• Title/Summary/Keyword: 영재아

Search Result 155, Processing Time 0.02 seconds

DENTAL TREATMENT OF A PATIENT WITH SWYER JAMES UNDER GENERAL ANESTHESIA: A CASE REPORT (Swyer James syndrome환아의 전신마취 하 치아우식 치료: 증례보고)

  • Sung, Young Jae;Song, Ji Soo;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Shin, Teo Jeon
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.15 no.1
    • /
    • pp.60-64
    • /
    • 2019
  • Swyer-James syndrome (SJS), also known as Swyer-James-MacLeod syndrome and unilateral hyperlucent lung syndrome, is rare acquired pulmonary disorder develops secondary to infectious etiologies in early childhood. Viral respiratory infection such as adenoviruses or Mycoplasma pneumoniae in infancy or early childhood rarely cause Swyer-James syndrome. It is generally characterized on radiographs by a unilateral small lung with hyperlucency and air trapping on expiration. In many cases unaffected lung tissue functions normally, compensating for affected lung portion. Preoperative assessment is needed to determinate individual's pulmonary function. A 4-year-old boy with Swyer-James syndrome visited Seoul National University Dental Hospital Department of pediatric dentistry for caries treatment. Clinical and radiographic examinations revealed multiple carious lesions on deciduous teeth. Considering patient's underling disease, age, and level of cooperation, dental treatment under general anesthesia was scheduled. Dental treatment was done with composite resin and stainless-steel crown. Since ventilation of Swyer-James syndrome patients was diminished because of airway obstruction, close monitoring of ventilation is necessary during dental treatment. Considering pulmonary pathology, general anesthesia rather than sedation is recommended when special behavior management is required for dental treatment. Swyer-James syndrome patients can tolerate general anesthesia and surgery well, according to several reports.

A Study on the Comparison of Korea Good Manufacturing Practice (KGMP) Evaluation Criteria with Certification Criteria of Extramural Herbal Dispensaries (원외탕전실 평가인증기준과 KGMP 평가인증 기준과의 비교연구)

  • Hyeong-Gi Kim;Eui-Hyoung Hwang;Eun-Gyeong Lee;Byung-Mook Lim;Young-Jae Shin;Sun-Young Park;Byung-Cheul Shin
    • The Korea Journal of Herbology
    • /
    • v.38 no.6
    • /
    • pp.61-71
    • /
    • 2023
  • Objectives : This study aimed to find out the future direction of accreditation system of Extramural herbal dispensaries (EHD) by comparing the current criteria of EHD and the existing Korea good manufacturing practice (GMP) regulations. Methods : Among the accreditation criteria of EHD, criteria of general herbal medicine was compared with the pharmaceutical GMP of Korea. The regulations of the accreditation of EHD and the regulations of KGMP were compared and organized with similar things based on the index of KGMP. All criteria from both were extracted for each element, classified into key-words and evaluated by dividing them into the same, similar one and no-matching. Results : Among the 189 criteria of KGMP, 77 criteria were consistent with the accreditation of EHD, and 15 criteria were similar. Based on the accreditation of EHD, 70.4% of the criteria were consistent or similar to KGMP. There were a total of 27 key-words only in the GMP criteria and not in the EHD one. Hence, a total of 25 key-words only in the EHD criteria and not in the GMP one. There were 12 similar key-words, and among them, there were 4 key-words in which accreditation of EHD was more specific than the KGMP. Conclusions : The criteria of general herbal medicine in EHD showed a similar or equivalent level of accreditation criteria compared to that of pharmaceutical GMP in Korea, and it ts believed that it should be considered at the current level to reflect the characteristics of herbal medicine.

A Study on the Variable Factors for Brain Perfusion SPECT(Diamox) Scan (Brain Perfusion SPECT(Diamox) 검사의 수행결과에 영향을 주는 요인)

  • Lee, Jin-Hyeong;Kim, Sang-Eon;Park, Hyeon-Soo;Park, Yeoung-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.99-103
    • /
    • 2011
  • Purpose: Head movement during brain perfusion SPECT (Diamox) scan is a one of important issues which decreases image quality. It also causes repeated scans. This study was designed to evaluate variable factors causing scan failures. Materials and Methods: 676 patients (359 men, 317 women, age average $54.5{\pm}18.4$) for brain perfusion SPECT (Diamox) scan from March, 2010 to Feb. 2011 were used as a subject. Age data and the kind of disease(Moyamoya disease (MMD), None moyamoya disease (NMMD), Cerebral infarction (CI)), test performance outcome (success,failure) were collected. The head movement factors(gender, disease, age, head fixation device) were evaluated by chi-square test and logistic regression analysis Results: The result showed that men had higher scan failure rate than women. Seniors in seventies(men 3.4%, women 1.5%) showed the most highest failure rate. Using head fixation device increased scan success rate up to 94.4~97.7%. The scan success rate is dependent upon gender, head fixation device by chi-square test(${\chi}^2$=3.8 (df=1, p<0.05), ${\chi}^2$=10.4 (df=1, p<0.001)) Gender, disease(CI), head fixation device showed very effective result in logistic regression analysis.(Wald=3.3 (p<0.07), Wald=3.7 (p<0.05), Wald=9.3 (p<0.05) Conclusion: It is demonstrated that gender, disease, using head fixation device is statistically very useful factors. Especially, head fixation device is a main key minimizing repeated scan.

  • PDF

Scientifically Talented Students' Image of Science Museums and Their Preferred Topics for Exhibits - Focused on Students in Gwangju City - (과학 우수아의 과학관에 대한 이미지와 기대 전시 내용 - 광주지역 학생을 중심으로 -)

  • Kim, Jinkuk;Park, Jongwon
    • Journal of The Korean Association For Science Education
    • /
    • v.33 no.7
    • /
    • pp.1431-1449
    • /
    • 2013
  • This study is based on the assertion that science museums should consider visitors' views and expectations as they are not satisfied in many cases. In this study, we investigated 31 scientifically gifted students and 177 science high school students about their image of science museums. Using the questionnaire, it was found that only 51% of students visited science museums; however, the average number of visits was 4.2. This means that students tended to re-visit after the first visit of the science museum. Students had a 'good' image of science museums when they incurred hands-on experiences and observed new, interesting, curious and funny exhibits. And students had a 'bad' image of science museums due to the following aspects: lack of new and interesting exhibits, information and guide, diverse contents, and hands-on experience; deficiencies in environment; and inadequacy of the management, operation and composition of exhibits. Therefore, they hoped that science museums will provide more hands-on experiences and experiments, new and interesting exhibits, systematic management and composition of exhibits, information and guides, and a good environment. So science museums need to pay special attention to aspects like management, information guides and environment for the first-time visitors. Based on the above results, we suggested "Directions for a good science museum based on students' views". While asking students what topics they wanted to know and learn in a science museum, each student was given the choice of four topics; eventually, 2.9 answers overlapped for each topic. When classifying students' topics into four main themes for the Gwangju National Science Museum, the order from the most popular theme to the least one was 'science in everyday life', 'ocean/space/future science', 'light and science', and 'culture, art and science'. Among the topics mentioned by students, only 37% are exhibited in Seoul, Gwacheon, Daejeon, or Gwangju science museums. We hope that the results and research methods will be used for evaluation, re-construction, and reinvigorated presentation of science museums.

Effects of Temperature and Saturation on the Crystal Morphology of Aragonite (CaCO3) and the Distribution Coefficient of Strontium: Study on the Properties of Strontium Incorporation into Aragonite with respect to the Crystal Growth Rate (온도와 포화도가 아라고나이트(CaCO3)의 결정형상과 스트론튬(Sr)의 분배계수에 미치는 영향: 결정성장속도에 따른 아라고나이트 내 스트론튬 병합 특성 고찰)

  • Lee, Seon Yong;Chang, Bongsu;Kang, Sue A;Seo, Jieun;Lee, Young Jae
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.2
    • /
    • pp.133-146
    • /
    • 2021
  • Aragonite is one of common polymorphs of calcium carbonate (CaCO3) and formed via biological or physical processes through precipitation in many different environments including marine ecosystems. It is noted that aragonite formation and growth as well as the substitution of trace elements such as strontium (Sr) in the aragonite structure would be dependant on several key parameters such as concentrations of chemical species and temperature. In this study, properties of the incorporation of Sr into aragonite were investigated over a wide range of various saturation conditions and temperatures similar to the marine ecosystem. All pure aragonite samples were inorganically synthesized through a constant-addition method with varying concentrations of the reactive species ([Ca]=[CO3] 0.01-1 M), injection rates of the reaction solution (0.085-17 mL/min), and solution temperatures (5-40 ℃). Pure aragonite was also formed even under the Sr incorporation conditions (0.02-0.5 M, 15-40 ℃). When temperature and saturation index (SI) with respect to aragonite increased, the crystallinity and the crystal size of aragonite increased indicating the growth of aragonite crystal. However, it was difficult to interpret the crystal growth rate because the crystal growth rate calculated using BET-specific surface area was significantly influenced by the crystal morphology. The distribution coefficient of Sr (KSr) into aragonite decreased from 2.37 to 1.57 with increasing concentrations of species (Ca2+ and CO32-) at a range of 0.02-0.5 M. Similarly, it was also found that KSr decreased 1.90 to 1.54 at a range of 15-40 ℃. All KSr values are greater than 1, and the inverse correlation between the KSr and the crystal growth rate indicate that Sr incorporation into aragonite is in a compatible relationship.