• Title/Summary/Keyword: 영상 강조

Search Result 785, Processing Time 0.029 seconds

A Change of Apparent Diffusion Coefficient in Diffusion Weighted Imaging Applied with Rectangular FOV Technique (확산강조영상 검사 시 rectangular FOV 적용에 따른 ADC 값의 변화)

  • Na, Sa-Ra;Choi, Kwan-Woo;Koo, No-Hyun;Yoo, Beong-Gyu;Son, Soon-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.545-550
    • /
    • 2016
  • The purpose of this study is to improve the mapping between functional image and conventional image by using rectangular FOV technique. Diffusion weighted imaging which is widely used for stroke was acquired by reducing the FOV and compared each Apparent Diffusion Coefficient(ADC). As a result, there is no significant difference of each ADC value in one-way-anova analysis and post-hoc analysis. Thus, Mismatching problem may be improved by matching the FOV with rectangular FOV technique because there is no difference in ADC values.

A Study on Various Attention for Improving Performance in Single Image Super Resolution (초고해상도 복원에서 성능 향상을 위한 다양한 Attention 연구)

  • Mun, Hwanbok;Yoon, Sang Min
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.898-910
    • /
    • 2020
  • Single image-based super-resolution has been studied for a long time in computer vision because of various applications. Various deep learning-based super-resolution algorithms are introduced recently to improve the performance by reducing side effects like blurring and staircase effects. Most deep learning-based approaches have focused on how to implement the network architecture, loss function, and training strategy to improve performance. Meanwhile, Several approaches using Attention Module, which emphasizes the extracted features, are introduced to enhance the performance of the network without any additional layer. Attention module emphasizes or scales the feature map for the purpose of the network from various perspectives. In this paper, we propose the various channel attention and spatial attention in single image-based super-resolution and analyze the results and performance according to the architecture of the attention module. Also, we explore that designing multi-attention module to emphasize features efficiently from various perspectives.

Dynamic Contrast-Enhanced MR Imaging in Detecting Local Tumor Progression after HIFU Ablation of Localized Prostate Cancer (국소적 전립선암의 고강도 집속 초음파 치료 후 국소적 암 재발의 발견과 역동적 조영증강 자기공명영상의 역할)

  • Park, Jung Jae;Kim, Chan Kyo;Lee, Hyun Moo;Park, Byung Kwan;Park, Sung Yoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.192-199
    • /
    • 2013
  • Purpose : To retrospectively evaluate the diagnostic performance of dynamic contrast-enhanced MR imaging (DCE-MRI) in detecting recurrent prostate cancer after HIFU of clinically localized cancer, as compared with T2-weighted imaging (T2WI). Materials and Methods: Twenty-six patients with increased prostate-specific antigen levels after HIFU were included in this study. All MR examinations were performed using T2WI and DCE-MRI, followed by transrectal ultrasound-guided biopsy. MRI and biopsy results were correlated in six prostate sectors. Residual or recurrent cancer after HIFU was defined as local tumor progression if biopsy results showed any cancer foci. Two independent readers interpreted the MR images. Results: Of 156 prostate sectors, 51 (33%) were positive for cancer in 17 patients. For detecting local tumor progression, the sensitivity of DCE-MRI and T2WI was 80% and 57% for reader 1 (P < 0.001) versus 84% and 61% for reader 2 (P < 0.001), respectively. The specificity and overall accuracy between DCE-MRI and T2WI showed no statistical difference in both readers (P > 0.05). Interobserver agreement of DCE-MRI and T2WI was moderate and fair, respectively. Conclusion: For detecting local tumor progression of prostate cancer after HIFU, DCE-MRI was more sensitive than T2WI, with less interobserver variability.

The Age-related Microstructural Changes of the Cortical Gray and White Matter Ratios on T2-, FLAIR and T1- weighted MR Images (T2, FLAIR, T1 강조 MR영상에서 나이에 따른 뇌피질의 회질과 백질의 미세구조 변화)

  • Choi, Sun-Seob;Kim, Whi-Young;Lee, Ki-Nam;Ha, Dong-Ho;Kang, Myong-Jin;Lee, Jin-Hwa;Yoon, Seong-Kuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.32-40
    • /
    • 2011
  • Purpose : The purpose of this study was to investigate the microstructural changes according to aging on the thickness and signal intensity (SI) of the cortical gray matter (GM) and white matter (WM) on the T2-, fluid-attenuated inversion recovery (FLAIR) and T1-weighted MR images in normal subjects. Materials and Methods : The 10, 20, 30, 40, 50, 60, 70, 80 and 90 year age groups of men and women (each 10 individuals) who underwent routine brain MRI, including the T2-, FLAIR and T1-weighted images, were selected for this study. We measured the thickness and the SI of the cortical GM and WM at the postcentral gyrus, which has an even thickness at the level of centrum semiovale, on the axial scans and we calculated the mean values of the thickness ratio of the gray/white matter (TRGW) and the signal intensity ratio of the gray/white matter (SRGW), and we compared the ratios of each age group. Results : On the T2-weighted images, the TRGWs were 0.81 and 0.79 at the age of 10 and they were 0.73 and 0.71 at the age of 90 in the men and women, respectively. So, the GM thickness was decreased more than the WM thickness was with aging. On the FLAIR images, the TRGWs were 1.09 and 1.00 at the age of 10 and they were 1.11 and 0.95 at the age of 70 in the men and women, respectively. On the T1-weighted images, the TRGWs were 0.66 and 0.80 at the age of 10, and the ratio was changed to 0.90 and 0.78 at the age of 90 in the men and women, respectively. On the T2-weighted image, the SRGWs were 1.53 and 1.43 at the age of 10, and they were 1.23 and 1.27 at the age of 90 in the men and women, respectively. On the FLAIR images, the SRGWs were 1.23 and 1.25 at the age of 10 and they were 1.06 and 1.05 at the age of 90 in the men and women, respectively. On the T1-weighted images, the SRGWs were 0.86 and 0.85 at the age of 10, and they were 0.90 and 0.87 at the age of 90 in the men and women, respectively. Conclusion : We suggest that the age-related microstructural changes of the thickness and the SI of the cortical GM and WM on the T2-, FLAIR and T1-weighted images are unique, and so this knowledge will be helpful to differentiate neurodegenerative disease from normal aging of the brain.

A study on image distortion improvement using silicon device in thyroid diffusion MRI images (갑상선의 확산강조영상 검사 시 실리콘 이용한 뒤틀림 감소에 관한 연구)

  • Choi, Kwan-Woo;Seo, Dae-Keon;Lee, Ho-Beom;Goh, Hee-Jin;Na, Sa-Ra;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4380-4386
    • /
    • 2014
  • This study was conducted to minimize the imaging distortion by reducing the differences in susceptibility between the tissue and air surrounding it while performing a thyroid diffusion imaging procedure. The study group was composed of 23 healthy adults. Thyroids with many distortions near the air, larynx, and trachea were chosen to test and evaluate the diffusion imaging difference between before and after an application of silicon. As a result, there was reduced distortion with silicon application, and the differences decreased from 30% to 10%. According to One-way ANOVA and Duncan's post-hoc test, there were no significant differences between imaging with a silicon application and T2 imaging of the surface area, which was the standard image. In conclusion, this study presented a radical improvement in reducing the distortions in imaging by compensating for an uneven tissue surface near air without affecting the magnetic resonance contrast and complicating the imaging processes.

T1-weighted MR Imaging of the Neonatal Brain at 3.0 Tesla: Comparison of Spin Echo, Fast Inversion Recovery, and Magnetization-prepared Three Dimensional Gradient Echo Techniques (3T 자기공명영상 장비에서 신생아 뇌의 T1 강조 영상: 스핀에코, 고속 역전회복, 자기화 삼차원 경사에코기법의 비교)

  • Jeong, Jee-Young;Yoo, So-Young;Jang, Kyung-Mi;Eo, Hong;Lee, Jung-Hee;Kim, Ji-Hye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the usefulness of fast inversion recovery (FIR) and magnetization-prepared three dimensional gradient echo sequence (3D GRE) T1-weighted sequences for neonatal brain imaging compared with spin echo (SE) sequence in a 3T MR unit. Materials and Methods: T1-weighted axial SE, FIR and 3D GRE sequences were evaluated from 3T brain MR imaging in 20 neonates. The signal-to-noise ratio (SNR) of different tissues was measured and contrast-to-noise ratios (CNR) were determined and compared in each of the sequences. Visual analysis was carried out by grading gray-white matter differentiation, myelination, and artifacts. The Wilcoxon signed ranked test was used for evaluation of the statistical significance of CNR differences between the sequences. Results: Among the three sequences, the 3D GRE had the best SNRs. CNRs obtained with FIR and 3D GRE were statistically superior to those obtained with SE; these CNRs were better on the 3D GRE compared to the FIR. Gray to white matter differentiation and myelination were better delineated on the FIR and 3D GRE than the SE. However, motion artifacts were more commonly observed on the 3D GRE and flow-related artifacts of vessels were frequently seen on the FIR. Conclusion: FIR and 3D GRE are valuable alternative T1-weighted sequences to conventional SE imaging of the neonatal brain at 3T providing superior image quality.

  • PDF

Evaluation of Traumatic Intracranial Hemorrhage Using Computed Tomography and Magnetic Resonance Imaging in Four Dogs (개에서 컴퓨터단층촬영술과 자기공명영상을 이용한 창상성 두개관내 출혈의 평가)

  • Choi Ho-Jung;Lee Ki-Ja;Kang Sang-Kyu;Lee Hee-Chun;Chang Dong-Woo;Lee Ki-Chang;Jeong Seong-Mok;Cho Sung-Whan;Lee Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.96-101
    • /
    • 2006
  • Four dogs with neurologic dysfunction resulted from intracranial hemorrhage by head trauma were referred to Veterinary Medical Teaching Hospital, Chungnam National University. There were no remarkable findings in survey radiography in four cases. CT and MRI scans were diagnostic in these cases. Three dogs underwent CT scanning. On CT images, the lesion was hyperdense and was not enhanced after intravenous contrast administration in dog 1 and dog 2. On CT of dog 4, there was no significant finding. All of four dogs were verified by dorsal, sagittal, and transverse T1-weighted (T1W) and T2-weighted (T2W) images. Appearance of the lesions in dog 1 and dog 2 was isointense (dog 2) or isointense with hyperintense rim (dog 1) on T1W images and hyperintense on T2W images. In dog 3 and dog 4, there were hypointense and hyperintense lesions on T1Wand T2W images respectively. The lesions in four dogs were located in the left intracerebral region, intracerebral and cerebellovestibular region, subdural space, and right cerebral hemisphere, respectively.

Quantitative evaluation of MRI distortion using orthopedic prosthetic metal (정형보철용 금속을 이용한 자기공명영상왜곡의 정량적 평가)

  • Kim, Hyeonggyun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.57-62
    • /
    • 2013
  • Despite the many advantages of magnetic resonance imaging in orthopedic prosthetic body image distortion to the differences in the magnetic susceptibility occurs. Attached to the phantom and pork produced by the same $65{\times}15{\times}2mm$ stainless steel and titanium specimen examined the relationship between magnetic resonance imaging and phantom images, the signal intensity changes of the subcutaneous tissue, fat-suppressed quantitative assessment of the degree through the length of image distortion and pig bones. Stainless steel to titanium to 2.8 times 4.4 times in the longitudinal direction than in the direction of the height of large image distortion, signal strength is relatively low 58.5%. Normal 56.2% compared to the subcutaneous tissue, fat-suppressed, were stainless steel 16.04%, 54.53% titanium. Experimental results than the diagnostic value of magnetic resonance imaging (MRI) images of stainless steel with a titanium metal if better could see.

Segmentation of MR Brain Image Using Scale Space Filtering and Fuzzy Clustering (스케일 스페이스 필터링과 퍼지 클러스터링을 이용한 뇌 자기공명영상의 분할)

  • 윤옥경;김동휘;박길흠
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.4
    • /
    • pp.339-346
    • /
    • 2000
  • Medical image is analyzed to get an anatomical information for diagnostics. Segmentation must be preceded to recognize and determine the lesion more accurately. In this paper, we propose automatic segmentation algorithm for MR brain images using T1-weighted, T2-weighted and PD images complementarily. The proposed segmentation algorithm is first, extracts cerebrum images from 3 input images using cerebrum mask which is made from PD image. And next, find 3D clusters corresponded to cerebrum tissues using scale filtering and 3D clustering in 3D space which is consisted of T1, T2, and PD axis. Cerebrum images are segmented using FCM algorithm with its initial centroid as the 3D cluster's centroid. The proposed algorithm improved segmentation results using accurate cluster centroid as initial value of FCM algorithm and also can get better segmentation results using multi spectral analysis than single spectral analysis.

  • PDF

A Study of Painterly Stroke Rendering Techniques Using Histogram Matching (히스토그램 매칭을 이용한 회화적 스트로크 렌더링 기법 연구)

  • 용한순;이수연;윤경현
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10b
    • /
    • pp.694-696
    • /
    • 2003
  • 본 논문은 회화적 렌더링(painterly rendering)을 위한 다양한 크기를 갖는 곡선 브러시 스트로크(brush stroke)의 생성에 관한 알고리즘과 그 구현 방법을 다루고 있다. 논문에서 제시하는 알고리즘은 한 장의 영상을 입력으로 하여. 화가가 손으로 그린 듯한 느낌을 주는 결과 영상을 만들어 낸다. 결과 영상은 브러시의 크기에 따라 몇 개의 계층(layer)으로 구성되며 각 계층들은 일련의 스플라인 커브(spline curve)로 모델링된 곡선 브러시 스트로크들로 이루어진다. 또한 결과 영상의 회화적 느낌을 강조하기 위하여 입력 영상의 색상을 변환하는 과정을 포함하고 있다.

  • PDF