently gets out of order by voltage and current stress. Especially filter reactor has too much voltage harmonics components, its trouble rate is higher than capacitor. In this paper, we analyzed voltage and current of reactor and capacitor used for passive filter by simulation and measurement. If reactor has a tolerance on variation of reactance value, series resonance frequency is different from originally filter design frequency and parallel resonance can be generated at the close point of the former. Because filter absorbs harmonic component of non-linear load, much of harmonic voltage has been impacted on reactor.