• Title/Summary/Keyword: 영상 평가

Search Result 6,353, Processing Time 0.037 seconds

Radiation Shielding to Minimize Image Information Loss (영상 정보 손실을 최소화하는 방사선 차폐체 연구)

  • Su-han Jang;Sang-Hyeun Park;Myeong-Sik Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.449-457
    • /
    • 2023
  • Shielding for reducing exposure dose can make the diagnosis limited. The purpose of this study is to increase the efficiency of radiation protection and minimize the loss of image information by producing the shielding made of the water and the contrast medium which has different proportion and finding out the ideal proportion of them. Each shielding materials were made of water and water-soluble iodine contrast medium with the different proportion. The attenuation rate of absorbed dose was evaluated by the shielding materials in the plastic contents for measuring the efficiency of the radiation protection. As a result, the higher ratio of the contrast medium, the more efficient it is for radiation attenuation. The anatomical structure was observed most properly in case of the solution with 20 ml of the contrast medium and most difficultly in case of more than 60 ml of the contrast medium. In case of the signal intensity between skeleton and gas, the difference of average value had a significant as p < 0.001. Shielding with contrast medium attenuates less than the conventional shielding but in the examination for the sensitive part to radiation, it can be used to minimize the loss of the image information and reduce the exposure dose.

Diffusion-Weighted MR Neurography with Unidirectional Motion-Probing Gradient to Evaluate Lumbar Nerve Roots at 1.5T MR (요추 신경근 평가를 위한 1.5T MR의 단일 방향 경사자장을 사용한 확산강조 자기공명신경조영)

  • Na Yeon Yoon;Doo Hoe Ha;Sang Min Lee;Hye Jung Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.607-617
    • /
    • 2024
  • Purpose Recent studies have demonstrated the usefulness of diffusion-weighted MR neurography (DW MRN) for assessing nerve roots. This study aimed to evaluate the utility of DW MRN with a unidirectional motion-probing gradient (MPG) for the lumbar nerve roots at 1.5T MR. Materials and Methods Sixty-four lumbar spine MRI scans with DW MRN using anteroposterior unidirectional MPG were retrospectively analyzed. Any changes in the 512 lumbar spinal nerve roots from L3 to S1 were evaluated using T2-weighted imaging (T2WI), contrast-enhanced T1-weighted imaging (CE T1WI), and DW MRN, with agreement and correlation analysis. Results T2WI revealed compression of 78 nerve roots, and CE T1WI revealed 52 instances of nerve root enhancement. Sixty-seven nerve roots showed swelling and hyperintensity on DW MRN. A total of 42 nerve roots showed changes in the CE T1WI and DW MRN sequences. Moderate to substantial agreement and moderate positive correlation were observed between DW MRN and CE T1WI, as well as DW MRN and T2WI (κ = 0.59-0.65, ρ = 0.600-0.653). Conclusion DW MRN with unidirectional anteroposterior MPG can help evaluate neuritisrelated changes in spinal nerve roots and could serve as a sequence capable of complementing or substituting gadolinium CE imaging.

The Research on Compression Image Quality of Full Field Digital Mammography on PACS Environment (PACS환경에서 Full Field Digital Mammography 영상의 압축 화질평가에 관한 연구)

  • Jeong, Jaeho;Kim, Eunsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.147-153
    • /
    • 2014
  • We tried to assessment about characteristics of image through quantitative evaluation method and qualitative evaluation method in Full Field Digital Mammography. It satisfied an approval standard of ten score regardless of compression ratio measuring detection score after compressing and appling an algorithm of JPEG2000 orJPEG compression targeting ACR accreditation phantom. Also, it was apparent that when we selected and compressed the image of real fine lesion and measured a change of diagnosis ability magnifing over 50 percent after compressing over 20:1 ratio, it had a strong influence on diagnosis ability. We realized that the difference between the original image according to compression ratio measuring a quantitative evaluation which is PSNR,RMSE,MAE and SSIM was relatively allowable.

An Enhanced Perceptual No-Reference Scheme for Video Quality Measurement Using the Histogram Analysis of Luminance and Chrominance (휘도, 색차의 분포도 분석을 통한 개선된 인지적 무기준법 영상 화질 평가방법)

  • Kim, Yo-Han;Sung, Duk-Gu;Hong, Seung-Seok;Shin, Ji-Tae
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.185-188
    • /
    • 2008
  • 영상의 화질을 평가하는 방법은 어떤 정보를 기준으로 평가하느냐에 따라서 전체 기준법 (Full Reference), 부분기준법 (Reduced Reference) 그리고 무기준법 (No Reference)으로 나눌 수 있다. 이중 무기준법은 수신 영상만을 가지고 측정하기 때문에, 다른 방법보다 활용범위가 넓다. 또한, 최근 사람의 눈의 특성을 고려한 인지적(Perceptual)화질평가 방법이 많이 논의되어, 사람이 실제 보고 느끼는 바를 객관화 시키는 방법이 개발되어 왔다. 이들 화질평가 방법들에 대해 많은 연구가 수행되고 있으며, 국제기구들을 통하여 이들 지표들에 대한 표준화가 진행되고 있다. 본 논문에서는 휘도, 색차의 분포도를 분석하여 원본의 화질을 예측하는 방법을 통해서, 기존 무기준법의 정확도를 높이고자 한다. 영상신호의 양자화나 부호화로 인해 임계값을 벗어나는 값들이 생기게 되며, 이 값을 휘도, 색차의 분포도 분석으로 예측하여 화질평가를 수행하게 된다. 실험 결과 제안된 방법의 상관도는 다른 방법보다 높은 것으로 나타났다.

  • PDF

Role of Redistribution and 24 Hour Reinjection Images to assess Myocardial Viability in Patients with Acute Myocardial Infarction (급성심근경색환자의 심근생존능 평가에 있어서 T1-201 재분포영상과 24시간 재주사영상의 역할)

  • Yoon, Seok-Nam;Pai, Moon-Sun;Park, Chan-H.;Yoo Myung-Ho;Choi, Byung-Il William
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.325-331
    • /
    • 1998
  • Purpose: We evaluated the importance of redistribution and 24 hour reinjection images in T1-201 SPECT assessment of myocardial viability after acute myocardial infarction (AMI). Materials and Methods: We performed dipyridamole stress-4 hour redistribution-24 hour reinjection T1-201 SPECT in 43 patients with recent AMI (4-16 days). The myocardium was divided into 16 segments and perfusion grade was measured visually with 4 point score from 0 to 3 (absent uptake to normal uptake). A perfusion defect with stress score 2 was considered moderate. A defect was considered severe if the stress score was 0 or 1 (absent uptake or severe perfusion decrease). Moderate defect on stress image were considered viable and segments with severe defect were considered viable if they showed improvement of 1 score or more on redistribution or reinjection images. We compared the results of viability assessment in stress-redistribution and stress-reinjection images. Results: On visual analysis, 344 of 688 segments (50%) had abnormal perfusion. Fifty two (15%) had moderate perfusion defects and 292 (85%) had severe perfusion defects on stress image. Of 292 severe stress defects, 53 were irreversible on redistribution and reversible on reinjection images, and 15 were reversible on redistribution and irreversible on reinjection images. Two hundred twenty four of 292 segments (76.7%) showed concordant results on stress-redistribution and stress-reinjection images. Therefore 24 hour reinjection image changed viability status from necrotic to viable in 53 segments of 292 severe stress defect (18%). However, myocardial viability was underestimated in only 5% (15/292) of severe defects by 24 hour reinjection. Conclusion: The 24 hour reinjection imaging is useful in the assessment of myocardial viability. It is more sensitive than 4 hour redistribution imaging. However, both redistribution and reinjection images are needed since they complement each other.

  • PDF

Improved Focal Liver Lesion Detection by Increasing Flip Angle During Gadoxetic Acid-Enhancement in MRI (Gadoxetic acid 조영증강 자기공명영상에서 숙임각 변화에 따른 국소 간종양 검출능 비교)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2015
  • To study the differences of focal liver lesion image detection at 3 minute, 10 minute and 15 minute time points on gadoxetic acid (GA)'s enhanced MR imaging with a flip angle (FA) of $30^{\circ}$ compared with a $11^{\circ}$. The subjects were 69 patients evaluated with GA enhanced MR imaging with 3.0T MR scanner. The patients are total 35(23 men and 7 women at the mean age of 60.4 years), hepatocellular carcinoma(23) and metastsis(12) except for normal, cyst and hemangioma. After GA was injected, FA $11^{\circ}$ and $30^{\circ}$ images were obtained at 3 minute, 10 minute and 15 minute time points respectively. After quantitative and qualitative assessment of each image was done, statistical analysis was performed by using the independent sample T-test. From both quantitative and qualitative assessment of 3 minute and 10 minute MR images after the injection of GA, FA $30^{\circ}$ images was found to be superior than FA $11^{\circ}$, but there were no statistical significance. However, at 15 minute time point, Statistically significant FA $30^{\circ}$ image(p<0.05) was better than FA $11^{\circ}$ therefore, the FA $30^{\circ}$ improves the focal liver lesion detection. FA $30^{\circ}$ of MR image can detect liver lesion more sensitively than the existing $FA11^{\circ}$ image after GA contrast enhancement at 15 minute time point.

Self-Reported Symptoms and Stereopsis in Viewing 2D and 3D Images (2D와 3D입체 영상 시청에서 나타난 자각 증상과 입체시)

  • Lee, Wook-Jin;Son, Jeong-Sik;Kwak, Ho-Won;Kim, In-Su;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.83-90
    • /
    • 2011
  • Purpose: This study aimed to compare and assess whether there was a relation between self-reported symptom and stereopsis in viewing an anaglyph 3D and a general 2D image. Methods: Seventy subjects (38 males, 32 females) were students ranging in age from 20 to 30 years. Subjects' symptoms were investigated by a questionnaire after viewing the 2D image and the anaglyph 3D image using red-green glasses for 30 minutes. Titmus circles and TNO stereopsis tests were performed before and after the images. A correlation between symptom and stereopsis was evaluated. Results: Both ocular and nonocular symptom in viewing 3D image were higher than those in 2D image. Titmus circles stereopsises using polarized filters were not changed before and after viewing images, but TNO stereopsises using color filters such as red-green glasses were increased after viewing 3D image. Ocular symptom and TNO stereopsis were increased after viewing 3D image, and there was a good correlation between them (r=0.605). Conclusions: Better stereopsises before viewing 3D are relatively lower ocular symptoms in viewing 3D image. But symptoms are increased in viewing anaglyph 3D image for a short-time and improvement of TNO steropsis is poorly associated with the relief of ocular symptoms. This tendency seems to be related with an adaptation to anaglyph 3D image with red-green glasses.

Image Enhancement and Clinical Evaluation in Digital Chest Radiography (디지털 방사선 흉부영상의 영상개선과 임상평가)

  • Kim, Sung-Hyun;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.143-149
    • /
    • 2008
  • The aim of this study is to suggest the method for image enhancement of digital chest radiograph and evaluate clinically the quality of the resultant image. A nonlinear iterative filter was developed in order to reduce quantum noise preserving edge. Dynamic range was adjusted and adaptive image enhancement was performed based on the property of anatomic region and the degree of compatibility with neighboring pixels. The lung fields were enhanced appropriately to visualize effectively vascular tissue, bronchus and lung tissue with the desired mediastinum enhancement. Clinic evaluation was performed by three radiologists with at least 8 years experience. The anatomic regions of 11 in PA and 9 in Lateral were observed carefully in each 100 radiographs according to ITU (International Telecommunication Union) recommendation 500 protocol. The result showed the mean 3.4 between good and adequate. This means that the clinical utility of the image quality is enough. In this study, image enhancement was carried out considering image display device and human perceptual system to prevent the loss of useful anatomic information. In order to increase the diagnostic accuracy in digital radiograph, the continuous study on image enhancement is needed.

  • PDF

Expert Opinions and Recommendations for the Clinical Use of Quantitative Analysis Software for MRI-Based Brain Volumetry (뇌 자기공명영상 뇌용적 분석 소프트웨어의 임상적 적용에 대한 전문가 의견과 권고안)

  • Ji Young Lee;Ji Eun Park;Mi Sun Chung;Se Won Oh;Won-Jin Moon;Aging and Neurodegeneration Imaging (ANDI) Study Group, Korean Society of Neuroradiology (KSNR)
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1124-1139
    • /
    • 2021
  • The objective assessment of atrophy and the measurement of brain volume is important in the early diagnosis of dementia and neurodegenerative diseases. Recently, several MR-based volumetry software have been developed. For their clinical application, several issues arise, including the standardization of image acquisition and their validation of software. Additionally, it is important to highlight the diagnostic performance of the volumetry software based on expert opinions. We instituted a task force within the Korean Society of Neuroradiology to develop guidelines for the clinical use of MR-based brain volumetry software. In this review, we introduce the commercially available software and compare their diagnostic performances. We suggest the need for a standard protocol for image acquisition, the validation of the software, and evaluations of the limitations of the software related to clinical practice. We present recommendations for the clinical applications of commercially available software for volumetry based on the expert opinions of the Korean Society of Neuroradiology.

Evaluation of Image Quality for Compressed SENSE(CS) Method in Cerebrovascular MRI: Comparison with SENSE Method (뇌혈관자기공영영상에서 Compressed SENSE(CS) 기법에 대한 영상의 질 평가: SENSE 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.999-1005
    • /
    • 2021
  • The object of this research is CS, which increases resolution while shortening inspection time, is applied to MRA to compare the quality of images for SENSE and CS techniques and to evaluate SNR and CNR to find out the optimal techniques and to provide them as clinical basic data based on this information. Data were analyzed on 32 patients who performed TOF MRA tests at a university hospital in Chung cheong-do (15 males, 17 females), ICA stenosis:10, M1 Aneurysm:10, and average age 53 ± 4.15). In the inspection, the inspection equipment was Ingenia CX 3.0T, Archieva 3.0T, and 32 channel head coil and 3D gradient echo as a method for equipment data. SNR and CNR of each image were measured by quantitative analysis, and the quality of the image was evaluated by dividing the observer's observation into 5 grades for qualitative evaluation. Imaging evaluation is described as being significant when the p-value is 0.05 or less when the paired T-test and Wilcoxon test are performed. Quantitative analysis of SNR and CNR in TOF MRA images Compared to the SENSE method, the CS method is a method measurement method (p <0.05). As an observer's evaluation, the sharpness of blood vessels: CS (4.45 ± 0.41), overall image quality: CS (4.77 ± 0.18), background suppression of images: CS (4.57 ± 0.18) all resulted in high CS technique (p = 0.000). In conclusion, the Compressed SENSE TOF MRA technique shows superior results when comparing and evaluating the SENSE and Compressed SENSE techniques in increased flow rate magnetic resonance angiography. The results are thought to be the clinical basis material in the 3D TOF MRA examination for brain disease.