• Title/Summary/Keyword: 영상품질평가

Search Result 428, Processing Time 0.033 seconds

Network-Adaptive Transport Error Control for Reliable Wireless Media Transmission (신뢰성 있는 무선 미디어 전송을 위한 네트워크 적응형 전송오류 제어)

  • Lee Chul-Ho;Choi Jeong-Yong;Kwon Young-Woo;Kim Jongwon;Shin Jitae;Jeon Dong-San;Kim Jae-Gon
    • Journal of Broadcast Engineering
    • /
    • v.10 no.4 s.29
    • /
    • pp.548-556
    • /
    • 2005
  • In wireless network environments, wireless channels are characterized by time-varying fading and interference conditions, which may lead to burst packet corruptions and delay variation. This can cause severe quality degradation of streaming media. To guarantee successful transmission of media over the hostile wireless networks, where channel conditions are highly fluctuating, a flexible and network-adaptive transport method is required. Thus, we propose a network-adaptive transport error control consisting of packet-level interleaved FEC and delay-constrained ARQ, which acts as an application-level transport method of streaming media to alleviate burst packet losses while adapting to the changing channel condition in wireless networks. The performances of the proposed network-adaptive transport error control, general error control schemes, and hybrid schemes are evaluated by a developed simulator at the transport-level and video quality of streaming media. Simulation results show that the proposed mechanism provides the best overall performance among compared other schemes in terms of the transport-level performance of error control and the performance of video quality for streaming media.

Reducing Methods of Patient's Exposed Dose Using Auto Exposure Control System in Digital Radiography (디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안)

  • Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • This study was carried out to reduce patient dose through focus-detector distance, kilovoltage, and a combination of copper filters. In the C, L-spine lateral, Skull AP views were obtained by making changes of 60-100 kV in tube voltage and of 100-200 cm in focus-detector distance and by adding a copper filter when using an auto exposure control device in the digital radiography equipment. The incident dose showed 90 kV, 0.3 mmCu in C-spine lateral with 0.06 mGy under the condition of 200 cm; 100 kV, 0.3 mmCu with 0.40 mGy under the condition of 200 cm and 90 kV 0.3 mmCu in Skull AP with the lowest value of 0.24 mGy under the condition of 140 cm. It was observed that entrance surface dose decreased the most when was increased by 150 cm, 70 kV (C-spine lateral), 81 kV (L-spine lateral). It was also found out that as the between the focus-detector increased in the expansion of the video decreased but the difference was not significant when the distance was 180 cm or more. Skull AP showed the most reduction in the entrance surface dose when the tube voltage was changed by 80 kV, 0.1 mmCu, and 120 cm. Therefore, when using the automatic exposure control device, it is recommended to use the highest tube voltage if possible and to increase focus-detector distance at least by 150~200 cm in wall and 120~140 cm in table in consideration of the radiotechnologist's physical conditions, and to combine 0.1~0.3 mmCu and higher filters. It is thus expected to reduce patient dose by avoiding distortion of images and reducing the entrance surface dose.

Characterization of Deep Learning-Based and Hybrid Iterative Reconstruction for Image Quality Optimization at Computer Tomography Angiography (전산화단층촬영조영술에서 화질 최적화를 위한 딥러닝 기반 및 하이브리드 반복 재구성의 특성분석)

  • Pil-Hyun, Jeon;Chang-Lae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • For optimal image quality of computer tomography angiography (CTA), different iodine concentrations and scan parameters were applied to quantitatively evaluate the image quality characteristics of filtered back projection (FBP), hybrid-iterative reconstruction (hybrid-IR), and deep learning reconstruction (DLR). A 320-row-detector CT scanner scanned a phantom with various iodine concentrations (1.2, 2.9, 4.9, 6.9, 10.4, 14.3, 18.4, and 25.9 mg/mL) located at the edge of a cylindrical water phantom with a diameter of 19 cm. Data obtained using each reconstruction technique was analyzed through noise, coefficient of variation (COV), and root mean square error (RMSE). As the iodine concentration increased, the CT number value increased, but the noise change did not show any special characteristics. COV decreased with increasing iodine concentration for FBP, adaptive iterative dose reduction (AIDR) 3D, and advanced intelligent clear-IQ engine (AiCE) at various tube voltages and tube currents. In addition, when the iodine concentration was low, there was a slight difference in COV between the reconstitution techniques, but there was little difference as the iodine concentration increased. AiCE showed the characteristic that RMSE decreased as the iodine concentration increased but rather increased after a specific concentration (4.9 mg/mL). Therefore, the user will have to consider the characteristics of scan parameters such as tube current and tube voltage as well as iodine concentration according to the reconstruction technique for optimal CTA image acquisition.

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF

Generation of Building and Contour Layers for Digital Mapping Using LiDAR Data (LiDAR 데이터를 이용한 수치지도의 건물 및 등고선 레이어 생성)

  • Lee Dong-Cheon;Yom Jae-Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.3
    • /
    • pp.313-322
    • /
    • 2005
  • Rapid advances in technology and changes in human and cultural activities bring about changes to the earth surface in terms of spatial extension as well as time frame of the changes. Such advances introduce shorter updating frequency of maps and geospatial database. To satisfy these requirements, recent research efforts in the geoinformatics field have been focused on the automation and speeding up of the mapping processes which resulted in products such as the digital photogrammetric workstation, GPSIINS, applications of satellite imagery, automatic feature extraction and the LiDAR system. The possibility of automatically extracting buildings and generating contours from airborne LiDAR data has received much attention because LiDAR data produce promising results. However, compared with the manually derived building footprints using traditional photogrammetric process, more investigation and analysis need to be carried out in terms of accuracy and efficiency. On the other hand, generation of the contours with LiDAR data is more efficient and economical in terms of the quality and accuracy. In this study, the effects of various conditions of the pre-processing phase and the subsequent building extraction and contour generation phases for digital mapping have on the accuracy were investigated.

Improvement of Tourism Information Web Contents in Multicultural Society (다문화사회의 관광정보 웹 콘텐츠 개선 방안)

  • Lee, Yong-Jae;Kim, Hee-Young
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.413-422
    • /
    • 2010
  • With the beginning of foreign workers' immigration since 1990, Korea has faced multi-cultural society. At the same time, the number of female marriage immigrants have constantly increased. But the social services for immigrants are not yet prepared. According to the research on the actual condition of immigrants' culture enjoyment, which was done by Ministry of Culture, Sports and Tourism of Korea, the most preferable leisure activity of immigrants is 'sightseeing'. So this study focused on improvement of web contents of tourism information to satisfy the information needs of immigrants. Concretely, this study analysed the present condition of the existing tourism web contents, and analysed deeply the web site 'Tourism Busan' for special reference. Especially this study tried to analyse VOD images among web contents of 'Tourism Busan', and provided concrete improvement plan for that. And also this study processed interview with marriage immigrants to provide web site evaluation at the level of immigrants' eyes. As a result of evaluation, immigrants was the most dissatisfied with 'contents quality', and showed lower dissatisfaction at 'service quality', 'interface quality' factors.

The fabrication and analysis of IR flat-band pass filter using chalcogenide thin films (칼코게나이드 박막을 이용한 IR flat-band pass filter 제작 및 특성 평가)

  • Kim, Jin-Hee;Yeo, Jong-Bin;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.231-231
    • /
    • 2008
  • 최근 인터넷의 보급과 함께 고화질 및 양방향 TV, VOD 방송, 화상 전화 등의 멀티미디어 시대가 열리면서 초고속 통신 시스템에 대한 관심이 증가되고 있다. 특히 화상이나 동영상 같은 대량의 정보가 졸은 품질 및 빠른 속도로 전달될 수 있는 통신 시스템의 필요성이 대두됨에 따라 가장 효율적인 고속 전송 수단으로 광통신이 이용되고 있으며 그에 따른 광통신 능 수동 소자 개발에 관한 연구도 활발히 이루어지고 있다. 이러한 광통신 소자 중 원하는 빛을 선택적으로 투과하고 반사할 수 있는 flat-band pass(FP) filter의 역할이 중요한 부분을 차지하고 있다. 본 논문에서는 IR 영역에서 투과성이 우수한 칼코게나이드 물질을 이용해 l 차원 광자결정구조의 FP-filter를 설계, 제작하고 그에 대한 특성을 평가하였다. 시료는 5N의 순도를 갖는 As, Se, Te 물질을 준비하고 $As_xSe_yTe_z$를 조성비에 맞추어서 석영관에 진공 봉입한 후 용융 혼합하여 $As_{33}Se_{67}$$As_{40}Se_{25}Te_{35}$ 조성의 두 가지 비정질 벌크를 제작하였다. 제작된 시료의 굴절률은 ellipsometer을 사용하여 측정하였고, 본 연구진이 자체 개발한 계산툴에 따라 다중층막 구조를 설계하였다. 열 증착법을 이용하여 설계된 구조에 맞게 기판에 올리는 방법으로 1차원 광자결정 구조의 다중층막 샘플을 제작하였고 UV-Vis-IR Spectroscopy를 사용하여 반사도와 투과도를 측정하였다. 광통신용 L/C 밴드 주파수 범위에서 투과성이 우수한 칼코게나이드 박막의 1차원 광자결정 구조는 FP-filter등의 소자로써 유용하게 사용될 수 있다.

  • PDF

Intercomparison of Satellite-based Climate Hazards Group InfraRed Precipitation with Stations (CHIRPS) Gridded Dataset and Rain Gauge Data over Korea (Climate Hazards Group InfraRed Precipitation with Station (CHIRPS)와 한반도 지상관측 강수량 자료의 비교 평가)

  • Jeon, Min-Gi;Nam, Won-Ho;Mun, Young-Sik;Kim, Taegon;Hong, Eun-Mi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.197-201
    • /
    • 2018
  • 인공위성 기반의 원격탐사자료는 홍수, 가뭄 등 자연재해에 대한 모니터링 및 예측에 활용되어 왔으며, 특히 인공위성을 이용한 광역적 강수량 추정 자료는 지형적 제약을 받는 지상관측자료와 비교하여 시공간적으로 연속적이고 균질한 강수량 자료 취득이 가능하다는 장점이 있다. 우리나라의 경우 상대적으로 조밀한 지상관측망이 구축되어 있어 공간적으로 상세한 강수량 정보를 생산할 수 있는 여건을 갖추고 있지만, 북한 지역의 경우 기상, 수문, 통계자료에 관한 자료의 접근 및 품질의 제한성으로 인해 미계측 지역에 대한 강수량의 추정에 한계가 있다. CHIRPS (Climate Hazards Group InfraRed Precipitation with Stations) 데이터는 1999년부터 미국국제개발처 (U.S. Agency for International Development, USAID), 미국항공우주국 (National Aeronautics and Space Administration, NASA), 미국해양대기청 (National Oceanic and Atmospheric Administration, NOAA)의 지원으로 개발된 전지구 강우데이터 자료이다. CHIRPS는 1981년부터 현재까지 전지구 강우자료를 0.05도 격자 해상도로 제공하고 있으며, 강수량의 추세 분석 및 가뭄 모니터링을 위해 활용되고 있다. 본 연구에서는 CHG (Climate Hazards Group)에서 제공하고 있는 인공위성을 이용한 광역적 강수량 추정 자료인 CHIRPS와 남한 및 북한의 지상관측 강수량 자료와의 비교를 통해 위성으로부터 유도된 격자 강수량자료의 정확도 및 지역적인 강수추정의 불확실성을 평가하고, 수자원 및 재해 분야 이용 가능성을 검토하고자 한다.

  • PDF

Evaluation of 3DVH Software for the Patient Dose Analysis in TomoTherapy (토모테라피 환자 치료 선량 분석을 위한 3DVH 프로그램 평가)

  • Song, Ju-Young;Kim, Yong-Hyeob;Jeong, Jae-Uk;Yoon, Mee Sun;Ahn, Sung-Ja;Chung, Woong-Ki;Nam, Taek-Keun
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.201-207
    • /
    • 2015
  • The new function of 3DVH software for dose calculation inside the patient undergoing TomoTherapy treatment by applying the measured data obtained by ArcCHECK was recently released. In this study, the dosimetric accuracy of 3DVH for the TomoTherapy DQA process was evaluated by the comparison of measured dose distribution with the dose calculated using 3DVH. The 2D diode detector array MapCHECK phantom was used for the TomoTherapy planning of virtual patient and for the measurement of the compared dose. The average pass rate of gamma evaluation between the measured dose in the MapCHECK phantom and the recalculated dose in 3DVH was $92.6{\pm}3.5%$, and the error was greater than the average pass rate, $99.0{\pm}1.2%$, in the gamma evaluation results with the dose calculated in TomoTherapy planning system. The error was also greater than that in the gamma evaluation results in the RapidArc analysis, which showed the average pass rate of $99.3{\pm}0.9%$. The evaluated accuracy of 3DVH software for TomoTherapy DQA process in this study seemed to have some uncertainty for the clinical use. It is recommended to perform a proper analysis before using the 3DVH software for dose recalculation of the patient in the TomoTherapy DQA process considering the initial application stage in clinical use.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.