• Title/Summary/Keyword: 오일 펌프

Search Result 120, Processing Time 0.023 seconds

NVH Optimization of the Eng. Oil Pump System (엔진 오일펌프계 소음.진동 최적화)

  • Shin, Dal-Heun;Bae, Sung-Yoon;Yoo, Dong-Kyu;Kang, Koo-Tae;Kwon, O-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.923-928
    • /
    • 2007
  • The rattle noise originated from the oil-pump system was issued in developing an engine. In this paper, the major concerning factors for rattle noise are analyzed and the NVH developing process is summarized. The main factors are the tip clearance of inner/outer rotor, the clearance between oil pump housing and rotor guide and the rotor mass. Also, the optimization for oil-pump rotor whine noise is performed. The main factors of the rotor whine are the profile of the rotor, the oil pressure and the shape of oil route. This paper will present the design guidelines of the engine oil-pump system.

  • PDF

Impeller Redesign of Multi-stage Centrifugal Pumps (다단 원심펌프 임펠러의 개량 수력설계)

  • Oh, JongSik;Kim, DongSoo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.177-184
    • /
    • 2001
  • For two kinds of the multi-stage centrifugal pump with diffuser vanes and return channel vanes the meanline performance prediction is applied to get information of hydraulic performance at each internal flow station, because only flange-to-flange test curves are available. As a first step of redesign fur higher efficiency, the impeller geometry is numerically investigated in the present study. Quasi-3D inviscid loading distributions are obtained, for the two impellers, using the state-of-the-art method of impeller 3D design, which provides a guide to optimal redesign. Full 3D turbulent flow fields are thereafter analyzed, using the specialized CFD code, to confirm the redesign results. The inherent limitation of the traditional graphic method of impeller design, which most of domestic pump manufacturers are now employing, is found.

  • PDF

A Study on Performance Characteristics of Heat Exchanger for Heat Pump with R410A Refrigerant (R410A 냉매를 사용한 열펌프용 열교환기의 형상에 따른 성능특성 연구)

  • 정규하;박윤철;오상경
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.340-348
    • /
    • 2004
  • The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.

Effect of Piston Shape on the Lubrication Characteristics of Hydraulic Piston Pump and Motor (피스톤 형상이 유압피스톤 펌프$cdot$모터의 윤활특성에 미치는 영향)

  • 이정오;박태조
    • Tribology and Lubricants
    • /
    • v.10 no.3
    • /
    • pp.47-53
    • /
    • 1994
  • Thin film flow in the clearance between cylinder bore and axially moving compositeshape piston is analyzed to study the effect of piston shape on the lubrication characteristics of hydraulic piston pump and motor. It is shown that the piston shape significantly affect the distribution of fluid film pressure, lateral force acting on the piston and leakage flow rate in the clearance. And it is also shown that the composite-shape piston is more effective than the cylindrical piston under tilted condition to reduce the possibility of hydraulic locking. Therefore, the results of present study can be used usefully in the design-and manufacturing of hydraulic piston pump and motor.

Assisted Flow Rate Characteristics in Hydraulic Power Steering System (유압식 파워 스티어링 시스템의 어시스트 유량 특성)

  • Lee, Byung-Rim;Ryu, Sang-Woock;You, Chung-Jun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.1
    • /
    • pp.58-63
    • /
    • 2009
  • Flow rate of the power steering oil pump is affected by oil temperature, engine rpm and pressure of pump. In this paper, considering those conditions, approximate model expressed by flow rate characteristics between hydraulic power steering oil pump and steering gear is proposed. Oil pump displacement is considered to be 9.6cc/rev. which is adapted to mid size car. Flow rate of the oil pump is predicted from the proposed model and compared with experimental data. And catch-up is also predicted in each steering wheel speed and is compared with experimental results.

Fuel Consuming Reduction by Power Steering System Optimization (동력 조향계 최적화에 의한 연비 개선)

  • Jo, Sok-Hyun;Nam, Kyung-Woo;Kwon, O-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.3
    • /
    • pp.119-124
    • /
    • 2006
  • This paper deals with energy-saving effort in the hydraulic power steering system. Commonly, the hydraulic power steering systems are used for passenger cars and the reduction of pumping loss under non-steering condition is important to improve fuel economy. Experiments and simulations are performed simultaneously to examine the main factors to reduce the pumping loss-pressure loss and flow rate of the power steering systems. Fuel economy effect of the optimal design of power steering system is verified by vehicle test - more than 1% fuel consuming reduction is attained.

Numerical analysis of the vertical tube-in-tube ground coil heat exchanger (수직으로 매설된 이중관형 지중 열교환기에 대한 해석적인 연구)

  • 유지오;금성민;신현준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.339-348
    • /
    • 1999
  • A computer model was developed in order to predict the temperature distribution and the performance of the vertical tube-in-tube ground coil heat exchanger. This model has been validated by experimental results conducted by ORNL. The heat exchanger performance with the variation of the length is calculated and compared. As results, the heat exchanger performance is proportional to the length but the performance per unit length decreases. The minimum performance of 70m - PVC heat exchanger during cyclic operation for a week is obtained 20,054kJ/h for cooling operation and 13,915kJ/h for heating operation. And minimum temperature difference is $4.64^{\circ}C$ for cooling operation and $2.64^{\circ}C$ for heating operation. In each case, it is noted that the temperature difference between the pipe and the far-field occurs within 0.8m from the heat exchanger.

  • PDF

Development of Load apparatus for Motor (모터 부하시험을 위한 부하인가 장치 개발)

  • Lim, Byung-Ju;Park, Chang-Dae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.6
    • /
    • pp.26-32
    • /
    • 2009
  • We have constructed loading apparatuses to electrical motor with a powder brake and a oil pump for load test of a several ten kilowatt-motor and performed load test with two motors. On operating the loading apparatus with a oil pump, temperature of the oil may excessively increase and fail to operate due to dynamic energy loss of equipment in oil loop. In order to control the oil temperature, factors of the energy loss were analyzed and the quantitative loss was calculated. Load tests of motors with two loading apparatuses constructed were successfully performed and strengths of each apparatus come out on operating.

Some Factors Affecting the performance of Wind-Heat Generation System (풍력열변환시스템 성능에 미치는 요인)

  • Kim, Y. J.;Ryou, Y. S.;Kang, K. C.;Baek, Y.;Yun, J. H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.139-144
    • /
    • 2002
  • 본 연구에서 열발생탱크, 모타, 로타와 스탯, 순환펌프, 열교환기로 구성된 풍력-열변환시스템을 제작하여 열교환에 미치는 몇 가지 요인에 대하여 시험하였다. 주요결과는 다음과 같다. 가. 풍력열교환시스템은 발열부, 구동부, 열교환부로 구성하였다. 나. 열교환성능시험에서 열교환에 미치는 요인은 유체주입량 3수준, 점성유체의 종류 2수준, 로타의 졸류 3수준, 로타와 스텟의 간격 3수준으로 정하여 열교환시험을 하였다. 다. SAS GLM procedure를 사용하여 열교환량에 대한 각 처리의 효과에 대해 조사해본바 유체주입량이 열 교환량에 가장 큰 영향을 미친다는 것을 발견했다. 라. 최고열교환량은 처리조건 R3 로타, 유체주입량 110 L, 로타와 스텟의 간격 17mm, A 오일에서 발생했으며 7,800 kcal/h 가 되었다. 마. 열 변환효율을 극대화하려면 열발생탱크의 직경보다는 높이를 크게 하고 유체를 최대 높이까지 주입하는 것이 바람직하리라 사료된다.

  • PDF

Optimal Design of Gerotor with Combined Lobe Profiles (Ellipse 1-Elliptical Involute-Ellipse 2) (타원 1-타원형 인벌루트-타원 2 로브 형상의 제로터 최적 설계)

  • Kwak, Hyo Seo;Li, Sheng Huan;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.12
    • /
    • pp.1237-1244
    • /
    • 2015
  • A gerotor can be manufactured in a miniature size because it has a high discharge per cycle and a simple structure. Gerotors are widely used for the lubrication oil of an engine and as the hydraulic source of an automatic transmission. Recently, improvements in fuel efficiency and noise reduction have come to the fore in the automobile industry, and it has been necessary for better fuel efficiency to continuously improve the flow rate and noise of internal gear pumps through the optimal design of the gerotor and port shape. In this study, gerotors were generated based on the equations derived for a lobe shape with multiple profiles (ellipse 1-elliptical involute-ellipse 2). The ranges of the design parameters were considered to prevent a cusp and loop. In addition, the optimal lobe shape was obtained by determining the influence of the lobe shape on the performances (flow rate, irregularity, etc.), according to the values of the design parameters.