• Title/Summary/Keyword: 오류발생

Search Result 2,562, Processing Time 0.029 seconds

Survey on the distribution of ancient tombs using LiDAR measurement method (라이다(LiDAR) 측량기법을 활용한 고분분포현황 조사)

  • SIM Hyeoncheol
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.4
    • /
    • pp.54-70
    • /
    • 2023
  • Surveys and studies on cultural assets using LiDAR measurement are already active overseas. Recently, awareness of the advantages and availability of LiDAR measurement has increased in Korea, and cases of using it for surveys of cultural assets are gradually increasing. However, it is usually restricted to surveys of mountain fortresses and is not actively used for surveys of ancient tombs yet. Therefore, this study intends to emphasize the need to secure fundamental data from LiDAR measurement for the era from the Three Kingdoms to Unified Silla in which recovery, maintenance, etc., in addition to the actual surveys, are unfulfilled due to the sites being mainly distributed in mountainous areas. For this, LiDAR measurement was executed for the area of Jangsan Ancient Tombs and Chunghyo-dong Ancient Tombs in Seoak-dong, Gyeongju, to review the distribution and geographical conditions of ancient tombs. As a result, in the Jangsan Ancient Tombs, in which a precision archaeological (measurement) survey was already executed, detailed geographic information and distribution conditions could be additionally identified, which could not be known only with the layout indicated by the topographic map of the existing report. Also, in the Chunghyo-dong Ancient Tombs, in which an additional survey was not conducted after 10 tombs were found during the Japanese colonial period, the location of the ancient tombs initially excavated was accurately identified, and the status and additional information was acquired, such as on the conditions of ancient tombs not surveyed. Such information may also be used as fundamental data for the preservation and maintenance of future ancient tombs in addition to the survey and study of the ancient tombs themselves. LiDAR measurement is most effective for identifying the condition of ancient tombs in mountainous areas where observation is difficult or access is limited due to the forest zone. It may be executed before on-site surveys, such as archaeological surveys, to secure data with high availability as prior surveys or pre-surveys. Therefore, it is necessary to secure fundamental data from LiDAR measurement in future surveys of ancient tombs and to establish a survey and maintenance/utilization plan based on this. To establish survey/study and preservation/maintenance measures for ancient tombs located in mountainous areas, a precision archaeological survey is currently executed to draw up a distribution chart of ancient tombs. If LiDAR measurement data is secured before this and used, a more effective and accurate distribution chart can be drawn up, and the actual conditions can be identified. Also, most omissions or errors in information can be prevented in on-site surveys of large regions. Therefore, it is necessary to accumulate fundamental data by actively using LiDAR measurement in future surveys of ancient tombs.

Research on Making a Disaster Situation Management Intelligent Based on User Demand (사용자 수요 기반의 재난 상황관리 지능화에 관한 연구)

  • Seon-Hwa Choi;Jong-Yeong Son;Mi-Song Kim;Heewon Yoon;Shin-Hye Ryu;Sang Hoon Yoon
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_2
    • /
    • pp.811-825
    • /
    • 2023
  • In accordance with the government's stance of actively promoting intelligent administrative service policies through data utilization, in the disaster and safety management field, it also is proceeding with disaster and safety management policies utilizing data and constructing systems for responding efficiently to new and complex disasters and establishing scientific and systematic safety policies. However, it is difficult to quickly and accurately grasp the on-site situation in the event of a disaster, and there are still limitations in providing information necessary for situation judgment and response only by displaying vast data. This paper focuses on deriving specific needs to make disaster situation management work more intelligent and efficient by utilizing intelligent information technology. Through individual interviews with workers at the Central Disaster and Safety Status Control Center, we investigated the scope of disaster situation management work and the main functions and usability of the geographic information system (GIS)-based integrated situation management system by practitioners in this process. In addition, the data built in the system was reclassified according to purpose and characteristics to check the status of data in the GIS-based integrated situation management system. To derive needed to make disaster situation management more intelligent and efficient by utilizing intelligent information technology, 3 strategies were established to quickly and accurately identify on-site situations, make data-based situation judgments, and support efficient situation management tasks, and implementation tasks were defined and task priorities were determined based on the importance of implementation tasks through analytic hierarchy process (AHP) analysis. As a result, 24 implementation tasks were derived, and to make situation management efficient, it is analyzed that the use of intelligent information technology is necessary for collecting, analyzing, and managing video and sensor data and tasks that can take a lot of time of be prone to errors when performed by humans, that is, collecting situation-related data and reporting tasks. We have a conclusion that among situation management intelligence strategies, we can perform to develop technologies for strategies being high important score, that is, quickly and accurately identifying on-site situations and efficient situation management work support.

The Correction Effect of Motion Artifacts in PET/CT Image using System (PET/CT 검사 시 움직임 보정 기법의 유용성 평가)

  • Yeong-Hak Jo;Se-Jong Yoo;Seok-Hwan Bae;Jong-Ryul Seon;Seong-Ho Kim;Won-Jeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2024
  • In this study, an AI-based algorithm was developed to prevent image quality deterioration and reading errors due to patient movement in PET/CT examinations that use radioisotopes in medical institutions to test cancer and other diseases. Using the Mothion Free software developed using, we checked the degree of correction of movement due to breathing, evaluated its usefulness, and conducted a study for clinical application. The experimental method was to use an RPM Phantom to inject the radioisotope 18F-FDG into a vacuum vial and a sphere of a NEMA IEC body Phantom of different sizes, and to produce images by directing the movement of the radioisotope into a moving lesion during respiration. The vacuum vial had different degrees of movement at different positions, and the spheres of the NEMA IEC body Phantom of different sizes produced different sizes of lesions. Through the acquired images, the lesion volume, maximum SUV, and average SUV were each measured to quantitatively evaluate the degree of motion correction by Motion Free. The average SUV of vacuum vial A, with a large degree of movement, was reduced by 23.36 %, and the error rate of vacuum vial B, with a small degree of movement, was reduced by 29.3 %. The average SUV error rate at the sphere 37mm and 22mm of the NEMA IEC body Phantom was reduced by 29.3 % and 26.51 %, respectively. The average error rate of the four measurements from which the error rate was calculated decreased by 30.03 %, indicating a more accurate average SUV value. In this study, only two-dimensional movements could be produced, so in order to obtain more accurate data, a Phantom that can embody the actual breathing movement of the human body was used, and if the diversity of the range of movement was configured, a more accurate evaluation of usability could be made.

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF

Korean Sentence Generation Using Phoneme-Level LSTM Language Model (한국어 음소 단위 LSTM 언어모델을 이용한 문장 생성)

  • Ahn, SungMahn;Chung, Yeojin;Lee, Jaejoon;Yang, Jiheon
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.2
    • /
    • pp.71-88
    • /
    • 2017
  • Language models were originally developed for speech recognition and language processing. Using a set of example sentences, a language model predicts the next word or character based on sequential input data. N-gram models have been widely used but this model cannot model the correlation between the input units efficiently since it is a probabilistic model which are based on the frequency of each unit in the training set. Recently, as the deep learning algorithm has been developed, a recurrent neural network (RNN) model and a long short-term memory (LSTM) model have been widely used for the neural language model (Ahn, 2016; Kim et al., 2016; Lee et al., 2016). These models can reflect dependency between the objects that are entered sequentially into the model (Gers and Schmidhuber, 2001; Mikolov et al., 2010; Sundermeyer et al., 2012). In order to learning the neural language model, texts need to be decomposed into words or morphemes. Since, however, a training set of sentences includes a huge number of words or morphemes in general, the size of dictionary is very large and so it increases model complexity. In addition, word-level or morpheme-level models are able to generate vocabularies only which are contained in the training set. Furthermore, with highly morphological languages such as Turkish, Hungarian, Russian, Finnish or Korean, morpheme analyzers have more chance to cause errors in decomposition process (Lankinen et al., 2016). Therefore, this paper proposes a phoneme-level language model for Korean language based on LSTM models. A phoneme such as a vowel or a consonant is the smallest unit that comprises Korean texts. We construct the language model using three or four LSTM layers. Each model was trained using Stochastic Gradient Algorithm and more advanced optimization algorithms such as Adagrad, RMSprop, Adadelta, Adam, Adamax, and Nadam. Simulation study was done with Old Testament texts using a deep learning package Keras based the Theano. After pre-processing the texts, the dataset included 74 of unique characters including vowels, consonants, and punctuation marks. Then we constructed an input vector with 20 consecutive characters and an output with a following 21st character. Finally, total 1,023,411 sets of input-output vectors were included in the dataset and we divided them into training, validation, testsets with proportion 70:15:15. All the simulation were conducted on a system equipped with an Intel Xeon CPU (16 cores) and a NVIDIA GeForce GTX 1080 GPU. We compared the loss function evaluated for the validation set, the perplexity evaluated for the test set, and the time to be taken for training each model. As a result, all the optimization algorithms but the stochastic gradient algorithm showed similar validation loss and perplexity, which are clearly superior to those of the stochastic gradient algorithm. The stochastic gradient algorithm took the longest time to be trained for both 3- and 4-LSTM models. On average, the 4-LSTM layer model took 69% longer training time than the 3-LSTM layer model. However, the validation loss and perplexity were not improved significantly or became even worse for specific conditions. On the other hand, when comparing the automatically generated sentences, the 4-LSTM layer model tended to generate the sentences which are closer to the natural language than the 3-LSTM model. Although there were slight differences in the completeness of the generated sentences between the models, the sentence generation performance was quite satisfactory in any simulation conditions: they generated only legitimate Korean letters and the use of postposition and the conjugation of verbs were almost perfect in the sense of grammar. The results of this study are expected to be widely used for the processing of Korean language in the field of language processing and speech recognition, which are the basis of artificial intelligence systems.

Steel Plate Faults Diagnosis with S-MTS (S-MTS를 이용한 강판의 표면 결함 진단)

  • Kim, Joon-Young;Cha, Jae-Min;Shin, Junguk;Yeom, Choongsub
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.1
    • /
    • pp.47-67
    • /
    • 2017
  • Steel plate faults is one of important factors to affect the quality and price of the steel plates. So far many steelmakers generally have used visual inspection method that could be based on an inspector's intuition or experience. Specifically, the inspector checks the steel plate faults by looking the surface of the steel plates. However, the accuracy of this method is critically low that it can cause errors above 30% in judgment. Therefore, accurate steel plate faults diagnosis system has been continuously required in the industry. In order to meet the needs, this study proposed a new steel plate faults diagnosis system using Simultaneous MTS (S-MTS), which is an advanced Mahalanobis Taguchi System (MTS) algorithm, to classify various surface defects of the steel plates. MTS has generally been used to solve binary classification problems in various fields, but MTS was not used for multiclass classification due to its low accuracy. The reason is that only one mahalanobis space is established in the MTS. In contrast, S-MTS is suitable for multi-class classification. That is, S-MTS establishes individual mahalanobis space for each class. 'Simultaneous' implies comparing mahalanobis distances at the same time. The proposed steel plate faults diagnosis system was developed in four main stages. In the first stage, after various reference groups and related variables are defined, data of the steel plate faults is collected and used to establish the individual mahalanobis space per the reference groups and construct the full measurement scale. In the second stage, the mahalanobis distances of test groups is calculated based on the established mahalanobis spaces of the reference groups. Then, appropriateness of the spaces is verified by examining the separability of the mahalanobis diatances. In the third stage, orthogonal arrays and Signal-to-Noise (SN) ratio of dynamic type are applied for variable optimization. Also, Overall SN ratio gain is derived from the SN ratio and SN ratio gain. If the derived overall SN ratio gain is negative, it means that the variable should be removed. However, the variable with the positive gain may be considered as worth keeping. Finally, in the fourth stage, the measurement scale that is composed of selected useful variables is reconstructed. Next, an experimental test should be implemented to verify the ability of multi-class classification and thus the accuracy of the classification is acquired. If the accuracy is acceptable, this diagnosis system can be used for future applications. Also, this study compared the accuracy of the proposed steel plate faults diagnosis system with that of other popular classification algorithms including Decision Tree, Multi Perception Neural Network (MLPNN), Logistic Regression (LR), Support Vector Machine (SVM), Tree Bagger Random Forest, Grid Search (GS), Genetic Algorithm (GA) and Particle Swarm Optimization (PSO). The steel plates faults dataset used in the study is taken from the University of California at Irvine (UCI) machine learning repository. As a result, the proposed steel plate faults diagnosis system based on S-MTS shows 90.79% of classification accuracy. The accuracy of the proposed diagnosis system is 6-27% higher than MLPNN, LR, GS, GA and PSO. Based on the fact that the accuracy of commercial systems is only about 75-80%, it means that the proposed system has enough classification performance to be applied in the industry. In addition, the proposed system can reduce the number of measurement sensors that are installed in the fields because of variable optimization process. These results show that the proposed system not only can have a good ability on the steel plate faults diagnosis but also reduce operation and maintenance cost. For our future work, it will be applied in the fields to validate actual effectiveness of the proposed system and plan to improve the accuracy based on the results.

Intestinal Atresia - A Survey by the Korean Association of Pediatric Surgeons - (선천성 장폐쇄증 - 대한소아외과학회 정회원을 대상으로 한 전국조사 -)

  • Kim, I.K.;Kim, S.Y.;Kim, S.K.;Kim, W.K.;Kim, J.E.;Kim, J.C.;Kim, H.H.;Park, K.W.;Park, Y.S.;Park, W.H.;Song, Y.T;Yang, J.W.;Oh, S.M.;Yoo, S.Y.;Lee, D.S.;Lee, M.D.;Lee, S.K.;Lee, S.C.;Chang, S.I.
    • Advances in pediatric surgery
    • /
    • v.5 no.1
    • /
    • pp.75-81
    • /
    • 1999
  • A survey on the intestinal atresias was made among 34 members of Korean Association of Pediatric Surgeons. The response rate was 82.4 %. Two hundred and fifteen patients from the January 1, 1994 to December 31, 1996 were analyzed. The lesions were 73 cases of duodenum(DA), 72 cases of jejunum(JA), 71 cases ileum(IA) and 2 cases cecum and sigmoid colon respectively. There were 2 cases of combined anomalies (DA + JA + IA and DA + JA). Male to female ratio was 1:1 in DA, and 1.8:1 in JA. Seventy four cases(34.3 %) were premature babies(DA 35.2 %, JA:48.6 %, IA:19.2 %), and 62 cases(28.7 %) had low birth weight (DA:39.4 %, JA 33.0 %, IA:13.7 %). Antenatal diagnosis was made in 92 cases(43.6 %). However 22 cases (23.9 %) of them were transferred to pediatric surgeon after delivery. Maternal polyhydramnios was observed in 63 cases(28.9 %). Seventy· five cases(34.4 %) were taken only simple abdominal film for diagnostic studies. The associated malformations were observed in 54 aresia and were observed more frequently in DA(35 cases, 47.9 %). Meconium peritonitis due to intrauterine bowel perforation was more frequently associated with IA compared to DA and JA. The overall mortality rate was 30 %. (Abbreuations: $P_{T}$;p-value in total, $P_{DJ,DI,JI}$;p value between two groups among duodenal, jejunal and ileal groups).

  • PDF

Multivessel Coronary Revascularization with Composite LITA-RA Y Graft (좌내흉동맥-요골동맥 복합이식편을 이용한 다중혈관 관상동맥우회술)

  • Lee Sub;Ko Mgo-Sung;Park Ki-Sung;Ryu Jae-Kean;Jang Jae-Suk;Kwon Oh-Choon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.359-365
    • /
    • 2006
  • Background: Arterial grafts have been used to achieve better long-term results for coronary revascularization. Bilateral internal thoracic artery (ITA) grafts have a better results, but it may be not used in some situations such as diabetes and chronic obstructive pulmonary disease (COPD). We evaluated the clinical and angiographic results of composite left internal thoracic artery-radial artery (LITA-RA) Y graft. Material and Method: Between April 2002 and September 2004, 119 patients were enrolled in composite Y graft for coronary bypass surgery. The mean age was $62.6{\pm}8.8$ years old and female was 34.5%. Preoperative cardiac risk factors were as follows: hypertension 43.7%, diabetes 33.6%, smoker 41.2%, and hyperlipidemia 22.7%, There were emergency operation (14), cardiogenic shock (6), left ventricle ejection fraction (LVEF) less than 40% (17), and 17 cases of left main disease. Coronary angiography was done in 35 patients before the hospital discharge. Result: The number of distal anastomoses was $3.1{\pm}0.91$ and three patients (2.52%) died during hospital stay. The off-pump coronary artery bypass (OPCAB) was applied to 79 patients (66.4%). The LITA was anastomosed to left anterior descending system except three cases which was to lateral wall. The radial Y grafts were anastomosed to diagonal branches (4), ramus intermedius (21), obtuse marginal branches (109), posterolateral branches (12), and posterior descending coronary artery (8). Postoperative coronary angiography in 35 patients showed excellent patency rates (LITA 100%, and RA 88.5%; 3 RA grafts which anastomosed to coronary arteries <70% stenosed showed string sign with competitive flow). Conclusion: The LITA-RA Y composite graft provided good early clinical and angiographic results in multivessel coronary revascularization. But it should be cautiously used in selected patients.

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.

Analysis of Respiratory Motional Effect on the Cone-beam CT Image (Cone-beam CT 영상 획득 시 호흡에 의한 영향 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mi-Sun
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.81-86
    • /
    • 2007
  • The cone-beam CT (CBCT) which is acquired using on-board imager (OBI) attached to a linear accelerator is widely used for the image guided radiation therapy. In this study, the effect of respiratory motion on the quality of CBCT image was evaluated. A phantom system was constructed in order to simulate respiratory motion. One part of the system is composed of a moving plate and a motor driving component which can control the motional cycle and motional range. The other part is solid water phantom containing a small cubic phantom ($2{\times}2{\times}2cm^3$) surrounded by air which simulate a small tumor volume in the lung air cavity CBCT images of the phantom were acquired in 20 different cases and compared with the image in the static status. The 20 different cases are constituted with 4 different motional ranges (0.7 cm, 1.6 cm, 2.4 cm, 3.1 cm) and 5 different motional cycles (2, 3, 4, 5, 6 sec). The difference of CT number in the coronal image was evaluated as a deformation degree of image quality. The relative average pixel intensity values as a compared CT number of static CBCT image were 71.07% at 0.7 cm motional range, 48.88% at 1.6 cm motional range, 30.60% at 2.4 cm motional range, 17.38% at 3.1 cm motional range The tumor phantom sizes which were defined as the length with different CT number compared with air were increased as the increase of motional range (2.1 cm: no motion, 2.66 cm: 0.7 cm motion, 3.06 cm: 1.6 cm motion, 3.62 cm: 2.4 cm motion, 4.04 cm: 3.1 cm motion). This study shows that respiratory motion in the region of inhomogeneous structures can degrade the image quality of CBCT and it must be considered in the process of setup error correction using CBCT images.

  • PDF