• Title/Summary/Keyword: 오염물질 분포

Search Result 637, Processing Time 0.027 seconds

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(III) - Contribution and distribution characteristics of air pollutants according to elemental carbon, crystalline silica, and stable isotope ratio - (대구 안심연료단지 환경오염물질 노출 평가(III) - 원소 탄소, 결정형 실리카 및 안정동위원소비를 이용한 오염원 기여율 및 분포특성 -)

  • Jung, Jong-Hyeon;Phee, Young-Gyu;Shon, Byung-Hyun;Bae, Hye-Jeong;Yang, Won-Ho;Kim, Ji-Young;Kim, Geun-Bae;Choi, Jong-Woo;Park, Sung-Jun;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.392-404
    • /
    • 2015
  • Objectives: This study measured and analyzed the concentrations of crystalline silica, elemental carbon and the contribution ratio of pollutants which influence environmental and respiratory disease around the Ansim Briquette Fuel Complex in Daegu, Korea. Methods: We analyzed the crystalline silica and elemental carbon in the air according to FTIR(Fourier Transform Infrared Spectroscopy) and NIOSH(National Institute of Occupation Safety and Health) method 5040, respectively. In addition, lead stable isotopes, and carbon and nitrogen stable isotopes were analyzed using MC-ICP/MS(Multi Collector-Inductively Coupled Plasma/Mass Spectrometer), and IRMS(Isotope Ratio Mass Spectrometer), respectively. Results: The concentration of crystalline silica in the direct exposure area around the Ansim Briquette Fuel Complex was found to be $0.0014{\pm}0.0005mg/Sm^3$, but not to exceed the exposure standards of the ACGIH(American Conference of Governmental Industrial Hygienists). In the case of the autumn, the direct exposure area was found to show a level 2.5 times higher than the reference area, and on the whole, the direct exposure area was found to have a level 1.4 times higher than the reference area. The concentration of elemental carbon in the direct exposure area and in the reference area were found to be $0.0014{\pm}0.0006mg/Sm^3$, and $0.0006{\pm}0.0003mg/Sm^3$, respectively. This study confirmed the contribution ratio of coal raw materials to residentially deposited dusts in the area within 500 meters from the Ansim Briquette Fuel Complex and the surrounding area with a stable isotope ratio of 24.0%(0.7-62.7%) on average in the case of carbon and nitrogen, and 33.9%(26.6-54.1%) on average in the case of lead stable isotopes. Conclusions: This study was able to confirm correlations with coal raw materials used by the Ansim Briquette Fuel Complex and the surrounding area. The concentration of some pollutants, crystalline silica, and elemental carbon emitted to the direct-influence area around the Ansim Briquette Fuel Complex were relatively higher than in the reference area. Therefore, we need to impose continuous and substantive reduction countermeasures in the future to prevent particulate matter and coal raw materials in the study area. It is time for the local government and authorities to prepare active administrative methods such as the relocation of Ansim Briquette Fuel Complex.

Geoacoustic characteristics of Quaternary stratigraphic sequences in the mid-eastern Yellow Sea (황해 중동부 제4기 퇴적층의 지음향 특성)

  • Jin, Jae-Hwa;Jang, Seong-Hyeong;Kim, Seong-Pil;Kim, Hyeon-Tae;Lee, Chi-Won;Chang, Jeong-Hae;Choi, Jin-Hyeok;Ryang, Woo-Heon
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.6 no.2
    • /
    • pp.81-92
    • /
    • 2001
  • According to analyses of high-resolution seismic profiles (air gun, sparker, and SBP) and a deep-drill core(YSDP 105) in the mid-eastern Yellow Sea, stratigraphic and geoacoustic models have been established and seismo-acoustic modeling has been fulfilled using ray tracing of finite element method. Stratigraphic model reflects seismo-, litho-, and chrono-stratigraphic sequences formed under a significant influence of Quaternary glacio-eustatic sea-level fluctuations. Each sequence consists of terrestrial to very-shallow-marine coarse-grained lowstand systems tract and tidal fine-grained transgressive to highstand systems tract. Based on mean grain-size data (121 samples) of the drill core, bulk density and P-wave velocity of depositional units have been inferred and extrapolated down to a depth of the recovery using the Hamilton's regression equations. As goo-acoustic parameters, the 121 pairs of bulk density and P-wave velocity have been averaged on each unit of the stratigraphic model. As a result of computer ray-tracing simulation of the subsurface strata, we have found that there are complex ray paths and many acoustic-shadow zones owing to the presence of irregular layer boundaries and low-velocity layers.

  • PDF

Salt Accumulation in Horticultural Soils of PE Film House in Chungbuk Area (충북지역(忠北地域) 시설원예재배지(施設園藝栽培地) 토양(土壤)의 염류집적(鹽類集積) 실태조사(實態調査))

  • Yuk, Chang-Soo;Kim, Jai-Joung;Hong, Soon-Dal;Kang, Bo-Goo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.26 no.3
    • /
    • pp.172-180
    • /
    • 1993
  • Chemical properties of the soils were surveyed in the field of vinyl houses concentrated in the area of Bunpyong-dong and Shinchon-dong of Cheongju, Chilgeum-dong of Chungju and Gageum-myeon of Jungweon-gun. Chungcheongbuk-do province. 1. Content of chemical component of the soil in the vinyl house was higher than in open field. In more than half of the vinyl house soils surveyed, electric conductivity was more than 4.0 mmhos/cm and available phosphate was more than 1,000ppm. 2. Contents of availble phosphate and exchangeable potassium were increased with years of cultivation and their content of accumulation in soil were in the order of Bunpyong-dong>Shinchon-dong>Gageum-myeon>Chilgeum-dong. While their mobility was comparatively low. 3. $NO_3$-N content was remarkably higher in vinyl house soil and the older in cultivation made $NO_3$-N content higher same as the case of available phosphate content. However easy leaching of $NO_3$-N through soil profile is expected due to the fact that $NO_3$-N content was rapidly decreased by removal of polyethylene film cover from the frame of house after harvest of crops. 4. It is a tendency that various chemical contents of vinyl house soils wer higher in 1992 than in 1988~1990, especially much higher from the area of Bunpyong-dong and Shinchon-dong of Cheongju. 5. Salt accumulation in vinyl house soil has been increased with continuing cultivation. Therefore amount of fertilizer application should be controlled in order to avoid salt toxicity, quality deterioration for crop and salt contamination of ground water.

  • PDF

Analysis of Fluid Flows in a High Rate Spiral Clarifier and the Evaluation of Field Applicability for Improvement of Water Quality (고속 선회류 침전 장치의 유동 해석 및 수질 개선을 위한 현장 적용 가능성 평가)

  • Kim, Jin Han;Jun, Se Jin
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2014
  • The purpose of this study is to evaluate the High Rate Spiral Clarifier(HRSC) availability for the improvement of polluted retention pond water quality. A lab scale and a pilot scale test was performed for this. The fluid flow patterns in a HRSC were studied using Fluent which is one of the computational fluid dynamic(CFD) programs, with inlet velocity and inlet diameter, length of body($L_B$) and length of lower cone(Lc), angle and gap between the inverted sloping cone, the lower exit hole installed or not installed. A pilot scale experimental apparatus was made on the basis of the results from the fluid flow analysis and lab scale test, then a field test was executed for the retention pond. In the study of inside fluid flow for the experimental apparatus, we found out that the inlet velocity had a greater effect on forming spiral flow than inlet flow rate and inlet diameter. There was no observable effect on forming spiral flow LB in the range of 1.2 to $1.6D_B$(body diameter) and Lc in the range of 0.35 to $0.5L_B$, but decreased the spiral flow with a high ratio of $L_B/D_B$ 2.0, $Lc/L_B$ 0.75. As increased the angle of the inverted sloping cone, velocity gradually dropped and evenly distributed in the inverted sloping cone. The better condition was a 10cm distance of the inverted sloping cone compared to 20cm to prevent turbulent flow. The condition that excludes the lower exit hole was better to prevent channeling and to distribute effluent flow rate evenly. From the pilot scale field test it was confirmed that particulate matters were effectively removed, therefore, this apparatus could be used for one of the plans to improve water quality for a large water body such as retention ponds.

Analysis of Concentration Variations of Long-Range Transport PM10, NO2, and O3 due to COVID-19 Shutdown in East Asia in 2020 (2020년 동아시아지역에서 COVID-19 폐쇄로 인한 장거리 이동 PM10, NO2, O3 농도 변동성 분석)

  • Kim, Yu-Kyung;Cho, Jae-Hee;Kim, Hak-Sung
    • Journal of the Korean earth science society
    • /
    • v.42 no.3
    • /
    • pp.278-295
    • /
    • 2021
  • China's shutdown due to COVID-19 in 2020 reduced air pollutant emissions, which is located on the windward side of South Korea. The positive temperature anomaly and negative zonal wind anomaly from northern Mongolia to South Korea through eastern China presented warm and stationary air masses during January and February 2020. Decreased concentrations of PM10, NO2, and O3 were measured at Seokmo-ri and Pado-ri, located in the central-western region of South Korea, due to decreased emissions in China from January to March 2020. After China's shutdown from January to March 2020, in Pado-ri, the ratio of monthly average concentrations in that period with those of PM10 and O3 in the last four years decreased by approximately 0.7-4.7% and 9.2-22.8%, respectively. In January 2020, during the Lunar New Year holidays in China, concentrations of PM10, NO2, and O3 at Seokmo-ri and Pado-ri decreased just as much as it did during the same period in the last four years. However, average concentrations in January 2020 decreased before and after the Lunar New Year holidays in China when compared with those in January of the last four years. In Seokmori, ratios of actual and predicted values (${\bar{O}_s$/M) for PM10, NO2, and O3 concentrations were calculated as 70.8 to 89.7%, 70.5 to 87.1%, and 72.5 to 97.1%, respectively, during January and March 2020. Moreover, those of Pado-ri were 79.6 to 93.5%, 67.7 to 84.9%, and 83.7 to 94.6%, respectively. In January 2020, the aerosol optical depth (AOD) data showed a higher distribution than that of the last four years due to photochemical reactions in regions from northern Mongolia to eastern China and the Korean Peninsula. However, the decrease in AOD values compared with those of the last four years was attributed to the decrease in emissions of precursors that generate secondary aerosols in China during March 2020.

Development of Marine Ecotoxicological Standard Methods for Ulva Sporulation Test (파래의 포자형성률을 이용한 해양생태독성시험 방법에 관한 연구)

  • Han, Tae-Jun;Han, Young-Seok;Park, Gyung-Soo;Lee, Seung-Min
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.2
    • /
    • pp.121-128
    • /
    • 2008
  • As an aquatic ecotoxicity test method, a bioassay using the inhibition of sporualtion of the green macroalga, Ulva pertusa, has been developed. Optimal test conditions determined for photon irradiance, pH, salinity and temperature were $100\;{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, $7{\sim}9$, $25{\sim}35\;psu$ and $15{\sim}20^{\circ}C$, respectively. The validity of the test endpoint was evaluated by assessing the toxicity of four metals (Cd, Cu, Pb, Zn) and elutriates of sewage or waste sludge collected from 9 different locations. When the metals were assayed, the $EC_{50}$ values indicated the following toxicity rankings: Cu ($0.062\;mg{\cdot}L^{-1}$) > Cd ($0.208\;mg{\cdot}L^{-1}$) > Pb ($0.718\;mg{\cdot}L^{-1}$) > Zn ($0.776\;mg{\cdot}L^{-1}$). When compared with other commonly used bioassays of metal pollution listed on US ECOTOX database, the sporualtion test proved to be the most sensitive. Ulva sporulation was significantly inhibited in all elutriates with the greatest and least effects observed in elutriates of sludge from industrial waste ($EC_{50}=6.78%$) and filtration bed ($EC_{50}=15.0%$), respectively. The results of the Spearman rank correlation analysis for $EC_{50}$ data versus the concentrations of toxicants in the sludge presented a significant correlation between toxicity and four heavy metals(Cd, Cu, Pb, Zn). The method described here is sensitive to toxicants, simple to use, easy to interpret and economical. It is also easy to procure samples and maintain cultures. The present method would therefore probably make a useful assessment of aquatic toxicity of a wide range of toxicants. In addition, the genus Ulva has a wide geographical distribution and species have similar reproductive processes, so the test method would have a potential application worldwide.

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(II) - Concentration distribution and exposure characteristics of TSP, PM10, PM2.5, and heavy metals - (대구 안심연료단지 환경오염물질 노출 평가(II) - TSP, PM10, PM2.5 및 중금속 농도분포 및 노출특성 -)

  • Jung, Jong-Hyeon;Phee, Young-Gyu;Lee, Jun-Jung;Oh, In-Bo;Shon, Byung-Hyun;Lee, Hyung-Don;Yoon, Mi-Ra;Kim, Geun-Bae;Yu, Seung-do;Min, Young-Sun;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.380-391
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter pollution and its effect on health of residents living near Ansim Briquette Fuel Complex and its vicinities. Also, this study measured and analyzed the concentration of TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals which influences on the environmental and respiratory disease in Ansim Briquette Fuel Complex, Daegu, Korea. Methods: In this study, we analyzed various environmental pollutants such as particulate matter and heavy metals from Ansim Briquette Fuel Complex that adversely affected local residents's health. In particular, we verified the concentration distribution and characteristics of exposure for TSP, $PM_{10}$, and $PM_{2.5}$ among particulate matters, and heavy metals(Cd, Cr, Cu, Mn, Ni, Pb, Fe, Zn, and Mg). In that regard, the official test method on air pollution in Korea for analysis of particulate matter and heavy metal in atmosphere were conducted. The large capacity air sampling method by the official test method on air pollution in Korea were applied for sampling of heavy metals in atmosphere. In addition, we evaluated the concentration of seasonal environmental pollutants for each point of residence in Ansim Briquette Fuel Complex and surrounding area. The sampling measured periods for air pollutants were from August 11, 2013 to February 21, 2014. Furthermore, we measured and analyzed the seasonal concentrations(summer, autumn and winter). Results: The average concentration for TSP, $PM_{10}$, and $PM_{2.5}$ by direct influence area at Ansim Briquette Fuel Complex were 1.7, 1.4 and 1.9 times higher than reference region. In analysis results of seasonal concentrations for particulate matter in four direct influence and reference area, concentration levels for winter were generally somewhat higher than concentrations for summer and autumn. The average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were $0.0008{\pm}0.0004{\mu}g/Sm^3$, $0.0141{\pm}0.0163{\mu}g/Sm^3$, $0.0248{\pm}0.0059{\mu}g/Sm^3$, $0.0026{\pm}0.0011{\mu}g/Sm^3$, $0.0272{\pm}0.0084{\mu}g/Sm^3$, $0.4855{\pm}0.1862{\mu}g/Sm^3$, and $0.3068{\pm}0.0631{\mu}g/Sm^3$, respectively. In particularly, the average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were 1.9, 3.6, 2.1, 1.9, 1.4, 2.6, and 1.2 times higher than reference area, respectively. The continuous monitoring and management were required for some heavy metals such as Cr and Ni. Moreover, the average concentration in winter for particulate matter in direct influence area at Ansim Briquette Fuel Complex were generally higher than concentrations in summer and autumn. Also, average concentrations for TSP, $PM_{10}$, and $PM_{2.5}$ were from 1.5 to 2.0 times, 1.2 to 1.8 times, and 1.1 to 2.3 times higher than reference area, respectively. In results for seasonal atmospheric environment, TSP, $PM_{10}$, $PM_{2.5}$, and heavy metal concentrations in direct influence area were higher than reference area. Especially, the concentrations in C station were a high level in comparison with other area. Conclusions: In the results, some particulate matters and heavy metals were relatively high concentration, in order to understand the environmental pollution level and health effect in surrounding area at Ansim Briquette Fuel Complex. The concentration of some heavy metals emitted from direct influence area at Ansim Briquette Fuel Complex were relatively higher than reference area. In particular, average concentration for heavy metals in this study were higher than average concentrations in air quality monitoring station for heavy metal for 7 years in Deagu metropolitan region. Especially, the residents near Ansim Briquette Fuel Complex may be exposed to the pollutants(TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals, etc) emitted from the factories in Ansim Briquette Fuel Complex.