• Title/Summary/Keyword: 예열공정

Search Result 53, Processing Time 0.022 seconds

Permeation Efficiency of Sea Tangle (Laminaria japonica) Extract into Egg Using Temperature Change Method and Pressure (온도 변화 방법과 압력을 이용한 계란 내부로 다시마 추출물의 침투 효율)

  • Park, Yeo-Jin;Kim, Dong-Ho;Jang, Keum-Il
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.4
    • /
    • pp.544-549
    • /
    • 2014
  • In this study, the permeation efficiency (PE) of sea tangle (Laminaria japonica) extract (STE) into egg using the temperature change method (TCM) and pressure was investigated. STE was prepared in a volume of water equal to 10 times the weight of the sea tangle at $100^{\circ}C$ over a 3 hr period. The PE of iodine as a representative component of the STE as well as the total polyphenol content at ambient pressure were determined as follows: 1) after soaking in the STE at 30, 40, and $50^{\circ}C$ for 3 hr, and 2) after soaking in the STE at $4^{\circ}C$ immediately after soaking in distilled water at $50^{\circ}C$ for 1, 2, and 3 hr (TCM), respectively. The PE of iodine as well as the total polyphenol content improved as the temperature of the STE increased (P<0.05). The permeation of iodine was more rapid, and the total polyphenol content increased with the TCM (121 ${\mu}g/100$ mg and 1.74 mg/mL for 3 hr, respectively) compared to without the TCM (72 ${\mu}g/100$ mg and 1.48 mg/mL for 3 hr, respectively), and the highest PE was observed with the TCM after soaking at $50^{\circ}C$ for 3 hr. At a pressure of 5.0 MPa, the PE was more rapid with the TCM (139 ${\mu}g/100$ mg and 1.74 mg/mL for 90 min, respectively) than without the TCM (105 ${\mu}g/100$ mg and 1.56 mg/mL for 90 min, respectively). Consequentially, these results suggest that the preparation of seasonings and functional eggs using various components and bioactive substances is possible by the TCM.

Evaluation of Drying Performances by Hydrothermal Reaction of Sewage Sludge and Food wastes (하수슬러지 및 음식물류폐기물의 수열반응에 의한 건조 효율 평가)

  • Shin, Myung-Seop;Lee, Hyung-Don;Jeon, Yong-Woo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.1
    • /
    • pp.47-55
    • /
    • 2017
  • The technology for hydrothermal reaction of organic waste is one of the promising process to improve energy efficiency of biomass waste recycling system since moisture contents of treated biomass could be reduced at 40% or less than by dehydration processes. For these reasons, many parts of the world are interested in hydrothermal reaction of organic waste. In this paper, drying performances were evaluated with and without hydrothermal reaction of organic wastes which are sewage sludge and food wastes. For the hydrothermal reaction, organic wastes were treated at $200^{\circ}C$ for 1hr. Drying time of treated organic waste by hydrothermal reaction was reduced. In case of food waste drying at $100^{\circ}C$, drying time of treated wasted was reduced more 52.9% than non-treated. Hence, drying performances of sewage sludge and food wastes should be improved by hydrothermal reaction. Drying rates of treated wastes were considerably increased at preheat period of drying characteristic curve as followings; at $80^{\circ}C$ sludge as 148%, $100^{\circ}C$ sewage sludge as 151%, $80^{\circ}C$ food waste as 209%, $100^{\circ}C$ food waste as 366%. It means the surface area of treated wastes could be increased with destruction of cell membrane by hydrothermal reaction. However, the designer and operator of drying process should be careful, since enhanced drying rate cause the extension the decreasing drying period.

Enhancement of combustion efficiency of a air-cooled combustor system with single F.D. Fan Using CFD (전산유체역학을 이용한 단일 송풍기가 적용된 공냉식 연소설비의 효율개선)

  • Kim, Min-Choul;Shon, Byung-Hyun;Lee, Jae-Jeong;Park, Hung-Suck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.460-468
    • /
    • 2021
  • This study investigated the enhanced combustion efficiency of an "air-cooled combustion system" with single F.D. fan, and performed a numerical analysis for the operation and design conditions to increase the combustion efficiency. The combustion efficiency in an actual combustor was compared before and after the structure modification. Numerical analysis for application of a single fan revealed the difficulty of forming a turbulence for circular combustion conditions. This is because the supply ratio of combustion air supplied into 2 flow paths becomes irregular in the combustion furnace due to a change in friction force and pressure in each flow path. Subsequently, two methods of supplying air into the combustion furnace were analyzed numerically to obtain the optimal combustion conditions of an air-cooled combustion system. The first method involved injecting the preheated combustion air after a 180~360 degree rotation from the outer wall, whereas in the second method, the combustion air was injected into the combustion furnace in a tangential direction after primary heat exchange outside the combustion furnace, by applying a rotatable vane structure in the combustion furnace. Results reveal that application of a single F.D. fan to the air injection into a rotatable combustion furnace is desirable for optimization of the combustion conditions for applying a duct structure having a dual cooling wall for the cooling of the outer wall of the combustion furnace, and for maintaining perfect mixing in the combustion furnace. We therefore confirmed enhanced combustion efficiency by comparing the actual combustion efficiency before and after structure modification.