• Title/Summary/Keyword: 예측적

Search Result 24,118, Processing Time 0.056 seconds

A Study on the Behaviour of Prebored and Precast Steel Pipe Piles from Full-Scale Field Tests and Class-A and C1 Type Numerical Analyses (현장시험과 Class-A 및 C1 type 수치해석을 통한 강관매입말뚝의 거동에 대한 연구)

  • Kim, Sung-Hee;Jung, Gyoung-Ja;Jeong, Sang-Seom;Jeon, Young-Jin;Kim, Jeong-Sub;Lee, Cheol-Ju
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.7
    • /
    • pp.37-47
    • /
    • 2017
  • In this study, a series of full-scale field tests on prebored and precast steel pipe piles and the corresponding numerical analysis have been conducted in order to study the characteristics of pile load-settlement relations and shear stress transfer at the pile-soil interface. Dynamic pile load tests (EOID and restrike) have been performed on the piles and the estimated design pile loads from EOID and restrike tests were analysed. Class-A type numerical analyses conducted prior to the pile loading tests were 56~105%, 65~121% and 38~142% respectively of those obtained from static load tests. In addition, design loads estimated from the restrike tests indicate increases of 12~60% compared to those estimated in the EOID tests. The EOID tests show large end bearing capacity while the restrike tests demonstrate increased skin friction. When impact energy is insufficient during the restrike tests, the end bearing capacity may be underestimated. It has been found that total pile capacity would be reasonably estimated if skin friction from the restrike tests and end bearing capacity from the EOID are combined. The load-settlement relation measured from the static pile load tests and estimated from the numerical modelling is in general agreement until yielding occurs, after which results from the numerical analyses substantially deviated away from those obtained from the static load tests. The measured pile behaviour from the static load tests shows somewhat similar behaviour of perfectly-elastic plastic materials after yielding with a small increase in the pile load, while the numerical analyses demonstrates a gradual increase in the pile load associated with strain hardening approaching ultimate pile load. It has been discussed that the load-settlement relation mainly depends upon the stiffness of the ground, whilst the shear transfer mechanism depends on shear strength parameters.

A Comparison Study between Batch and Continuous Process Simulation for the Separation of Carbon-13 Isotope by Cryogenic Distillation (Methane으로부터 13C 동위원소 분리를 위한 회분식 및 연속식 극저온 증류공정모사 비교 연구)

  • Kim, Jong Hwan;Lee, Doug Hyung;Lee, Euy Soo;Park, Sang Jin
    • Korean Chemical Engineering Research
    • /
    • v.45 no.1
    • /
    • pp.57-66
    • /
    • 2007
  • Natural gases generally consist of mainly $^{12}C$ and about 1.1% of $^{13}C$. It is well known that a stable carbon isotope, $^{13}C$, has been widely used for the applications of medical, pharmaceutical, and agricultural tracers. As a result, the development of the separation and concentrating technology of $^{13}C$ can cause of high value-added products and the possibility of the generation of new carbon materials, In general, there are two kinds of approaches to obtain a stable $^{13}C$ isotope by the separation of cryogenic distillation. One is to obtain a concentrated $^{13}CH_4$ isotope from natural gas. Another approach is to get concentrated $^{13}CO$ by distillation followed by a chemical reaction of $CH_4$ and $H_2O$. In this study, rigorous process simulations of the cryogenic distillation have been performed and analyzed for the concentrated separation of $^{13}C$ isotopes from LNG and NG by using commercial process simulator. Due to the very small differences of relative volatilities and separabilities of $^{12}C$ and $^{13}C$, the process design and operation of effective separation and concentration of $^{13}C$ need special strategies and feasibility studies. Utilization of vapor pressure data to acentric factor in SRK equation of state and optimized process conditions have been able to predict for the effective of the separation yield and concentration of $^{13}C$ for the cryogenic distillation. The various operation strategies for both batch and continuous cryogenic distillation are also studied and suggested for the basic design of the process. Development of this study can provide a tool for the effective design and operation of the cryogenic separation of $^{13}C$.

Influencing Factors on Cleaning Ability in the Formulated Hydrocarbon-based Cleaning Agents (탄화수소계 배합세정제에서의 세정성 영향인자 연구)

  • Jung, Young-Woo;Lee, Ho-Yeoul;Bae, Jae-Heum
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.143-150
    • /
    • 2007
  • The objective of this study is to develop hydrocarbon-based cleaning agents by blending paraffins, glycol ethers and siloxanes in oder to effectively clean contaminants such as flux, solder and grease. And the effect of cleaning ability by wetting index, aniline points and solubility parameter of the formulated hydrocarbon-based cleaning agents were studied in this work. The formulated hydrocarbon-based cleaning agents were prepared on the base of physical properties of their individual components. Wetting indexes and aniline points of their were measured through experiments and solubility parameters of their were calculated based on the Hansen's equation. In this study, evaluation of cleaning ability by cleaning agents were carried out using contaminants such as flux, solder, and grease. The experimental results showed that the cleaning ability of the formulated cleaning agents was excellent in cleaning contaminants such as flux, solder and grease and that the influencing parameters on their cleaning efficiency were found to be different according to contaminant types. MC($20.3MPa^{1/2}$), DF-1 ($24.2MPa^{1/2}$) and DF-2($21.5MPa^{1/2}$) with similar solubility parameter as flux ($21.3MPa^{1/2}$) showed 100% cleaning efficiency within 3 minutes in flux cleaning. And CFC-113, MC and 1,1,1-TCE with low aniline point less than $-20^{\circ}C$ showed excellent cleaning efficiency in solder cleaning. DG-1($16.2\;MPa^{1/2}$) and DG-2($15.5\;MPa^{1/2}$) with similar solubility parameter as grease($15.0{\sim}17.0\;MPa^{1/2}$) showed relatively low cleaning efficiency of grease, but CFC-113 and MC with high wetting index and low aniline point showed good cleaning efficiency in grease cleaning. As a result of this study, the hydrocarbon-based cleaning agents alternative to regulated cleaning agents such as CFC-113, 1,1,1-TCE and MC were able to be developed through properly blending paraffins, glycol ethers and siloxanes for cleaning flux, solder and grease. And it can be shown that various influencing parameters of cleaning efficiency such as wetting index, aniline point, solubility parameter and etc. of the non-aqueous cleaning agent should be reviewed for prediction of their cleaning ability and can be applied to formulation of cleaning agents.

  • PDF

Evaluation and Prediction of Failure Hazard Area by the Characteristics of Forest Watershed (산림유역 특성에 의한 붕괴 위험지역의 평가 및 예지)

  • Jeong, Won-Ok;Ma, Ho-Seop
    • Korean Journal of Environment and Ecology
    • /
    • v.20 no.4
    • /
    • pp.415-424
    • /
    • 2006
  • This study was carried out to analyze the characteristics of forest watershed factors by using the quantification theory(I) for evaluation and prediction of the failure hazard area. Present $sediment(m^3/yr/ha)$ of erosion control dams were investigated in 95 sites of erosion control dam constructed during 1986 to 1999 in Gyeongnam province. The results obtained from this study were summarized as follows; General condition of class I(Very hazard area) were as follow; Igneous rock in parent rock, coniferous in forest type, below 20year in stand age, below 30cm in soil depth, SCL in soil texture, $31{\sim}40%$ in gravel contents, $S{\sim}E$ in aspect, $2,501{\sim}3,600m$ in length of main stream, $26{\sim}30$ in number of total streams, $6,601{\sim}10,000m$ in length of total streams, over 3 in stream order, over 16 in number of first streams order and over $31^{\circ}$ of slope gradient. General condition of class IIl(hazard area) were as follow; Metamorphic rock in parent rock, hardwood in forest type, over $21{\sim}24year$ in stand age, $31{\sim}40cm$ in soil depth, SiCL or SCL in soil texture, $11{\sim}20%$ in gravel contents, $S{\sim}W$ in aspect, $1,501{\sim}2,600m$ in length of main stream, $6{\sim}10$ in number of total streams, $3,501{\sim}5,500m$ in length of total streams, 2 in stream order, $6{\sim}10$ in number of first streams order and over $31^{\circ}$ of slope gradient. General condition of class III(Un hazard area) were as follow; Sedimentary rock in parent rock, mixed in forest type, over 25year in stand age, $41{\sim}50cm$ in soil depth, SiCL in soil texture, below 10% in gravel contents, $N{\sim}W$ in aspect, below 500m in length of main stream, below 5 in number of total streams, below 1,000m in length of total treams, below 1 in stream order, below 2 in number of first streams order and below $25^{\circ}$ of slope gradient. The prediction method of suitable for failure hazard area divided into class I, II, and III for the convenience of use. The score of class I evaluated as a very hazard area was over 4.8052. A score of class II was 4.8051 to 2.5602, it was evaluated as a hazard area, and class III was below 2.5601, it was evaluated as a un hazard area.

A Study of Optimized MRI Parameters for Polymer Gel Dosimetry (중합체 겔 선량측정법을 위한 최적의 자기공명영상 변수에 관한 연구)

  • Cho, Sam-Ju;Chung, Young-Lip;Lee, Sang-Hoon;Huh, Hyun-Do;Choi, Jin-Ho;Park, Sung-Ill;Shim, Su-Jung;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.71-80
    • /
    • 2012
  • In order to verify exact dose distributions in the state-of-the-art radiation techniques, a newly designed three-dimensional dosimeter and technique has been took strongly into consideration. The main purpose of our study is to verify the optimized parameters of polymer gel as a real volumetric dosimeter in terms of the various study of MRI. We prepared a gel dosimeter by combing 8% of gelatin, 8% of MAA, and 10 mM of THPC. We used a Co-60 gamma-ray teletherapy unit and delivered doses of 0, 2, 4, 6, 8, 10, 12, and 14 Gy to each polymer gel with a solid phantom. We used a fast spin-echo pulse to acquire the characterized T2 time of MRI. The signal noise ratio (SNR) of the head & neck coil was a relatively lower sensitivity than the body coil; therefore the dose uncertainty of head & neck coil would be lower than body coil's. But the dose uncertainty and resolution of the head & neck coil were superior to the body coil in this study. The TR time between 1,500 ms and 2,000 ms showed no significant difference in the dose resolution, but TR of 1,500 ms showed less dose uncertainty. For the slice thickness of 2.5 mm, less dose uncertainty of TE times was at 4 Gy, as well, it was the lowest result over 4 Gy at TE of 12 ms. The dose uncertainty was not critical up to 6 Gy, but the best dose resolution was obtained at 20 ms up to 8 Gy. The dose resolution shows the lowest value was over 20 ms and was an excellent result in the number of excitation (NEX) of three. The NEX of two was the highest dose resolution. We concluded that the better result of slice thickness versus NEX was related to the NEX increment and thin slice thickness.

Development and Utility Evaluation of Portable Respiration Training Device for Image-guided Stereotactic Body Radiation Therapy (SBRT) (영상유도 체부정위방사선 치료시 호흡동조를 위한 휴대형 호흡연습장치의 개발 및 유용성 평가)

  • Hwang, Seon Bung;Park, Mun Kyu;Park, Seung Woo;Cho, Yu Ra;Lee, Dong Han;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.264-270
    • /
    • 2014
  • This study developed a portable respiratory training device to improve breathing stability, which is an important element in using the CyberKnife Synchrony respiratory tracking device, one of the typical Stereotactic Radiation Therapy (SRT) devices. It produced an interface for users to be able to select one of two displays, a graph type and a bar type, supported an auditory system that helps them expect next respiration by improving a sense of rhythm of their respiratory period, and provided comfortable respiratory inducement. By targeting 5 applicants and applying individual respiratory period detected through a self-developed program, it acquired signal data of 'guide respiration' that induces breathing through signal data gained from 'free respiration' and an auditory system, and evaluated the usability by comparing deviation average values of respiratory period and respiratory amplitude. It could be identified that respiratory period decreased $55.74{\pm}0.14%$ compared to free respiration, and respiratory amplitude decreased $28.12{\pm}0.10%$ compared to free respiration, which confirmed the consistency and stability of respiratory. SBRT, developed based on these results, using the portable respiratory training device, for liver cancer or lung cancer, is evaluated to be able to help reduce delayed treatment time due to respiratory instability and improve treatment accuracy, and if it could be applied to developing respiratory training applications targeting an android-based portable device in the future, even use convenience and economic efficiency are expected.

Endogenous Phenoloxidase Purified from an Earthworm, Lumbricus rubellus (붉은 지렁이(Lumbricus rubellus) 체내로부터 정제한 Phenoloxidase)

  • 백승렬;조은정;유경희;김유삼;서정진;장정순
    • The Korean Journal of Zoology
    • /
    • v.39 no.1
    • /
    • pp.36-46
    • /
    • 1996
  • An endogenous phenoloxidase (EPO) from earthworm, Lumbricus rubellus, has been purified and characterized. The purified EPO using ammonium sulfate fractionation, Blue-2, Phenyl-, and Q-sepharose chromatography steps was revealed in SDS-PAGE as a single protein banri with Mr. of 59 kl)a. A native strudure of the enzyme was examined with an in situ staining of a nondenatudng-PAGE using DL-dopa as a substrate. The result showed that a single band due to the EPO activity was located siighdy above a standard polypeptide with Mr. of 210 kl)a. These fads indicate that the EPO is an oligomeric enzyme. The presence of a monophenolase activity of the purified EPO, which hydroxylates tyrosine to dopa, was confirmed by observing dopachrome accumulation at 475 nm at PH 8.0 with a typical lag phase during 60 mm. of meausrement. A series of inhibition study has been performed for the enzyme with several divalent cation chelators such as phenyithiourea (Flu), 1, lO-phenanthroline, EDTA, and EGTA. Among them, only V'flj inhibited the enzyme with 1C0.5 of 65 MM, which indicated that copper was critical for the catalysis of EPO. The enzyme was maximally active at 35'C and pH 8.0 when L-dopa to dopachrome conversion was spectrophotometricaily monitored at 475 nm. The apparent Km values of P0 for L-opa were obtained as 1.86 mM and 13.8 mM at pH 6.5 and 8.0, respectively. The catalytic efficiencies at both pH were almost identical [(kat/Km)pH8.0/(kcat/Km)pH6.5 = O.92] while the Vmax at p11 8.0 was 6.6-fold higher than that at pH 6.5. This fact may indicate that pH affeds the catalysis at substrate and/or enzyme-substrate complex level rather than the enzyme itself. Taken together, the EPO was an oligomeric enzyme which did not require proteolysis for its activation. These results also indicated that the enzyme can exist, at least, in part as a latent form In vivo, which might be distinct from the prophenoloxidase activating system. Therefore, it is pertinent to consider that there must be certain regulatory molecules or phenomena in L. rubellus which make the 1,0 in a latent form in vivo before the foreign invasions.

  • PDF

Changes of Vegetation Structure in Naejangsan District, Najangsan National Park for Twenty Years(1991~2010), Korea (내장산국립공원 내장산지구 20년간(1991~2010년) 식생구조 변화 연구)

  • Bae, Ji-Yoon;Kim, Ji-Suk;Lee, Kyong-Jae;Kim, Jong-Yup;Yeum, Jung-Hun
    • Korean Journal of Environment and Ecology
    • /
    • v.27 no.1
    • /
    • pp.99-112
    • /
    • 2013
  • This study aims to show the changes of characteristics of vegetation structure for 20 years(1991~2010) in Naejangsan National Park. As a result of analysis of actual vegetation, the mixed community of Quercus variabilis and Quercus serrata was distributed with 56.1%, and Q. variabilis community showed in southern steep slope with 17.6%. Pinus densiflora community(5.8%) was observed on the ridge and Carpinu tschonoskii community distributed in the slope of the valley with 6.6%. Zelkova serrata and Prunus sargentii community were distributed in valley. The classification by TWINSPAN, ordination by DCA considering importance percentage and property of vegetation class were divided into 4 communities, which are community I(P. densiflora-Q. variabilis community), community II(Q. variabilis community), community III(C. tschonoskii community) and community IV(Mixed deciduous broad-leaved trees community). The age of Pinus densiflora was 32years old and Q. serrata was 36 years old in the community I, that of Q. variabilis was 64 years old in the community II, Q. serrata was 46 years old and C. tschonoskii was 45 years old in the community III, and Acer palmatum was 54 years old and Cornus controversa was 47 years old in the community IV. As the result of Shannon's index of species diversity, the community Iwas ranged from 0.9751 to 1.4199, community II was ranged from 1.0765 to 1.3278, community III was ranged from 1.0353 to 1.2881, and community IV was ranged from 1.1412 to 1.3807. The change of vegetation structure analyzed through the comparison with results of studies carried out 20 years ago were natural selection of P. densiflora, expansion of Quercus spp. and increase of C. tschonoskii. Especially, A. palmatum is dominated by Q. variabilis in canopy layer like the result of study 20 years ago. A. palmatum was analysed by 14.6% in the canopy layer of only mixed deciduous broad-leaved trees community. As a result of analysis of habitat property of Q. variabilis and A. palmatum, Q. variabilis was distributed in dry area with the low value of pH, O.M., exchangeable cations and Avail. P, and A. palmatum was located in the wet valley with huge value of nourishment. The tendency of reduction of bio-diversity by Sasa borealis is same as previous study but, the distributed areas were reduced in Naejangsan area.

The Clinical Significance of Measurement of Serum Vascular Endothelial Growth Factor in Patients with Hemoptysis (객혈환자에서 혈청 Vascular Endothelial Growth Factor 검사의 유용성)

  • Lo, Dae-Keun;Kim, Seung-Joon;Lee, Sook-Young;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.2
    • /
    • pp.137-144
    • /
    • 2002
  • Background: Hemoptysis is an often alarming presenting symptom and VEGF is a major regulator of both normal and abnormal angiogenesis, including many inflarrunatory diseases. In this report the clinical significance of the serum VEGF level in patients with hemoptysis was investigated. Methods: Thirty-two patients with hemoptysis were evaluated. The estimated amount of hemoptysis, etiology and serum VEGF level was examined at admission and bronchial angiography was performed in 22 patients. In order to objectify the neovascularization status, one point for the presence of the A-V shunt, hypervascularity, vascular tortuosity was designated for a total of 0-3 points. Results: Mean quantity of hemoptysis was $172.4{\pm}270.4ml$. The mean angiographic neovascularization score was $1.23{\pm}0.75$. The serum VEGF level correlated with the quantity of hemoptysis(r=0.524, p=0.002) and with the angiographic neovascularization score(r=0.441, p=0.04). Using the standard diagnostic criterion for massive hemoptysis, the serum VEGF level of patients with massive hemoptysis($642.4{\pm}545.6$ pg/ml, n=13) was found to be higher than that of patients with non-massive hemoptysis($394.6{\pm}225.8$ pg/ml, n=19) (p=0.069). Conclusion: Regardless of the etiology, the serum VEGF may contribute to abnormal neovascularization in patients with hemoptysis. Therefore, it is suggested that serum VEGF measurements may help in predicting a massive hemoptysis.

Detection of Pyrazinamide Resistance in Mycobacterium Tuberculosis by Sequencing of pncA Gene (pncA 유전자의 염기 서열 결정에 의한 결핵균의 Pyrazinamide 내성 진단)

  • Hwang, Jee-Yoon;Kwak, Kyung-Rok;Park, Hye-Kyung;Lee, Ji-Seok;Park, Sam-Seok;Kim, Yun-Seong;Lee, Jung-Yoo;Chang, Chul-Hun;Lee, Min-Ki;Park, Soon-Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.1
    • /
    • pp.94-105
    • /
    • 2001
  • Background : Examining the biological susceptibility of Mycobacterium tuberculosis to pyrazinamide (PZA) in vitro is very difficult as PZA is inactive under normal culture conditions. The biological susceptibility test, an enzyme assay for Pzase activity, and a genetic test for pncA gene mutations, were performed in order to predict PZA resistance. Methods : 28 cultured clinical isolates of Mycobacterium tuberculosis were tested. The biological susceptibility was performed by the absolute concentration method using Lowenstein-Jensen media. The PZase activity was tested by means of Wayne's method. A 710-bp region includes the entire open reading frame of pncA was amplified and sequenced. Results : All six strains with positive PZase activity exhibited no pncA mutations with one strain showing a false resistance in the biological susceptibility test. Among the 22 strains with no PZase activity, 21 exhibited showed pncA mutations. In the biological susceptibility test, 20 strains were resistant, and one was susceptible, and the other flied to test. The mutation types varied with ten missense, one silent and one nonsense mutation 1 slipped-strand mispairing, and 6 frameshift mutations. Three strains had an adenine to guanine mutation at position -11 upstream of the start codon. Conclusion : The mutation at the pncA promotor region is frequent at -11 upstream position. Automatic sequencing of pncA is a useful tool for rapid and accurate detection of PZA resistant M. tuberculosis, and for demonstrating the epidemiological relatedness of the PZA resistant M. tuberculosis strains.

  • PDF