• Title/Summary/Keyword: 오염된 공기

Search Result 883, Processing Time 0.036 seconds

THE NITROUS OXIDE CONCENTRATION IN BREATHING ZONE ACCORDING TO SCAVENGING METHODS DURING DEEP SEDATION OF PEDIATRIC DENTAL PATIENTS (소아치과 환자의 깊은 진정시 호기가스 제거 방법에 따른 호흡대역에서 Nitrous Oxide 농도 변화)

  • Lee, Chung-Won;Yoon, Hyung-Bae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.124-131
    • /
    • 2003
  • The concentration of nitrous oxide in dental environment has increased especially in pediatric department. In pediatric department frequently met the behavior disordered patients who need the deep sedation. As the deeply sedated patients could not respond well to verbal command, the amount of mouth breathing would be increased especially with mouth prop which backward transposition of mandible. Inhalation of low concentration of nitrous oxide for a long duration has caused various side effects such as spontaneous abortion and inhibition of methionine synthetase activity which is harmful to DNA synthesis. For evaluation of factors of mouth breathing during deep sedation. The author measured the concentration of nitrous oxide in breathing zone by the change of the scavenging methods. One is drain the gas through the tail part of reservoir bag of Jackson Ree's system naturally. Another is scavenge from tail portion of reservoir bag with negative pressure. Last one is scavenge from nasal mask with negative pressure. The nitrous oxide concentration in breathing zone was the lowest in nasal part drainage but high above the recommended concentration of NIOSH. The order of nitrous concentration in breathing zone was: natural drainage, tail part with negative pressure, nasal part with negative pressure. This would reflect the order of resistance of nasal airway and showed the amount of mouth breathing. From the above experiment, the resistance of nasal airway by the increment of gas flow in corrugating tube and reservoir bag would be one of the causative factors of mouth breathing in deeply sedated patients.

  • PDF

The syudy of reaction kinetics in the thermophilic aerobic digestion process of piggery wastewater (축산폐수의 고온호기성 소화공정에서의 반응동력학 연구)

  • Kim, Yong-Kwan;Kim, Seok-Won;Kim, Baek-Jae
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.11a
    • /
    • pp.97-102
    • /
    • 2007
  • The piggery wastewater is the major source of the water pollution problem in the rural area. The treatment alternatives for piggery wastewater are limited by the characteristics of both high organic and nitrogen(N) content. In order to investigate an efficient N removal system, the thermophilic aerobic digestion process was examined. The experiment was investigated organic and nitrogen removal efficiency at various HRTs and air supply volume. The results of semi-continuous experiment indicated that a higher removal of the soluble portion of COD was achieved with the longer HRTs. However, the inert portion of COD in piggery wastewater was not much changed by thermophilic aerobic digestion. In addition, with the higher HRT of 3 days, up to 79% of NH4-N removal efficiency was achieved. Lower the HRTs, a decrease of NH4-N removal was founds. The gas samples from the lab reactor were analyzed along with the N content in influent and effluent. The N2O formation in our system indicates a novel aerobic deammonification process occurred during the thermophilic aerobic digestion. Both N02 and N03 were not presented in the effluent of thermophilic aerobic digester. With the HRT of 3 days, 36.4% of influent N(or 57.5% removal N) was aerobically converted to N2O gas. The ammonium conversion to N2O gas significantly decrease to 4.5% at low HRT of .05 day..

  • PDF

A Study on Changes in Indoor Air Pollution by Educational Activities -Centering on Newly-Established Elementary Schools- (교육활동에 따른 실내오염도 변화에 관한 연구 -신설 초등학교를 중심으로-)

  • Jeon, Seok-Jin
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.2
    • /
    • pp.66-90
    • /
    • 2007
  • The purpose of this study is to measure and analyze primary causes of indoor air pollution, including carbon dioxide, minute dust, and total volatile organic compounds, for each room before the beginning of a class through the time of discharge after the end of the class in general classrooms, computer rooms, and science rooms of three newly-established schools that opened in 2006, examine properties of indoor air environment in each room by educational activities at school, and determine effective management schemes; the results of this study can be summarized as follows: 1) As for implications for each item found in the mean for each place, since minute dust (PM10) was more likely to occur in time slots full of students' activities, such as a traveling class and a recess, than in the middle of a class and could be expected fully, it is necessary to make a scheme for cleaning in order to reduce minute dust within a room, for example, by usually using a vacuum cleaner indoors. 2) While carbon dioxide was expected to vary with the differences in the amount of breath between higher-graders and lower-graders in a general classroom but showed insignificant difference by grades, showing differences in pollution by four times at a maximum according to the opening of a window as expected, it is necessary to implement artificial or natural ventilation and take a positive measure, for example, by presenting a concrete ventilation scheme, in order to improve indoor air pollution at a room practice. 3) Total volatile organic compounds were found to exceed the standard by more than twice in general classrooms, science rooms, and computer rooms of the schools because of building materials, furnitures including desks and chairs, panels and boards for environment beautification, and items which could be detected even from students' clothes; while a field directly-reading tool was used, obtaining high reliability for the results, it is necessary to apply an analytical method based on process test separately for actual correct measurement if a significantly great amount of total volatile organic compounds appear as compared with other schools due to measuring expenses and consecutive measurements. 4) Since formaldehyde (HCHO) was generally found to exceed the standard in general classrooms, science rooms, and computer rooms, it is necessary to establish and operate a ventilator during a class in a computer room which requires airtightness and a science room in which an organic compound should be used for a class.

  • PDF

Stabilization of Soil Moisture and Plant Growth on a Botanical Biofilter with a Wick-Typed Humidifying Apparatus (심지형 가습장치를 이용한 식물바이오필터의 토양수분 및 식물 생육의 안정성)

  • Kim, You Na;Chun, Man Young;Lee, Chang Hee
    • Korean Journal of Plant Resources
    • /
    • v.29 no.5
    • /
    • pp.579-587
    • /
    • 2016
  • The final goal of this research is to develop a miniaturized botanical biofilter using a wick-typed automatic humidifier for stabilizing soil moisture content (SMC) and purifying indoor air pollutants by the biofilter. This new biofilter equipped with wick-typed automatic humidifier was manufactured as more compacted design removing an absorption tower-typed humidifier compared with the previous big-sized biofilter made in 2015. This study was performed to compare changes of SMCs among floors depending on the number of wicks installed on the humidifier within the novel biofilter, and to compare changes of SMCs and plant growth parameters before and after planting Spathiphyllum wallisii ‘Mauna Loa’ on the biofilter. SMCs among floors depending on the number of wicks were similar, and all regression lines of SMCs showed almost horizontal lines because of long-term stability on SMCs. Comparing plant growth parameters of S. wallisii ‘Mauna Loa’ before planting and at 30 days after planting on the biofilter, all growth parameters were not statistically significant. Thus, SMCs of the biofilter were more stabilized using this humidifying apparatus regardless of the number of wicks than the previous biofilter using absorption tower-typed humidifying apparatus.

Optimum Monitoring Parameters for the Safety of Mechanical Seals (미캐니컬 씰의 안전운용 감시를 위한 최적 계측인자)

  • Soon-Jae Lim;Man-Yong Choi
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.214-219
    • /
    • 1997
  • The mechanical seals, which are installed in rotating machines like pump and compressor, are generally used as sealing devices in the many fields of industries. The failure of mechanical seals such as leakage, crack, breakage, fast and severe wear, excessive torque, and squeaking results in big problems. To identify abnormal phenomena on mechanical seals and to propose the proper monitoring parameter for the failure of mechanical seals, sliding wear experiments were conducted. Acoustic emission, torque, and temperature were measured during experiments. Optical microstructure was observed for the wear processing after every 10 minute sliding at rotation speed of 1750 rpm and scanning electron microscopy was also observed. Except for the initial part of every experiment, the variation of acoustic emission was well coincided with torque variation during the experiments. This study concludes that acoustic emission and torque are proper monitoring parameters for the failure of mechanical seals. The intensity of acoustic emission signals is measured in root mean square voltage. Temperature of sealing face will be used as a parallel parameter for increasing the reliability of monitoring system.

  • PDF

Simultaneous Reduction of CH4 and NOx of NGOC/LNT Catalysts for CNG buses (CNG 버스용 NGOC/LNT 촉매의 CH4와 NOx의 동시 저감)

  • Seo, Choong-Kil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.167-175
    • /
    • 2018
  • Natural gas is a clean fuel that discharges almost no air-contaminating substances. This study examined the simultaneous reduction of $CH_4$ and NOx of NGOC/LNT catalysts for CNG buses related to the improvement of the $de-CH_4/NOx$ performance, focusing mainly on identifying the additive catalysts, loading of the washcoat, stirring time, and types of substrates. The 3wt. % Ni-loaded NGOC generally exhibited superior $CH_4$ reduction performance through $CH_4$ conversion, because Ni is an alkaline, toxic oxide, and exerts a reducing effect on $CH_4$. A excessively small loading resulted in insufficient adsorption capacity of harmful gases, whereasa too high loading of washcoat caused clogging of the substrate cells. In addition, with the economic feasibility of catalysts considered, the appropriate amount of catalyst washcoat loading was estimated to be 124g/L. The NOx conversion rate of the NGOC/LNT catalysts stirred from $200^{\circ}C$ to $550^{\circ}C$ for 5 hours showed 10-15% better performance than the NGOC/LNT catalysts mixed for 2 hours over the entire temperature range. The NGOC/LNT catalysts exhibitedapproximately 20% higher $de-CH_4$ performance on the ceramic substrates than on the metal substrates.

A Study on Airborne Microbes Contamination that Influences on Nosocomial Infection (병원내 감염에 영향을 미치는 공기오염 상태에 대한 조사 연구)

  • 최영희;박정호;윤혜상;문영숙
    • Journal of Korean Academy of Nursing
    • /
    • v.12 no.1
    • /
    • pp.39-52
    • /
    • 1982
  • Nosocomial infection is important in the management of the nursing care and has been found to be related with the airborne microbes contamination. The purpose of this study is to identify the differences of the airborne microbes between hospitals, nursing units, days and times and to identify the difference in the types of microorganisms between hospitals, nursing units, days and times. This study was conducted from May 25, to July 10, 1981, according to R. Koch's methods for quantative samplings of airborne microbes and the results of this study were reviewed in a statistical method. The following conclusions were obtained: 1. There was a significant difference in the types of airborne microbes between 8 hospitals (F=5.0491, p<0.01) 2. There was a significant difference in the types of airborne microbes between surgical, medical, nursery, 1.C.U., operating theatre and outpatient nursing unit. (F=2.1764, p<0.05) 3. There was not a significant difference in the types of airborne microbes between Monday, Thursday and Saturday (F= 1.6365, p>0.05) 4. There was a significant difference in the types of airborne microbes between AM 7 : 00, AM 11:00 and PM 3 : 00. (F=7.2951, p<0.01) 5. 4061 colonies were divided into more 48 types and the classification was as follows. gram positive cocci (2024 colonies) 49.3% gram positive bacillus (1211 colonies) 29.8% gram negative bacillus (577 colonies) 14.2% fungus(200colonies) 4.9% gram negative cocci (41 colonies) 1.0% other's(8 colonies) 0.3% 6. There was a significant difference of airborne microbes between 8 hospitals. (F=7.7943, P<0.01) 7. There was not a significant difference of airborne microbes between 6 nursing units. (F= 1.8461, P>0.05) outpatient nursing unit : 12.6 colonies surgical nursing unit. 10.4 colonies Medical nursing unit : 9.8 colonies nursery nursing unit : 9.4 colonies operating theatre nursing unit:8.2 colonies Intensive care nursing unit : 7.8 colonies 8. There was not a significant difference of airborne microbes between Monday, Thursday and Saturday. (F=1.4371, p>0.05). Saturday : 11.0 colonies Monday : 9.1 colonies Thursday : 9.1 colonies 9. There was a significant difference of airborne microbes between A. M. 7 ; 00, A. M. 11 : 00 and P .M. 3:00 (F=7.6658, p<0.05) P. M. 3 : 00 : 12.2 colonies A. M. 11 : 00 : 10.0 colonies A. M. 7 : 00 : 7.1 colonies.

  • PDF

Study on Design Technology of Heat Pump Cycle for High Temperature Performance (고온 생산용 열펌프 사이클 설계)

  • Kim, Jong-Ryul;Kim, Seok-Young;Kim, Yong-Min;Lee, Kong-Hoon;Kim, Ook-Joong;Yi, Sung-Chul;Jung, Chi-Young;Kim, Jong-Ryeol
    • Journal of Energy Engineering
    • /
    • v.19 no.4
    • /
    • pp.228-233
    • /
    • 2010
  • About 55% of total energy is consumed in the industrial division. The industrial heat pump application will show magnificent energy saving effect as well as higher cost efficiency because of larger energy consuming volume of each facility and longer operation hour and higher stability against seasonal temperature change. Over 90% of dryer for industrial usage has hot wind heat source and hot wind dryer is the representative type covering 68.7% while its 30 ~ 50% lower heat efficiency causes lots of energy loss by exhaust air. Re-usage of exhaust air can improve energy efficiency of dryer because 68% heat energy or 78% of hot air lose in exhaust air. Therefore, high temperature heat pump dryer can be the best alternative. Comparing to the existing dryer with 30% ~ 50% energy efficiency, newly developing high temperature heat pump dryer will enhance energy efficiency up to 60% ~ 80% efficiency. In this paper, heat pump system for high temperature was designed, constructed and tested. The results have shown that system COPh is estimated as 3.3.

Emission Characteristics of Volatile Organic Compounds by Humidifier with Using Hinoki Cypress Extracts (편백잎추출수의 실내 가습시 휘발성유기화합물 방출 특성)

  • Lee, Min;Park, Sang-Bum;Lee, Sang-Min;Lee, Hee-Young;Kil, Duck-Han
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.747-757
    • /
    • 2014
  • Since the air contamination by air pollutants from indoor construction materials and daily supplies has been increased in recent decades, the public interest of using environmentally friendly products and improving indoor air quality also attracted much attention. As known as effects of phytoncide, it has been used in construction materials and daily supplies with various method. In this study, hinoki cypress (Chamaecyparis obtusa) was used because of its high contents of phytoncide. The leaves of hinoki cypress (C. obtusa), which generated by pruning, were extracted by steam distillation, and then used as humidification water source. Volatile organic compound (VOC) from C. obtusa were characterized by GC-MS (Gas chromatograph-Mass spectrophotometry) in order to evaluate effects and risks of using C. obtusa extracts. Total 86 types and 116 types of VOC were detected from distilled water (DI water) and C. obtusa extracts, respectively. Aromatic compounds (DI water: 13 types, 53%; C. obtusa extracts: 13 types, 38%) and terpenoids (DI water: 16 types, 23%; C. obtusa extracts: 23 types, 33%) were detected more diverse types and higher amount than other compound categories. No additional aromatic compounds were found from C. obtusa extracts, so C. obtusa extracts did not affect on aromatic compounds emission. However, in terpenoids, total amount of emission from C. obtusa extracts increased to 33% from 23% (DI water) and 7 more types of compounds were found from C. obtusa extracts. Especially, from C. obtusa extracts, terpinen-4-ol was emitted 71 times higher than DI water. During the humidification with C. obtusa extracts, emitted terpenoid compounds were well known for higher anti-bacterial, anti-insect, and anti-septic functions, but also these had anti-hypertensive and anti-cancer activities. Therefore, terpenoids from C. obtusa extracts can help to improve public health by using humidifier.

Clean Room Structure, Air Conditioning and Contamination Control Systems in the Semiconductor Fabrication Process (반도체 웨이퍼 제조공정 클린룸 구조, 공기조화 및 오염제어시스템)

  • Choi, Kwang-Min;Lee, Ji-Eun;Cho, Kwi-Young;Kim, Kwan-Sick;Cho, Soo-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.202-210
    • /
    • 2015
  • Objectives: The purpose of this study was to examine clean room(C/R) structure, air conditioning and contamination control systems and to provide basic information for identifying a correlation between the semiconductor work environment and workers' disease. Methods: This study was conducted at 200 mm and 300 mm semiconductor wafer fabrication facilities. The C/R structure and air conditioning method were investigated using basic engineering data from documentation for C/R construction. Furthermore, contamination parameters such as airborne particles, temperature, humidity, acids, ammonia, organic compounds, and vibration in the C/R were based on the International Technology Roadmap for Semiconductors(ITRS). The properties of contamination control systems and the current status of monitoring of various contaminants in the C/R were investigated. Results: 200 mm and 300 mm wafer fabrication facilities were divided into fab(C/R) and sub fab(Plenum), and fab, clean sub fab and facility sub fab, respectively. Fresh air(FA) is supplied in the plenum or clean sub fab by the outdoor air handling unit system which purifies outdoor air. FA supply or contaminated indoor air ventilation rates in the 200 mm and 300 mm wafer fabrication facilities are approximately 10-25%. Furthermore, semiconductor clean rooms strictly controlled airborne particles(${\leq}1,000{\sharp}/ft^3$), temperature($23{\pm}0.5^{\circ}C$), humidity($45{\pm}5%$), air velocity(0.4 m/s), air change(60-80 cycles/hr), vibration(${\leq}1cm/s^2$), and differential pressure(atmospheric pressure$+1.0-2.5mmH_2O$) through air handling and contamination control systems. In addition, acids, alkali and ozone are managed at less than internal criteria by chemical filters. Conclusions: Semiconductor clean rooms can be a pleasant environment for workers as well as semiconductor devices. However, based on the precautionary principle, it may be necessary to continuously improve semiconductor processes and the work environment.