• Title/Summary/Keyword: 오리피스형

Search Result 98, Processing Time 0.019 seconds

Review of Application of VOF-Based NWT on Integrated OWC System (VOF 기반의 수치조파수조를 이용한 OWC 통합시스템 성능연구에 대한 고찰)

  • Liu, Zhen;Jin, Ji-Yuan;Hyun, Beom-Soo;Hong, Key-Yong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.2
    • /
    • pp.111-117
    • /
    • 2012
  • Oscillating water column is the most widely used ocean energy converting systems all over the world. The operating performance is influenced by the efficiencies of the two converting stages in the OWC chamber-turbine integrated system. In order to consider the effects of the turbine, the orifice model are carried out. The VOF based Numerical Wave Tank (NWT) is utilized to simulate the water column oscillation inside the chamber and the results are compared with corresponding experimental data. This paper reviews the state of the art in interaction among wave elevation inside the chamber and air flow rate in the duct, which are considered the turbine effects. Effects of incident wave conditions and several shape parameters on the operating performance of OWC chamber are investigated numerically. The effects of the impulse turbine on the integrated system and interaction among the wave elevation, pressure and air flow velocities variations are investigated.

Geometric Effects on Damping Characteristics of Acoustic Cavity for the Control of Combustion Instabilities (연소불안정 제어를 위한 음향공의 감쇠에 대한 형상 효과)

  • 차정필;고영성;고영성
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.6
    • /
    • pp.59-66
    • /
    • 2006
  • Acoustic cavity as a stabilization device to control high-frequency combustion instabilities in liquid rocket engine is adopted and its damping capacity is verified in atmospheric temperature. First, harmful resonant frequency in a modeling chamber can be damped effectively by the installation of properly-tuned acoustic cavity. Besides, geometric effects of acoustic cavity on damping characteristics are analyzed and compared quantitatively. Satisfactory agreements have been achieved with linear acoustic analysis and experimental approach. Results show that the acoustic cavity of the largest orifice area or the shortest orifice length was the most effective in acoustic damping of the harmful resonant frequency. Finally, it is proved that an optimal design process is indispensable for the effective control of combustion instabilities.

Analysis of Flow Characteristic and Optimum Design for Subminiature Pressure Reducer Under High Pressure (고압 적용용 초소형 감압기 설계를 위한 유동 해석 및 최적 설계)

  • Lee, WonJun;Baek, JongTae;Yun, Rin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.8
    • /
    • pp.497-503
    • /
    • 2017
  • A theoretical study on oxygen flow is fundamental to comprehend the practical production of an oxygen respirator and its stability. In this study, an orifice-type pressure-reducing component was designed for the newly developed oxygen respirator, using the commercial CFD tool, COMSOL Multiphysics, which increases its operational time compared to the existing component. The orifice was optimized by changing the length by 3, 6, and 9 mm within the entire computational domain of the oxygen respirator. Based on an oxygen flow rate of 0.028 kg/s, the oxygen respirator equipped with the newly developed orifice satisfied the flow rate within 33% for a respirator inlet pressure of 300 bar, and within 32.7% for 50, 75, and 100 bar. In terms of component manufacturing, the orifice length was selected as 3 mm, which removes additional changes to the existing component.

Operation and Result Analysis of Hydraulic Vehicle Holding Device (발사체 지상고정장치 유압시스템 작동 시험 및 결과 분석)

  • Kim, Dae Rae;Yang, Seong Pil;Lee, Jae Jun;Song, Oh-Seob;Lee, Young-Shin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.1
    • /
    • pp.80-88
    • /
    • 2018
  • The function of a vehicle holding device (VHD) is to securely hold a launch vehicle on the launch pad and release the launch vehicle at maximum thrust after engine ignition to allow lift-off of the launch vehicle. During the release of the launch vehicle, to prevent the Ka doing a doing a doing mode, which is the vertical oscillation of the entire liquid propellant, the release of the launch vehicle should be gradual. In this study, for the gradual release of a launch vehicle, a hydraulic system comprising an accumulator and pyro valve to operate a hydraulic cylinder and control the speed of the cylinder with an orifice is introduced. Through a test, the influence of design variables on the cylinder speed is analyzed. Based on this, the design values of the hydraulic cylinder are determined. Through this study, the engineering basis for developing a VHD releasing a launch vehicle at maximum thrust is provided.

Ground Ejection Tests to verify the Safe Separation of an Aircraft Mounted Store (항공기 장착 무장의 투하 안정성 검증을 위한 지상무장분리시험)

  • Lee, Jong-Hong;Choi, Seok-Min;Lee, Min-Hyoung;Lee, Chul;Jung, Jae-Won
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.2
    • /
    • pp.70-75
    • /
    • 2018
  • The mounted store on an aircraft shall be subjected to an ground separation test to verify that a safe separation has been made before it is actually installed to the aircraft. In this study, ground ejection test was conducted with dummy missile to verify the stability of the drop on the land. Bomb rack unit essential to testing ground ejection test, operate at high pressure and produce a significant ejection force to push the missile away from any large orifice. Bomb rack unit modified their bombe pressure and orifice diameter to photograph the drop movement of dummy missile with high-speed camera and to analyze their drop displacement and speed. It is considered useful to provide the initial data for the ejection force analysis on aircraft with actual flight and to carry out the ground separation tests of aircraft with future developments.

A Study on the Air Vent Valve of the Hydraulic Servo Actuator for Steam Control of Power Plants (발전소의 스팀제어용 유압서보 액추에이터의 공기배출 밸브에 관한 연구)

  • Lee, Yong Bum;Lee, Jong Jik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.6
    • /
    • pp.397-402
    • /
    • 2016
  • To produce adequate electricity in nuclear and thermal power plants, an optimal amount of steam should be supplied to a generator connected to high- and low-pressure steam turbines. A turbine output control device, which is a special steam valve employed to supply or interrupt the steam to the turbine, is operated using a hydraulic servo actuator. In power plants, the performance of servo actuators is degraded by the air generated from the hydraulic system, or causes frequent failures owing to an increase in the wear of the seal. This is due to the seal being burnt as generated heat using the produced compressed air. Some power plants have exhausted air using a fixed orifice, and thus they encounter power loss due to mass flow exhaust. Failures are generated in hydraulic pumps, electric motors, and valves, which are frequently operated. In this study, we perform modeling and analysis of the load-sensing air-exhaust valves, which can be passed through very fine flow under normal use conditions, and exhaust mass flow air at the beginning stage as with existing fixed orifices. Then, we propose a method to prevent failures due to the compressed air, and to ensure the control accuracy of hydraulic servo actuators.

A Study on the Experimental Dynamic Identification of Cylindrical Oil Dampers in the Wide Frequency Range (넓은 주파수 범위에서의 실린더형 유체 댐퍼에 대한 실험적 동특성 규명 연구)

  • Moon, S.J.;Kim, H.S.;Chung, T.Y.;Lee, D.H.;Hwang, J.Y.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.6
    • /
    • pp.528-536
    • /
    • 2010
  • System identification for cylindrical oil dampers is carried out based on a series of dynamic experimental tests and theoretical approach for the analysis of the experimental data. Experimental tests are conducted using a specific hydraulic actuator in the wide frequency range from 10 Hz to 90 Hz. From this study, it is confirmed that control force of the damper is composed of inertia, damping and restoring components. In general, both restoring and damping components are significant and comparable. However, the portion of the inertia components becomes more significant than to be negligible in the high frequency range.

Development of Water Wheel Type Oil Skimmer (수차형 유회수기의 개발)

  • 노준혁;박안진;강상훈;이영식;김종현;윤범상
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.123-128
    • /
    • 2000
  • The ocean is now increasingly suffering from pollution mainly caused by oil spill accidents roil increasing marine transportation. It cause not only the deterioration of ocean resources but also critical damage on the ocean ecosystem. Present study is an experimental one for the development of the oil skimmer which can collect spilled-oil actively and effectively from the sea surface. As an effort of achieving it, a new type of water wheel attached nil skimmer was devised, based upon the concept of orifice. The shapes of the water wheel, blades and oil storing tank are found to be very important factors on the oil skimming performance through systematic experimental analysis. Real oil recovery test was also carried out in square tank using the oil skimmer with their optimal shapes. Quite satisfactory result are obtained from the test which showed 99% and 98% recovery rates for light oil and heavy oil in still water condition, respectively.

  • PDF

A numerical study on the optimum size for the orifice located on the steam generator cassette of integral reactor (일체형원자로 증기발생기 카세트 하단에 설치된 오리피스의 최적설계 연구)

  • Kang Hyung Seok;Yoon Juhyeon;Kim Hwan Yeol;Cho Bong Hyun;Lee Doo Jeong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.05a
    • /
    • pp.75-81
    • /
    • 1998
  • A new advanced integral reactor of 330 MWt capacity named SMART(System-integrated Modular Advanced ReacTor) is currently under development at KAERI(Korea Atomic Energy Research Institute). One of the major design features of the integral reactor is locating the steam generators(SG) inside reactor vessel and eliminating the possibility of LB LOCA(large Break Loss of Coolant Accident). Orifices are fitted at the low part of steam generator cassette to stabilize and balance coolant flow distribution in the MCP (Main Circulation Pump) pressure header. A sensitivity analysis is conducted to determine the optimum orifice size using computer code 'CFX'.

  • PDF

An experimental study on the application of water mist system in cabin on a passenger ship (여객선 선실 적용을 위한 미분무수 소화설비의 실험적 연구)

  • Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae;Lee, Yu-Whan;Do, Kyu-Hyung;Kim, Chang
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.385-388
    • /
    • 2012
  • 여객선의 선실(cabin)에 적용하기 위한 미분무 소화설비(water mist system)가 개발되었다. 미분무헤드는 8개의 오리피스로 구성된 조기반응 응답특성을 가진 폐쇄형으로, 사용압력과 유량계수(Flow constant)는 각각 1.4MPa과 13.1이다. IMO(국제 해사기구)의 거주구역 소화시스템 성능기준인 Resolution MSC.265(2008)는 선실 적용을 위해 4개의 화재시나리오에 대한 성능판정 기준을 제시하고 있는데, 본 연구에서는 4개의 화재시나리오를 적용한 실물화재실험을 수행하였으며, 이 기준에서 제시한 성능 판정기준을 만족하는 결과를 얻었다. 2011년 국가화재안전 기준 NFSC 104A 기준 정립으로 국내에 도입되기 시작한 미분무소화설비가 적용분야를 넓혀 가는데 도움이 되길 기대해 본다.

  • PDF