• Title/Summary/Keyword: 영상품질평가

Search Result 428, Processing Time 0.026 seconds

Evaluation of Comparison of Noise Power Spectrum according to the Time of Using Electronic Portal Imaging Device (EPID) for LINAC System (선형가속기의 시간에 따르는 전자조사문영상기구의 잡음전력스펙트럼 비교 평가)

  • Jung-Whan Min;Hoi-Woun Jeong
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.117-123
    • /
    • 2024
  • This study was to assessment of quality assurance (QA) and noise characteristics of Noise Power Spectrum (NPS) according to the time of by using electronic portal imaging device (EPID) for LINAC (Linear Accelerator). LINAC device was (Varian ClinacR iX LINAC, USA) used and the were 40 × 30 cm2 of detector size were 1024 × 768 photo-electric diode array size. Signal could be obtained the K-space image of white noise images for NPS and we used to Overlap, Non-Overlap, Out of Penumbra, Flatness, Symmetry, Symmetry Rt, Lt methods. The 2013s NPS image Out of Penumbra quantitatively value more than 2013s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. Thus, the 2022s NPS image Out of Penumbra quantitatively value more than 2022s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. The assessment of comparison of white noise for NPS image noise and intensity of this study were to that should be used efficiently of the LINAC EPID detector system for Overlap method for International Electro-technical Commission (IEC).

Implementation and Performance Evaluation of a Wireless VoIP System based on the Binary-CDMA Technology (Binary CDMA 기반의 무선 VoIP 시스템의 구현 및 성능평가)

  • Choi, Jae-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.12
    • /
    • pp.2555-2562
    • /
    • 2011
  • Binary CDMA is a new standard technology for wireless communication developed by our country that makes high speed communications and good quality of services. In this paper we researched the development methods and implementation of a wireless VoIP System based on the Binary-CDMA technology that makes it freely installed in any place without phone cables and laying works. We designed the structure of the Binary-CDMA Wireless VoIP System and defined messages and data structures for call control. And then we designed and implemented call control message flow between VoIP terminals for user's communication.

Internal Quality Evaluation and Age Identification of Fresh Korean Ginseng using Magnetic Resonance Imaging (자기공명영상을 이용한 수삼의 내부 품질평가 및 연근판정)

  • 임종국;김철수;이승조;김성민
    • Journal of Biosystems Engineering
    • /
    • v.28 no.2
    • /
    • pp.157-166
    • /
    • 2003
  • The purpose of this study is to characterize the internal physical properties of fresh Korean ginsengs (Panax ginseng C.A. Meyer) through a magnetic resonance imaging (MRI) technique. Current external visual inspection cannot determine internal quality of ginsengs successfully. Relaxation time constants, T$_1$ and T$_2$*, were obtained from a series of MR images. Calculated Ti values were varied with different physiological states of ginseng tissues. Internal imaging information was obtained nondestructively from fresh ginsengs. One- and two-dimensional image analyses were performed. One-dimensional image analysis showed a potential of age identification of ginsengs rapidly. Internal quality of normal and abnormal ginsengs was evaluated using two-dimensional MR images. Various types of internal defects such as internal cavity and rotten spot were visualized clearly. The MRI technique had a feasibility to detect internal defects of fresh ginsengs effectively.

A Method of Estimating Distortion in Pixel-Domain Wyner-Ziv Residual Video Coding (화면 간 차이신호의 화소영역 위너-지브 비디오 부호화 기법에서 왜곡 예측방법)

  • Kim, Jin-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.4
    • /
    • pp.891-898
    • /
    • 2014
  • The DVC (Distributed Video Coding) provides a theoretical basis for the implementation of light video encoder. Conventionally, lots of studies have been focused on the codec scheme of Stanford University that has a feedback channel to control the bit rate finely. However, the codec scheme can not evaluate the qualities of the frames reconstructed by the received parity bits at the decoder side. This paper presents an efficient method of estimating distortion by correcting the virtual channel noises in side information and then facilitating the measurements of the visual qualities. Through several simulations, it is shown that the proposed method is very efficient in estimating the visual qualities of the reconstructed WZ frames.

Visually Lossless Image Compression for Digital Cinema Distribution Based on DCI Specification (DCI 규격을 만족하는 디지털시네마 배급을 위한 시각적 무손실 압축 연구)

  • Kim, Chul-Hyun;Paik, Joon-Ki
    • Journal of Broadcast Engineering
    • /
    • v.13 no.1
    • /
    • pp.99-108
    • /
    • 2008
  • This raper analyzes the effect of visually lossless image compression for efficient distribution of digital cinema. Currently, distribution of digital cinema is carried out based on JPEG 2000 standard that has been selected by DCI. We first summarize characteristics of JPEG 2000, and then define the concept of visually lossless coding that plays an important role in digital cinema distribution. We provide a test for JPEG 2000 compression performance according to DCI specification for visually lossless. Based on the experiment, the result satisfies high quality for cinema distribution.

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.

Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator (다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Kim, Woo Chul;Ji, Young Hoon;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • For evaluating the treatment planning accurately, the quality assurance for treatment planning is recommended when patients were treated with IMRT which is complex and delicate. To realize this purpose, treatment plan quality assurance software can be used to verify the delivered dose accurately before and after of treatment. The purpose of this study is to evaluate the accuracy of treatment plan quality assurance software for each IMRT plan according to MLC DLG (dosimetric leaf gap). Novalis Tx with a built-in HD120 MLC was used in this study to acquire the MLC dynalog file be imported in MobiusFx. To establish IMRT plan, Eclipse RTP system was used and target and organ structures (multi-target, mock prostate, mock head/neck, C-shape case) were contoured in I'mRT phantom. To verify the difference of dose distribution according to DLG, MLC dynalog files were imported to MobiusFx software and changed the DLG (0.5, 0.7, 1.0, 1.3, 1.6 mm) values in MobiusFx. For evaluation dose, dose distribution was evaluated by using 3D gamma index for the gamma criteria 3% and distance to agreement 3 mm, and the point dose was acquired by using the CC13 ionization chamber in isocenter of I'mRT phantom. In the result for point dose, the mock head/neck and multi-target had difference about 4% and 3% in DLG 0.5 and 0.7 mm respectively, and the other DLGs had difference less than 3%. The gamma index passing-rate of mock head/neck were below 81% for PTV and cord, and multi-target were below 30% for center and superior target in DLGs 0.5, 0.7 mm, however, inferior target of multi-target case and parotid of mock head/neck case had 100.0% passing rate in all DLGs. The point dose of mock prostate showed difference below 3.0% in all DLGs, however, the passing rate of PTV were below 95% in 0.5, 0.7 mm DLGs, and the other DLGs were above 98%. The rectum and bladder had 100.0% passing rate in all DLGs. As the difference of point dose in C-shape were 3~9% except for 1.3 mm DLG, the passing rate of PTV in 1.0 1.3 mm were 96.7, 93.0% respectively. However, passing rate of the other DLGs were below 86% and core was 100.0% passing rate in all DLGs. In this study, we verified that the accuracy of treatment planning QA system can be affected by DLG values. For precise quality assurance for treatment technique using the MLC motion like IMRT and VMAT, we should use appropriate DLG value in linear accelerator and RTP system.

Quality Characteristics of White Pan Bread with Mesangi(Capsosiphon fulvecense) (매생이를 첨가한 식빵의 품질 특성)

  • An, Hye-Lyung;Lee, Kwang-Suck;Park, Sang-Jun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.18 no.4
    • /
    • pp.563-568
    • /
    • 2008
  • The principal objective of this study was to determine the optimal ratio of mesangi added to bread. In our experiments, the mesangi was added at levels of 0, 1, 2, 3, 4%. The properties of the prepared breads were analyzed in terms of volume of dough, specific volume, CrumbScan, color and sensory evaluation. The volume of the dough to which 1% mesangi has been added was the greatest and the specific volume of the bread to which 2% mesangi was added was also greater than that of the control bread. The bread to which 4% mesangi has been added evidenced the highest elongation at 1.39, the most profound thickness(0.05 cm) and the most prominent chromaticity of the skin. With regard to color values, as more mesangi was added the L value decreased. As the result of the sensory evaluation, the bread to which 1% mesangi was added was found to be the most preferable in terms of moistness, softness, taste and overall acceptability.

  • PDF

Simulation Analysis of GPS Reception Environment of Unified Control Points Using GIS (GIS를 이용한 통합기준점의 GPS 수신환경 모의 분석)

  • Kim, Tae Woo;Yun, Hong Sik;Kim, Kwang Bae;Jung, Woon Chul
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.6
    • /
    • pp.609-616
    • /
    • 2017
  • National Geographic Information Institute has established a plan that preoccupies UCPs (Unified Control Points) at 2~3km intervals in urban areas by considering the distance between existing UCPs by satellite images and aerial photographs in 2015. In this study, we discussed the method of selecting the locations of optimal UCPs by simulating GPS reception environment in candidate sites for UCPs using GIS. For this purpose, we selected new candidate sites for installing UCPs using satellite images and aerial photographs, and analyzed the GPS reception environment by calculating the visibility distance from buildings around UCPs using GIS skyline analysis. The number of and the arrangement of visible satellites that are capable of GPS satellite reception from the viewpoint of sky view were showed by GIS skyline analysis. Quality evaluation results of GPS observation data were compared with average PDOP calculated from hourly PDOP and TEQC in two points of Sungkyunkwan University during 8 hours. As a result of GPS reception environment using GIS, if the PDOP increases, the data acquisition rate is lowed, and the multipath error and the cycle slip are increased. Thus, this study verified that the quality of GPS observation data can be secured by constructing three-dimensional spatial information and simulating PDOP when preoccupying multiple UCPs using GIS.

An Efficient Data Processing Method to Improve the Geostationary Ocean Color Imager (GOCI) Data Service (천리안 해양관측위성의 배포서비스 향상을 위한 자료 처리 효율화 방안 연구)

  • Yang, Hyun;Oh, Eunsong;Han, Tai-Hyun;Han, Hee-Jeong;Choi, Jong-Kuk
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • We proposed and verified the methods to maintain data qualities as well as to reduce data volume for the Geostationary Ocean Color Imager (GOCI), the world's first ocean color sensor operated in geostationary orbit. For the GOCI level-2 data, 92.9% of data volume could be saved by only the data compression. For the GOCI level-1 data, however, just 20.7% of data volume could be saved by the data compression therefore another approach was required. First, we found the optimized number of bits per a pixel for the GOCI level-1 data from an idea that the quantization bit for the GOCI (i.e. 12 bit) was less than the number of bits per a pixel for the GOCI level-1 data (i.e. 32 bit). Experiments were conducted using the $R^2$ and the Modulation Transfer Function (MTF). It was quantitatively revealed that the data qualities were maintained although the number of bits per a pixel was reduced to 14. Also, we performed network simulations using the Network Simulator 2 (Ns2). The result showed that 57.7% of the end-toend delay for a GOCI level-1 data was saved when the number of bits per a pixel was reduced to 14 and 92.5% of the end-to-end delay for a GOCI level-2 data was saved when 92.9% of the data size was reduced due to the compression.