• Title/Summary/Keyword: 오염된 공기

Search Result 882, Processing Time 0.032 seconds

Anti-wrinkle Effect of Morinda citrifolia (Noni) Extracts (노니 추출물의 주름개선 효과연구)

  • Lee, Jung-Noh;Kim, Sang-Woo;Yoo, Young-Kyoung;Lee, Ghang-Tai;Lee, Kun-Kook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.32 no.4 s.59
    • /
    • pp.227-231
    • /
    • 2006
  • Wrinkle formation is mainly attributed to the environmental factors such as UV rays, air pollution, smoking and stress etc. Especially, UV rays induce premature skin aging which is characterized by deep wrinkle, leathery dryness etc. Recently, researches on the wrinkle formation and its prevention have been the main theme in cosmetics fields. We have studied the various plant extracts having anti-wrinkle effects and finally showed that Noni (Morinda citrifolia) extracts have the efficacy of promoting the type I collagen synthesis in normal human fibroblast, using PICP assay. We purified one active compound from Noni extracts and identified its structure. It was identified as 6,7-Dimethoxy-2H-1-Benzopyran-2-one; scopoletin by $^1H-NMR,\;^{13}C-NMR,$ IR, Mass analysis. Scopoletin increased collagen synthesis in a dose dependent manner (89.5% at $0.2{\mu}g/mL$). In order to verify the anti-aging effectiveness of the cream containing 3% noni extracsts, we performed the in vivo test with some female volunteers for 12 weeks. It reduced the signs of aging, especially face wrinkles. From these results, we conclude that the noni extracts could be used as an useful anti-wrinkle agent.

Hierarchical Analysis of the Application of U-Eco City Services in Urban Space -Focused on the Service Classification by Planning Factors and its Spatial Adaptability - (U-Eco City 서비스의 공간위계별 적용가능성 분석 -계획요소별 서비스 분류와 공간단위 적용성을 중심으로-)

  • Lee, Sangho;Leem, Yountaik;Kim, Heeyoung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.11
    • /
    • pp.458-468
    • /
    • 2012
  • The purpose of this study is to define U-Eco City services and to analyze the possibility and easiness of application in urban space. The most significant meaning of this study is that these results could be used as the design and planning guidelines for integrated U-Eco City. This study progress as follows; First, U-Eco City concept and their services were defined and the spatial units of U-Eco City were distinguished through literature review. Second, U-Eco City spaces are classified into four levels such as building, street, facility and district. Finally, the application of U-Eco city services was analyzed together by the statistical technique of cross-tabulation. 35.7% of U-city services was serviced in urban district and 38.8% of Eco City services was applied to Building. U-City and/or Eco city services were adapted differently according to the urban spatial hierarchy. Those services should be applied in terms of the characteristics of urban space in designing and planning U-Eco City.

Concentrations of Criteria Pollutants in Indoor and Ambient Air of Public Facilities in Taegu Area (대구지역 공중이용시설의 실내 $\cdot$ 외 공기 중 기준성오염물질의 농도)

  • 송희봉;민경섭;한개희;김종우;백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.429-439
    • /
    • 1996
  • A comprehensive air quality monitoring was carried out in this study to investigate the concentrations of criteria air pollutants in indoor and outdoor air of public facilities in Taegu area. Four different kinds of public facilities were seleced as sampling sites, which are underground stores, stations & terminals, general hospitals, and department stores. Each group of the public facilities was consisted of three different sampling sites. As a consequence, a total of 12 different sampling sites were surveyed throughout this study. Sampling was conducted simultaneously indoors, three times per day (in the morning, afternoon, and evening) and four times per year (spring, summer, fall, and winter) at each sampling site during the period of October 1994 to July 1995. A range of criteria pollutants were measured in order to obtain a broad profile of indoor and ambient air quality, including total suspended particles (TSP), carbon monoxide (CO), carbon dioxide ($CO_2$), formaldehyde (HCHO), sulfur dioxide ($SO_2$), and nitrogen dioxide ($NO_2$). In addition, temperature, relative humidity, and air current were measured on site together with those air pollutants. Results of this study indicated that the indoor levels of TSP, CO, $SO_2, and NO_2$ appeared to be generally higher in stations/terminals and underground stores than those in department stores and hospitals. However, HCHO and $CO_2$ were found to have higher levels in the department stores and hospitals than other places, indicating that the effects of indoor sources for these pollutants are significantly different from other combustion related pollutants such as TSP, CO, and $SO_2$. It was also found that there are marked seasonal and daily variations both in indoor and outdoor air quality. In general, combustion related pollutants such as CO, $SO_2$ and $NO_2$ showed a typical pattern of higher levels in winter than insummer, and also higher in the morning and/or in the evening than in the afternoon. However, the seasonal and daily patterns of HCHO appeared to be opposite to the combustion related pollutants, i.e., higher both in summer and in the afternoon, implying the effect of temperature on the volatilization from indoor sources of HCHO. Results of correlation analyses between indoor and outdoor air quality also indicated that the effects of outdoor sources on the indoor levels of TSP, $SO_2$, CO, and $NO_2$ and much significant, whilst no significant correlations between indoor and outdoor levels were found for HCHO and $CO_2$.

  • PDF

Pre-treatment of River Water Using Biological Aerated Filtration (호기성 생물여과 공정을 이용한 하천수 전처리)

  • Choi, Dong-Ho;Choi, Hyung-Joo;Bae, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.276-285
    • /
    • 2006
  • When polluted stream water was treated with biological aerated filter(BAF) in pilot plant, all operation with 90, 60, 45 and 30 min of EBCT at fixed $0.1m^3air/m^2min$ of aeration showed 80% or higher treatment efficiency of particle materials(SS, turbidity and Chl.-a) and 85% or higher efficiency of ammonia nitrogen removal. It was thought that, in case of BOD, biological stability may sufficiently be assured with BAF because grade III or IV inflow water was changed to grade I for outflow water. In case of $COD_{Mn}$, about 60% of removal efficiency was found. When the mechanism of the result was investigated, about 30% of COD materials was produced by algae clogged in the reactor. There was almost no biological decomposition because specific substrate utilization rate of algogenic organic materials were $0.0245mg{\cdot}COD_{Mn}/mg{\cdot}VSS{\cdot}day$, thus partial backwashing(washing the media in 1 m upper of the reactor once a day) was required. It is thought that elevation of removal rate about 10% of $COD_{Mn}$ and 5.5% of $BOD_5$ could be obtained with partial backwashing resulting in assurance of biologically more stable raw water and that saving backwashing water may be significant.

A Survey on Characteristics of Distribution for Indoor Air Pollutants in Museum Environments (박물관내 실내공기오염물질의 분포 특성 실태조사)

  • Kim, Yoon-shin;Roh, Young-man;Yoon, Young-hun;Lee, Cheol-min;Kim, Ki-yeon;Kim, Jong-cheol;Jeon, Hyoung-jin;Sim, In-suk
    • 보존과학연구
    • /
    • s.28
    • /
    • pp.91-104
    • /
    • 2007
  • The goal of this study was to provide basic data for arrangement of management in museum environment. We investigated characteristics of distribution on indoor air pollutants at exhibition halls and storages in museums between July and August, 2007. The monitoring carried out at three cultural sites, Pusan, Daejeon and Kyungjoo which is possessed their own exhibition hall and storage in Museums. We adopt the several pollutants for this survey such as $PM_{10}$, $PM_{2.5}$ $CO_2$, Formaldehyde, TBC, CO, $NO_2$, Rn, VOCs, $O_3$ and followed the standard method of Ministry of Environment, Korea for sampling and analysis, respectively. The results of this survey revealed that average concentration of $PM_{10}$ and $PM_{2.5}$ in storages were $117.3{\mu}g/m^3$ and $92.6{\mu}g/m^3$, respectively. The average concentration in storages of gases pollutants and microorganism such as $CO_2$, Formaldehyde, $NO_2$, Rn, TVOC, $O_3$, and TBC showed as: 788.8ppm, $30.7{\mu}g/m^3$, 0.4ppm, 6.4ppb, $1.3pCi/{\ell}$, $1,374.9{\mu}g/m^3$, 2.4ppb, and $119.4cfu/m^3$, respectively. In addition, average concentration of $PM_{10}$ and $PM_{2.5}$ in exhibition halls were $49.5{\mu}g/m^3$ and $56.1{\mu}g/m^3$, respectively. The average concentration in exhibition halls of gases pollutants and microorganism such as $CO_2$, Formaldehyde, $NO_2$, Rn, TVOC, $O_3$, and TBC showed as: 475.2ppm, $94.1{\mu}g/m^3$, 0.3ppm, 12.4ppb, $0.3pCi/{\ell}$, $1,179.1{\mu}g/m^3$, 5.2ppb, 2.4ppb, and $24.8cfu/m^3$, respectively.

  • PDF

Species Identification and Weathering of Wooden Striker on the Divine Bell of King Songdok (성덕대왕신종(聖德大王神鍾) 당목(撞木)의 수종(樹種)과 열화(劣化))

  • Kang, Aekyung
    • Conservation Science in Museum
    • /
    • v.4
    • /
    • pp.71-78
    • /
    • 2003
  • The wooden striker on the Divine Bell of King Seongdeok was examined to identify the species of the wood and the outdoor wood weathering caused by solar light, moisture, temperature and air. The species of the wooden striker was identified to Zelkova serrata. When observed the striker with naked eyes, the results were surface discoloration (graying), cracking and roughness. In order to examine the morphological changes according to deterioration type, the specimen were separated to three part(I, II,III-spot). The I-spot was discolored to gray and at the same time entirely covered with dust. So the observation was impossible. The II-spot was also discolored but its texture could be observed. On it could observe numerous fungal hypae and dirts like dust flown into the cell lumens. The cell wall has been so weakened by weathering that it lost the physical intensity. This have made microchecks and splits on the cell wall. Although fungal hypae covered the cell, they did not result in wood decay. The III-spot, located just 0.5 mm below the surface, was maintaining the natural red-brown color of the wood. Its cell wall was similar to that of sound wood. These changes are different from wood decay, and limited only to the surface of the striker-less than or equal to 0.5 mm below.

A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter (반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(I))

  • Kwon, Young-Hyun;Kim, Jin-Uk;Jung, Yu-Jin;Kim, Min-Choul;Lee, Jae-Jeong;Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4656-4663
    • /
    • 2010
  • In this study, the 3D computational fluid dynamics (CFD) was performed in relation to the internal fluid characteristics, flow distribution, air mean ages, and residence time for the development of the most optimal model in the complex post-disposal device. As it is expected that a channeling (drift) would be made by the semi-dry reactor due to the large difference in the flow distribution by the compartment in the bag filter, a structural improvement should be urgently made for more uniformed flow distribution in the bag filter. In addition, it showed the possibility that the velocity field and distribution characteristics of the residence time could be improved through a modification to inlet structure of the spray dryer reactor. The complex post-disposal device, modified and supplemented with this analysis, integrated the semi-dry reactor and the bag filter in a single body, so it follows that the improvement can make the device compact, the installation area, the operation fee, and management more convenient.

The Realization on GAS Sensor Module for Inteligent Wireless Communication (지능형 무선통신용 가스 센서 모듈 구현)

  • Kim, Hyo-Chan;Weon, Young-Su;Cho, Hyung-Rae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.6
    • /
    • pp.123-132
    • /
    • 2012
  • Gas sensors has been used very differently that depending on following purposes; Automotive (exhaust gas, fuel mixture gas, oxygen, particulates), agriculture / food industry (fresh, stored, CO2, humidity, NH3, nitrogen oxide gas, organic gas, toxic gas emitted from pesticides and insecticides), industrial / medical (chemical gas, hydrogen, oxygen and toxic gases), military (chemical weapon), environmental measurements (CO and other air pollution consisting of sulfur and nitrogen gas), residential (LNG, LPG, butane, indoor air, humidity). The types of industrial toxic substances are known about 700 species and many of these exist in gaseous form under normal conditions. he multi-gas detection sensors will be developed for casualties that detect the most important and find easy three kinds of gases in marine plant; carbon dioxide(CO2), carbon(CO), ammonia(NH3). Package block consists of gas sensing device minor ingredient, rf front end, zigbee chip. Develope interworking technology between the sensor and zigbee chip inside a package. Conduct a performance test through test jig about prototype zigbee sensor module with rf output power and unwanted emission test. This research task available early address when poisonous gas leaked from large industrial site and contribution for workers' safety at the enclosed space.

A Study on Optimal Parameter Selection for Health Monitoring of Turboprop Engine (PT6A-62) (터보프롭엔진(PT6A-62)의 성능저하 진단을 위한 최적 계측 변수 선정에 관한 연구)

  • 공창덕;기자영;장현수;오성환
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.4
    • /
    • pp.87-97
    • /
    • 2000
  • A steady state performance simulation and diagnostics program for the turboprop engine (PT6A-62), which is the power plant of the first developed military basic trainer KT-1 in Republic of Korea, was developed. The developed steady state performance analysis program was evaluated with the performance data provided by the engine manufacturer and with analysis results of GASTURB program, which is well known for the performance simulation of gas turbines. Performance parameters were discussed to evaluate validity of the developed program at various cases such as altitude, flight velocity and part load variation. GPA(Gas Pass Analysis) allows engine performance deterioration to be identified at the module level in terms of reduction in component efficiencies and changes in mass flow. In order to find optimal instrument set to detect the physical faults such as fouling, erosion and corrosion, a gas path analysis approach is utilized. This study was performed in two cases for selection of optimal measurement parameters. One case was considered with the effect of instrument number by changing independent parameter number. The other case was performed with selection of independent parameter set. According to the analysis results, the optimal measurement parameters selected were eight dependent variables such as shaft horsepower, fuel flow rate, compressor exit pressure and temperature, compressor turbine inlet pressure and temperature and power turbine inlet pressure and temperature.

  • PDF

The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation (다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사)

  • Joen, Jeong-In;Lee, Hye-Won;Choi, Hyun-Jin;Jeon, Hyung-Jin;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.