• Title/Summary/Keyword: 오차비교

Search Result 5,264, Processing Time 0.036 seconds

Analysis of domestic water usage patterns in Chungcheong using historical data of domestic water usage and climate variables (생활용수 실적자료와 기후 변수를 활용한 충청권역 생활용수 이용량 패턴 분석)

  • Kim, Min Ji;Park, Sung Min;Lee, Kyungju;So, Byung-Jin;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.1
    • /
    • pp.1-8
    • /
    • 2024
  • Persistent droughts due to climate change will intensify water shortage problems in Korea. According to the 1st National Water Management Plan, the shortage of domestic and industrial waters is projected to be 0.07 billion m3/year under a 50-year drought event. A long-term prediction of water demand is essential for effectively responding to water shortage problems. Unlike industrial water, which has a relatively constant monthly usage, domestic water is analyzed on monthly basis due to apparent monthly usage patterns. We analyzed monthly water usage patterns using water usage data from 2017 to 2021 in Chungcheong, South Korea. The monthly water usage rate was calculated by dividing monthly water usage by annual water usage. We also calculated the water distribution rate considering correlations between water usage rate and climate variables. The division method that divided the monthly water usage rate by monthly average temperature resulted in the smallest absolute error. Using the division method with average temperature, we calculated the water distribution rates for the Chungcheong region. Then we predicted future water usage rates in the Chungcheong region by multiplying the average temperature of the SSP5-8.5 scenario and the water distribution rate. As a result, the average of the maximum water usage rate increased from 1.16 to 1.29 and the average of the minimum water usage rate decreased from 0.86 to 0.84, and the first quartile decreased from 0.95 to 0.93 and the third quartile increased from 1.04 to 1.06. Therefore, it is expected that the variability in monthly water usage rates will increase in the future.

Semi-Quantitative Analysis for Determining the Optimal Threshold Value on CT to Measure the Solid Portion of Pulmonary Subsolid Nodules (폐의 아고형결절에서 침습적 병소를 검출하기 위한 반-정량 분석을 통한 최적의 CT 임계 값 결정)

  • Sunyong Lee;Da Hyun Lee;Jae Ho Lee;Sungsoo Lee;Kyunghwa Han;Chul Hwan Park;Tae Hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.670-681
    • /
    • 2021
  • Purpose This study aimed to investigate the optimal threshold value in Hounsfield units (HU) on CT to detect the solid components of pulmonary subsolid nodules using pathologic invasive foci as reference. Materials and Methods Thin-section non-enhanced chest CT scans of 25 patients with pathologically confirmed minimally invasive adenocarcinoma were retrospectively reviewed. On CT images, the solid portion was defined as the area with higher attenuation than various HU thresholds ranging from -600 to -100 HU in 50-HU intervals. The solid portion was measured as the largest diameter on axial images and as the maximum diameter on multiplanar reconstruction images. A linear mixed model was used to evaluate bias in each threshold by using the pathological size of invasive foci as reference. Results At a threshold of -400 HU, the biases were lowest between the largest/maximum diameter of the solid portion of subsolid nodule and the size of invasive foci of the pathological specimen, with 0.388 and -0.0176, respectively. They showed insignificant difference (p = 0.2682, p = 0.963, respectively) at a threshold of -400 HU. Conclusion For quantitative analysis, -400 HU may be the optimal threshold to define the solid portion of subsolid nodules as a surrogate marker of invasive foci.

Analysis of Applicability of RPC Correction Using Deep Learning-Based Edge Information Algorithm (딥러닝 기반 윤곽정보 추출자를 활용한 RPC 보정 기술 적용성 분석)

  • Jaewon Hur;Changhui Lee;Doochun Seo;Jaehong Oh;Changno Lee;Youkyung Han
    • Korean Journal of Remote Sensing
    • /
    • v.40 no.4
    • /
    • pp.387-396
    • /
    • 2024
  • Most very high-resolution (VHR) satellite images provide rational polynomial coefficients (RPC) data to facilitate the transformation between ground coordinates and image coordinates. However, initial RPC often contains geometric errors, necessitating correction through matching with ground control points (GCPs). A GCP chip is a small image patch extracted from an orthorectified image together with height information of the center point, which can be directly used for geometric correction. Many studies have focused on area-based matching methods to accurately align GCP chips with VHR satellite images. In cases with seasonal differences or changed areas, edge-based algorithms are often used for matching due to the difficulty of relying solely on pixel values. However, traditional edge extraction algorithms,such as canny edge detectors, require appropriate threshold settings tailored to the spectral characteristics of satellite images. Therefore, this study utilizes deep learning-based edge information that is insensitive to the regional characteristics of satellite images for matching. Specifically,we use a pretrained pixel difference network (PiDiNet) to generate the edge maps for both satellite images and GCP chips. These edge maps are then used as input for normalized cross-correlation (NCC) and relative edge cross-correlation (RECC) to identify the peak points with the highest correlation between the two edge maps. To remove mismatched pairs and thus obtain the bias-compensated RPC, we iteratively apply the data snooping. Finally, we compare the results qualitatively and quantitatively with those obtained from traditional NCC and RECC methods. The PiDiNet network approach achieved high matching accuracy with root mean square error (RMSE) values ranging from 0.3 to 0.9 pixels. However, the PiDiNet-generated edges were thicker compared to those from the canny method, leading to slightly lower registration accuracy in some images. Nevertheless, PiDiNet consistently produced characteristic edge information, allowing for successful matching even in challenging regions. This study demonstrates that improving the robustness of edge-based registration methods can facilitate effective registration across diverse regions.

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF

Leukocyte count and hypertension in the health screening data of some rural and urban residents (일부 농촌과 도시의 건강선별조사 자료로 본 백혈구수와 고혈압과의 관계)

  • Lee, Choong-Won;Yoon, Nung-Ki;Lee, Sung-Kwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.3 s.35
    • /
    • pp.363-372
    • /
    • 1991
  • We used the health screening data of some rural and urban residents to examine the cross-sectional association between leukocyte count and hypertension. The 206 male and 203 female rural residents were selected by multi-stage cluster sampling method in Kyungsan-Kun area of Kyungbuk province in 1985 and 600 urban residents were selected by the same sampling method as the rural residents in Daegu city of the same province in 1986 compatible with age-sex distribution of Daegu city of 1985 census, but of whom 384 actually responded. The rest of 600 were replaced by age and sex with those who were members of the medical insurance plan visiting the health management department of the university hospital to get the biannual preventive medical checkups. Excluded in the analysis were those having hypertensive history, diseases and extreme outlying values of the screening tests, leaving 373 rural and 571 urban residents. Leukocyte count was measured with ELT-8 Laser shadow method and the unit $cells/mm^3$, Blood pressures were determined with an aneroid sphygmomanometer with pre-standardized method and hypertensives were defined as those showing systolic blood pressure more than 140mmHg and/or diastolic blood pressure more than 90mmHg. Total residents pooled (N=944) showed a significant difference between hypertensives and normotensives ($6965.93{\pm}1997.01\;vs\;6490.61{\pm}1941.32,\;P=0.00$) and in rural residents was noted the similar significant difference (P=0.03). None of significant differences were noted in any stratum stratified by residency and sex. Compared to the lowest quintile of WBC, 2/5 quintile showed odds ratio 0.99 (95% Confidence interval, Ci 0.62-1.59), 3/5 quintile 1.41 (95% CI 0.90-2.21), 4/5 quintile 1.76 (95% CI. 1.14-2.72), and highest quintile 1.80 (1.15-2.82) in the total residents. Likelihood ratio test for linear trend for it indicated a significant trend ($X^2_{trend}=5.53,\;df=1,\;P<0.05$). There were no other significant odds ratios compared to the lowest quintile of WBC in strata stratified by residency and sex. The odds ratios in total residents which had showed significant odds ratios became nonsignificant and of reduced magnitude after controlling age, frequency of smoking and drinking with multiple logistic. regression. In each stratum, it changed magnitudes of odds ratios slightly and unstably. None of the trend tests showed any significant trend. These results suggest that the Friedman et al's finding of association between leukocyte count and hypertension may be due to an statistical type I error resulting from the data dredging in an exploratory study, in which more than 800 variables were screened as possible predictors of hypertension.

  • PDF

The Precision Test Based on States of Bone Mineral Density (골밀도 상태에 따른 검사자의 재현성 평가)

  • Yoo, Jae-Sook;Kim, Eun-Hye;Kim, Ho-Seong;Shin, Sang-Ki;Cho, Si-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.67-72
    • /
    • 2009
  • Purpose: ISCD (International Society for Clinical Densitometry) requests that users perform mandatory Precision test to raise their quality even though there is no recommendation about patient selection for the test. Thus, we investigated the effect on precision test by measuring reproducibility of 3 bone density groups (normal, osteopenia, osteoporosis). Materials and Methods: 4 users performed precision test with 420 patients (age: $57.8{\pm}9.02$) for BMD in Asan Medical Center (JAN-2008 ~ JUN-2008). In first group (A), 4 users selected 30 patient respectively regardless of bone density condition and measured 2 part (L-spine, femur) in twice. In second group (B), 4 users measured bone density of 10 patients respectively in the same manner of first group (A) users but dividing patient into 3 stages (normal, osteopenia, osteoporosis). In third group (C), 2 users measured 30 patients respectively in the same manner of first group (A) users considering bone density condition. We used GE Lunar Prodigy Advance (Encore. V11.4) and analyzed the result by comparing %CV to LSC using precision tool from ISCD. Check back was done using SPSS. Results: In group A, the %CV calculated by 4 users (a, b, c, d) were 1.16, 1.01, 1.19, 0.65 g/$cm^2$ in L-spine and 0.69, 0.58, 0.97, 0.47 g/$cm^2$ in femur. In group B, the %CV calculated by 4 users (a, b, c, d) were 1.01, 1.19, 0.83, 1.37 g/$cm^2$ in L-spine and 1.03, 0.54, 0.69, 0.58 g/$cm^2$ in femur. When comparing results (group A, B), we found no considerable differences. In group C, the user_1's %CV of normal, osteopenia and osteoporosis were 1.26, 0.94, 0.94 g/$cm^2$ in L-spine and 0.94, 0.79, 1.01 g/$cm^2$ in femur. And the user_2's %CV were 0.97, 0.83, 0.72 g/$cm^2$ L-spine and 0.65, 0.65, 1.05 g/$cm^2$ in femur. When analyzing the result, we figured out that the difference of reproducibility was almost not found but the differences of two users' several result values have effect on total reproducibility. Conclusions: Precision test is a important factor of bone density follow up. When Machine and user's reproducibility is getting better, it’s useful in clinics because of low range of deviation. Users have to check machine's reproducibility before the test and keep the same mind doing BMD test for patient. In precision test, the difference of measured value is usually found for ROI change caused by patient position. In case of osteoporosis patient, there is difficult to make initial ROI accurately more than normal and osteopenia patient due to lack of bone recognition even though ROI is made automatically by computer software. However, initial ROI is very important and users have to make coherent ROI because we use ROI Copy function in a follow up. In this study, we performed precision test considering bone density condition and found LSC value was stayed within 3%. There was no considerable difference. Thus, patient selection could be done regardless of bone density condition.

  • PDF

Assessment of Nutrient Intakes of Lunch Meals for the Aged Customers at the Elderly Care Facilities Through Measuring Cooking Yield Factor and the Weighed Plate Waste (조리 중량 변화 계수 및 잔반계측법을 이용한 노인복지시설 이용자의 점심식사 영양섭취평가)

  • Chang, Hye-Ja;Yi, Na-Young;Kim, Tae-Hee
    • Journal of Nutrition and Health
    • /
    • v.42 no.7
    • /
    • pp.650-663
    • /
    • 2009
  • The purposes of this study were to investigate one portion size of menus served and to evaluate nutrient intake of lunch at three elderly care facility food services located in Seoul. A weighed plate method was employed to measure plate wastes and consumption of the menus served. Yield factors were calculated from cooking experiments based on standardized recipes, and were used to evaluate nutrient intake. One hundred elderly participated in this study for measuring plate waste and were asked to complete questionnaire. Nutrient analyses for the served and consumed meal were performed using CAN program. The yield factors of rice dishes after cooking are 2.4 regardless of rice dish types, 1.58 for thick soups, 0.60 to 0.70 for meat dishes, and 1.0 to 1.25 branched vegetable. Average consumption quantity of dishes were 235.97 g for rice, 248.53 g for soup, 72.83 g for meat dishes, 39.80 g for vegetables and 28.36 g for Kimchi. On average the food waste rate is 14.0%, indicating the second highest plate waste percentage of Kimchi (26.2%), and meat/fish dish (17.3%). The evaluation results of NAR (Nutrition Adequacy Ratio) showed that iron (0.12), calcium (0.64), riboflavin (0.80), and folic acid (0.97) were less than 1.0 in both male and female elderly groups, indicating significant differences of NAR among three facilities. Compared to the 1/3 Dietary Reference Intake (DRIs) for the elderly groups, nutrient intake analysis demonstrated that calcium (100%) and iron (100%), followed by riboflavin, vitamin A, and Vitamin B6 did not met of the 1/3 EAR (Estimated Average Requirement). For the nutritious meal management, a professional dietitian should be placed at the elderly care center to develop standardized recipes in consideration of yield factors and the elderly's health and nutrition status.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

Scalable Collaborative Filtering Technique based on Adaptive Clustering (적응형 군집화 기반 확장 용이한 협업 필터링 기법)

  • Lee, O-Joun;Hong, Min-Sung;Lee, Won-Jin;Lee, Jae-Dong
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.2
    • /
    • pp.73-92
    • /
    • 2014
  • An Adaptive Clustering-based Collaborative Filtering Technique was proposed to solve the fundamental problems of collaborative filtering, such as cold-start problems, scalability problems and data sparsity problems. Previous collaborative filtering techniques were carried out according to the recommendations based on the predicted preference of the user to a particular item using a similar item subset and a similar user subset composed based on the preference of users to items. For this reason, if the density of the user preference matrix is low, the reliability of the recommendation system will decrease rapidly. Therefore, the difficulty of creating a similar item subset and similar user subset will be increased. In addition, as the scale of service increases, the time needed to create a similar item subset and similar user subset increases geometrically, and the response time of the recommendation system is then increased. To solve these problems, this paper suggests a collaborative filtering technique that adapts a condition actively to the model and adopts the concepts of a context-based filtering technique. This technique consists of four major methodologies. First, items are made, the users are clustered according their feature vectors, and an inter-cluster preference between each item cluster and user cluster is then assumed. According to this method, the run-time for creating a similar item subset or user subset can be economized, the reliability of a recommendation system can be made higher than that using only the user preference information for creating a similar item subset or similar user subset, and the cold start problem can be partially solved. Second, recommendations are made using the prior composed item and user clusters and inter-cluster preference between each item cluster and user cluster. In this phase, a list of items is made for users by examining the item clusters in the order of the size of the inter-cluster preference of the user cluster, in which the user belongs, and selecting and ranking the items according to the predicted or recorded user preference information. Using this method, the creation of a recommendation model phase bears the highest load of the recommendation system, and it minimizes the load of the recommendation system in run-time. Therefore, the scalability problem and large scale recommendation system can be performed with collaborative filtering, which is highly reliable. Third, the missing user preference information is predicted using the item and user clusters. Using this method, the problem caused by the low density of the user preference matrix can be mitigated. Existing studies on this used an item-based prediction or user-based prediction. In this paper, Hao Ji's idea, which uses both an item-based prediction and user-based prediction, was improved. The reliability of the recommendation service can be improved by combining the predictive values of both techniques by applying the condition of the recommendation model. By predicting the user preference based on the item or user clusters, the time required to predict the user preference can be reduced, and missing user preference in run-time can be predicted. Fourth, the item and user feature vector can be made to learn the following input of the user feedback. This phase applied normalized user feedback to the item and user feature vector. This method can mitigate the problems caused by the use of the concepts of context-based filtering, such as the item and user feature vector based on the user profile and item properties. The problems with using the item and user feature vector are due to the limitation of quantifying the qualitative features of the items and users. Therefore, the elements of the user and item feature vectors are made to match one to one, and if user feedback to a particular item is obtained, it will be applied to the feature vector using the opposite one. Verification of this method was accomplished by comparing the performance with existing hybrid filtering techniques. Two methods were used for verification: MAE(Mean Absolute Error) and response time. Using MAE, this technique was confirmed to improve the reliability of the recommendation system. Using the response time, this technique was found to be suitable for a large scaled recommendation system. This paper suggested an Adaptive Clustering-based Collaborative Filtering Technique with high reliability and low time complexity, but it had some limitations. This technique focused on reducing the time complexity. Hence, an improvement in reliability was not expected. The next topic will be to improve this technique by rule-based filtering.

The Effect of Heat Shock Response on the Tumor Necrosis Factor-$\alpha$-induced Acute Lung Injury in Rats (Tumor Necrosis Factor-$\alpha$로 유도되는 백서의 급성 폐손상에 열충격반응이 미치는 효과)

  • Koh, Youn-Suck;Lim, Chae-Man;Kim, Mi-Jung;Cho, Won-Kyung;Jeoung, Byung-O;Song, Kyu-Young;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1343-1352
    • /
    • 1997
  • Background : Heat-treated cells are known to be protected from lysis by TNF, which is considered to play a central role in the pathogenesis of sepsis-induced acute lung injury. The objective of the study was to investigate the effect of heat shock response by heat-pretreatment on the acute lung injury of the rats induced by intratracheally administered TNF-$\alpha$, Methods : We intratracheally instilled either saline or TNF (R&D, 500ng) with and without heat pretreatment in Sprague-Dawley rats weighing 250~350 g. The heated rats were raised their rectal temperature to $41^{\circ}C$ and was maintained thereafter for 13 minutes at 18 h before intratracheal administration of saline or TNF. After 5 h of intratracheal treatment, lung leak, lung myeloperoxidase activity (MPO) and heat shock proteins were measured in rats. Lung leak index was defined as counts per minute of $I^{25}$ in the right lung divided by counts per minutes of $I^{25}$ in 1.0 ml of blood. All data are expressed as means ${\pm}$SE. Results : There is no difference in acute lung leak index ($0.099{\pm}0.024$ vs $0.123{\pm}0.005$) among the rats given saline intratracheally with and without heat pretreatment, but MPO activity showed a decreased tendency in heat-pretreated rats ($4.58{\pm}0.79\;U/g$) compared with heat-unpretreated rats ($7.32{\pm}0.97\;U/g$) (P=0.064). Rats administered TNF intratracheally with heat-pretreatment had decreased lung leak index ($0.137{\pm}0.012$) and lung MPO activity ($5.51{\pm}1.04\;U/g$) compared with those of heat-unpretreated and TNF-administered rats ($0.186{\pm}0.016$, $14.34{\pm}1.22\;U/g$) (P<0.05 in each). There were no significant difference of lung leak index and MPO activity between TNF-treated rats with heat-pretreatment and saline-treated rats with and without heat-pretreatment. Conclusion : The heat shock response attenuated neutrophil recruitment and acute lung leak induced by intratracheal instillation of TNF-in rats.

  • PDF